Suraj Thyagaraj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Suraj Thyagaraj has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
Francis Loth
Department of Mechanical Engineering, Conquer Chiari Research Center, University of Akron, Akron, USA
8 shared publicationsAlexander C. Bunck
Department of Radiology, University Hospital of Cologne, Cologne, Germany
5 shared publications- Bryn A. Martin
Department of Chemical and Biological Engineering, University of Idaho, Moscow, ID, United States
4 shared publications Soroush Heidari Pahlavian
University of Akron
4 shared publicationsJohn Oshinski
Department of Radiology and Imaging Sciences, Emory University, Atlanta, USA
3 shared publicationsJun Yang
Department of Neurosurgery, Cleveland Clinic Foundation, Cleveland, Ohio
3 shared publications
Latest Publications
- 1 December 2025
- Published by Wolters Kluwer Health in Neurology Clinical Practice
- Vol. 15 (6) , e200559
Localizing and Lateralizing Significance of Initial, Mid-Ictal, and Ictal-End Head Position in Versive Seizures With Secondary Generalization
The aim of this study was to assess the localizing and lateralizing significance of initial, mid-ictal, and ictal-end head position in versive seizures with secondary generalization. We analyzed video-EEG recordings of 65 patients with focal epilepsy for various head position changes during version evolving into secondary generalized tonic-clonic (GTC) seizure. We calculated the latency of version from seizure onset and the latency of secondary generalization from version. We excluded patients with generalized epilepsy. The latency of version from seizure onset (T1) was 46.7 ± 8.8 sec and 24.1 ± 8.2 sec in temporal and frontal lobe groups, respectively (p < 0.0001). Occipital seizures had the longest latency of 77.8 ± 42.9 sec (p = 0.0002). The latency of secondary GTC seizures (T4) from initial version was 15.7 ± 3.2 sec in the temporal lobe group, compared with 18.3 ± 5.7 sec in the frontal lobe group (p = 0.03) and 18.8 ± 9.3 sec (p = 0.13) in the parietal lobe group. Occipital seizures had the shortest latency at 9.8 ± 3.9 sec (p = 0.0001). In 57 of 65 patients, the head position evolved to a primary midline position from the initial version. In 24 of 65 patients, the head position further evolved to an ictal-end position by the end of the GTC phase. In these 24 patients, the ictal-end head position was contralateral to the direction of initial version in 100% of cases, and hence ipsilateral to the epileptogenic zone. In total, 13 of these 24 patients also had corresponding ipsilateral ictal-end clonic movement. Latency of onset of the initial version has a localizing significance for the epileptogenic zone, with the shortest latency for frontal seizures and the longest for occipital seizures. This is consistent with the relative distance of the frontal eye field from these seizure-onset zones. An ictal-end head position contralateral to the initial version occurs in approximately 37% of focal epilepsies and is always ipsilateral to the epileptogenic zone.
- 1 December 2025
- Published by Wolters Kluwer Health in Neurology Clinical Practice
- Vol. 15 (6) , e200559
Localizing and Lateralizing Significance of Initial, Mid-Ictal, and Ictal-End Head Position in Versive Seizures With Secondary Generalization
The aim of this study was to assess the localizing and lateralizing significance of initial, mid-ictal, and ictal-end head position in versive seizures with secondary generalization. We analyzed video-EEG recordings of 65 patients with focal epilepsy for various head position changes during version evolving into secondary generalized tonic-clonic (GTC) seizure. We calculated the latency of version from seizure onset and the latency of secondary generalization from version. We excluded patients with generalized epilepsy. The latency of version from seizure onset (T1) was 46.7 ± 8.8 sec and 24.1 ± 8.2 sec in temporal and frontal lobe groups, respectively (p < 0.0001). Occipital seizures had the longest latency of 77.8 ± 42.9 sec (p = 0.0002). The latency of secondary GTC seizures (T4) from initial version was 15.7 ± 3.2 sec in the temporal lobe group, compared with 18.3 ± 5.7 sec in the frontal lobe group (p = 0.03) and 18.8 ± 9.3 sec (p = 0.13) in the parietal lobe group. Occipital seizures had the shortest latency at 9.8 ± 3.9 sec (p = 0.0001). In 57 of 65 patients, the head position evolved to a primary midline position from the initial version. In 24 of 65 patients, the head position further evolved to an ictal-end position by the end of the GTC phase. In these 24 patients, the ictal-end head position was contralateral to the direction of initial version in 100% of cases, and hence ipsilateral to the epileptogenic zone. In total, 13 of these 24 patients also had corresponding ipsilateral ictal-end clonic movement. Latency of onset of the initial version has a localizing significance for the epileptogenic zone, with the shortest latency for frontal seizures and the longest for occipital seizures. This is consistent with the relative distance of the frontal eye field from these seizure-onset zones. An ictal-end head position contralateral to the initial version occurs in approximately 37% of focal epilepsies and is always ipsilateral to the epileptogenic zone.
