OSOleksandr Shkurpela

Oleksandr Shkurpela

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oleksandr Shkurpela has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determining the power distribution of photovoltaic modules in multitracker photovoltaic systems

    by Ibrahim Farhan Alrefo, Oleksandr Shkurpela, Dmytro Kovalenko, Yana Forkun, Oleksiy Iegorov, Olga Iegorova, Oeksandr Miroshnyk, Oleg Synyuk, Valeriy Martynyuk

    The process that generates the output power of a photovoltaic system depending on the orientation of parallel strings has been considered in this work. The task addressed relates to the lack of simulation models for investigating multitracker photovoltaic stations that could make it possible to study their operation and compile recommendations to modernize photovoltaic stations and convert them into multitrackers for more efficient utilization of available area that is not facing south. This paper analyzes the influence of photovoltaic module characteristics when changing the level of illumination on the overall efficiency of the photovoltaic array in a solar multitracker station. The study was performed using the MATLAB software package (USA), which made it possible to quantitatively assess the level of mutual influence of the parameters of photovoltaic modules on the photovoltaic array power. By means of simulation modeling, it was established that multitracker photovoltaic systems have an advantage over monotracker ones during the morning and evening operation; specifically, the advantage is up to 32%. It is also shown that during the daytime, the multitracker system is on average 12–15% inferior to the monotracker system in terms of power. The results are attributed to the more efficient use of photovoltaic modules in the system, which are distributed at optimal angles. A feature of the photovoltaic system modeling in this study is the exclusion of the DC converter, so the findings give a more accurate idea about the position of the system’s operating point. The results make it possible to compile recommendations for multitracker photovoltaic stations for more efficient utilization of the available area that is not facing south and the use of the full power of station’s MPPT (Maximum Power Point Tracking) controllers

  • Open Access

    Development of the active part of an asynchronous generator for a low-power wind turbine

    by Oleksiy Iegorov, Oleksandr Shkurpela, Dmytro Kovalenko

    The article presents an analysis of the operating characteristics of developed asynchronous generators with a squirrel-cage rotor for low-power wind turbines. For comparison, three samples of 10-, 12-, and 14-pole asynchronous generators are proposed. The development was carried out in the Ansys Maxwell software package, and the operating characteristics were constructed in MATLAB. The use of an asynchronous generator in a low-power wind turbine is dictated by the lower cost of the asynchronous generator and the absence of imported rare materials, such as neodymium magnets. For comparison, operating characteristics were constructed for nominal and reduced frequencies, since the main operating range of the wind turbine is frequencies below the nominal frequency. Particular attention was paid to the characteristics of efficiency and power factor, since the control system of the asynchronous generator will have to be optimized to maximize these parameters in order to achieve maximum energy efficiency of the wind turbine. All developed generators demonstrated their ability to operate and have fairly similar operating characteristics. However, a detailed analysis allowed us to determine the optimal design of an asynchronous generator for use in a low-power wind turbine.

  • Open Access

    ОГЛЯД АЛГОРИТМІВ ВІДСТЕЖЕННЯ ТОЧКИ МАКСИМАЛЬНОЇ ПОТУЖНОСТІ ДЛЯ ВІТРОУСТАНОВОК МАЛОЇ ПОТУЖНОСТІ

    by Олександр Шкурпела, Дмитро Коваленко

    У роботі проведено огляд основних алгоритмів відстеження точки максимальної потужності (MPPT), придатних для використання у вітроустановках малої потужності з асинхронним генератором із короткозамкненим ротором та дволанковим перетворювачем. Дослідження показало, що більшість робіт зосереджено на огляді алгоритмів MPPT для вітроустановок із синхронними генераторами з постійними магнітами, частково із асинхронними генераторами з фазним ротором та розгляді окремих алгоритмів для вітроустановок з асинхронними генераторами із короткозамкненим ротором. Дана робота приділяє увагу систематизації алгоритмів MPPT, оцінці їх переваг і недоліків для вітроустановок малої потужності з вказаним вище типом силового електрообладнання. Пропонується класифікація алгоритмів MPPT за двома основними групами: традиційні та інтелектуальні/гібридні (використання нечіткої логіки та штучних нейронних мереж), що у більшості збігається з класифікацією алгоритмів для вітроустановок з синхронними генераторами з постійними магнітами. Для вітроустановок малої потужності з асинхронним генератором із короткозамкненим ротором та дволанковим перетворювачем найбільший інтерес представляють традиційні алгоритми MPPT, оскільки вони не потребують значних обчислювальних ресурсів та можуть бути легко інтегровані до основної системи керування вітроустановки. Основні традиційні алгоритми розглянуто з урахуванням малої потужності вітроустановки та їх використання з асинхронним генератором із короткозамкненим ротором, що потребує збудження у процесі роботи. Результати роботи можуть бути використані при виборі оптимального алгоритму MPPT для подальшого дослідження систем керування вітроустановок малої потужності з асинхронним генератором із короткозамкненим ротором та дволанковим перетворювачем.

  • Open Access

    Modeling the Operation of a Wind Power Plant with Full Energy Conversion

    by Oleksandr Shkurpela, Dmytro Kovalenko, Andrii Kutinov

    The article provides an analysis of the operation of a wind power plant with full energy conversion based on an asynchronous generator with a short-circuited rotor. The possibility of optimizing the operation of the asynchronous generator at low speeds of shaft rotation allows to expand the range of effective use of the wind power plant at unstable wind speed and opens up wide opportunities for the application of intelligent control systems for the asynchronous generator, in contrast to the generator based on a synchronous machine with permanent magnets. These advantages are achieved due to the use of converting technology, which in turn requires the use of a complex control system, the sequence of turning on the converters and the separation of control and feedback loops. The use of an asynchronous generator with a short-circuited rotor requires the presence of an initial magnetization of the machine for further operation, this can be achieved in several ways either from the network or from the storage, in the case of an autonomous system with a wind energy installation. In the course of the work, it was shown that non-compliance with the start-up procedure of the wind energy installation may result in abnormal modes accompanied by significant current and dynamic mechanical overloads of the machine and the installation's converters. The resulting simulation model can be used for research and comparative analysis of the operating modes of wind turbines with different types of generators and optimization of their control system in order to maximize the generated power from wind energy in various conditions.

