Michael Kolbe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael Kolbe has a total of 255 co-authors. Here are the top co-authors by number of shared publications:
Burkhard Beckhoff
Physikalisch-Technische Bundesanstalt (PTB)
21 shared publications- Matthias Müller
Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587 Berlin, Germany
10 shared publications Gerhard Ulm
Physikalisch-Technische Bundesanstalt (PTB)
9 shared publicationsB. Beckhoff
8 shared publications- Alexander Gottwald
Physikalisch-Technische Bundesanstalt (PTB)
5 shared publications Jan Weser
Physikalisch-Technische Bundesanstalt
5 shared publications
Latest Publications
- Open Access
- 16 October 2026
- Published by Springer Nature in Research Square
Enhanced resonant elastic x-ray scattering in XFEL-generated warm dense matter
Irradiation of solids with focused femtosecond XFEL pulses can drive them into warm dense matter (WDM) and populate excited electronic configurations that enable otherwise Pauli-blocked bound-bound transitions. These transient resonances substantially increase x-ray opacity and the elastic scattering factor. Here, we observe a transient enhancement of Cu elastic scattering near the L3 edge via Lα (2p–3d) transitions at 929.7 eV. The excitation sequence starts with photoionization, followed by Auger decay that produces high-energy electrons. These then trigger electron-impact ionization, creating a non-local thermodynamic (non-LTE) state. On a fs timescale, Cu ions remain at their cold-solid equilibrium positions while occupying excited electronic configurations with multiple 3d holes. Using XFEL pulses elastically scattered from a Cu-containing [SiC/Cu/B4C] multilayer, we spectrally resolve a multilayer-superlattice Bragg peak around the Lα resonance. Its amplitude and spectral width increase nonlinearly with excitation intensity. A self-consistent theory describing the formation of the non-LTE state and its x-ray optical properties links transient electronic configurations to the measured scattering response and reproduces the data. An effective two-level model quantifies a twelvefold enhancement of the imaginary scattering factor relative to cold Cu, demonstrating the role of transient resonances and enabling ionization- and state-selective contrast for ultrafast x-ray imaging.
- 16 October 2026
- Published by Springer Nature in Research Square
Open AccessEnhanced resonant elastic x-ray scattering in XFEL-generated warm dense matter
Irradiation of solids with focused femtosecond XFEL pulses can drive them into warm dense matter (WDM) and populate excited electronic configurations that enable otherwise Pauli-blocked bound-bound transitions. These transient resonances substantially increase x-ray opacity and the elastic scattering factor. Here, we observe a transient enhancement of Cu elastic scattering near the L3 edge via Lα (2p–3d) transitions at 929.7 eV. The excitation sequence starts with photoionization, followed by Auger decay that produces high-energy electrons. These then trigger electron-impact ionization, creating a non-local thermodynamic (non-LTE) state. On a fs timescale, Cu ions remain at their cold-solid equilibrium positions while occupying excited electronic configurations with multiple 3d holes. Using XFEL pulses elastically scattered from a Cu-containing [SiC/Cu/B4C] multilayer, we spectrally resolve a multilayer-superlattice Bragg peak around the Lα resonance. Its amplitude and spectral width increase nonlinearly with excitation intensity. A self-consistent theory describing the formation of the non-LTE state and its x-ray optical properties links transient electronic configurations to the measured scattering response and reproduces the data. An effective two-level model quantifies a twelvefold enhancement of the imaginary scattering factor relative to cold Cu, demonstrating the role of transient resonances and enabling ionization- and state-selective contrast for ultrafast x-ray imaging.
