Jörn Voigt
Jörn Voigt has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Christian Marzahl
Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU)
2 shared publications Christopher Krause
Institute for Experimental Immunology, EUROIMMUN, Seekamp 31, 23560 Lübeck, Germany
2 shared publications- Agnes C. Gläsel
Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology Justus‐Liebig‐University Giessen Germany
1 shared publication Alina Langenhagen
Freie Universität Berlin
1 shared publication- Andreas Maier
Friedrich-Alexander-Universität Erlangen-Nürnberg
1 shared publication Anne Katherine Jasensky
Laboklin GmbH und Co. KG
1 shared publication
Latest Publications
- Open Access
- 27 February 2021
- Published by Springer Nature
- p. 296
Abstract: Are Fast Labeling Methods Reliable?
- 27 February 2021
- Published by Springer Nature
- p. 296
Open AccessAbstract: Are Fast Labeling Methods Reliable?
- 7 February 2019
- Published by Springer Nature
- p. 37-42
Synthetic Training with Generative Adversarial Networks for Segmentation of Microscopies
- 7 February 2019
- Published by Springer Nature
- p. 37-42
Synthetic Training with Generative Adversarial Networks for Segmentation of Microscopies
- Open Access
- 25 October 2015
- Published by Wiley in Journal of Immunology Research
- Vol. 2015, 1-8
Automated Evaluation ofCrithidia luciliaeBased Indirect Immunofluorescence Tests: A Novel Application of the EUROPattern-Suite Technology
Systemic lupus erythematosus (SLE) is a severe rheumatic autoimmune disease with various clinical manifestations. Anti-dsDNA antibodies are an important immunological hallmark of SLE and their occurrence represents a major criterion for the diagnosis. Among the commonly applied test systems for determination of anti-dsDNA antibodies, the indirect immunofluorescence test (IIFT) using the flagellatedkinetoplastida Crithidia luciliaeis considered to be highly disease specific at moderate sensitivity. Since IIFT, however, is claimed to be affected by subjective interpretation and a lack of standardization, there has been an increasing demand for automated pattern interpretation of immunofluorescence reactions in recent years. Corresponding platforms are already available for evaluation of anti-nuclear antibody (ANA) IIFT on HEp-2 cells, the recommended “gold standard” for ANA screening in the diagnosis of various systemic rheumatic autoimmune diseases. For one of these systems, the “EUROPattern-Suite” computer-aided immunofluorescence microscopy (CAIFM), automated interpretation of microscopic fluorescence patterns was extended to theCrithidia luciliaebased anti-dsDNA IIFT.
- 25 October 2015
- Published by Wiley in Journal of Immunology Research
- Vol. 2015, 1-8
Open AccessAutomated Evaluation ofCrithidia luciliaeBased Indirect Immunofluorescence Tests: A Novel Application of the EUROPattern-Suite Technology
Systemic lupus erythematosus (SLE) is a severe rheumatic autoimmune disease with various clinical manifestations. Anti-dsDNA antibodies are an important immunological hallmark of SLE and their occurrence represents a major criterion for the diagnosis. Among the commonly applied test systems for determination of anti-dsDNA antibodies, the indirect immunofluorescence test (IIFT) using the flagellatedkinetoplastida Crithidia luciliaeis considered to be highly disease specific at moderate sensitivity. Since IIFT, however, is claimed to be affected by subjective interpretation and a lack of standardization, there has been an increasing demand for automated pattern interpretation of immunofluorescence reactions in recent years. Corresponding platforms are already available for evaluation of anti-nuclear antibody (ANA) IIFT on HEp-2 cells, the recommended “gold standard” for ANA screening in the diagnosis of various systemic rheumatic autoimmune diseases. For one of these systems, the “EUROPattern-Suite” computer-aided immunofluorescence microscopy (CAIFM), automated interpretation of microscopic fluorescence patterns was extended to theCrithidia luciliaebased anti-dsDNA IIFT.
- Open Access
- 11 November 2012
- Published by Wiley in Journal of Immunology Research
- Vol. 2012, 1-7
Automated Indirect Immunofluorescence Evaluation of Antinuclear Autoantibodies on HEp-2 Cells
Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF incubation in the market, the automation of result evaluation is still in its infancy. Therefore, the EUROPattern Suite has been developed as a comprehensive automated processing and interpretation system for standardized and efficient ANA detection by HEp-2 cell-based IIF. In this study, the automated pattern recognition was compared to conventional visual interpretation in a total of 351 sera. In the discrimination of positive from negative samples, concordant results between visual and automated evaluation were obtained for 349 sera (99.4%, kappa = 0.984). The system missed out none of the 272 antibody-positive samples and identified 77 out of 79 visually negative samples (analytical sensitivity/specificity: 100%/97.5%). Moreover, 94.0% of all main antibody patterns were recognized correctly by the software. Owing to its performance characteristics, EUROPattern enables fast, objective, and economic IIF ANA analysis and has the potential to reduce intra- and interlaboratory variability.
- 11 November 2012
- Published by Wiley in Journal of Immunology Research
- Vol. 2012, 1-7
Open AccessAutomated Indirect Immunofluorescence Evaluation of Antinuclear Autoantibodies on HEp-2 Cells
Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF incubation in the market, the automation of result evaluation is still in its infancy. Therefore, the EUROPattern Suite has been developed as a comprehensive automated processing and interpretation system for standardized and efficient ANA detection by HEp-2 cell-based IIF. In this study, the automated pattern recognition was compared to conventional visual interpretation in a total of 351 sera. In the discrimination of positive from negative samples, concordant results between visual and automated evaluation were obtained for 349 sera (99.4%, kappa = 0.984). The system missed out none of the 272 antibody-positive samples and identified 77 out of 79 visually negative samples (analytical sensitivity/specificity: 100%/97.5%). Moreover, 94.0% of all main antibody patterns were recognized correctly by the software. Owing to its performance characteristics, EUROPattern enables fast, objective, and economic IIF ANA analysis and has the potential to reduce intra- and interlaboratory variability.