Wenshan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wenshan Li has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Guoxing Jing
Xiangtan University
8 shared publicationsJianna Yu
Xiangtan University
8 shared publicationsWen Liu
7 shared publicationsWenjie Liu
6 shared publicationsHuaiyue Xia
College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
3 shared publications- Wenjie Liu
Xiangtan University
3 shared publications
Latest Publications
- 7 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 30906-30914
Efficient Separation of Disaccharide Isomers Using Ion Mobility Spectrometry by Metal Cation and Anion Assisted Strategy
The rapid separation and identification of disaccharide isomers pose a significant analytical challenge in fields such as food science and glycobiology. This study developed a fast, simple, and low-cost analytical method based on electrospray ionization ion mobility spectrometry (ESI-IMS) combined with an ion adduction strategy for the efficient separation of eight common disaccharide isomers. The principle involves introducing specific metal cations or anions into the disaccharide solution to form stable adducts, thereby significantly altering their drift behavior during IMS analysis. Systematic screening of seven cations and nine anions and mass spectrometry result revealed that in positive ion mode, Cu+ forms structurally rigid dimeric adducts [Cu + 2M]+ with disaccharides, effectively amplifying subtle stereostructural differences into significant distinctions in collision cross section (CCS) and increasing the proportion of fully separated disaccharide pairs to 71.4%. In negative ion mode, I− forms predominantly single [I + M]− adducts, substantially simplifying the complex original spectra and achieving a full separation rate of 60.7%. Theoretical calculations indicated stable electronic structures within the complex systems and the differences in both the strength and interaction characteristics between the two types of adducts. This method requires no complex pretreatment or expensive advanced instrumentation, and is readily implementable on conventional drift-tube IMS platforms. It thus offers a robust, cost-effective, and high-throughput solution for disaccharide isomer analysis, with potential applications in food science, biomedicine, and materials characterization.
- 7 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 30906-30914
Efficient Separation of Disaccharide Isomers Using Ion Mobility Spectrometry by Metal Cation and Anion Assisted Strategy
The rapid separation and identification of disaccharide isomers pose a significant analytical challenge in fields such as food science and glycobiology. This study developed a fast, simple, and low-cost analytical method based on electrospray ionization ion mobility spectrometry (ESI-IMS) combined with an ion adduction strategy for the efficient separation of eight common disaccharide isomers. The principle involves introducing specific metal cations or anions into the disaccharide solution to form stable adducts, thereby significantly altering their drift behavior during IMS analysis. Systematic screening of seven cations and nine anions and mass spectrometry result revealed that in positive ion mode, Cu+ forms structurally rigid dimeric adducts [Cu + 2M]+ with disaccharides, effectively amplifying subtle stereostructural differences into significant distinctions in collision cross section (CCS) and increasing the proportion of fully separated disaccharide pairs to 71.4%. In negative ion mode, I− forms predominantly single [I + M]− adducts, substantially simplifying the complex original spectra and achieving a full separation rate of 60.7%. Theoretical calculations indicated stable electronic structures within the complex systems and the differences in both the strength and interaction characteristics between the two types of adducts. This method requires no complex pretreatment or expensive advanced instrumentation, and is readily implementable on conventional drift-tube IMS platforms. It thus offers a robust, cost-effective, and high-throughput solution for disaccharide isomer analysis, with potential applications in food science, biomedicine, and materials characterization.
- Open Access
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
Synergistic Oxidative and Electric Field Effects in Fungal Membrane Disruption by Cold Atmospheric Plasma: A Multi-Scale Experimental and Simulation Study
Postharvest fungal infections cause substantial economic losses and food safety concerns globally. Cold atmospheric plasma (CAP), which generates reactive species and electric fields, has shown promising potential as a green fungicide alternative. This study combined experiments and molecular dynamics (MD) simulations to elucidate the mechanism of fungal cell membrane disruption by CAP. Experimental results demonstrated that CAP significantly inhibited Penicillium expansum spore germination and colony formation, induced leakage of nucleic acids and proteins, elevated malondialdehyde (MDA) content, and caused severe membrane damage. To unravel the atomic-scale process, a fungal-specific membrane model composed of POPC and ergosterol was constructed. Simulations revealed that oxidation of POPC and ergosterol significantly reduced membrane order, increased potential and density. The coexistence of POPC-ALC and EEP exhibited a strong synergistic effect, leading to the highest membrane instability. Under an external electric field (0.6 V/nm), oxidized membranes showed markedly accelerated electroporation kinetics. Additionally, the distribution of reactive oxygen species (ROS) within the membrane was significantly altered, indicating enhanced penetration. This work provides systematic atomic-scale insight into the CAP-induced disruption of fungal membranes via synergistic oxidative and electric field effects, revealing the electroporation mechanism at the plasma-bioelectrochemical interface and offering a theoretical basis for developing membrane-targeted antifungal strategies.
