Aleksander I. Shishpanov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aleksander I. Shishpanov has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Yury Z. Ionikh
St. Petersburg State University, St. Petersburg, Russia
5 shared publications - Aleksandr V Meshchanov
St.Petersburg State University, 7-9 Universitetskaya Emb., St.Petersburg 199034, Russia
4 shared publications D O Ivanov
3 shared publications- Pavel S. Bazhin
St. Petersburg State University
2 shared publications S A Kalinin
2 shared publications- Vladislav V. Zaletov
St. Petersburg State University, St. Petersburg, Russia
2 shared publications
Latest Publications
- 1 June 2026
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 52 (6) , 723-735
Patterns of Ionization Waves Attenuation in Inert Gases
Ionization waves in gases often appear at the initial stages of electrical breakdown in a non-uniform external electric field. These waves have highly reproducible parameters and are used in plasma technologies, making them a subject of research for many scientific groups. An important property of this wave is the relationship between propagation velocity and electrodynamic characteristics. Establishing an explicit form of this relationship would allow us to understand the dynamics of the transferred high potential or the generated electron density based just on relatively simple observations of the wave motion. In this research, we attempt to establish such a relationship for the specific case of ionization waves that occur during single-electrode breakdown of a long discharge tube under constant electrode voltage. The pattern of the velocity attenuation is found experimentally and proofed theoretically, its relationship with the attenuation of the potential and field amplitude at the front is demonstrated. The corresponding attenuation coefficients have been measured in helium, neon, argon, krypton, and xenon at a pressure of 1 Torr, as well as in neon in the pressure range of 0.5–50 Torr at 3 kV voltage of both polarities. We also have proposed semiempirical model that relates the electric field in plasma channel behind the front, the channel current, and electron concentration to the attenuation coefficients and discharge system parameters. These results allow us to analyze the ionization wave attenuation in experiments by other authors and can be useful in modeling this complex phenomenon.
- 1 June 2026
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 52 (6) , 723-735
Patterns of Ionization Waves Attenuation in Inert Gases
Ionization waves in gases often appear at the initial stages of electrical breakdown in a non-uniform external electric field. These waves have highly reproducible parameters and are used in plasma technologies, making them a subject of research for many scientific groups. An important property of this wave is the relationship between propagation velocity and electrodynamic characteristics. Establishing an explicit form of this relationship would allow us to understand the dynamics of the transferred high potential or the generated electron density based just on relatively simple observations of the wave motion. In this research, we attempt to establish such a relationship for the specific case of ionization waves that occur during single-electrode breakdown of a long discharge tube under constant electrode voltage. The pattern of the velocity attenuation is found experimentally and proofed theoretically, its relationship with the attenuation of the potential and field amplitude at the front is demonstrated. The corresponding attenuation coefficients have been measured in helium, neon, argon, krypton, and xenon at a pressure of 1 Torr, as well as in neon in the pressure range of 0.5–50 Torr at 3 kV voltage of both polarities. We also have proposed semiempirical model that relates the electric field in plasma channel behind the front, the channel current, and electron concentration to the attenuation coefficients and discharge system parameters. These results allow us to analyze the ionization wave attenuation in experiments by other authors and can be useful in modeling this complex phenomenon.
- 1 July 2024
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 51 (7) , 256-261
Ionization Waves Initiating Single-Electrode Breakdown in Long Discharge Tubes
Ionization waves (IWs) of positive polarity are studied experimentally in several sealed discharge tubes containing neon at pressures of 0.6‒15 Torr
- 1 July 2024
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 51 (7) , 256-261
Ionization Waves Initiating Single-Electrode Breakdown in Long Discharge Tubes
Ionization waves (IWs) of positive polarity are studied experimentally in several sealed discharge tubes containing neon at pressures of 0.6‒15 Torr
- Open Access
- 1 January 2024
- Published by Herzen State Pedagogical University of Russia
- Vol. 5 (3) , 129–134
Decay of metastable atoms in the afterglow of single-electrode breakdown
This paper deals with experimental studies of ionization waves igniting the breakdown in long discharge tubes in neon at low pressures. Ionization waves were produced by rectangular voltage pulses applied to the high-voltage electrode of the discharge tube. Our research focused on concentration measurements of neon excited atoms at the metastable 1s5(3P2) level after the ionization wave passage and the breakdown termination. We also found the characteristic decay times of these states and the most significant elementary processes responsible for metastable atom deactivation. Проведены экспериментальные исследования волн ионизации, которые предваряют пробой в длинных разрядных трубках в неоне при низком давлении. Волны ионизации возникали при подаче прямоугольных импульсов напряжения на высоковольтный электрод разрядной трубки. Измерены концентрации атомов неона на метастабильном уровне 1s5(3P2), возникших после прохождения волны ионизации и окончания пробоя. Определены характерные времена распада этих состояний и элементарные процессы, ответственные за гибель метастабильных атомов в наиболее значительной степени.
