Ana Champi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ana Champi has a total of 169 co-authors. Here are the top co-authors by number of shared publications:
F.C. Marques
Univ Estadual Campinas, UNICAMP, Inst Fis Gleb Wataghin, BR-13083970 Campinas, SP, Brazil
9 shared publicationsMichel Mendoza
Center of Natural and Human Sciences, Federal University of ABC, Bangú 5001, 09210-580 Sao Paulo, Brazil
3 shared publications- Pablo Esquinazi
Division of Quantum Magnetism and Superconductivity, Felix-Bloch-Institute for Solid State Physics, University of Leipzig, 04103 Leipzig, Germany
3 shared publications - Andre Santarosa Ferlauto
Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC
2 shared publications F. C. Marques
Universidade Estadual de Campinas, Campinas, Brasil
2 shared publications- Fernando Alvarez
Instituto de Física ‘Gleb Wataghin’ (IFGW), Universidade Estadual de Campinas (UNICAMP)
2 shared publications
Latest Publications
- Open Access
- 17 August 2026
- Published by Editoriales Iberoamericanos in Revista DCS
- Vol. 23 (94) , e6812
Estudo dos óxidos de grafeno e suas potenciais aplicações em biossensores
Atualmente, o óxido de grafeno (GO, do termo em inglês Graphene Oxide) tem despertado grande interesse como material de funcionalização para o desenvolvimento de diferentes tipos de biossensores, devido à sua elevada dispersibilidade em meios aquosos, ampla área superficial e à presença de grupos funcionais oxigenados em sua estrutura. Nesse contexto, este trabalho reúne e discute as principais informações relacionadas ao óxido de grafeno, principais rotas de síntese, seus grupos funcionais, biocompatibilidade e potencial de aplicação como material de funcionalização em biossensores. Além disso, são abordadas algumas das principais limitações associadas as rotas de síntese do GO, destacando-se a necessidade de compreender e controlar parâmetros que possam influenciar suas características físico-químicas e sua biocompatibilidade. Dessa forma, busca-se evidenciar a importância da otimização dos processos de síntese para a obtenção de GO com propriedades adequadas para suas aplicações em biossensores.
- 17 August 2026
- Published by Editoriales Iberoamericanos in Revista DCS
- Vol. 23 (94) , e6812
Open AccessEstudo dos óxidos de grafeno e suas potenciais aplicações em biossensores
Atualmente, o óxido de grafeno (GO, do termo em inglês Graphene Oxide) tem despertado grande interesse como material de funcionalização para o desenvolvimento de diferentes tipos de biossensores, devido à sua elevada dispersibilidade em meios aquosos, ampla área superficial e à presença de grupos funcionais oxigenados em sua estrutura. Nesse contexto, este trabalho reúne e discute as principais informações relacionadas ao óxido de grafeno, principais rotas de síntese, seus grupos funcionais, biocompatibilidade e potencial de aplicação como material de funcionalização em biossensores. Além disso, são abordadas algumas das principais limitações associadas as rotas de síntese do GO, destacando-se a necessidade de compreender e controlar parâmetros que possam influenciar suas características físico-químicas e sua biocompatibilidade. Dessa forma, busca-se evidenciar a importância da otimização dos processos de síntese para a obtenção de GO com propriedades adequadas para suas aplicações em biossensores.
- Open Access
- 19 June 2026
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 56 (4)
Influence of the pH on the Synthesis of Carbon Quantum Dots and Graphene Quantum Dots
In this work, we confirmed the presence of Carbon Quantum Dots (CQDs) by optical techniques such as UV-visible and photoluminescence (PL), after filtering the result of carbonization and sulfonation of microcrystalline cellulose (MCC), which are synthesis processes for obtaining these nanomaterials. The high-resolution transmission electron microscopy (HR-TEM) confirmed, not only the size of the particles, but the crystalline pattern of the carbon-based nanoparticles. The HR-TEM also indicates the presence of Graphene Quantum Dots (GQDs), as anisotropic-shaped particles were observed. Fluorescence and absorbance indicate the pH dependence on optical and structural properties, as well as on the production of CQDs and GQDs. The pH may influence the syntheses of CQDs and GQDs and the origin of their fluorescence, due to presence of functional groups such as hydroxyl, carboxyl, carbonyl, epoxy, and sulfoxide at low pH, and in the edge regions of these particles, with sp² hybridization. The Fourier Transform Infrared (FTIR) spectra was also measured, allowing to understand the functional groups present in the samples, and so, understand the groups responsible for the fluorescence.