  • Open Access

    Modeling the Operation of a Wind Power Plant with Full Energy Conversion

    by Oleksandr Shkurpela, Dmytro Kovalenko, Andrii Kutinov

    The paper provides an analysis of the operation of a wind power plant with full energy conversion based on an asynchronous generator with a short-circuited rotor. The possibility of optimizing the operation of the asynchronous generator at low speeds of shaft rotation allows to expand the range of effective use of the wind power plant at unstable wind speed and opens up wide opportunities for the application of intelligent control systems for the asynchronous generator, in contrast to the generator based on a synchronous ma-chine with permanent magnets. These advantages are achieved due to the use of converting technology, which in turn requires the use of a complex control system, the sequence of turning on the converters and the separation of control and feedback loops. The use of an asynchronous generator with a short-circuited rotor requires the presence of an initial magnetization of the machine for further operation, this can be achieved in several ways either from the network or from the storage, in the case of an autonomous system with a wind energy installation. In the course of the work, it was shown that non-compliance with the start-up procedure of the wind energy installation may result in abnormal modes accompanied by significant current and dynamic mechanical overloads of the machine and the installation's converters. The resulting simulation model can be used for research and comparative analysis of the operating modes of wind turbines with different types of generators and optimization of their control system in order to maximize the generated power from wind energy in various conditions.


  • Open Access

    A Decomposition Four-Component Model for Calculating Power Losses in Low-Voltage Power Supply Systems

    by Dmitry Tugay, Olexandr Shkurpela, Valentyn Akymov, Ivan Kostenko, Oleksandr Plakhtii

    A new model for decomposition of the total power losses, which includes four components is proposed. Each of the components of the proposed model has a certain physical meaning due to the nature of electromagnetic processes in a three-phase four-wire system. Definitions to describe each of the proposed components are formulated. It is shown that each of supplementary components of the total loss power is proportional to the minimum possible loss power and to the square of the RMS value of the power, which is caused by its occurrence in three-phase four-wire power supply system, and it is inversely proportional to the mean square of the net power loss. The synthesized Matlab-model for verification of the four-component structure of power losses showed a high degree of its adequacy. The proposed model allows us to rethink the description of power losses in three-phase AC circuits and can be used in specialized measuring instruments for electrical networks monitoring. Using the information obtained in the monitoring process, it is possible to plan technical measures to reduce losses of electrical energy in the power supply system, as well as to estimate the capital costs of these measures.


  • Open Access

    Reducing Power Losses by Voltage Stabilization at the DC Rolling Stock Current Collector

    by Dmitry Tugay, Alina Trotsai, Olexandr Shkurpela, Ivan Kostenko

    The invention relates to an energy-efficient method for voltage stabilization at the electric rolling stock current collector through traction substation control means which provide a nominal voltage value during the electric train movement by an interstation section. The dependence of potential distribution in the contact wire during the electric rolling stock movement by an interstation section was investigated. Also researched and developed are the new ways of voltage stabilization at the current collector of the electric rolling stock based on synchronous (the same for two adjacent traction substations) and asynchronous paths of voltage regulation at DC buses of traction substations related to one synchronous and two asynchronous ways of voltage stabilization in the contact network with obtaining the energy performance describing them. The energy performance of the investigated methods of voltage stabilization in the contact network is compared, and the energy efficiency of each of them is determined. It is proved that the use of modern types of semiconductor converters such as an active rectifier – voltage source in the power equipment of DC traction substations will enable to implement adaptive voltage stabilization systems at the rolling stock current collector, providing nominal voltage values of traction motors on the interstation section without using additional equipment on the rolling stock and, as a consequence, justification and application of these methods is suitable for upgrading the existing and designing new traction substations.

  • Simulation of industrial solar photovoltaic station with transformerless converter system

    by D. V Tugay, S. I Korneliuk, O. O Shkurpela, V. S Akimov

    Purpose. Creation of a detailed model of a solar photovoltaic station with a converter system based on a cascaded multi-level inverter with the MPPT (maximum power point tracker) function to investigate its operating modes in distributed power systems. Methodology. To carry out the research, the paper used the methods of system synthesis, mathematical and computer modeling to create photovoltaic station models and components; a physical experiment in obtaining thermal characteristics of the photovoltaic module Solarday SDM72360 W; modern power theories for synthesis of the vector control system of a multi-level inverter. Findings. the Matlab-model of solar photovoltaic station with transformerless 29-level cascade voltage inverter is synthesized. The model confirmed the serviceability and efficiency of the converter system and the power plant as a whole. An algorithm is proposed and an MPP tracker with volt-ampere characteristics of the photovoltaic module, which corresponds to the maximum power extraction, is synthesized on the basis of the algorithm. The algorithm was validated by the model for any solar radiation intensity. Originality. The total mathematical model of the photoelectric module, which accounts for its energy and heat characteristics, is obtained and can be used for simulating the operation of any computer model of the photoelectric converter under Matlab/Simulink/SimPowerSystems environment. Practical value. The model results indicate the prospects of industrial implementation of transformerless multi-level converter systems to be used in the structure of powerful solar photovoltaic stations.