- 1 January 2024
- Published by Herzen State Pedagogical University of Russia
- Vol. 5 (3) , 129–134
Open AccessDecay of metastable atoms in the afterglow of single-electrode breakdown
This paper deals with experimental studies of ionization waves igniting the breakdown in long discharge tubes in neon at low pressures. Ionization waves were produced by rectangular voltage pulses applied to the high-voltage electrode of the discharge tube. Our research focused on concentration measurements of neon excited atoms at the metastable 1s5(3P2) level after the ionization wave passage and the breakdown termination. We also found the characteristic decay times of these states and the most significant elementary processes responsible for metastable atom deactivation. Проведены экспериментальные исследования волн ионизации, которые предваряют пробой в длинных разрядных трубках в неоне при низком давлении. Волны ионизации возникали при подаче прямоугольных импульсов напряжения на высоковольтный электрод разрядной трубки. Измерены концентрации атомов неона на метастабильном уровне 1s5(3P2), возникших после прохождения волны ионизации и окончания пробоя. Определены характерные времена распада этих состояний и элементарные процессы, ответственные за гибель метастабильных атомов в наиболее значительной степени.
- 11 October 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 57 (1) , 015204
Hindering breakdown in a long discharge tube by visible spectrum light illumination
The effect of irradiation with visible spectrum light on breakdown in discharge tubes 75–80 cm long and 1.5 cm in inner diameter in rare gases at a pressure of ∼1 Torr was studied. A ramp voltage of variable slope in the range of ∼10–1–105 kV s−1 was applied to the tube anode. The tube was illuminated by radiation from fluorescent lamps operating in a continuous mode, as well as by LEDs or a laser diode operating in a pulsed mode. The breakdown voltage and the pre-breakdown ionization wave (IW) velocity were measured. Illumination led to a change in the breakdown potential. The sign of this change depended on the anode voltage rise rate dU/dt. At dU/dt > 102–103 kV s−1, the breakdown voltage decreased. A similar effect was observed earlier and was explained by the appearance of electrons in the discharge gap under the light action, as a result of which the breakdown delay time decreased. This, in turn, caused a decrease in the breakdown voltage. At dU/dt < 101–102 kV s−1, on the contrary, the breakdown potential increased; at dU/dt ∼ 0.1 kV s−1, this increase could reach 5–6 times. The dependence of the observed effect on the radiation intensity, its wavelength, and the illuminated area position on the tube surface is studied. The pre-breakdown IW behaved in an unusual way under these conditions: its velocity and the signal amplitude recorded by the capacitive probe increased when moving from the high-voltage anode to the cathode. It is assumed that the observed features are caused by the desorption of weakly bound electrons from the tube wall surface under the action of irradiation. These electrons create a current that charges the wall near the anode. Since the first stage of discharge ignition is the initial breakdown between the anode and the tube wall, the anode potential for such a breakdown should increase, which means an increase in the breakdown voltage. Additional experiments with the initiation of a preliminary IW by a pulse applied to the cathode, confirmed the existence of a charge on the wall near the anode.