- Open Access
Machine Learning Interpretability Methods to Characterize Brain Network Dynamics in Epilepsy
The rapid adoption of machine learning (ML) algorithms in a wide range of biomedical applications has highlighted issues of trust and the lack of understanding regarding the results generated by ML algorithms. Recent studies have focused on developing interpretable ML models and establish guidelines for transparency and ethical use, ensuring the responsible integration of machine learning in healthcare. In this study, we demonstrate the effectiveness of ML interpretability methods to provide important insights into the dynamics of brain network interactions in epilepsy, a serious neurological disorder affecting more than 60 million persons worldwide. Using high-resolution intracranial electroencephalogram (EEG) recordings from a cohort of 16 patients, we developed high accuracy ML models to categorize these brain activity recordings into either seizure or non-seizure classes followed by a more complex task of delineating the different stages of seizure progression to different parts of the brain as a multi-class classification task. We applied three distinct types of interpretability methods to the high-accuracy ML models to gain an understanding of the relative contributions of different categories of brain interaction patterns, including multi-focii interactions, which play an important role in distinguishing between different states of the brain. The results of this study demonstrate for the first time that post-hoc interpretability methods enable us to understand why ML algorithms generate a given set of results and how variations in value of input values affect the accuracy of the ML algorithms. In particular, we show in this study that interpretability methods can be used to identify brain regions and interaction patterns that have a significant impact on seizure events. The results of this study highlight the importance of the integrated implementation of ML algorithms together with interpretability methods in aberrant brain network studies and the wider domain of biomedical research.
Open AccessMachine Learning Interpretability Methods to Characterize Brain Network Dynamics in Epilepsy
The rapid adoption of machine learning (ML) algorithms in a wide range of biomedical applications has highlighted issues of trust and the lack of understanding regarding the results generated by ML algorithms. Recent studies have focused on developing interpretable ML models and establish guidelines for transparency and ethical use, ensuring the responsible integration of machine learning in healthcare. In this study, we demonstrate the effectiveness of ML interpretability methods to provide important insights into the dynamics of brain network interactions in epilepsy, a serious neurological disorder affecting more than 60 million persons worldwide. Using high-resolution intracranial electroencephalogram (EEG) recordings from a cohort of 16 patients, we developed high accuracy ML models to categorize these brain activity recordings into either seizure or non-seizure classes followed by a more complex task of delineating the different stages of seizure progression to different parts of the brain as a multi-class classification task. We applied three distinct types of interpretability methods to the high-accuracy ML models to gain an understanding of the relative contributions of different categories of brain interaction patterns, including multi-focii interactions, which play an important role in distinguishing between different states of the brain. The results of this study demonstrate for the first time that post-hoc interpretability methods enable us to understand why ML algorithms generate a given set of results and how variations in value of input values affect the accuracy of the ML algorithms. In particular, we show in this study that interpretability methods can be used to identify brain regions and interaction patterns that have a significant impact on seizure events. The results of this study highlight the importance of the integrated implementation of ML algorithms together with interpretability methods in aberrant brain network studies and the wider domain of biomedical research.
