Eduardo Cavaco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Eduardo Cavaco has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Luis Canhoto Neves
Department of Civil Engineering, University of Nottingham, Nottingham, UK
9 shared publications - Joan Ramon Casas
Universitat Politecnica de Catalunya
6 shared publications - Eduardo Júlio
CERIS, Instituto Superior Técnico – University of Lisbon Lisbon Portugal
5 shared publications - Paulo Fernandes
CERIS, Escola Superior de Tecnologia e Gestão Instituto Politécnico de Leiria Leiria Portugal
5 shared publications Eduardo Júlio
CERIS, DEC, Instituto Superior Técnico, Universidade de Lisboa Lisbon Portugal
4 shared publicationsJosé Camara
2 shared publications
Latest Publications
- 20 May 2025
- Published by Wiley in Structural Concrete
- Vol. 26 (4) , 3822-3836
The effects of post‐tension in the behavior of thin funicular concrete shells
The design of thin funicular concrete shells is typically based on the reversed shape of a membrane deformed by dead loads. Under similar loading scenarios, these structures are highly efficient, being primarily submitted to membrane compressive stresses. However, for non‐uniform and/or asymmetrical loading conditions, bending occurs, generating tensile stresses that significantly decrease the efficiency of this type of shell. This paper presents a numerical investigation on the adoption of bonded post‐tensioned strands as a mitigation strategy for tensile stresses due to bending in funicular shells built in plain concrete, that is, without steel reinforcement. A centered tendon layout is proposed, based on the principal stresses' directions under the most demanding and unfavorable load conditions. Results indicate that prestress can enhance the load‐carrying capacity of funicular shells, although with limited effect due to the null eccentricity of the strands and presenting detailing constraints at the support regions. The simultaneous use of ultra‐high‐performance fibre‐reinforced concrete is recommended to provide higher safety margins, reduce the required amount of prestressing, and improve the shell's behaviour under both service and ultimate limit states.
- 20 May 2025
- Published by Wiley in Structural Concrete
- Vol. 26 (4) , 3822-3836
The effects of post‐tension in the behavior of thin funicular concrete shells
The design of thin funicular concrete shells is typically based on the reversed shape of a membrane deformed by dead loads. Under similar loading scenarios, these structures are highly efficient, being primarily submitted to membrane compressive stresses. However, for non‐uniform and/or asymmetrical loading conditions, bending occurs, generating tensile stresses that significantly decrease the efficiency of this type of shell. This paper presents a numerical investigation on the adoption of bonded post‐tensioned strands as a mitigation strategy for tensile stresses due to bending in funicular shells built in plain concrete, that is, without steel reinforcement. A centered tendon layout is proposed, based on the principal stresses' directions under the most demanding and unfavorable load conditions. Results indicate that prestress can enhance the load‐carrying capacity of funicular shells, although with limited effect due to the null eccentricity of the strands and presenting detailing constraints at the support regions. The simultaneous use of ultra‐high‐performance fibre‐reinforced concrete is recommended to provide higher safety margins, reduce the required amount of prestressing, and improve the shell's behaviour under both service and ultimate limit states.
- 23 January 2025
- Published by Wiley in Structural Concrete
- Vol. 26 (4) , 3905-3915
Production and assembly of ultra‐thin concrete shells using prefabrication
This paper outlines the structural solutions and methodology developed for (1) the industrial production of an ultra‐thin double‐curvature shell prototype, prefabricated in ultra‐high performance fiber‐reinforced concrete (UHPFRC) modules, and (2) the on‐site assembly of the shell structure, involving prestressing and dry connections, and fixing to the foundations. To address the different challenges, including the double‐curvature shape, ultra‐thin thickness leading to high slenderness, the use of UHPFRC, small tolerances, precise dry indented connections, and the positioning of prestressing strands, a steel formwork, and vertical concreting were chosen. A support apparatus was developed to ensure structural integrity, working both as anchor plates of the prestressing strands and as connecting devices between the superstructure and the foundation. The methodology was developed using a realistic 3D digital model and validated (molds, production, assembly, and supports) in producing a reduced‐scale shell model, used to characterize the shell structural response under seismic loads on the National Laboratory of Civil Engineering's seismic table. The scale‐up of the process was made with the construction of a 15‐m full‐scale prototype of the shell structure.