- 19 June 2026
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 56 (4)
Open AccessInfluence of the pH on the Synthesis of Carbon Quantum Dots and Graphene Quantum Dots
In this work, we confirmed the presence of Carbon Quantum Dots (CQDs) by optical techniques such as UV-visible and photoluminescence (PL), after filtering the result of carbonization and sulfonation of microcrystalline cellulose (MCC), which are synthesis processes for obtaining these nanomaterials. The high-resolution transmission electron microscopy (HR-TEM) confirmed, not only the size of the particles, but the crystalline pattern of the carbon-based nanoparticles. The HR-TEM also indicates the presence of Graphene Quantum Dots (GQDs), as anisotropic-shaped particles were observed. Fluorescence and absorbance indicate the pH dependence on optical and structural properties, as well as on the production of CQDs and GQDs. The pH may influence the syntheses of CQDs and GQDs and the origin of their fluorescence, due to presence of functional groups such as hydroxyl, carboxyl, carbonyl, epoxy, and sulfoxide at low pH, and in the edge regions of these particles, with sp² hybridization. The Fourier Transform Infrared (FTIR) spectra was also measured, allowing to understand the functional groups present in the samples, and so, understand the groups responsible for the fluorescence.
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3260 (1)
Electrochemical characterization of a carbon sensor for ascorbic acid detection
A commercial screen-printed carbon electrode was employed as a low-cost platform for the detection of ascorbic acid (AA). The surface of the working electrode and solutions of AA were characterized by Raman and UV–Vis analysis. The surface of the working and counter electrodes is composed of carbon, while the surface of the reference electrode is made of polyester. The surface of the electrode became covered with material when in contact with AA, and EDS showed a decrease in the content of carbon in the electrode area and an increase in the content of oxygen and of elements that are a part of the PBS buffer solution. The UV–Vis spectra of AA showed an absorption band at wavelengths of 265–270 nm, which increased in intensity with increase in concentration. The electrochemical behavior of AA was found to involve an irreversible oxidation and a broad anodic peak with no cathodic peak. The current of the anodic peak varied linearly with the square root of the scan rate, indicating that the mass transport process is controlled by a diffusion mechanism. Chronoamperometry provided stepwise current responses that varied linearly with the concentration of AA. A calibration plot was obtained with R 2 = 0.997 for the concentration range of 10–100 µM. Chronoamperometry was found to be the most convenient method for the detection of AA using the commercial screen-printed carbon electrode.
- 1 June 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3260 (1)
Open AccessElectrochemical characterization of a carbon sensor for ascorbic acid detection
A commercial screen-printed carbon electrode was employed as a low-cost platform for the detection of ascorbic acid (AA). The surface of the working electrode and solutions of AA were characterized by Raman and UV–Vis analysis. The surface of the working and counter electrodes is composed of carbon, while the surface of the reference electrode is made of polyester. The surface of the electrode became covered with material when in contact with AA, and EDS showed a decrease in the content of carbon in the electrode area and an increase in the content of oxygen and of elements that are a part of the PBS buffer solution. The UV–Vis spectra of AA showed an absorption band at wavelengths of 265–270 nm, which increased in intensity with increase in concentration. The electrochemical behavior of AA was found to involve an irreversible oxidation and a broad anodic peak with no cathodic peak. The current of the anodic peak varied linearly with the square root of the scan rate, indicating that the mass transport process is controlled by a diffusion mechanism. Chronoamperometry provided stepwise current responses that varied linearly with the concentration of AA. A calibration plot was obtained with R 2 = 0.997 for the concentration range of 10–100 µM. Chronoamperometry was found to be the most convenient method for the detection of AA using the commercial screen-printed carbon electrode.
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3260 (1)
Study of induced defects of Ascorbic Acid incorporated in Graphene Oxide
This work reports a study on the structural defect due to the interaction between graphene oxide, synthesized via the modified Hummers method, and L-ascorbic acid (AA). The functionalization was carried out at 65 °C, and the evolution of the material’s properties was investigated as a function of time (15, 30, 45, 60, and 120 min). The resulting GO-AA samples were characterized by Fourier Transform Infrared (FTIR) spectroscopy, Raman spectroscopy, and Scanning Electron Microscopy (SEM). The analysis demonstrate that L-ascorbic acid was functionalized with GO, as evidenced by FTIR, which showed a change in the intensity of characteristic oxygenated bands, while Raman spectroscopy shows a variation in the intensity ratio between the D and G bands (I D /I G ), and an increase in defect density with interaction time. SEM images reveal morphological changes from smooth GO sheets to a more compact and crumpled GO-AA structure with increasing interaction time. Overall, the results demonstrate that interaction with L-ascorbic acid induces structural defects in graphene oxide.
