DFDennis J. Fasbinder

Dennis J. Fasbinder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dennis J. Fasbinder has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Gisele F. Neiva

    Clinical Professor, Graduate Restorative Dentistry Program Director, Department of Cariology, Restorative Sciences & Endodontics University of Michigan School of Dentistry Ann Arbor Michigan USA

    3 shared publications
  • Donald Heys

    Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan

    2 shared publications
  • Geetha Duddanahalli Siddanna

    Cariology, Restorative Sciences and Endodontics University of Michigan School of Dentistry Ann Arbor Michigan USA

    2 shared publications
  • Joseph B. Dennison

    2 shared publications
  • Amy E. Karpenko

    Cariology, Restorative Sciences and Endodontics University of Michigan School of Dentistry Ann Arbor Michigan USA

    1 shared publication
  • Andre J. Valcanaia

    Graduate Restorative Dentistry Program Associate Director, Department of Cariology, Restorative Sciences & Endodontics University of Michigan School of Dentistry Ann Arbor Michigan USA

    1 shared publication

Latest Publications

  • Open Access

    Virtual clinic: Applying technology to expand dental school walls

    by Geetha Duddanahalli Siddanna, Amy E. Karpenko, Andrea Mantesso, Stephen J. Sterlitz, Dennis J. Fasbinder

    Dental education traditionally requires the use of dedicated fixed preclinic facilities to provide clinically relevant experiences to support the development of dexterity, critical thinking, and self‐assessment skills that are essential for excellent patient care. As a result of the social distancing guidelines instituted at the height of the COVID pandemic, dental education was severely affected when education pivoted to remote instruction and had significant restrictions on in‐person training. This study evaluated a novel application of modern technology to allow students to perform clinically relevant hands‐on exercises away from dental school and, most importantly, receive feedback on their performance as an aid in their development. Student surveys and a comparison of pre‐ and post‐COVID grades were used to evaluate the effectiveness of the virtual clinic to support remote dental education.


  • Surface Evaluation of Resilient CAD/CAM ceramics after Contouring and Polishing

    by Geetha Duddanahalli Siddanna, Andre J. Valcanaia, Pilar Herrera Fierro, Gisele F. Neiva, Dennis J. Fasbinder

    Objective: This in‐vitro study measured the differences in surface roughness for computer assisted design/computer assisted manufacturing (CAD/CAM) resilient ceramic and CAD/CAM composite materials.Materials and Methods: The materials included Lava Ultimate (3 M), Cerasmart (GC America), Vita Enamic (Vita Zahnfabrik), and Brilliant Crios (Coltene). One calibrated operator polished each material with three polishing sytems: spiral polishers (Diacomp FeatherLite/Brasseler), rubbercup polishers (Enhance/DentsplyCaulk), and brush‐paste (Diashine/VH Technologies). Surface roughness was assessed using a confocal laser microscope (Lext OLS4000/Olympus).Results: A two‐way ANOVA revealed statistically significant differences in mean surface roughness values (Sa) among materials and polishers. Tukey multiple comparisons showed that mean Sa values for Lava Ultimate, Enamic, Cerasmart and Brilliant Crios polished with brush‐paste as well as Lava Ultimate and Cerasmart values polished with spiral polishers were not significantly different from each other.Conclusions: The finished surfaces were significantly smoother than milled surfaces for all materials. The brush‐paste polishing technique created the lowest surface roughness values for all CAD/CAM materials and values were comparable to what was achieved by spiral polishers for Lava Ultimate and Cerasmart. Rubber polishers did not provide a clinically smooth surface for CAD/CAM resilient ceramic/composite materials.Clinical significance: The results of the study indicate that polishing creates smooth surfaces for CAD/CAM resilient ceramic and CAD/CAM composite restorations.