- 1 February 2023
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 134 (2) , 242-252
Modifying the ICP pulse wave: effects on parenchymal blood flow pulsatility
This study demonstrated that external modification of ICP pulsatility, using a cardiac-gated inflatable device implanted epidurally in canines, alters brain tissue blood flow pulsatility. Specifically, decreasing systolic ICP increased blood flow pulsatility in brain tissue. The results suggest that the altered CBF pulsatility is unlikely to depend on modification of the Windkessel effect on the feeding arterial system but was rather an effect directly on tissue and the lower pressure distal vessels.
- 1 February 2023
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 134 (2) , 242-252
Modifying the ICP pulse wave: effects on parenchymal blood flow pulsatility
This study demonstrated that external modification of ICP pulsatility, using a cardiac-gated inflatable device implanted epidurally in canines, alters brain tissue blood flow pulsatility. Specifically, decreasing systolic ICP increased blood flow pulsatility in brain tissue. The results suggest that the altered CBF pulsatility is unlikely to depend on modification of the Windkessel effect on the feeding arterial system but was rather an effect directly on tissue and the lower pressure distal vessels.
- 1 April 2022
- Published by Wiley in Epileptic Disorders
- Vol. 24 (2) , 417-421
Epileptic negative myoclonus in herpes simplex virus encephalitis
Epileptic negative myoclonus (ENM) is a rarely reported clinical seizure semiology. It is defined as a brief interruption of tonic muscle activity in association with an epileptiform discharge on the EEG (spike or sharp wave) without preceding myoclonia. The diagnosis of ENM requires a polygraphic recording with EEG and surface EMG electrodes covering the affected body part(s), while the muscles have tonic activity. Historically, ENM has been reported in a variety of chronic epilepsy syndromes such as benign epilepsy with centrotemporal spikes, progressive myoclonic epilepsy syndromes, symptomatic partial epilepsy syndromes due to structural pathologies, cryptogenic epilepsies, etc. In this paper, we report a patient with herpes simplex virus encephalitis who presented with multiple different seizure types including ENM. The patient showed significant improvement after treatment with acyclovir.
- 1 April 2022
- Published by Wiley in Epileptic Disorders
- Vol. 24 (2) , 417-421
Epileptic negative myoclonus in herpes simplex virus encephalitis
Epileptic negative myoclonus (ENM) is a rarely reported clinical seizure semiology. It is defined as a brief interruption of tonic muscle activity in association with an epileptiform discharge on the EEG (spike or sharp wave) without preceding myoclonia. The diagnosis of ENM requires a polygraphic recording with EEG and surface EMG electrodes covering the affected body part(s), while the muscles have tonic activity. Historically, ENM has been reported in a variety of chronic epilepsy syndromes such as benign epilepsy with centrotemporal spikes, progressive myoclonic epilepsy syndromes, symptomatic partial epilepsy syndromes due to structural pathologies, cryptogenic epilepsies, etc. In this paper, we report a patient with herpes simplex virus encephalitis who presented with multiple different seizure types including ENM. The patient showed significant improvement after treatment with acyclovir.
