Dmitry Tugay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dmitry Tugay has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- George G. Zhemerov
Национальный технический университет "Харьковский политехнический институт
4 shared publications George Zhemerov
Dept. of Industrial and Biomedical Electronics, National Technical University “KhPI”, Kharkiv, Ukraine
4 shared publications- Serhii Korneliuk
Dept. of Alternative Power Engineering and Electrical Engineering, O.M. Beketov NUUE, Kharkiv, Ukraine
4 shared publications - G.G. Zhemerov3 shared publications
- Oleksandr Shkurpela
O.M. Beketov National University of Urban Economy in Kharkiv
3 shared publications - Ivan Kostenko
O.M. Beketov National University of Urban Economy in Kharkiv
2 shared publications
Latest Publications
- Open Access
- 30 December 2021
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- Vol. 60 (3) , 79-91
A Decomposition Four-Component Model for Calculating Power Losses in Low-Voltage Power Supply Systems
A new model for decomposition of the total power losses, which includes four components is proposed. Each of the components of the proposed model has a certain physical meaning due to the nature of electromagnetic processes in a three-phase four-wire system. Definitions to describe each of the proposed components are formulated. It is shown that each of supplementary components of the total loss power is proportional to the minimum possible loss power and to the square of the RMS value of the power, which is caused by its occurrence in three-phase four-wire power supply system, and it is inversely proportional to the mean square of the net power loss. The synthesized Matlab-model for verification of the four-component structure of power losses showed a high degree of its adequacy. The proposed model allows us to rethink the description of power losses in three-phase AC circuits and can be used in specialized measuring instruments for electrical networks monitoring. Using the information obtained in the monitoring process, it is possible to plan technical measures to reduce losses of electrical energy in the power supply system, as well as to estimate the capital costs of these measures.
- 30 December 2021
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- Vol. 60 (3) , 79-91
Open AccessA Decomposition Four-Component Model for Calculating Power Losses in Low-Voltage Power Supply Systems
A new model for decomposition of the total power losses, which includes four components is proposed. Each of the components of the proposed model has a certain physical meaning due to the nature of electromagnetic processes in a three-phase four-wire system. Definitions to describe each of the proposed components are formulated. It is shown that each of supplementary components of the total loss power is proportional to the minimum possible loss power and to the square of the RMS value of the power, which is caused by its occurrence in three-phase four-wire power supply system, and it is inversely proportional to the mean square of the net power loss. The synthesized Matlab-model for verification of the four-component structure of power losses showed a high degree of its adequacy. The proposed model allows us to rethink the description of power losses in three-phase AC circuits and can be used in specialized measuring instruments for electrical networks monitoring. Using the information obtained in the monitoring process, it is possible to plan technical measures to reduce losses of electrical energy in the power supply system, as well as to estimate the capital costs of these measures.
- Open Access
- 30 December 2021
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- Vol. 60 (3) , 103-111
Reducing Power Losses by Voltage Stabilization at the DC Rolling Stock Current Collector
The invention relates to an energy-efficient method for voltage stabilization at the electric rolling stock current collector through traction substation control means which provide a nominal voltage value during the electric train movement by an interstation section. The dependence of potential distribution in the contact wire during the electric rolling stock movement by an interstation section was investigated. Also researched and developed are the new ways of voltage stabilization at the current collector of the electric rolling stock based on synchronous (the same for two adjacent traction substations) and asynchronous paths of voltage regulation at DC buses of traction substations related to one synchronous and two asynchronous ways of voltage stabilization in the contact network with obtaining the energy performance describing them. The energy performance of the investigated methods of voltage stabilization in the contact network is compared, and the energy efficiency of each of them is determined. It is proved that the use of modern types of semiconductor converters such as an active rectifier – voltage source in the power equipment of DC traction substations will enable to implement adaptive voltage stabilization systems at the rolling stock current collector, providing nominal voltage values of traction motors on the interstation section without using additional equipment on the rolling stock and, as a consequence, justification and application of these methods is suitable for upgrading the existing and designing new traction substations.