- 23 January 2025
- Published by Wiley in Structural Concrete
- Vol. 26 (4) , 3905-3915
Production and assembly of ultra‐thin concrete shells using prefabrication
This paper outlines the structural solutions and methodology developed for (1) the industrial production of an ultra‐thin double‐curvature shell prototype, prefabricated in ultra‐high performance fiber‐reinforced concrete (UHPFRC) modules, and (2) the on‐site assembly of the shell structure, involving prestressing and dry connections, and fixing to the foundations. To address the different challenges, including the double‐curvature shape, ultra‐thin thickness leading to high slenderness, the use of UHPFRC, small tolerances, precise dry indented connections, and the positioning of prestressing strands, a steel formwork, and vertical concreting were chosen. A support apparatus was developed to ensure structural integrity, working both as anchor plates of the prestressing strands and as connecting devices between the superstructure and the foundation. The methodology was developed using a realistic 3D digital model and validated (molds, production, assembly, and supports) in producing a reduced‐scale shell model, used to characterize the shell structural response under seismic loads on the National Laboratory of Civil Engineering's seismic table. The scale‐up of the process was made with the construction of a 15‐m full‐scale prototype of the shell structure.
- 30 September 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (4) , 3809-3821
Numerical investigation on the behavior of thin concrete shells subjected to nonuniform and asymmetrical loads
Concrete shells, designed with near optimal shapes for uniform gravity loads, can be subjected to nonmembrane effects caused by nonuniform and asymmetrical loads. In this paper, a numerical study on the effect of normative loads on a thin triangular concrete shell with three supports is presented. Two actions were considered, wind and snow, which present high spatial variability in both intensity and direction, assuming the values established in Eurocode 1 for the worst possible location, in Portugal. Linear, nonlinear and stability analyses were performed using the ABAQUS software. Results suggest that the wind action, but especially the exceptional snow load in drifted arrangement, produce significant bending moments, leading to decompression, and eventually to the development of stresses above the tensile strength of current concrete classes. Therefore, the production of these shells by assembling prefabricated un‐reinforced modules, requires the use of ultrahigh‐performance fiber reinforced concrete, combined with prestressing.
- 30 September 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (4) , 3809-3821
Numerical investigation on the behavior of thin concrete shells subjected to nonuniform and asymmetrical loads
Concrete shells, designed with near optimal shapes for uniform gravity loads, can be subjected to nonmembrane effects caused by nonuniform and asymmetrical loads. In this paper, a numerical study on the effect of normative loads on a thin triangular concrete shell with three supports is presented. Two actions were considered, wind and snow, which present high spatial variability in both intensity and direction, assuming the values established in Eurocode 1 for the worst possible location, in Portugal. Linear, nonlinear and stability analyses were performed using the ABAQUS software. Results suggest that the wind action, but especially the exceptional snow load in drifted arrangement, produce significant bending moments, leading to decompression, and eventually to the development of stresses above the tensile strength of current concrete classes. Therefore, the production of these shells by assembling prefabricated un‐reinforced modules, requires the use of ultrahigh‐performance fiber reinforced concrete, combined with prestressing.
- 29 January 2024
- Published by Wiley in Structural Concrete
- Vol. 25 (3) , 1571-1589
Long‐term behavior of slender long‐span precast prestressed high‐strength concrete girders
The long‐term behavior of slender (1/40) long‐span precast high‐strength concrete girders was experimentally investigated regarding their use as a competitive solution in relation to steel alternatives for highway overpasses. The time‐dependent effects of full‐scale girders has rarely been addressed, particularly the influence of creep and shrinkage of concrete with compressive strengths around 120 MPa. Two half‐scale girder specimens were produced using an economically optimized and high‐strength concrete mixture, nonfiber reinforced, designed only with conventional raw materials, currently available at Portuguese precast companies, and subjected to long‐term loading, with a magnitude of approximately 50% of the failure load in bending, during a period of 3.75 years. Using the same mixture, prismatic specimens were also produced and subjected to long‐term loading at 24 h and 7 days of age to assess both creep and shrinkage. Results show that the age of concrete at the loading day is of paramount importance regarding the time‐dependent effects. These are most relevant during the first days of loading and tend to stabilize from the 112th day of loading onward. The time‐dependent girder's mid‐span deflection at the end of the 3.75 years did not exceed more than 50% of the initial deformation. Comparison of results with those obtained with Model Code 2010 and the current version of Eurocode 2 shows that these underestimate strains and deflections due to creep, mostly because the short‐term development of these effects, occurring during the first days of loading, are not adequately represented. On the contrary, a sound agreement between experimental and theoretical values, both in short and long term, was obtained using the Auperin et al. approach.