- 1 October 2021
- Published by Wiley in Epileptic Disorders
- Vol. 23 (5) , 682-694
Stereotactic‐EEG‐guided radiofrequency multiple hippocampal transection (SEEG‐guided‐RF‐MHT) for the treatment of mesial temporal lobe epilepsy: a minimally invasive method for diagnosis and treatment
Objective. For the treatment of mesial temporal lobe epilepsy on the language‐dominant side in patients at high risk of memory decline, we propose a minimally invasive diagnostic and treatment technique, adopting the principles of multiple hippocampal transections (MHT) using stereo‐electroencephalography‐guided radiofrequency (SEEG‐guided‐RF‐MHT). This new technique allows targeting of the longitudinal fibers in the hippocampus critical for seizure spreading, while sparing the transverse circuits which are considered important for memory processing and avoiding discomfort and longer post‐operatory recovery time associated with craniotomies. We report the efficacy and safety of this procedure in a preliminary observational study of cases.Methods. Five patients at high risk of memory decline, including three with non‐lesional hippocampi on MRI, had temporal lobe epilepsy (TLE) necessitating depth electrode implantation. A new strategy of SEEG electrode placement was used to mimic MHT. After confirming hippocampal seizure onset, all the patients had three linear ablations perpendicular to the amigdalohippocampal complex. The procedure was performed at the patient's bedside with the patient awake during the full length of the procedure.Results. Four out of five patients were seizure‐free (average follow up: 14–18 months). There were no associated complications. Visual inspection of brain MRI of patients at six months following SEEG‐guided RF‐MHT showed significant hippocampal volume preservation. Subjects who received the procedure in the dominant side reported no subjective memory complaints in the follow‐up clinic assessments at six months.Significance. Our preliminary seizure outcome seems very promising since the majority of our patients (four out of five patients) were seizure‐free. Since no lesions are made outside the amygdalo‐hippocampal complex using this technique and the temporal stem remains intact, more favorable memory and language outcome is expected in patients at high risk of memory decline.
- 1 October 2021
- Published by Wiley in Epileptic Disorders
- Vol. 23 (5) , 682-694
Stereotactic‐EEG‐guided radiofrequency multiple hippocampal transection (SEEG‐guided‐RF‐MHT) for the treatment of mesial temporal lobe epilepsy: a minimally invasive method for diagnosis and treatment
Objective. For the treatment of mesial temporal lobe epilepsy on the language‐dominant side in patients at high risk of memory decline, we propose a minimally invasive diagnostic and treatment technique, adopting the principles of multiple hippocampal transections (MHT) using stereo‐electroencephalography‐guided radiofrequency (SEEG‐guided‐RF‐MHT). This new technique allows targeting of the longitudinal fibers in the hippocampus critical for seizure spreading, while sparing the transverse circuits which are considered important for memory processing and avoiding discomfort and longer post‐operatory recovery time associated with craniotomies. We report the efficacy and safety of this procedure in a preliminary observational study of cases.Methods. Five patients at high risk of memory decline, including three with non‐lesional hippocampi on MRI, had temporal lobe epilepsy (TLE) necessitating depth electrode implantation. A new strategy of SEEG electrode placement was used to mimic MHT. After confirming hippocampal seizure onset, all the patients had three linear ablations perpendicular to the amigdalohippocampal complex. The procedure was performed at the patient's bedside with the patient awake during the full length of the procedure.Results. Four out of five patients were seizure‐free (average follow up: 14–18 months). There were no associated complications. Visual inspection of brain MRI of patients at six months following SEEG‐guided RF‐MHT showed significant hippocampal volume preservation. Subjects who received the procedure in the dominant side reported no subjective memory complaints in the follow‐up clinic assessments at six months.Significance. Our preliminary seizure outcome seems very promising since the majority of our patients (four out of five patients) were seizure‐free. Since no lesions are made outside the amygdalo‐hippocampal complex using this technique and the temporal stem remains intact, more favorable memory and language outcome is expected in patients at high risk of memory decline.
- Open Access
- 18 March 2021
- Published by Springer Nature in Fluids and Barriers of the CNS
- Vol. 18 (1) , 1-15
In vitro evaluation of cerebrospinal fluid velocity measurement in type I Chiari malformation: repeatability, reproducibility, and agreement using 2D phase contrast and 4D flow MRI
Background: Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed. Methods: An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. Results: Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals ± 1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). Conclusion: Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases.
- 18 March 2021
- Published by Springer Nature in Fluids and Barriers of the CNS
- Vol. 18 (1) , 1-15
Open AccessIn vitro evaluation of cerebrospinal fluid velocity measurement in type I Chiari malformation: repeatability, reproducibility, and agreement using 2D phase contrast and 4D flow MRI
Background: Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed. Methods: An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. Results: Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals ± 1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). Conclusion: Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases.