- 30 December 2021
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Lighting Engineering & Power Engineering
- Vol. 60 (3) , 103-111
Open AccessReducing Power Losses by Voltage Stabilization at the DC Rolling Stock Current Collector
The invention relates to an energy-efficient method for voltage stabilization at the electric rolling stock current collector through traction substation control means which provide a nominal voltage value during the electric train movement by an interstation section. The dependence of potential distribution in the contact wire during the electric rolling stock movement by an interstation section was investigated. Also researched and developed are the new ways of voltage stabilization at the current collector of the electric rolling stock based on synchronous (the same for two adjacent traction substations) and asynchronous paths of voltage regulation at DC buses of traction substations related to one synchronous and two asynchronous ways of voltage stabilization in the contact network with obtaining the energy performance describing them. The energy performance of the investigated methods of voltage stabilization in the contact network is compared, and the energy efficiency of each of them is determined. It is proved that the use of modern types of semiconductor converters such as an active rectifier – voltage source in the power equipment of DC traction substations will enable to implement adaptive voltage stabilization systems at the rolling stock current collector, providing nominal voltage values of traction motors on the interstation section without using additional equipment on the rolling stock and, as a consequence, justification and application of these methods is suitable for upgrading the existing and designing new traction substations.
- 1 January 2021
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 1,p. 103-110
Method for optimization of switching frequency in frequency converters
Purpose. To present a methodology for determining the optimal switching frequency in frequency converters and autonomous voltage inverters, the load of which is an asynchronous electric motor. The methodology is based on determining the dependences of static and dynamic power losses in the power switches of the inverter on the switching frequency and the dependence of power losses in the windings of an induction motor on the higher harmonics of currents, which also depend on the switching frequency. Methodology. Polynomial approximation of the energy characteristics of power transistors. General provisions of the theory of electrical circuits. The determination of additional power losses in the windings of an induction motor from higher harmonics is based on analytical calculation and simulation in the Matlab/Simulink software environment and a specialized program from the manufacturer of power switches Mitsubishi MelcoSim5.1. Findings. A method for optimizing the frequency of pulse-width modulation in frequency converters, the load of which is an asynchronous motor, is presented according to the criterion of the minimum total power losses in the power transistors of the inverter and the resistance of the motor windings. The proposed calculation technique allows determining the dependence of static and dynamic losses in power IGBT-transistors with a sufficiently high accuracy while being in the MelcoSim software environment. To calculate the losses in the motor, it is shown that the switching frequency of the power switches affects the harmonic distortion factor and the average value of the phase current of the induction motor. Provided that only the first harmonic of the current performs the useful action in an asynchronous motor, the dependence of additional power losses on the switching frequency is given. Originality. A method for optimizing the frequency of pulse-width modulation by the criterion of minimum additional power losses in the resistance of the motor windings from higher harmonics of the current and static and dynamic losses in the power transistors of the inverter is presented. An analytical dependence of additional power losses in the active resistance of the windings of induction motors as a function of the harmonic distortion factor of the phase current of an autonomous voltage inverter is presented. Practical value. The presented technique makes it possible to determine the optimal modulation frequency in frequency converters with asynchronous motors and to ensure the minimum total power losses and the maximum value of efficiency in the autonomous voltage inverter asynchronous motor system.
- 1 January 2021
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 1,p. 103-110
Method for optimization of switching frequency in frequency converters
Purpose. To present a methodology for determining the optimal switching frequency in frequency converters and autonomous voltage inverters, the load of which is an asynchronous electric motor. The methodology is based on determining the dependences of static and dynamic power losses in the power switches of the inverter on the switching frequency and the dependence of power losses in the windings of an induction motor on the higher harmonics of currents, which also depend on the switching frequency. Methodology. Polynomial approximation of the energy characteristics of power transistors. General provisions of the theory of electrical circuits. The determination of additional power losses in the windings of an induction motor from higher harmonics is based on analytical calculation and simulation in the Matlab/Simulink software environment and a specialized program from the manufacturer of power switches Mitsubishi MelcoSim5.1. Findings. A method for optimizing the frequency of pulse-width modulation in frequency converters, the load of which is an asynchronous motor, is presented according to the criterion of the minimum total power losses in the power transistors of the inverter and the resistance of the motor windings. The proposed calculation technique allows determining the dependence of static and dynamic losses in power IGBT-transistors with a sufficiently high accuracy while being in the MelcoSim software environment. To calculate the losses in the motor, it is shown that the switching frequency of the power switches affects the harmonic distortion factor and the average value of the phase current of the induction motor. Provided that only the first harmonic of the current performs the useful action in an asynchronous motor, the dependence of additional power losses on the switching frequency is given. Originality. A method for optimizing the frequency of pulse-width modulation by the criterion of minimum additional power losses in the resistance of the motor windings from higher harmonics of the current and static and dynamic losses in the power transistors of the inverter is presented. An analytical dependence of additional power losses in the active resistance of the windings of induction motors as a function of the harmonic distortion factor of the phase current of an autonomous voltage inverter is presented. Practical value. The presented technique makes it possible to determine the optimal modulation frequency in frequency converters with asynchronous motors and to ensure the minimum total power losses and the maximum value of efficiency in the autonomous voltage inverter asynchronous motor system.
