Se Min Chun
Research Subjects
Se Min Chun has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Yong Cheol Hong
Institute of Plasma Technology Research, Korea Institute of Fusion Energy, Gunsan, South Korea
4 shared publications - Geon Woo Yang
Institute of Plasma Technology, 37 Dongjansan-ro, Gunsan 54004, Republic of Korea
3 shared publications - Dong Hun Shin
Plasma Technology Research Center, National Fusion Research Institute, 37 Dongjansan-ro, Gunsan, Jeollabuk-do 54004, Korea
2 shared publications - Suk Hwal Ma
Plasma Technology Research Center, National Fusion Research Institute, 37 Dongjansan-ro, Gunsan, Jeollabuk-do 54004, Korea
2 shared publications - Geon Woo Yang
Plasma Technology Research Center, National Fusion Research Institute, 37 Dongjansan-ro, Gunsan, Jeollabuk-do 54004, Korea
1 shared publication - Geum Ran Ahn
Institute of Plasma Technology, Korea Institute of Fusion Energy (KFE), 37 Dongjansan-ro, Gunsan 54004, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 14 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12302
Sterilization of Water-Based Cutting Fluids Using Compact Air-Cooled Coaxial Dielectric Barrier Discharge Reactor with Bubbler
Odor and discoloration in water-based cutting fluids are caused by the growth of microorganisms and putrefying bacteria. This significantly reduces cutting performance, prevents rust, and deteriorates the working environment. To overcome these drawbacks, we developed a compact air-cooled coaxial dielectric barrier discharge (DBD) with a bubbler. Bacteria and microorganisms living in waste cutting fluids were sterilized by the high concentration of ozone produced under the optimized conditions of the compact air-cooled coaxial DBD. Moreover, it was confirmed that 99.99% of bacteria and microorganisms were completely removed. Ozone was found to not affect property changes such as the composition, concentration, and pH of the water-based cutting fluids. The chromaticity and complex odor of waste cutting liquids were thus found to have been improved by the effects of microorganism and bacterial sterilization. We conclude that the proposed a compact air-cooled coaxial DBD with a bubbler is an efficient method for sterilizing water-based cutting fluids.
- 14 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12302
Open AccessSterilization of Water-Based Cutting Fluids Using Compact Air-Cooled Coaxial Dielectric Barrier Discharge Reactor with Bubbler
Odor and discoloration in water-based cutting fluids are caused by the growth of microorganisms and putrefying bacteria. This significantly reduces cutting performance, prevents rust, and deteriorates the working environment. To overcome these drawbacks, we developed a compact air-cooled coaxial dielectric barrier discharge (DBD) with a bubbler. Bacteria and microorganisms living in waste cutting fluids were sterilized by the high concentration of ozone produced under the optimized conditions of the compact air-cooled coaxial DBD. Moreover, it was confirmed that 99.99% of bacteria and microorganisms were completely removed. Ozone was found to not affect property changes such as the composition, concentration, and pH of the water-based cutting fluids. The chromaticity and complex odor of waste cutting liquids were thus found to have been improved by the effects of microorganism and bacterial sterilization. We conclude that the proposed a compact air-cooled coaxial DBD with a bubbler is an efficient method for sterilizing water-based cutting fluids.
- 1 September 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (9) , 093502
Simulated experiments for removal of odorous gases by wire-mesh electrode dielectric barrier discharge
The emission of odorous gases from various industrial processes such as factories and wastewater treatment, in addition to emissions from landfills and livestock, has become a public concern because of their negative effect on air quality and human health. This study presents a technology based on dielectric barrier discharge (DBD) of wire-mesh type with a high-voltage electric wire as the electrode. This system was used to experimentally assess the removal efficiency of odorous gases. The plasma system consists of a wire electrode with a mesh-type configuration, a small blower (1.6 N m3/min, compressed air) for the plasma discharge or to supply cooling gas, and an AC high-voltage power supply. The plasma system offers the advantages of low power consumption and a large discharge area for ozone production. The wire-mesh electrode DBD comprises 64 discharge nodes, and the large amount of ozone generated from these nodes is used to oxidize odorous gases. Under optimized conditions, ozone is stably generated at the rate of 5.1 g/h for a specific input energy of 3.7 J/L. The ozone and odorous compounds (H2S: 4.5 ppm, CH3SH: 6.7 ppm, NH3: 3 ppm, outlet concentration) are injected into the main blower (20 N m3/min, compressed air). Finally, the experiments designed to simulate the removal of odorous gases confirmed that 99% of odorous compounds were removed using the wire-mesh electrode DBD. The cost-effectiveness and scalability of this system make it highly suitable for use in industrial environments where odorous gases are produced.