- Open Access
- 26 January 2021
- Published by Springer Nature in Research Square
In Vitro Evaluation of Cerebrospinal Fluid Velocity Measurement Agreement, Reliability, and Reproducibility in Type I Chiari Malformation Using 2D Phase Contrast Magnetic Resonance Imaging and 4D Flow Imaging
Background: Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed.Methods: An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. Results: Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals ±1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). Conclusion: Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases.
- 26 January 2021
- Published by Springer Nature in Research Square
Open AccessIn Vitro Evaluation of Cerebrospinal Fluid Velocity Measurement Agreement, Reliability, and Reproducibility in Type I Chiari Malformation Using 2D Phase Contrast Magnetic Resonance Imaging and 4D Flow Imaging
Background: Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed.Methods: An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. Results: Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals ±1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). Conclusion: Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases.
- 13 June 2020
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 87 (6) , 1299-1310
Epidural Oscillating Cardiac-Gated Intracranial Implant Modulates Cerebral Blood Flow
Background: We have previously reported a method and device capable of manipulating ICP pulsatility while minimally effecting mean ICP. Objective: To test the hypothesis that different modulations of the intracranial pressure (ICP) pulse waveform will have a differential effect on cerebral blood flow (CBF). Methods: Using an epidural balloon catheter attached to a cardiac-gated oscillating pump, 13 canine subjects underwent ICP waveform manipulation comparing different sequences of oscillation in successive animals. The epidural balloon was implanted unilaterally superior to the Sylvian sulcus. Subjects underwent ICP pulse augmentation, reduction and inversion protocols, directly comparing time segments of system activation and deactivation. ICP and CBF were measured bilaterally along with systemic pressure and heart rate. CBF was measured using both thermal diffusion, and laser doppler probes. Results: The activation of the cardiac-gate balloon implant resulted in an ipsilateral/contralateral ICP pulse amplitude increase with augmentation (217%/202% respectively, P < .0005) and inversion (139%/120%, P < .0005). The observed changes associated with the ICP mean values were smaller, increasing with augmentation (23%/31%, P < .0001) while decreasing with inversion (7%/11%, P = .006/.0003) and reduction (4%/5%, P < .0005). CBF increase was observed for both inversion and reduction protocols (28%/7.4%, P < .0001/P = .006 and 2.4%/1.3%, P < .0001/P = .003), but not the augmentation protocol. The change in CBF was correlated with ICP pulse amplitude and systolic peak changes and not with change in mean ICP or systemic variables (heart rate, arterial blood pressure). Conclusion: Cardiac-gated manipulation of ICP pulsatility allows the study of intracranial pulsatile dynamics and provides a potential means of altering CBF.
- 13 June 2020
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 87 (6) , 1299-1310
Epidural Oscillating Cardiac-Gated Intracranial Implant Modulates Cerebral Blood Flow
Background: We have previously reported a method and device capable of manipulating ICP pulsatility while minimally effecting mean ICP. Objective: To test the hypothesis that different modulations of the intracranial pressure (ICP) pulse waveform will have a differential effect on cerebral blood flow (CBF). Methods: Using an epidural balloon catheter attached to a cardiac-gated oscillating pump, 13 canine subjects underwent ICP waveform manipulation comparing different sequences of oscillation in successive animals. The epidural balloon was implanted unilaterally superior to the Sylvian sulcus. Subjects underwent ICP pulse augmentation, reduction and inversion protocols, directly comparing time segments of system activation and deactivation. ICP and CBF were measured bilaterally along with systemic pressure and heart rate. CBF was measured using both thermal diffusion, and laser doppler probes. Results: The activation of the cardiac-gate balloon implant resulted in an ipsilateral/contralateral ICP pulse amplitude increase with augmentation (217%/202% respectively, P < .0005) and inversion (139%/120%, P < .0005). The observed changes associated with the ICP mean values were smaller, increasing with augmentation (23%/31%, P < .0001) while decreasing with inversion (7%/11%, P = .006/.0003) and reduction (4%/5%, P < .0005). CBF increase was observed for both inversion and reduction protocols (28%/7.4%, P < .0001/P = .006 and 2.4%/1.3%, P < .0001/P = .003), but not the augmentation protocol. The change in CBF was correlated with ICP pulse amplitude and systolic peak changes and not with change in mean ICP or systemic variables (heart rate, arterial blood pressure). Conclusion: Cardiac-gated manipulation of ICP pulsatility allows the study of intracranial pulsatile dynamics and provides a potential means of altering CBF.
