Background: Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed. Methods: An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. Results: Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals ± 1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). Conclusion: Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases.Keywords
All Related Versions
Funding Information
- National Institute of Neurological Disorders and Stroke (R01NS111283)
- National Institute of General Medical Sciences (P20GM1033408, 4U54GM104944-04TBD)
- National Center for Advancing Translational Sciences (UL1TR002378)
This publication has 62 references indexed in Scilit:
- Development of Common Data Elements for Use in Chiari Malformation Type I Clinical Research: An NIH/NINDS ProjectNeurosurgery, 2019
- Does Phase-Contrast Imaging through the Cerebral Aqueduct Predict the Outcome of Lumbar CSF Drainage or Shunt Surgery in Patients with Suspected Adult Hydrocephalus?American Journal of Neuroradiology, 2018
- 4D flow MRI quantification of mitral and tricuspid regurgitation: Reproducibility and consistency relative to conventional MRIJournal of Magnetic Resonance Imaging, 2018
- Quantifying the influence of respiration and cardiac pulsations on cerebrospinal fluid dynamics using real‐time phase‐contrast MRIJournal of Magnetic Resonance Imaging, 2017
- 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiographyPediatric Radiology, 2014
- Hydrodynamic and Longitudinal Impedance Analysis of Cerebrospinal Fluid Dynamics at the Craniovertebral Junction in Type I Chiari MalformationPLOS ONE, 2013
- Comparison of 4D Phase-Contrast MRI Flow Measurements to Computational Fluid Dynamics Simulations of Cerebrospinal Fluid Motion in the Cervical SpinePLOS ONE, 2012
- Peak CSF Velocities in Patients with Symptomatic and Asymptomatic Chiari I MalformationAmerican Journal of Neuroradiology, 2010
- Hepatic vascular flow measurements by phase contrast MRI and doppler echography: A comparative and reproducibility studyJournal of Magnetic Resonance Imaging, 2010
- Correlation of hindbrain CSF flow and outcome after surgical decompression for Chiari I malformationChild's Nervous System, 2008