- 11 October 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 57 (1) , 015204
Hindering breakdown in a long discharge tube by visible spectrum light illumination
The effect of irradiation with visible spectrum light on breakdown in discharge tubes 75–80 cm long and 1.5 cm in inner diameter in rare gases at a pressure of ∼1 Torr was studied. A ramp voltage of variable slope in the range of ∼10–1–105 kV s−1 was applied to the tube anode. The tube was illuminated by radiation from fluorescent lamps operating in a continuous mode, as well as by LEDs or a laser diode operating in a pulsed mode. The breakdown voltage and the pre-breakdown ionization wave (IW) velocity were measured. Illumination led to a change in the breakdown potential. The sign of this change depended on the anode voltage rise rate dU/dt. At dU/dt > 102–103 kV s−1, the breakdown voltage decreased. A similar effect was observed earlier and was explained by the appearance of electrons in the discharge gap under the light action, as a result of which the breakdown delay time decreased. This, in turn, caused a decrease in the breakdown voltage. At dU/dt < 101–102 kV s−1, on the contrary, the breakdown potential increased; at dU/dt ∼ 0.1 kV s−1, this increase could reach 5–6 times. The dependence of the observed effect on the radiation intensity, its wavelength, and the illuminated area position on the tube surface is studied. The pre-breakdown IW behaved in an unusual way under these conditions: its velocity and the signal amplitude recorded by the capacitive probe increased when moving from the high-voltage anode to the cathode. It is assumed that the observed features are caused by the desorption of weakly bound electrons from the tube wall surface under the action of irradiation. These electrons create a current that charges the wall near the anode. Since the first stage of discharge ignition is the initial breakdown between the anode and the tube wall, the anode potential for such a breakdown should increase, which means an increase in the breakdown voltage. Additional experiments with the initiation of a preliminary IW by a pulse applied to the cathode, confirmed the existence of a charge on the wall near the anode.
- 1 November 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (11) , 114010
Breakdown voltage in long tubes: the effect of surface charge
The study focuses on ignition processes in long discharge tubes (the length of which is large compared to the diameter) in rare gases Ne, Ar, and their mixture at a low pressure (∼1 Torr). Gas breakdown was caused by ramp voltage pulses of positive or negative polarity applied to the active electrode. The breakdown voltage was determined by the voltage drop at breakdown. The emission of the ionization wave (IW) preceding the breakdown was explored. The discharge tubes were exposed to two types of external influences. The first was illumination of the tube cathode with visible spectrum light, while the second was the constant or pulsed bias of the cathode potential by a value lower than that of maintaining discharge. In both cases the breakdown voltage increased up to doubling under some conditions. The observation of the IW revealed the presence of extra waves preceding the regular pre-breakdown IW. The extra wave velocity and emission intensity differed from those of the regular waves. Their main feature is that they do not overcome the entire inter-electrode gap, but weaken and disappear in between. It is assumed that the extra waves deposit the wall surface charge, which in turn affects the breakdown voltage. The increased breakdown voltage value remains for tens of minutes, which could indicate the surface charge lifetime of the same order. This was confirmed by direct wall-potential measurements using an electrostatic voltmeter.
- 1 November 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (11) , 114010
Breakdown voltage in long tubes: the effect of surface charge
The study focuses on ignition processes in long discharge tubes (the length of which is large compared to the diameter) in rare gases Ne, Ar, and their mixture at a low pressure (∼1 Torr). Gas breakdown was caused by ramp voltage pulses of positive or negative polarity applied to the active electrode. The breakdown voltage was determined by the voltage drop at breakdown. The emission of the ionization wave (IW) preceding the breakdown was explored. The discharge tubes were exposed to two types of external influences. The first was illumination of the tube cathode with visible spectrum light, while the second was the constant or pulsed bias of the cathode potential by a value lower than that of maintaining discharge. In both cases the breakdown voltage increased up to doubling under some conditions. The observation of the IW revealed the presence of extra waves preceding the regular pre-breakdown IW. The extra wave velocity and emission intensity differed from those of the regular waves. Their main feature is that they do not overcome the entire inter-electrode gap, but weaken and disappear in between. It is assumed that the extra waves deposit the wall surface charge, which in turn affects the breakdown voltage. The increased breakdown voltage value remains for tens of minutes, which could indicate the surface charge lifetime of the same order. This was confirmed by direct wall-potential measurements using an electrostatic voltmeter.