- 1 June 2020
- Published by Elsevier in Journal of Psychiatric Research
- Vol. 125, 113-120
Connectivity-based identification of a potential neurosurgical target for mood disorders
- 1 June 2020
- Published by Elsevier in Journal of Psychiatric Research
- Vol. 125, 113-120
Connectivity-based identification of a potential neurosurgical target for mood disorders
- 2 July 2019
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 86 (5) , 724-735
Clinical Evaluation of Cingulum Bundle Connectivity for Neurosurgical Hypothesis Development
BACKGROUND: The cingulum bundle (CB) has long been a target for psychiatric neurosurgical procedures, but with limited understanding of the brain networks being impacted. Recent advances in human tractography could provide a foundation to better understand the effects of neurosurgical interventions on the CB; however, the reliability of tractography remains in question. OBJECTIVE: To evaluate the ability of different tractography techniques, derived from typical, human diffusion-weighted imaging (DWI) data, to characterize CB connectivity described in animal models. This will help validate the clinical applicability of tractography, and generate insight on current and future neurosurgical targets for psychiatric disorders. METHODS: Connectivity of the CB in 15 healthy human subjects was evaluated using DWI-based tractography, and compared to tract-tracing findings from nonhuman primates. Brain regions of interest were defined to coincide with the animal model. Tractography was performed using 3 techniques (FSL probabilistic, Camino probabilistic, and Camino deterministic). Differences in connectivity were assessed, and the CB segment with the greatest connectivity was determined. RESULTS: Each tractography technique successfully reproduced the animal tracing model with a mean accuracy of 72% (68-75%, P < .05). Additionally, one region of the CB, the rostral dorsal segment, had significantly greater connectivity to associated brain structures than all other CB segments (P < .05). CONCLUSION: Noninvasive, in vivo human analysis of the CB, using clinically available DWI for tractography, consistently reproduced the results of an animal tract-tracing model. This suggests that tractography of the CB can be used for clinical applications, which may aid in neurosurgical targeting for psychiatric disorders.
- 2 July 2019
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 86 (5) , 724-735
Clinical Evaluation of Cingulum Bundle Connectivity for Neurosurgical Hypothesis Development
BACKGROUND: The cingulum bundle (CB) has long been a target for psychiatric neurosurgical procedures, but with limited understanding of the brain networks being impacted. Recent advances in human tractography could provide a foundation to better understand the effects of neurosurgical interventions on the CB; however, the reliability of tractography remains in question. OBJECTIVE: To evaluate the ability of different tractography techniques, derived from typical, human diffusion-weighted imaging (DWI) data, to characterize CB connectivity described in animal models. This will help validate the clinical applicability of tractography, and generate insight on current and future neurosurgical targets for psychiatric disorders. METHODS: Connectivity of the CB in 15 healthy human subjects was evaluated using DWI-based tractography, and compared to tract-tracing findings from nonhuman primates. Brain regions of interest were defined to coincide with the animal model. Tractography was performed using 3 techniques (FSL probabilistic, Camino probabilistic, and Camino deterministic). Differences in connectivity were assessed, and the CB segment with the greatest connectivity was determined. RESULTS: Each tractography technique successfully reproduced the animal tracing model with a mean accuracy of 72% (68-75%, P < .05). Additionally, one region of the CB, the rostral dorsal segment, had significantly greater connectivity to associated brain structures than all other CB segments (P < .05). CONCLUSION: Noninvasive, in vivo human analysis of the CB, using clinically available DWI for tractography, consistently reproduced the results of an animal tract-tracing model. This suggests that tractography of the CB can be used for clinical applications, which may aid in neurosurgical targeting for psychiatric disorders.