- Open Access
- 5 May 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2020 (3) , 36-39
EQUIVALENCE OF VECTOR AND PROPORTIONAL CONTROLLING METHODS FOR ACTIVE POWER FILTER
Joomla! - the dynamic portal engine and content management system
- 5 May 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2020 (3) , 36-39
Open AccessEQUIVALENCE OF VECTOR AND PROPORTIONAL CONTROLLING METHODS FOR ACTIVE POWER FILTER
Joomla! - the dynamic portal engine and content management system
- 1 January 2020
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 5,p. 73-79
Simulation of industrial solar photovoltaic station with transformerless converter system
Purpose. Creation of a detailed model of a solar photovoltaic station with a converter system based on a cascaded multi-level inverter with the MPPT (maximum power point tracker) function to investigate its operating modes in distributed power systems. Methodology. To carry out the research, the paper used the methods of system synthesis, mathematical and computer modeling to create photovoltaic station models and components; a physical experiment in obtaining thermal characteristics of the photovoltaic module Solarday SDM72360 W; modern power theories for synthesis of the vector control system of a multi-level inverter. Findings. the Matlab-model of solar photovoltaic station with transformerless 29-level cascade voltage inverter is synthesized. The model confirmed the serviceability and efficiency of the converter system and the power plant as a whole. An algorithm is proposed and an MPP tracker with volt-ampere characteristics of the photovoltaic module, which corresponds to the maximum power extraction, is synthesized on the basis of the algorithm. The algorithm was validated by the model for any solar radiation intensity. Originality. The total mathematical model of the photoelectric module, which accounts for its energy and heat characteristics, is obtained and can be used for simulating the operation of any computer model of the photoelectric converter under Matlab/Simulink/SimPowerSystems environment. Practical value. The model results indicate the prospects of industrial implementation of transformerless multi-level converter systems to be used in the structure of powerful solar photovoltaic stations.
- 1 January 2020
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 5,p. 73-79
Simulation of industrial solar photovoltaic station with transformerless converter system
Purpose. Creation of a detailed model of a solar photovoltaic station with a converter system based on a cascaded multi-level inverter with the MPPT (maximum power point tracker) function to investigate its operating modes in distributed power systems. Methodology. To carry out the research, the paper used the methods of system synthesis, mathematical and computer modeling to create photovoltaic station models and components; a physical experiment in obtaining thermal characteristics of the photovoltaic module Solarday SDM72360 W; modern power theories for synthesis of the vector control system of a multi-level inverter. Findings. the Matlab-model of solar photovoltaic station with transformerless 29-level cascade voltage inverter is synthesized. The model confirmed the serviceability and efficiency of the converter system and the power plant as a whole. An algorithm is proposed and an MPP tracker with volt-ampere characteristics of the photovoltaic module, which corresponds to the maximum power extraction, is synthesized on the basis of the algorithm. The algorithm was validated by the model for any solar radiation intensity. Originality. The total mathematical model of the photoelectric module, which accounts for its energy and heat characteristics, is obtained and can be used for simulating the operation of any computer model of the photoelectric converter under Matlab/Simulink/SimPowerSystems environment. Practical value. The model results indicate the prospects of industrial implementation of transformerless multi-level converter systems to be used in the structure of powerful solar photovoltaic stations.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 289-294
Three Theoremes of the Instantaneous Power Theory
Three theorems of the instantaneous power theory, which make it possible to explain the nature of electromagnetic processes occurring in three-phase power supply systems in terms of assessing the energy efficiency of systems in question, are formulated and proved.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 289-294
Three Theoremes of the Instantaneous Power Theory
Three theorems of the instantaneous power theory, which make it possible to explain the nature of electromagnetic processes occurring in three-phase power supply systems in terms of assessing the energy efficiency of systems in question, are formulated and proved.