- 1 June 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3260 (1)
Open AccessStudy of induced defects of Ascorbic Acid incorporated in Graphene Oxide
This work reports a study on the structural defect due to the interaction between graphene oxide, synthesized via the modified Hummers method, and L-ascorbic acid (AA). The functionalization was carried out at 65 °C, and the evolution of the material’s properties was investigated as a function of time (15, 30, 45, 60, and 120 min). The resulting GO-AA samples were characterized by Fourier Transform Infrared (FTIR) spectroscopy, Raman spectroscopy, and Scanning Electron Microscopy (SEM). The analysis demonstrate that L-ascorbic acid was functionalized with GO, as evidenced by FTIR, which showed a change in the intensity of characteristic oxygenated bands, while Raman spectroscopy shows a variation in the intensity ratio between the D and G bands (I D /I G ), and an increase in defect density with interaction time. SEM images reveal morphological changes from smooth GO sheets to a more compact and crumpled GO-AA structure with increasing interaction time. Overall, the results demonstrate that interaction with L-ascorbic acid induces structural defects in graphene oxide.
- 7 May 2026
- Published by Wiley in Polymer International
Influence of graphene oxide and glycerol in the production of alginate textile fibers for potential application in wound dressings
This study aimed to develop and characterize alginate‐based fibers incorporating glycerol and graphene oxide (GO) for potential application in wound dressings. Fibers were prepared using 10% (w/v) sodium alginate in 100 mL of 0.1 mol L −1 NaOH, with and without the addition of 2.5% (w/w) glycerol, and varying GO concentrations (0.01%, 0.1%, 0.5%, and 1% w/w), followed by wet‐spinning into a 2% (w/v) CaCl 2 coagulation bath. Microscopy analysis confirmed the homogeneous dispersion of GO in the fiber structure. The incorporation of 0.5% (w/w) GO increased fiber tenacity by 20.95%, while glycerol addition enhanced elongation by 21.68% compared to neat alginate fibers. The combination of glycerol and 0.5% (w/w) GO improved water absorption capacity, reaching 104% water absorption. Thermal analysis (DSC and TGA) indicated that the presence of GO and glycerol contributed to enhanced thermal stability. Moreover, fibers containing 0.1% (w/w) GO inhibited E. coli bacteria by 37.21%, compared to 10.70% inhibition by pure alginate fibers. These findings demonstrate that the incorporation of GO and glycerol into alginate fibers offers a promising approach for the development of advanced wound dressings. © 2026 Society of Chemical Industry.
- 7 May 2026
- Published by Wiley in Polymer International
Influence of graphene oxide and glycerol in the production of alginate textile fibers for potential application in wound dressings
This study aimed to develop and characterize alginate‐based fibers incorporating glycerol and graphene oxide (GO) for potential application in wound dressings. Fibers were prepared using 10% (w/v) sodium alginate in 100 mL of 0.1 mol L −1 NaOH, with and without the addition of 2.5% (w/w) glycerol, and varying GO concentrations (0.01%, 0.1%, 0.5%, and 1% w/w), followed by wet‐spinning into a 2% (w/v) CaCl 2 coagulation bath. Microscopy analysis confirmed the homogeneous dispersion of GO in the fiber structure. The incorporation of 0.5% (w/w) GO increased fiber tenacity by 20.95%, while glycerol addition enhanced elongation by 21.68% compared to neat alginate fibers. The combination of glycerol and 0.5% (w/w) GO improved water absorption capacity, reaching 104% water absorption. Thermal analysis (DSC and TGA) indicated that the presence of GO and glycerol contributed to enhanced thermal stability. Moreover, fibers containing 0.1% (w/w) GO inhibited E. coli bacteria by 37.21%, compared to 10.70% inhibition by pure alginate fibers. These findings demonstrate that the incorporation of GO and glycerol into alginate fibers offers a promising approach for the development of advanced wound dressings. © 2026 Society of Chemical Industry.