- 1 March 2020
- Published by IOP Publishing in Plasma Research Express
- Vol. 2 (1) , 015012
Low-frequency one-electrode discharge in long tubes at low gas pressure
One electrode discharge (OED) was studied in long tubes filled with high purity neon or argon at a pressure of 1–4 Torr. The main feature of the discharge is a low rate (less than 10 kHz) of the voltage pulses of given polarity applied to only one electrode, while another one remains free or missing. The discharge is observed as a glowing plasma column which occupies either the whole tube or its part depending on actual voltage amplitude and rate. Current-volt characteristics, ignition thresholds and the OED length changing patterns demonstrate features unknown for RF discharges. It was found that the plasma generation mechanism actually is a formation of a set of ionization waves (IW). As a result, the discharge glow as well as its current can be presented as a set of pulses with duration equal to the IW propagation time (∼1 μ s) that appear with the voltage frequency. The pulse form reflects the IW structure which represents itself as a front of high electrical potential and a plasma channel linking it with the electrode. It was shown that the wave motion is characterized by an attenuation of which the patterns were investigated by the time-position diagrams method. The attenuation specifies the length of the occupied plasma area as well as other OED parameters. The proposed simplified kinematic model of the wave propagation is based on the assumption that the attenuation is caused by the IW front potential decrease which in its turn occurs due to exponential falling of electric field strength in the plasma channel. This model allows to estimate the electric field in different OED points as well as to define average electron concentration via the current measurements. Typical values of the above parameters are 5 V cm −1 · Torr and 10 9 –10 10 cm −3 .
- 1 March 2020
- Published by IOP Publishing in Plasma Research Express
- Vol. 2 (1) , 015012
Low-frequency one-electrode discharge in long tubes at low gas pressure
One electrode discharge (OED) was studied in long tubes filled with high purity neon or argon at a pressure of 1–4 Torr. The main feature of the discharge is a low rate (less than 10 kHz) of the voltage pulses of given polarity applied to only one electrode, while another one remains free or missing. The discharge is observed as a glowing plasma column which occupies either the whole tube or its part depending on actual voltage amplitude and rate. Current-volt characteristics, ignition thresholds and the OED length changing patterns demonstrate features unknown for RF discharges. It was found that the plasma generation mechanism actually is a formation of a set of ionization waves (IW). As a result, the discharge glow as well as its current can be presented as a set of pulses with duration equal to the IW propagation time (∼1 μ s) that appear with the voltage frequency. The pulse form reflects the IW structure which represents itself as a front of high electrical potential and a plasma channel linking it with the electrode. It was shown that the wave motion is characterized by an attenuation of which the patterns were investigated by the time-position diagrams method. The attenuation specifies the length of the occupied plasma area as well as other OED parameters. The proposed simplified kinematic model of the wave propagation is based on the assumption that the attenuation is caused by the IW front potential decrease which in its turn occurs due to exponential falling of electric field strength in the plasma channel. This model allows to estimate the electric field in different OED points as well as to define average electron concentration via the current measurements. Typical values of the above parameters are 5 V cm −1 · Torr and 10 9 –10 10 cm −3 .
- 3 May 2019
- Published by IOP Publishing in Plasma Research Express
- Vol. 1 (2) , 025004
Collision of ionization waves in long discharge tubes
This research focuses on interaction of ionization waves (IW) generated in long discharge tubes (1 m length and 1.5 cm in diameter) filled with neon or argon under pressure about 1 Torr and, in particular, on simplest case of such interference which is collision of the opposite directed IW of positive polarity. The waves were triggered from two electrodes of the tube by simultaneous application of the same high voltage pulse and propagated toward the tube center until their collision. Space and time stability of the collisions was achieved via decreasing time delay of the initial breakdowns which trigger IW by employment of both memory effect and photo-desorption of wall surface electrons. Significant memory effect occurred for the pulse repetition rate over 100 Hz. Multiple IW transition from the electrode forms specific one-electrode discharge; as a result the problem of IW collision was transformed into the observation of two opposite one-electrode discharges interaction. Patterns of IW interfering were registered via deviation of their kinematic characteristics ( x - t diagrams) from ones for non-collided wave. This method shows that two ionization waves travel toward each other with decreasing speeds and subsequent degradation of the emission. An area near the tube center where IWs emission was not detected was considered as the IW suppression zone. The zone width depends on voltage amplitude, gas type and pressure.
- 3 May 2019
- Published by IOP Publishing in Plasma Research Express
- Vol. 1 (2) , 025004
Collision of ionization waves in long discharge tubes
This research focuses on interaction of ionization waves (IW) generated in long discharge tubes (1 m length and 1.5 cm in diameter) filled with neon or argon under pressure about 1 Torr and, in particular, on simplest case of such interference which is collision of the opposite directed IW of positive polarity. The waves were triggered from two electrodes of the tube by simultaneous application of the same high voltage pulse and propagated toward the tube center until their collision. Space and time stability of the collisions was achieved via decreasing time delay of the initial breakdowns which trigger IW by employment of both memory effect and photo-desorption of wall surface electrons. Significant memory effect occurred for the pulse repetition rate over 100 Hz. Multiple IW transition from the electrode forms specific one-electrode discharge; as a result the problem of IW collision was transformed into the observation of two opposite one-electrode discharges interaction. Patterns of IW interfering were registered via deviation of their kinematic characteristics ( x - t diagrams) from ones for non-collided wave. This method shows that two ionization waves travel toward each other with decreasing speeds and subsequent degradation of the emission. An area near the tube center where IWs emission was not detected was considered as the IW suppression zone. The zone width depends on voltage amplitude, gas type and pressure.