- 1 September 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (9) , 093502
Simulated experiments for removal of odorous gases by wire-mesh electrode dielectric barrier discharge
The emission of odorous gases from various industrial processes such as factories and wastewater treatment, in addition to emissions from landfills and livestock, has become a public concern because of their negative effect on air quality and human health. This study presents a technology based on dielectric barrier discharge (DBD) of wire-mesh type with a high-voltage electric wire as the electrode. This system was used to experimentally assess the removal efficiency of odorous gases. The plasma system consists of a wire electrode with a mesh-type configuration, a small blower (1.6 N m3/min, compressed air) for the plasma discharge or to supply cooling gas, and an AC high-voltage power supply. The plasma system offers the advantages of low power consumption and a large discharge area for ozone production. The wire-mesh electrode DBD comprises 64 discharge nodes, and the large amount of ozone generated from these nodes is used to oxidize odorous gases. Under optimized conditions, ozone is stably generated at the rate of 5.1 g/h for a specific input energy of 3.7 J/L. The ozone and odorous compounds (H2S: 4.5 ppm, CH3SH: 6.7 ppm, NH3: 3 ppm, outlet concentration) are injected into the main blower (20 N m3/min, compressed air). Finally, the experiments designed to simulate the removal of odorous gases confirmed that 99% of odorous compounds were removed using the wire-mesh electrode DBD. The cost-effectiveness and scalability of this system make it highly suitable for use in industrial environments where odorous gases are produced.
- 1 March 2020
- Published by Elsevier in Chemosphere
- Vol. 243, 125377
Plasma-assisted advanced oxidation process by a multi-hole dielectric barrier discharge in water and its application to wastewater treatment
- 1 March 2020
- Published by Elsevier in Chemosphere
- Vol. 243, 125377
Plasma-assisted advanced oxidation process by a multi-hole dielectric barrier discharge in water and its application to wastewater treatment
- Open Access
Correction: Chun S., et al. CO2 Microwave Plasma—Catalytic Reactor for Efficient Reforming of Methane to Syngas. Catalysts 2019, 9, 292
The authors found that the gas sensor analyzer had a large amount of error, and the re-experiments were tested several times
Open AccessCorrection: Chun S., et al. CO2 Microwave Plasma—Catalytic Reactor for Efficient Reforming of Methane to Syngas. Catalysts 2019, 9, 292
The authors found that the gas sensor analyzer had a large amount of error, and the re-experiments were tested several times
- Open Access
CO2 Microwave Plasma—Catalytic Reactor for Efficient Reforming of Methane to Syngas
CO2 was converted to synthesis gas in a microwave plasma–catalytic reactor by methane reforming at atmospheric pressure. The hybrid system used waste heat from the plasma to heat the catalyst. Conversion degrees were examined as a function of gas temperature, and the reforming efficiency of the plasma-only system was compared with that of the hybrid system. As a result, the hybrid system was shown to be more efficient under catalyst-free conditions. The use of microwave plasma alone resulted in low conversions of CO2 and CH4, which were 32.9% and 42.7%, respectively, at 3 kW microwave power. High CO2 and CH4 conversions of 87.9% and 92.9%, respectively, were achieved in the presence of catalyst at the same microwave power. At constant microwave power, catalyst addition increased the H2 and CO mass yield rates to 0.27 kg/h and 2.012 kg/h, respectively. Additionally, the H2 energy yield were 270 g/h, and 91.2 g/kWh. Thus, the developed hybrid system is well suited for efficient and economically viable CO2 reduction and synthesis gas production, paving the way for next-generation CO2 utilization and zero-emission industrial processes.
Open AccessCO2 Microwave Plasma—Catalytic Reactor for Efficient Reforming of Methane to Syngas
CO2 was converted to synthesis gas in a microwave plasma–catalytic reactor by methane reforming at atmospheric pressure. The hybrid system used waste heat from the plasma to heat the catalyst. Conversion degrees were examined as a function of gas temperature, and the reforming efficiency of the plasma-only system was compared with that of the hybrid system. As a result, the hybrid system was shown to be more efficient under catalyst-free conditions. The use of microwave plasma alone resulted in low conversions of CO2 and CH4, which were 32.9% and 42.7%, respectively, at 3 kW microwave power. High CO2 and CH4 conversions of 87.9% and 92.9%, respectively, were achieved in the presence of catalyst at the same microwave power. At constant microwave power, catalyst addition increased the H2 and CO mass yield rates to 0.27 kg/h and 2.012 kg/h, respectively. Additionally, the H2 energy yield were 270 g/h, and 91.2 g/kWh. Thus, the developed hybrid system is well suited for efficient and economically viable CO2 reduction and synthesis gas production, paving the way for next-generation CO2 utilization and zero-emission industrial processes.