  • Tooth‐cusp preservation with lithium disilicate onlay restorations: A fatigue resistance study

    by Elizabeth Griffis, Islam Abd Alraheam, Lee Boushell, Terrence Donovan, Dennis Fasbinder, Taiseer A. Sulaiman

    Objectives This study examined the in vitro fatigue resistance of maxillary premolars with 2 mm or 3 mm preserved cusp thicknesses restored with lithium disilicate onlays. Materials and Methods Premolars(N = 48) were divided into six groups. Onlays for groups 1 to 4 preserved a 3 mm functional (G1), 2 mm functional (G2), 3 mm nonfunctional (G3), or 2 mm nonfunctional (G4) buccal‐lingual cusp width. Onlays for group 5 (G5, control) replaced both cusps. Group 6 (G6) samples were identical to G1 with added retentive boxes. Lithium disilicate onlays were exposed to thermocycling (10 000 cycles, 5°C‐55°C, 30s/cycle) and mechanical loading (1.2 million cycles at 1.4 Hz and 70 N). All samples were examined for onlay debonding or cusp or onlay fracture. Results Failure rates were 75%(G1), 0.0%(G2), 12.5%(G3), 0.0%(G4), 0.0%(G5), and 0.0%(G6). The difference in percent failure between the groups preserving the functional cusps (37.5%) and the groups preserving the nonfunctional cusps (6.3%) was statistically significant (P = .04; 95%CI:2.11‐55.66). No cusp or restoration fractures were observed; all failures were due to debonding of the restoration. Conclusion Teeth with thin remaining cusps that were restored with bonded lithium disilicate onlay restorations were not prone to fracture. Retentive preparation features that physically eliminated lateral displacement prevented onlay debonding even though the ceramic‐enamel margin was directly at the occlusal contact. Clinical significance The use of adhesively retained lithium disilicate ceramic onlays may be a viable alternative to full coverage restorations and may challenge traditionally accepted principals related to preparation resistance and retention form of ceramic partial coverage restorations.


  • Clinical evaluation of chairside Computer Assisted Design/Computer Assisted Machining nano‐ceramic restorations: Five‐year status

    by Dennis J. Fasbinder, Gisele F. Neiva, Donald Heys, Ronald Heys

    Objectives: This investigation was a longitudinal, randomized clinical trial to measure the clinical performance of a nano‐ceramic material (Lava Ultimate/3M) for chairside Computer Assisted Design/Computer Assisted Machining (CAD/CAM) fabricated restorations.Materials and Methods: One hundred and twenty chairside CAD/CAM onlays were restored with a CEREC system randomly assigned to 60 leucite‐reinforced ceramic (IPS EmpressCAD/Ivoclar Vivadent AGBendererstrasse 2FL‐9494 SchaanLiechtenstein) onlays and 60 nano‐ceramic (Lava Ultimate/3M) onlays. Equal groups of onlays were cemented using a self‐etch and a total etch adhesive resin cement. The onlays were recalled for a period of 5 years.Results: At 1 week postoperatively, 10% of the onlays cemented with both the self‐etch and total etch adhesive resin cements were reported as slightly sensitive. However, all patients were asymptomatic by the 4th week without treatment. Four leucite‐reinforced onlays and one nano‐ceramic onlay fractured and required replacement.Conclusions: Adhesive retention with a self‐etch or total etch cementation technique resulted in a similar clinical outcome with no reported debonds. The nano‐ceramic onlays had a lower incidence of fracture compared to the leucite‐reinforced ceramic onlays with both having a very low risk of fracture. Nano‐ceramic onlays performed equally as well as glass ceramic onlays over 5 years of clinical service.Clinical Significance: Ceramic materials have been a mainstay for chairside CAD/CAM restorations for the past 30 years and a new category of resilient ceramics with a resin matrix has been introduced reported to offer ceramic‐like durability and esthetics with resin‐like efficiency in handling. There are no long‐term clinical studies on the performance of these materials. This is a 5‐year randomized clinical trial on the performance of nano‐ceramic onlays.