- Open Access
Collision of Ionization Waves in Long Discharge Tubes
This research focuses on interaction of ionization waves (IW) generated in long discharge tubes (1 m length and 1.5 cm in diameter) filled with neon or argon under pressure about 1 Torr and, in particular, on simplest case of such interference which is collision of the opposite directed IW of positive polarity. The waves were triggered from two electrodes of the tube by simultaneous application of the same high voltage pulse and propagated toward the tube center until their collision. Space and time stability of the collisions was achieved via decreasing time delay of the initial breakdowns which trigger IW by employment of both memory effect and photo-desorption of wall surface electrons. Significant memory effect occurred for the pulse repetition rate over 100Hz. Multiple IW transition from the electrode forms specific one-electrode discharge; as a result the problem of IW collision was transformed into the observation of two opposite one-electrode discharges interaction. Patterns of IW interfering were registered via deviation of their kinematic characteristics (x-t diagrams) from ones for non-collided wave. This method shows that two ionization waves travel toward each other with decreasing speeds and subsequent degradation of the emission. An area near the tube center where IWs emission was not detected was considered as the IW suppression zone. The zone width depends on voltage amplitude, gas type and pressure.
Open AccessCollision of Ionization Waves in Long Discharge Tubes
This research focuses on interaction of ionization waves (IW) generated in long discharge tubes (1 m length and 1.5 cm in diameter) filled with neon or argon under pressure about 1 Torr and, in particular, on simplest case of such interference which is collision of the opposite directed IW of positive polarity. The waves were triggered from two electrodes of the tube by simultaneous application of the same high voltage pulse and propagated toward the tube center until their collision. Space and time stability of the collisions was achieved via decreasing time delay of the initial breakdowns which trigger IW by employment of both memory effect and photo-desorption of wall surface electrons. Significant memory effect occurred for the pulse repetition rate over 100Hz. Multiple IW transition from the electrode forms specific one-electrode discharge; as a result the problem of IW collision was transformed into the observation of two opposite one-electrode discharges interaction. Patterns of IW interfering were registered via deviation of their kinematic characteristics (x-t diagrams) from ones for non-collided wave. This method shows that two ionization waves travel toward each other with decreasing speeds and subsequent degradation of the emission. An area near the tube center where IWs emission was not detected was considered as the IW suppression zone. The zone width depends on voltage amplitude, gas type and pressure.
- 24 July 2018
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 51 (33) , 335202
Triggering of the breakdown in a discharge tube by visible-spectrum light pulses
The influence of the pulses of visible-spectrum light on the breakdown in a discharge tube was studied experimentally. The tube of 80 cm length and 1.5 cm inner diameter contained neon at a pressure of 0.6 Torr. High-voltage rectangular or ramp pulses were applied to the anode. The light pulses of 0.1–100 µ s duration were produced by the light-emitting diode or laser diode at a wavelength of 460 and 407 nm, respectively. A small area of the tube wall near the anode was illuminated at different moments after or before the voltage pulse onset. It has been found that the light pulse exerts the strongest influence on the breakdown. In the case of rectangular pulse, it drastically decreases the statistical delay time of the breakdown. As a result, all the breakdowns, which did not happen before the light pulse, occur during several microseconds after its onset. The light pulse influences the breakdown delay time even if it terminates before the voltage pulse onset. This can be explained by the finite lifetime of the secondary electrons produced by the light. In the case of the ramp voltage pulse, an essential decrease in the breakdown voltage scatter is observed under illumination. The effect is especially pronounced if the light pulse is applied at the moment when the anode voltage is equal to or somewhat lower than the minimum breakdown voltage. For later moments, the breakdown voltages are strictly bounded by both sides. The average breakdown voltage decreases noticeably. As for the mechanism responsible for the observed effect, electron photodesorption from the tube wall is suggested. This process presumably occurs in dielectric barrier discharge at atmospheric pressure where it can influence the breakdown voltage and provide synchronous breakdown of micro discharges, thus causing the formation of multiple filaments.