- 20 May 2023
- Published by Wiley in X-Ray Spectrometry
- Vol. 52 (5) , 204
In memoriam Jean‐Claude Dousse
- 9 May 2023
- Published by Wiley in X-Ray Spectrometry
- Vol. 52 (4) , 158-159
# EXSA2021 , EXSA first virtual conference in X‐ray Spectrometry
- 9 May 2023
- Published by Wiley in X-Ray Spectrometry
- Vol. 52 (4) , 158-159
# EXSA2021 , EXSA first virtual conference in X‐ray Spectrometry
- 9 September 2021
- Published by Wiley in X-Ray Spectrometry
- Vol. 51 (2) , 122-128
Quantification via X‐ray fluorescence analysis of oxygen in the surface layer of a Si‐sphere used as a new mass standard
The distribution of oxygen present in the surface layer of the Si‐sphere used as new mass standard is measured and quantified using the combined X‐ray fluorescence (XRF)/X‐ray photoelectron spectroscopy (XPS) surface analysis system in the Center for Measurement Standards, Industrial Technology Research Institute (CMS/ITRI). A radiometric calibration of the X‐ray source is not possible because the spectral distribution of the X‐ray tube used is complex and not stable over the long term. Hence, the quantification of oxygen on the Si‐sphere is based on a calibration curve that establishes a correlation between the mass deposition of oxygen from the calibration samples qualified by PTB and the ratio of the oxygen fluorescence to silicon RRS (resonant Raman scattering) intensities in the in‐house system. This paper presents the methodology for and the results of an oxygen quantification performed using the combined XRF/XPS surface analysis system. With a relative uncertainty of less than 10%, the average mass deposition of oxygen on the Si‐sphere was 133 ± 12 ng/cm 2 . The oxygen quantified via XRF is treated as a reference for the quantification of other elements on the surface layer. The quantification of carbon mass deposition in the surface layer in relation to the oxygen mass deposition is also described in this paper. The surface analysis system is part of our contribution to the realization and dissemination of the unit of the kilogram (based on its new definition) via the XRCD method.
- 9 September 2021
- Published by Wiley in X-Ray Spectrometry
- Vol. 51 (2) , 122-128
Quantification via X‐ray fluorescence analysis of oxygen in the surface layer of a Si‐sphere used as a new mass standard
The distribution of oxygen present in the surface layer of the Si‐sphere used as new mass standard is measured and quantified using the combined X‐ray fluorescence (XRF)/X‐ray photoelectron spectroscopy (XPS) surface analysis system in the Center for Measurement Standards, Industrial Technology Research Institute (CMS/ITRI). A radiometric calibration of the X‐ray source is not possible because the spectral distribution of the X‐ray tube used is complex and not stable over the long term. Hence, the quantification of oxygen on the Si‐sphere is based on a calibration curve that establishes a correlation between the mass deposition of oxygen from the calibration samples qualified by PTB and the ratio of the oxygen fluorescence to silicon RRS (resonant Raman scattering) intensities in the in‐house system. This paper presents the methodology for and the results of an oxygen quantification performed using the combined XRF/XPS surface analysis system. With a relative uncertainty of less than 10%, the average mass deposition of oxygen on the Si‐sphere was 133 ± 12 ng/cm 2 . The oxygen quantified via XRF is treated as a reference for the quantification of other elements on the surface layer. The quantification of carbon mass deposition in the surface layer in relation to the oxygen mass deposition is also described in this paper. The surface analysis system is part of our contribution to the realization and dissemination of the unit of the kilogram (based on its new definition) via the XRCD method.
- Open Access
- 11 December 2020
- Published by EDP Sciences in International Journal of Metrology and Quality Engineering
- Vol. 11, 18
Investigation of a cleaning procedure for silicon spheres used in the realization and dissemination of the redefined kilogram via combined spectroscopic and gravimetric measurements
The new definition of the SI kilogram requires new methods of realizing this unit. The X-ray crystal density method is a primary realization method and uses silicon spheres. The spheres get cleaned before each measurement, in order to remove surface contaminations and thus reduce their uncertainty contribution to the realization. Therefore, cleaning is an inherent part of the realization and dissemination of the kilogram. A cleaning method for silicon spheres is investigated, concerning its suitability as a part of the realization of the redefined kilogram. Six silicon spheres were used to determine the repeatability of the established cleaning method. Measurements of the spheres' mass and the quantification of their surface layer mass after cleaning were carried out in several cycles resulting in 29 mass and surface measurements. The repeatability of the cleaning method applied shows a standard deviation in the order of two micrograms for both the mass and the surface layer. The cleaning method therefore sufficiently fulfils these requirements.