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSynergistic Oxidative and Electric Field Effects in Fungal Membrane Disruption by Cold Atmospheric Plasma: A Multi-Scale Experimental and Simulation Study
Postharvest fungal infections cause substantial economic losses and food safety concerns globally. Cold atmospheric plasma (CAP), which generates reactive species and electric fields, has shown promising potential as a green fungicide alternative. This study combined experiments and molecular dynamics (MD) simulations to elucidate the mechanism of fungal cell membrane disruption by CAP. Experimental results demonstrated that CAP significantly inhibited Penicillium expansum spore germination and colony formation, induced leakage of nucleic acids and proteins, elevated malondialdehyde (MDA) content, and caused severe membrane damage. To unravel the atomic-scale process, a fungal-specific membrane model composed of POPC and ergosterol was constructed. Simulations revealed that oxidation of POPC and ergosterol significantly reduced membrane order, increased potential and density. The coexistence of POPC-ALC and EEP exhibited a strong synergistic effect, leading to the highest membrane instability. Under an external electric field (0.6 V/nm), oxidized membranes showed markedly accelerated electroporation kinetics. Additionally, the distribution of reactive oxygen species (ROS) within the membrane was significantly altered, indicating enhanced penetration. This work provides systematic atomic-scale insight into the CAP-induced disruption of fungal membranes via synergistic oxidative and electric field effects, revealing the electroporation mechanism at the plasma-bioelectrochemical interface and offering a theoretical basis for developing membrane-targeted antifungal strategies.
- 22 March 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1256, 341123
Target-activated multivalent sensing platform for improving the sensitivity and selectivity of Hg2+ detection
- 22 March 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1256, 341123
Target-activated multivalent sensing platform for improving the sensitivity and selectivity of Hg2+ detection
- 14 November 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1237, 340616
Colorimetric aptasensor for the sensitive detection of ochratoxin A based on a triple cascade amplification strategy
- 14 November 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1237, 340616
Colorimetric aptasensor for the sensitive detection of ochratoxin A based on a triple cascade amplification strategy
- Open Access
Miniaturized Photo-Ionization Fourier Deconvolution Ion Mobility Spectrometer for the Detection of Volatile Organic Compounds
Because of its simplicity, reliability, and sensitivity, the drift tube ion mobility spectrometer (IMS) has been recognized as the equipment of choice for the on-site monitoring and identification of volatile organic compounds (VOCs). However, the performance of handheld IMS is often limited by the size, weight, and drift voltage, which heavily determine the sensitivity and resolving power that is crucial for the detection and identification of VOCs. In this work, we present a low-cost, miniaturized drift tube ion mobility spectrometer incorporated with a miniaturized UV ionization lamp and a relatively low drift voltage. The sensitivity and resolving power are boosted with the implementation of Fourier deconvolution multiplexing compared to the conventional signal averaging data acquisition method. The drift tube provides a high resolving power of up to 52 at a drift length of 41 mm, 10 mm ID dimensions, and a drift voltage of 1.57 kV. Acetone, benzene, dimethyl methyl phosphonate, methyl salicylate, and acetic acid were evaluated in the developed spectrometer and showed satisfactory performance.
Open AccessMiniaturized Photo-Ionization Fourier Deconvolution Ion Mobility Spectrometer for the Detection of Volatile Organic Compounds
Because of its simplicity, reliability, and sensitivity, the drift tube ion mobility spectrometer (IMS) has been recognized as the equipment of choice for the on-site monitoring and identification of volatile organic compounds (VOCs). However, the performance of handheld IMS is often limited by the size, weight, and drift voltage, which heavily determine the sensitivity and resolving power that is crucial for the detection and identification of VOCs. In this work, we present a low-cost, miniaturized drift tube ion mobility spectrometer incorporated with a miniaturized UV ionization lamp and a relatively low drift voltage. The sensitivity and resolving power are boosted with the implementation of Fourier deconvolution multiplexing compared to the conventional signal averaging data acquisition method. The drift tube provides a high resolving power of up to 52 at a drift length of 41 mm, 10 mm ID dimensions, and a drift voltage of 1.57 kV. Acetone, benzene, dimethyl methyl phosphonate, methyl salicylate, and acetic acid were evaluated in the developed spectrometer and showed satisfactory performance.