- Open Access
- 26 April 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (18) , 26797-26810
Role of Conductivity in the Ecotoxicological Effects of Lyophilized Graphene Oxides on Lactuca sativa and Allium cepa
The ecotoxicity of graphene oxide (GO) remains insufficiently characterized, particularly regarding how synthesis parameters influence its environmental behavior. In this study, we investigated the physicochemical properties and biological effects of GO synthesized by a modified Hummer’s method and exposed to two oxidative interaction times with hydrogen peroxide (H2O2) for 1 h (1h-LSGO) and 5 h (5h-LSGO) under identical sonication conditions. GO was characterized by UV–vis spectroscopy, FTIR-ATR, zeta potential, electrical conductivity, and atomic force microscopy (AFM). Ecotoxicological responses of 1h-LSGO and 5h-LSGO were evaluated in Lactuca sativa and Allium cepa, focusing on germination, root elongation, antioxidant activity, chromosomal aberrations, and mitotic index, mainly due to the effects of GO conductivity. Treatment with a shorter oxidative interaction (1h-LSGO) produced GO with higher oxygen content (21.2%), partial restoration of sp2 domains (7.6%), conductivity (0.0249 mS·cm–1), and a more negative zeta potential (−40.1 mV). Meanwhile, the longest interaction (5h-LSGO) favored partial restoration of sp2 domains (48.1%), showing ∼20-fold higher conductivity (0.485 mS·cm–1) and zeta potential (−32.2 mV). Both materials caused only slight effects on seed germination, but their sublethal responses differed between species: 1h-LSGO significantly inhibited L. sativa root elongation (30%) and modulated antioxidant activity, while 5h-LSGO reduced A. cepa root growth (60%), decreased the mitotic index, and increased chromosomal aberrations at 100 mg L–1 (p < 0.05). In summary, the oxidative interaction time of H2O2 was revealed as a critical parameter that controls the surface chemistry of GO, its electronic structure, its conductivity, and its ecotoxic potential, with higher conductivity in 5h-LSGO correlating with stronger genotoxicity in A. cepa (e.g., reduced mitotic index and increased chromosomal aberrations at 100 mg L–1, p < 0.05).
- 26 April 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (18) , 26797-26810
Open AccessRole of Conductivity in the Ecotoxicological Effects of Lyophilized Graphene Oxides on Lactuca sativa and Allium cepa
The ecotoxicity of graphene oxide (GO) remains insufficiently characterized, particularly regarding how synthesis parameters influence its environmental behavior. In this study, we investigated the physicochemical properties and biological effects of GO synthesized by a modified Hummer’s method and exposed to two oxidative interaction times with hydrogen peroxide (H2O2) for 1 h (1h-LSGO) and 5 h (5h-LSGO) under identical sonication conditions. GO was characterized by UV–vis spectroscopy, FTIR-ATR, zeta potential, electrical conductivity, and atomic force microscopy (AFM). Ecotoxicological responses of 1h-LSGO and 5h-LSGO were evaluated in Lactuca sativa and Allium cepa, focusing on germination, root elongation, antioxidant activity, chromosomal aberrations, and mitotic index, mainly due to the effects of GO conductivity. Treatment with a shorter oxidative interaction (1h-LSGO) produced GO with higher oxygen content (21.2%), partial restoration of sp2 domains (7.6%), conductivity (0.0249 mS·cm–1), and a more negative zeta potential (−40.1 mV). Meanwhile, the longest interaction (5h-LSGO) favored partial restoration of sp2 domains (48.1%), showing ∼20-fold higher conductivity (0.485 mS·cm–1) and zeta potential (−32.2 mV). Both materials caused only slight effects on seed germination, but their sublethal responses differed between species: 1h-LSGO significantly inhibited L. sativa root elongation (30%) and modulated antioxidant activity, while 5h-LSGO reduced A. cepa root growth (60%), decreased the mitotic index, and increased chromosomal aberrations at 100 mg L–1 (p < 0.05). In summary, the oxidative interaction time of H2O2 was revealed as a critical parameter that controls the surface chemistry of GO, its electronic structure, its conductivity, and its ecotoxic potential, with higher conductivity in 5h-LSGO correlating with stronger genotoxicity in A. cepa (e.g., reduced mitotic index and increased chromosomal aberrations at 100 mg L–1, p < 0.05).