- 11 December 2020
- Published by EDP Sciences in International Journal of Metrology and Quality Engineering
- Vol. 11, 18
Open AccessInvestigation of a cleaning procedure for silicon spheres used in the realization and dissemination of the redefined kilogram via combined spectroscopic and gravimetric measurements
The new definition of the SI kilogram requires new methods of realizing this unit. The X-ray crystal density method is a primary realization method and uses silicon spheres. The spheres get cleaned before each measurement, in order to remove surface contaminations and thus reduce their uncertainty contribution to the realization. Therefore, cleaning is an inherent part of the realization and dissemination of the kilogram. A cleaning method for silicon spheres is investigated, concerning its suitability as a part of the realization of the redefined kilogram. Six silicon spheres were used to determine the repeatability of the established cleaning method. Measurements of the spheres' mass and the quantification of their surface layer mass after cleaning were carried out in several cycles resulting in 29 mass and surface measurements. The repeatability of the cleaning method applied shows a standard deviation in the order of two micrograms for both the mass and the surface layer. The cleaning method therefore sufficiently fulfils these requirements.
- Open Access
- 24 November 2020
- Published by Wiley in X-Ray Spectrometry
- Vol. 50 (2) , 145-146
In memoriam Jean‐Claude Dousse
- 24 November 2020
- Published by Wiley in X-Ray Spectrometry
- Vol. 50 (2) , 145-146
Open AccessIn memoriam Jean‐Claude Dousse
- Open Access
- 23 August 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanolithography, MEMS, and MOEMS
- Vol. 18 (03) , 033501-6
Extreme UV secondary electron yield measurements of Ru, Sn, and Hf oxide thin films
Background: The secondary electron yield (SEY) of materials is important for topics as nanoparticle photoresists and extreme ultraviolet (EUV) optics contamination. Aim: Experimentally measure SEY and secondary electron energy distributions for Ru, Sn, and Hf oxide. Approach: The SEY and energy distribution resulting from 65 to 112 eV EUV radiation are measured for thin-film oxides or films with native oxide. Results: The total SEY can be explained by EUV absorption in the topmost nanometer of (native) oxide of the investigated materials. Conclusions: Although the relative SEY of Ru and Sn is well-explained by the difference in EUV absorption properties, the SEY of HfO2 is almost a factor 2 higher than expected. Based on the energy distribution of secondary electrons, this may be related to a lower barrier for secondary electron emission.
- 23 August 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanolithography, MEMS, and MOEMS
- Vol. 18 (03) , 033501-6
Open AccessExtreme UV secondary electron yield measurements of Ru, Sn, and Hf oxide thin films
Background: The secondary electron yield (SEY) of materials is important for topics as nanoparticle photoresists and extreme ultraviolet (EUV) optics contamination. Aim: Experimentally measure SEY and secondary electron energy distributions for Ru, Sn, and Hf oxide. Approach: The SEY and energy distribution resulting from 65 to 112 eV EUV radiation are measured for thin-film oxides or films with native oxide. Results: The total SEY can be explained by EUV absorption in the topmost nanometer of (native) oxide of the investigated materials. Conclusions: Although the relative SEY of Ru and Sn is well-explained by the difference in EUV absorption properties, the SEY of HfO2 is almost a factor 2 higher than expected. Based on the energy distribution of secondary electrons, this may be related to a lower barrier for secondary electron emission.
- 6 February 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (2) , 535-542
The U125 insertion device beamline at the Metrology Light Source
At the Metrology Light Source, an electron storage ring dedicated to metrological applications, the U125 insertion device beamline utilizes undulator radiation for various applications over a broad spectral range. Using a hybrid normal-incidence and grazing-incidence in-vacuum switchable plane-grating monochromator, a spectral region ranging from the near-infrared to soft X-ray is covered. The beamline is dedicated to surface-analytical methods, e.g. ellipsometry, photoelectron spectroscopy or photoemission tomography. The traceability of radiometric quantities, i.e. quantitative determination of the available radiant power (or photon flux), is required for some of these applications to support the metrological aspect of the measurements. In particular, attention is paid to the suppression of unwanted spectral contributions from higher diffraction orders, and to the monitoring of the radiation intensity during the measurements. With the results from the beamline commissioning, an uncertainty budget for all relevant radiometric quantities was established.