- 29 January 2024
- Published by Wiley in Structural Concrete
- Vol. 25 (3) , 1571-1589
Long‐term behavior of slender long‐span precast prestressed high‐strength concrete girders
The long‐term behavior of slender (1/40) long‐span precast high‐strength concrete girders was experimentally investigated regarding their use as a competitive solution in relation to steel alternatives for highway overpasses. The time‐dependent effects of full‐scale girders has rarely been addressed, particularly the influence of creep and shrinkage of concrete with compressive strengths around 120 MPa. Two half‐scale girder specimens were produced using an economically optimized and high‐strength concrete mixture, nonfiber reinforced, designed only with conventional raw materials, currently available at Portuguese precast companies, and subjected to long‐term loading, with a magnitude of approximately 50% of the failure load in bending, during a period of 3.75 years. Using the same mixture, prismatic specimens were also produced and subjected to long‐term loading at 24 h and 7 days of age to assess both creep and shrinkage. Results show that the age of concrete at the loading day is of paramount importance regarding the time‐dependent effects. These are most relevant during the first days of loading and tend to stabilize from the 112th day of loading onward. The time‐dependent girder's mid‐span deflection at the end of the 3.75 years did not exceed more than 50% of the initial deformation. Comparison of results with those obtained with Model Code 2010 and the current version of Eurocode 2 shows that these underestimate strains and deflections due to creep, mostly because the short‐term development of these effects, occurring during the first days of loading, are not adequately represented. On the contrary, a sound agreement between experimental and theoretical values, both in short and long term, was obtained using the Auperin et al. approach.
- Open Access
- 21 November 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 410
A novel roughness parameter for more precise estimation of the shear strength of concrete-to-concrete interfaces
- 21 November 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 410
Open AccessA novel roughness parameter for more precise estimation of the shear strength of concrete-to-concrete interfaces
- 30 June 2021
- Published by Wiley in Structural Concrete
- Vol. 22 (4) , 2272-2288
Flexural behavior of slender long‐span precast prestressed high‐strength concrete girders
- 30 June 2021
- Published by Wiley in Structural Concrete
- Vol. 22 (4) , 2272-2288
Flexural behavior of slender long‐span precast prestressed high‐strength concrete girders
- 2 March 2020
- Published by Wiley in Structural Concrete
- Vol. 21 (5) , 1989-1998
Admixture tuning for high‐performance concrete for the production of novel precast pre‐stressed long‐span girders for highway overpasses
The improvements observed in concrete technology in the last decades, namely the production of Portland cement CEM I 52.5 R, the development of third generation super‐plasticizers, and the commercialization of additions with high pozzolanic properties, turned possible the development of new concrete products using high performance concrete (HPC). Nevertheless, their implementation in the production process of the conservative precast concrete industry is not yet a reality. In this paper, the development and characterization of a HPC exhibiting high workability in the fresh state and high compressive strength in hardened state is presented. This HPC aims at producing, on a competitive basis, precast pre‐stressed long‐span girders for highway overpasses. For this reason, the main goal was to maximize the abovementioned properties but using the constituents available at the concrete precast company supporting the research. A set of different commercial admixtures was gathered and their influence on both compressive strength and workability of concrete was experimentally investigated. Results show that the compatibility between the admixture and the cementitious material is of paramount importance. By selecting the best type of the considered super‐plasticizers and by optimizing its dosage, it was possible to increase the workability from class S1 to S5 and, simultaneously, increase the compressive strength in circa 50%, up to 120 MPa, at 28 days of age.
- 2 March 2020
- Published by Wiley in Structural Concrete
- Vol. 21 (5) , 1989-1998
Admixture tuning for high‐performance concrete for the production of novel precast pre‐stressed long‐span girders for highway overpasses
The improvements observed in concrete technology in the last decades, namely the production of Portland cement CEM I 52.5 R, the development of third generation super‐plasticizers, and the commercialization of additions with high pozzolanic properties, turned possible the development of new concrete products using high performance concrete (HPC). Nevertheless, their implementation in the production process of the conservative precast concrete industry is not yet a reality. In this paper, the development and characterization of a HPC exhibiting high workability in the fresh state and high compressive strength in hardened state is presented. This HPC aims at producing, on a competitive basis, precast pre‐stressed long‐span girders for highway overpasses. For this reason, the main goal was to maximize the abovementioned properties but using the constituents available at the concrete precast company supporting the research. A set of different commercial admixtures was gathered and their influence on both compressive strength and workability of concrete was experimentally investigated. Results show that the compatibility between the admixture and the cementitious material is of paramount importance. By selecting the best type of the considered super‐plasticizers and by optimizing its dosage, it was possible to increase the workability from class S1 to S5 and, simultaneously, increase the compressive strength in circa 50%, up to 120 MPa, at 28 days of age.