- Open Access
- 2 January 2026
- Published by Editoriales Iberoamericanos in Revista DCS
- Vol. 23 (86) , e4310
COMPÓSITOS À BASE DE ALGINATO E ÓXIDO DE GRAFENO EM TÊXTEIS MÉDICOS: APLICAÇÕES, DESAFIOS E PERSPECTIVAS FUTURAS
Têxteis médicos são materiais projetados para uso em aplicações na área da saúde, podendo ser fabricados a partir de diversas matérias-primas. O alginato é um biopolímero bastante estudado e utilizado na produção de fibras, filmes, hidrogéis, scaffolds e curativos para o desenvolvimento de têxteis médicos. Materiais derivados de biopolímeros podem apresentar baixa resistência à tração e à compressão, mas a adição de outros materiais, como o óxido de grafeno, pode melhorar essas propriedades, bem como conferir atributos adicionais. O óxido de grafeno vem sendo estudado para aplicações em têxteis médicos devido às suas múltiplas propriedades, como alta resistência mecânica, boa biocompatibilidade e propriedades antimicrobianas, podendo ser ainda associado a outros materiais com o objetivo de funcionalizá-los. Este trabalho teve como objetivo reunir as principais informações sobre as aplicações atuais, os desafios e as perspectivas futuras do uso de alginato e óxido de grafeno na produção de compósitos para têxteis médicos.
- 2 January 2026
- Published by Editoriales Iberoamericanos in Revista DCS
- Vol. 23 (86) , e4310
Open AccessCOMPÓSITOS À BASE DE ALGINATO E ÓXIDO DE GRAFENO EM TÊXTEIS MÉDICOS: APLICAÇÕES, DESAFIOS E PERSPECTIVAS FUTURAS
Têxteis médicos são materiais projetados para uso em aplicações na área da saúde, podendo ser fabricados a partir de diversas matérias-primas. O alginato é um biopolímero bastante estudado e utilizado na produção de fibras, filmes, hidrogéis, scaffolds e curativos para o desenvolvimento de têxteis médicos. Materiais derivados de biopolímeros podem apresentar baixa resistência à tração e à compressão, mas a adição de outros materiais, como o óxido de grafeno, pode melhorar essas propriedades, bem como conferir atributos adicionais. O óxido de grafeno vem sendo estudado para aplicações em têxteis médicos devido às suas múltiplas propriedades, como alta resistência mecânica, boa biocompatibilidade e propriedades antimicrobianas, podendo ser ainda associado a outros materiais com o objetivo de funcionalizá-los. Este trabalho teve como objetivo reunir as principais informações sobre as aplicações atuais, os desafios e as perspectivas futuras do uso de alginato e óxido de grafeno na produção de compósitos para têxteis médicos.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Ensino de Física
- Vol. 48
DFT+U: a Hubbard Hamiltonian-based correction for modeling localized electronic states
Density Functional Theory (DFT) is a widely used method to calculate the electronic structure of materials. One of the pivotal ingredients in the traditional DFT modeling strategy is the Exchange and Correlation Functional ( E X C). An inappropriate choice of the E X C can lead to substantially erroneous predictions. For example, the Generalized Gradient Approximation (GGA) dramatically fails to predict the band gap of strongly correlated systems. DFT + U, a corrective methodology based on the Hubbard model, offers a cost-effective approach to address this problem. This work provides an introductory overview of the DFT + U method. First, we discuss the importance of the E X C functional in DFT, and then we introduce the DFT+U approach. Subsequently, we illustrate the method’s applicability by calculating the electronic, magnetic, and structural properties of FeO using PBE and PBE+U functionals. We show that GGA fails to describe the electronic character and magnetic ordering of FeO, while DFT + U provides an accurate description of the FeO properties.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Ensino de Física
- Vol. 48
Open AccessDFT+U: a Hubbard Hamiltonian-based correction for modeling localized electronic states
Density Functional Theory (DFT) is a widely used method to calculate the electronic structure of materials. One of the pivotal ingredients in the traditional DFT modeling strategy is the Exchange and Correlation Functional ( E X C). An inappropriate choice of the E X C can lead to substantially erroneous predictions. For example, the Generalized Gradient Approximation (GGA) dramatically fails to predict the band gap of strongly correlated systems. DFT + U, a corrective methodology based on the Hubbard model, offers a cost-effective approach to address this problem. This work provides an introductory overview of the DFT + U method. First, we discuss the importance of the E X C functional in DFT, and then we introduce the DFT+U approach. Subsequently, we illustrate the method’s applicability by calculating the electronic, magnetic, and structural properties of FeO using PBE and PBE+U functionals. We show that GGA fails to describe the electronic character and magnetic ordering of FeO, while DFT + U provides an accurate description of the FeO properties.
- 30 April 2025
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 55 (4) , 1-11
Influence of the Reduction Temperature of TiO2/rGO Nanotubes on the Structural Defects Studied by Raman Spectroscopy
- 30 April 2025
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 55 (4) , 1-11
Influence of the Reduction Temperature of TiO2/rGO Nanotubes on the Structural Defects Studied by Raman Spectroscopy