- 25 October 2018
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2018 (6) , 73-76
EFFICIENCY OF REGENERATIVE BRAKING IN ENERGY SUPPLY SYSTEMS WITH ELECTRIC REGULATED DRIVES
Joomla! - the dynamic portal engine and content management system
- 25 October 2018
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2018 (6) , 73-76
EFFICIENCY OF REGENERATIVE BRAKING IN ENERGY SUPPLY SYSTEMS WITH ELECTRIC REGULATED DRIVES
Joomla! - the dynamic portal engine and content management system
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 275-279
Energy Efficiency of Microgrid Implementation with Solar Photovoltaic Power Plants
The work with the use of simulation in the software Matlab / Simulink / SymPowerSystems environment considers construction of a local Smart Grid energy supply system with distributed solar power plants. The obtained model allows us to investigate the work of the intelligent network in any quasi-steady and transitional modes, including emergency ones. A distinctive feature of the proposed model is the localization of places for the installation of power active filter-compensating devices, the use of which allows providing the necessary quality of electric energy and achieving the minimum energy losses in the elements of the energy supply system. According to the results of the simulation, the comparison of the energy efficiency of the traditional energy supply system and Smart Grid has been made.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 275-279
Energy Efficiency of Microgrid Implementation with Solar Photovoltaic Power Plants
The work with the use of simulation in the software Matlab / Simulink / SymPowerSystems environment considers construction of a local Smart Grid energy supply system with distributed solar power plants. The obtained model allows us to investigate the work of the intelligent network in any quasi-steady and transitional modes, including emergency ones. A distinctive feature of the proposed model is the localization of places for the installation of power active filter-compensating devices, the use of which allows providing the necessary quality of electric energy and achieving the minimum energy losses in the elements of the energy supply system. According to the results of the simulation, the comparison of the energy efficiency of the traditional energy supply system and Smart Grid has been made.
- 9 August 2018
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2018 (5) , 88-91
THE OVERHEAD LINE VOLTAGE STABILIZATION TO INCREASE THE EFFICIENCY OF THE DC ELECTRIC RAIL TRACTION SYSTEM
Joomla! - the dynamic portal engine and content management system
- 9 August 2018
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2018 (5) , 88-91
THE OVERHEAD LINE VOLTAGE STABILIZATION TO INCREASE THE EFFICIENCY OF THE DC ELECTRIC RAIL TRACTION SYSTEM
Joomla! - the dynamic portal engine and content management system
- Open Access
- 19 December 2016
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 6,p. 31-38
THE PHASE REACTOR INDUCTANCE SELECTION TECHNIQUE FOR POWER ACTIVE FILTER
Анотація Мета. Метою статті є розробка методики вибору індуктивності фазних реакторів паралельного силового активного фільтру, що заснована на обліку як низькочастотної так і високочастотної складових електромагнітних процесів в силовій схемі. Методика. Для проведення досліджень використовувалися положення теорії електричних кіл, векторний аналіз, математичне моделювання в пакеті Matlab. Результати. Розроблено нову методику вибору індуктивності фазних реакторів паралельного силового активного фільтра, що дозволяє отримати мінімально можливе значення коефіцієнта нелінійних спотворень мережного струму. Наукова новизна. Підвищено точність методів вибору індуктивності фазних реакторів силового активного фільтра. Практичне значення. Запропонована методика може використовуватися при проектуванні і виготовленні силових активних фільтрів для реальних об'єктів електропостачання.
- 19 December 2016
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 6,p. 31-38
Open AccessTHE PHASE REACTOR INDUCTANCE SELECTION TECHNIQUE FOR POWER ACTIVE FILTER
Анотація Мета. Метою статті є розробка методики вибору індуктивності фазних реакторів паралельного силового активного фільтру, що заснована на обліку як низькочастотної так і високочастотної складових електромагнітних процесів в силовій схемі. Методика. Для проведення досліджень використовувалися положення теорії електричних кіл, векторний аналіз, математичне моделювання в пакеті Matlab. Результати. Розроблено нову методику вибору індуктивності фазних реакторів паралельного силового активного фільтра, що дозволяє отримати мінімально можливе значення коефіцієнта нелінійних спотворень мережного струму. Наукова новизна. Підвищено точність методів вибору індуктивності фазних реакторів силового активного фільтра. Практичне значення. Запропонована методика може використовуватися при проектуванні і виготовленні силових активних фільтрів для реальних об'єктів електропостачання.