  • Surface Evaluation of Polishing Techniques for New ResilientCAD/CAMRestorative Materials

    by Dennis J. Fasbinder, Gisele F. Neiva

    Purpose: The purpose of this study was to measure the surface roughness of milled chairside computer‐assisted design/computer assisted machining (CAD/CAM) restorations using several contouring/polishing systems as to their effectiveness for creating a clinically acceptable surface.Materials and Methods: One hundred onlays were milled from monolithicCAD/CAMblocks with anMCXLmilling chamber (SironaDental) as follows: 30 resin nano‐ceramic (LavaUltimate, 3M ESPE), 30 hybrid ceramic (Enamic,Vita) and 40 leucite‐reinforced ceramic (EmpressCAD,Ivoclar). A single group ofEmpressCADonlays was glazed‐fired in a porcelain oven (ProgramatCS2,Ivoclar). Finishing and polishing systems consisted of either an abrasive‐polish technique or a brush‐polish technique. Roughness values were measured using a three‐dimensional measuring laser microscope (OLS4000 LEXTbyOlympus).Results: There was a significant difference in the baseline surface roughness of theCAD/CAMmaterials (p ≤ 0.05), with the resin nano‐ceramic (LavaUltimate) being smoother than the hybrid ceramic (Enamic), and both being smoother than the leucite‐reinforced ceramic (EmpressCAD). All polishing techniques resulted in a smoother surface compared with the baseline surface for the leucite‐reinforced ceramic (p ≤ 0.05), with both techniques resulting in a significantly smoother surface than glazing in a porcelain oven (p ≤ 0.05). Both polishing techniques resulted in a smoother surface compared with the baseline surface for both the nano‐ceramic and hybrid ceramic materials (p ≤ 0.05).Conclusions: It is possible to create an equally smooth surface for chairsideCAD/CAMresilient materials compared with milled ceramics using several finishing and polishing techniques. In general, the polished ceramic surfaces were smoother than the glazed ceramic surfaces.Clinical Significance: The results of the study indicate that it is possible to create an equally smooth surface for chairsideCAD/CAMresilient materials compared with milled ceramics using several finishing and polishing techniques. In addition, both polishing techniques resulted in smoother ceramic surfaces when compared to glazed ceramic surfaces. The polished surface of the ceramic material was smoother than the glazed ceramic surface.


    • 1 January 2010
      • Vol. 13  (4) , 303-16

    Accuracy of occlusal contacts for crowns with chairside CAD/CAM techniques.

    by Dennis J Fasbinder, D J Poticny

    Information from the opposing dentition is used to design and fabricate occlusal contacts with a reasonable level of accuracy for a given restoration. The dental database with the antagonist design process utilizes a bite registration to propose the construction of a virtual opposing model. The Articulation design technique utilizes a functionally generated bite registration to control both the maximum intercuspation and excursive contacts on the restoration. Correlation design technique offers the opportunity to copy the established occlusal anatomy to the preparation. Although these techniques offer a workflow to establish occlusal contacts with the Cerec system, there is a lack of quantitative data as to the accuracy achieved. Alternative techniques to control the occlusal contacts have been suggested which rely on "user customized design techniques" that recommend altered program settings, manual override of automated features in the software, or modification of the established software design programs. The purpose of this study was to measure the occlusal vertical discrepancy for various design techniques. Full crowns made using dental database with the antagonist design technique had a significantly smaller occlusal vertical discrepancy than those made with correlation. Dental Database with the Antagonist had a significantly smaller occlusal vertical discrepancy than all suggested alternative design techniques. Use of the Dental Database with Antagonist design technique provides the most accurate technique for establishing occlusal contacts with the Cerec 3D system.


  • The clinical performance of CAD/CAM-generated composite inlays

    by Dennis J. Fasbinder, Joseph B. Dennison, Donald R. Heys, Kathrin Lampe