- 25 February 2019
- Published by Wiley in Structural Concrete
- Vol. 20 (3) , 996-1009
A new method for corrosion assessment of reinforcing bars based on close‐range photogrammetry: Experimental validation
In most developed countries, a significant portion of the nation's Gross Domestic Product (GDP) is spent on maintenance of reinforced concrete (RC) structures suffering from corrosion. Although extensive research has been devoted to this issue, little attention has been given to the study of accurate methods to quantify corrosion and its spatial variability. As a result, scattered data can be found in the literature, relating the rates of corrosion, its penetration depth, and the resulting structural deteriorating effects. In this paper, a new cost‐effective and versatile method for corrosion assessment of RC structures based on close‐range photogrammetry is proposed. This method was validated by applying it to an experimental research on an accelerated corrosion test of reinforcing bars (RBs). The tests performed show that the proposed method can provide accurate results independent of the RB diameter, length, and corrosion level (measured in terms of rebar's cross section loss percentage), as long as sufficient image overlapping is ensured along the axial and radial axes of the rebar. The results obtained also prove that the method is suitable to measure spatial variability of corrosion attack, providing much better results than those gained from existing geometrical models based on the maximum pit depth. More precise results can be achieved by using semi‐professional Digital Single‐Lens Reflex Cameras (DSLR) cameras having the additional advantage to be suitable for low levels of corrosion attack. However, the research performed shows that accurate results can also be obtained even when a less sophisticated or a smartphone camera is used.
- 25 February 2019
- Published by Wiley in Structural Concrete
- Vol. 20 (3) , 996-1009
A new method for corrosion assessment of reinforcing bars based on close‐range photogrammetry: Experimental validation
In most developed countries, a significant portion of the nation's Gross Domestic Product (GDP) is spent on maintenance of reinforced concrete (RC) structures suffering from corrosion. Although extensive research has been devoted to this issue, little attention has been given to the study of accurate methods to quantify corrosion and its spatial variability. As a result, scattered data can be found in the literature, relating the rates of corrosion, its penetration depth, and the resulting structural deteriorating effects. In this paper, a new cost‐effective and versatile method for corrosion assessment of RC structures based on close‐range photogrammetry is proposed. This method was validated by applying it to an experimental research on an accelerated corrosion test of reinforcing bars (RBs). The tests performed show that the proposed method can provide accurate results independent of the RB diameter, length, and corrosion level (measured in terms of rebar's cross section loss percentage), as long as sufficient image overlapping is ensured along the axial and radial axes of the rebar. The results obtained also prove that the method is suitable to measure spatial variability of corrosion attack, providing much better results than those gained from existing geometrical models based on the maximum pit depth. More precise results can be achieved by using semi‐professional Digital Single‐Lens Reflex Cameras (DSLR) cameras having the additional advantage to be suitable for low levels of corrosion attack. However, the research performed shows that accurate results can also be obtained even when a less sophisticated or a smartphone camera is used.
- 1 February 2019
- Published by Elsevier in Engineering Structures
- Vol. 180, 274-283
Effect of non-structural masonry brick infill walls on the robustness of a RC framed building severely damaged due to a landslide
- 1 February 2019
- Published by Elsevier in Engineering Structures
- Vol. 180, 274-283
Effect of non-structural masonry brick infill walls on the robustness of a RC framed building severely damaged due to a landslide
- 24 November 2018
- Published by Taylor & Francis in European Journal of Environmental and Civil Engineering
- Vol. 24 (12) , 1921-1938
Mechanical performance of eco-efficient hollow clay bricks incorporating industrial nano-crystalline aluminium sludge
In this paper, mechanical properties of a new structural and eco-efficient hollow clay bricks are investigated. The principal goal was to recycle residual sludge from aluminium anodising industries by incorporating it in the raw material of bricks, thus contributing for the sustainability of the construction sector. It was also an objective to enhance thermal properties of the bricks, contributing to improve the energy efficiency of buildings, and maintain their mechanical properties. A large set of mechanical tests was conducted. A comparison between traditional, structural and the new eco-efficient bricks is established. Results show that the mechanical properties of the new bricks and masonry are not significantly affected by the aluminium sludge, thus allowing their use without strength limitations, and taking advantage from the thermal improved performance.
- 24 November 2018
- Published by Taylor & Francis in European Journal of Environmental and Civil Engineering
- Vol. 24 (12) , 1921-1938
Mechanical performance of eco-efficient hollow clay bricks incorporating industrial nano-crystalline aluminium sludge
In this paper, mechanical properties of a new structural and eco-efficient hollow clay bricks are investigated. The principal goal was to recycle residual sludge from aluminium anodising industries by incorporating it in the raw material of bricks, thus contributing for the sustainability of the construction sector. It was also an objective to enhance thermal properties of the bricks, contributing to improve the energy efficiency of buildings, and maintain their mechanical properties. A large set of mechanical tests was conducted. A comparison between traditional, structural and the new eco-efficient bricks is established. Results show that the mechanical properties of the new bricks and masonry are not significantly affected by the aluminium sludge, thus allowing their use without strength limitations, and taking advantage from the thermal improved performance.