- 6 February 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (2) , 535-542
The U125 insertion device beamline at the Metrology Light Source
At the Metrology Light Source, an electron storage ring dedicated to metrological applications, the U125 insertion device beamline utilizes undulator radiation for various applications over a broad spectral range. Using a hybrid normal-incidence and grazing-incidence in-vacuum switchable plane-grating monochromator, a spectral region ranging from the near-infrared to soft X-ray is covered. The beamline is dedicated to surface-analytical methods, e.g. ellipsometry, photoelectron spectroscopy or photoemission tomography. The traceability of radiometric quantities, i.e. quantitative determination of the available radiant power (or photon flux), is required for some of these applications to support the metrological aspect of the measurements. In particular, attention is paid to the suppression of unwanted spectral contributions from higher diffraction orders, and to the monitoring of the radiation intensity during the measurements. With the results from the beamline commissioning, an uncertainty budget for all relevant radiometric quantities was established.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 103114
Transverse resonance island buckets for synchrotron-radiation based electron time-of-flight spectroscopy
At the Metrology Light Source (MLS), the compact electron storage ring of the Physikalisch-Technische Bundesanstalt (PTB) with a circumference of 48 m, a specific operation mode with two stable closed orbits for stored electrons was realized by transverse resonance island buckets. One of these orbits is closing only after three turns. In combination with single-bunch operation, the new mode was applied for electron time-of-flight spectroscopy with an interval of the synchrotron radiation pulses which is three times the revolution period at the MLS of 160 ns. The achievement is of significant importance for PTB’s future programs of angular-resolved electron spectroscopy with synchrotron radiation and similar projects at other compact electron storage rings. The scheme applied here for selecting the photons originating from a particular orbit by optical imaging has been used before in fs slicing applications and may be relevant for the BESSY VSR project of the Helmholtz-Zentrum Berlin.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 103114
Transverse resonance island buckets for synchrotron-radiation based electron time-of-flight spectroscopy
At the Metrology Light Source (MLS), the compact electron storage ring of the Physikalisch-Technische Bundesanstalt (PTB) with a circumference of 48 m, a specific operation mode with two stable closed orbits for stored electrons was realized by transverse resonance island buckets. One of these orbits is closing only after three turns. In combination with single-bunch operation, the new mode was applied for electron time-of-flight spectroscopy with an interval of the synchrotron radiation pulses which is three times the revolution period at the MLS of 160 ns. The achievement is of significant importance for PTB’s future programs of angular-resolved electron spectroscopy with synchrotron radiation and similar projects at other compact electron storage rings. The scheme applied here for selecting the photons originating from a particular orbit by optical imaging has been used before in fs slicing applications and may be relevant for the BESSY VSR project of the Helmholtz-Zentrum Berlin.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Quantitative Surface Characterization of Silicon Spheres by Combined X-Ray Fluorescence Analysis and X-Ray Photoelectron Spectroscopy Measurements
The future realization of the kilogram as the SI base unit of mass, by monocrystalline enriched 28 Si-spheres requires a reliable surface analysis of silicon spheres. An analytical instrument with complementary spectroscopic techniques is used for a quantitative surface characterization of such spheres. In particular, the mass deposition and the composition of the surface layer are measured. The presented principles of the quantification combine X-ray fluorescence spectroscopy (XRF) and X-ray photoelectron spectroscopy (XPS) results.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Quantitative Surface Characterization of Silicon Spheres by Combined X-Ray Fluorescence Analysis and X-Ray Photoelectron Spectroscopy Measurements
The future realization of the kilogram as the SI base unit of mass, by monocrystalline enriched 28 Si-spheres requires a reliable surface analysis of silicon spheres. An analytical instrument with complementary spectroscopic techniques is used for a quantitative surface characterization of such spheres. In particular, the mass deposition and the composition of the surface layer are measured. The presented principles of the quantification combine X-ray fluorescence spectroscopy (XRF) and X-ray photoelectron spectroscopy (XPS) results.