- 24 July 2018
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 51 (33) , 335202
Triggering of the breakdown in a discharge tube by visible-spectrum light pulses
The influence of the pulses of visible-spectrum light on the breakdown in a discharge tube was studied experimentally. The tube of 80 cm length and 1.5 cm inner diameter contained neon at a pressure of 0.6 Torr. High-voltage rectangular or ramp pulses were applied to the anode. The light pulses of 0.1–100 µ s duration were produced by the light-emitting diode or laser diode at a wavelength of 460 and 407 nm, respectively. A small area of the tube wall near the anode was illuminated at different moments after or before the voltage pulse onset. It has been found that the light pulse exerts the strongest influence on the breakdown. In the case of rectangular pulse, it drastically decreases the statistical delay time of the breakdown. As a result, all the breakdowns, which did not happen before the light pulse, occur during several microseconds after its onset. The light pulse influences the breakdown delay time even if it terminates before the voltage pulse onset. This can be explained by the finite lifetime of the secondary electrons produced by the light. In the case of the ramp voltage pulse, an essential decrease in the breakdown voltage scatter is observed under illumination. The effect is especially pronounced if the light pulse is applied at the moment when the anode voltage is equal to or somewhat lower than the minimum breakdown voltage. For later moments, the breakdown voltages are strictly bounded by both sides. The average breakdown voltage decreases noticeably. As for the mechanism responsible for the observed effect, electron photodesorption from the tube wall is suggested. This process presumably occurs in dielectric barrier discharge at atmospheric pressure where it can influence the breakdown voltage and provide synchronous breakdown of micro discharges, thus causing the formation of multiple filaments.
- 31 May 2017
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 26 (6) , 065017
Processes of discharge ignition in long tubes at low gas pressure
Electrical breakdown resulting in the ignition of a low-pressure low-current glow discharge is investigated in long (length much larger than the diameter) tubes. New features characterizing the breakdown are found. Breakdown begins with synchronous sharp drop of the anode voltage and the peak in the anode current, which is not accompanied by the current at the grounded cathode. This proves the existence of the first (initial) breakdown occurring between the high-voltage electrode and the nearby section of the tube wall. Simultaneously, an ionization wave starts from the anode. The cathode current initiates noticeably later, at the moment when the ionization wave reaches the cathode. The distribution of the breakdown statistic delay time is governed by the Laue law. This study has revealed a profound effect on the breakdown of illumination of the tubes by visible-spectrum light. Illumination diminishes the average breakdown delay time; for the breakdown mode when breakdown occurs at the pulse leading edge this leads to a decrease in the average breakdown voltage. The long-wavelength threshold of the effect is 520 nm. Electron photodesorption from the wall surface is supposed to be the mechanism of the effect. Quantum efficiency for this process is 0.6 × 10 −9 . Unlike in most previous studies, all the measurements were carried out with unshielded tubes; screening of the tube by a grounded shield has a strong influence on the breakdown characteristics.
- 31 May 2017
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 26 (6) , 065017
Processes of discharge ignition in long tubes at low gas pressure
Electrical breakdown resulting in the ignition of a low-pressure low-current glow discharge is investigated in long (length much larger than the diameter) tubes. New features characterizing the breakdown are found. Breakdown begins with synchronous sharp drop of the anode voltage and the peak in the anode current, which is not accompanied by the current at the grounded cathode. This proves the existence of the first (initial) breakdown occurring between the high-voltage electrode and the nearby section of the tube wall. Simultaneously, an ionization wave starts from the anode. The cathode current initiates noticeably later, at the moment when the ionization wave reaches the cathode. The distribution of the breakdown statistic delay time is governed by the Laue law. This study has revealed a profound effect on the breakdown of illumination of the tubes by visible-spectrum light. Illumination diminishes the average breakdown delay time; for the breakdown mode when breakdown occurs at the pulse leading edge this leads to a decrease in the average breakdown voltage. The long-wavelength threshold of the effect is 520 nm. Electron photodesorption from the wall surface is supposed to be the mechanism of the effect. Quantum efficiency for this process is 0.6 × 10 −9 . Unlike in most previous studies, all the measurements were carried out with unshielded tubes; screening of the tube by a grounded shield has a strong influence on the breakdown characteristics.