JMJohn Mark Meacham

John Mark Meacham

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John Mark Meacham has a total of 120 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Glass Microfluidic Bioelectrochemical Cell Platform for the Study of Extracellular Electron Uptake in Microbes

    by Andreea Stoica, Karthikeyan Rengasamy, Tahina O. Ranaivoarisoa, Joshua A. Van Dyke-Blodgett, Arpita Bose, J. Mark Meacham

    Miniaturization of microfluidic measurement systems offers several advantages, including reduced sample and reagent volumes, improved control over experimental conditions, and the ability to multiplex complementary measurement modalities, to enable new experimental approaches in microbial electrochemistry. We present a scalable glass-based microfluidic bioelectrochemical cell (µ-BEC) platform for multiplexed investigations of microbial extracellular electron uptake (EEU). The platform integrates eight independently addressable three-electrode cells in a 2×4 array, with transparent indium tin oxide working electrodes that support simultaneous electrochemical analysis and optical imaging. Systematic electrochemical characterization using the ferri/ferrocyanide redox couple demonstrated diffusion-controlled behavior and stable reference electrode performance, with well-to-well coefficients of variation in peak potentials of 0.6–1.5% and 0.6–1.1% for anodic and cathodic processes and device-to-device coefficients of variation of approximately 1.8% and 1.6%, respectively. Differential pulse voltammetry measurements demonstrated concentration-dependent electrochemical sensing over a three-order-of-magnitude range from 1 µM to 1 mM ferri/ferrocyanide, with peak currents exhibiting linear dependence on concentration for both anodic and cathodic processes across all tested wells. Biological compatibility was validated using the phototrophic bacteria Rhodopseudomonas palustris TIE-1, where reproducible light-dependent EEU was observed following 96 hours of incubation, and a reduction in current response after microfluidic removal of planktonic cells confirmed the contribution of surface attached cells to EEU. Together, these results establish the µ-BEC as a robust and reproducible microfluidic electrochemical platform suitable for parallelized, multimodal studies of microbial and abiotic electrochemical processes.

  • Low‐ and High‐Frequency Characterization of Hybrid Acoustofluidic Devices Using Motile Cells

    by Mingyang Cui, Advaith Narayan, Li Shan, Minji Kim, Andreea Stoica, Philip V. Bayly, J. Mark Meacham

    Acoustic microfluidics has become a powerful and robust tool for non‐contact, label‐free, and biocompatible manipulation of microscale bioparticles. However, current technologies are mostly confined to specialized research laboratories. Low operational consistency and repeatability are key barriers that impede realization of commercially viable platforms. Industrial and clinical applications also require real‐world performance monitoring. Thus, there is an urgent need for rapid and precise methods to experimentally characterize acoustofluidic devices. We propose to use the unicellular alga Chlamydomonas reinhardtii to assess the acoustic field within a hybrid acoustic microfluidic platform. Unlike the passive particles typically used for such measurements, C. reinhardtii cells swim freely and redistribute in the absence of a strong acoustic field, which allows a population of cells to represent a continuously changing acoustic pressure distribution. We use this method to characterize novel hybrid acoustofluidic devices that incorporate bulk acoustic waves generated by mode conversion of surface acoustic waves. Optimal low and high resonant frequencies of operation are identified, and acoustic pressure fields are imaged in real‐time using the distribution density of C. reinhardtii cells. Measurements confirm the high energy transfer efficiency of these hybrid devices, which are suitable for biocompatible trapping of microswimmers and other difficult‐to‐manipulate particles.

  • Open Access

    Microfluidic microbial bioreactors: How studying microbes at the microscale can help empower microbiology

    by Arpita Bose, Andreea Stoica, J Mark Meacham, Joshua A.V Blodgett

    Long before the existence of microbes was known, humans were unknowingly harnessing their power through practices

  • Open Access

    Robust acoustic trapping and perturbation of single-cell microswimmers illuminate three-dimensional swimming and ciliary coordination

    by Mingyang Cui, Susan K. Dutcher, Philip V. Bayly, J. Mark Meacham

    We report a label-free acoustic microfluidic method to confine single, cilia-driven swimming cells in space without limiting their rotational degrees of freedom. Our platform integrates a surface acoustic wave (SAW) actuator and bulk acoustic wave (BAW) trapping array to enable multiplexed analysis with high spatial resolution and trapping forces that are strong enough to hold individual microswimmers. The hybrid BAW/SAW acoustic tweezers employ high-efficiency mode conversion to achieve submicron image resolution while compensating for parasitic system losses to immersion oil in contact with the microfluidic chip. We use the platform to quantify cilia and cell body motion for wildtype biciliate cells, investigating effects of environmental variables like temperature and viscosity on ciliary beating, synchronization, and three-dimensional helical swimming. We confirm and expand upon the existing understanding of these phenomena, for example determining that increasing viscosity promotes asynchronous beating. Motile cilia are subcellular organelles that propel microorganisms or direct fluid and particulate flow. Thus, cilia are critical to cell survival and human health. The unicellular alga Chlamydomonas reinhardtii is widely used to investigate the mechanisms underlying ciliary beating and coordination. However, freely swimming cells are difficult to image with sufficient resolution to capture cilia motion, necessitating that the cell body be held during experiments. Acoustic confinement is a compelling alternative to use of a micropipette, or to magnetic, electrical, and optical trapping that may modify the cells and affect their behavior. Beyond establishing our approach to studying microswimmers, we demonstrate a unique ability to mechanically perturb cells via rapid acoustic positioning.


  • Open Access

    Microbes on a chip: How microfluidics can help us better understand and engineer electroactive microbes

    by Arpita Bose, Andreea Stoica, J.Mark Meacham

    Microbes on a chip: How microfluidics can help us better understand and engineer electroactive microbes: EEU is a relatively newly discovered process in microbiology. The Bose research group is bringing an interdisciplinary approach to understanding the molecular mechanisms behind EEU and how it can be engineered to provide potential solutions to the climate crisis. These solutions come from the capacity of some EEU-capable microbes to use chemical energy (chemoautotrophs) or light energy (photoautotrophs) in a process like photosynthesis to convert carbon dioxide (CO2) into biomass. EEU-capable chemoautotrophs and photoautotrophs are quite common in nature and could not only be used to remove CO2 from the environment but also to concurrently produce bioplastics or biofuels through microbial electrosynthesis.

  • Understanding and exploiting acoustic field-microswimmer interactions in acoustofluidic devices

    by J. Mark Meacham, Minji Kim, Mingyang Cui, Rune Barnkob

    Acoustic microfluidic devices offer exquisite control for manipulation of objects sized from tens of nanometers to tens of microns. Our work focuses on applying various acoustofluidic solutions to understand microswimmer behavior and the mechanisms underlying the beating of propulsive cilia/flagella. Ultrasonic trapping in bulk acoustic wave (BAW) and substrate acoustic wave (SAW) fields enables observation of swimming without constraining rotational degrees of freedom and without damaging the cells. Here, we summarize recent studies using biciliate C. reinhardtii algae cells, including three-dimensional body motion, synchronization/asynchronization of cis and trans cilia waveforms, and thermal and fluid-property effects. Acoustofluidic approaches provide unprecedented flexibility as a tool to investigate cell motility. Conversely, acoustic field-microswimmer interactions can also be exploited by applying the C. reinhardtii cells as dynamic probes to assess acoustofluidic device performance. We have previously reported use of these cells to identify optimal resonant frequencies of operation and to qualitatively map the strength of the acoustic field in BAW devices. Here, we extend the method to quantify the acoustic energy density of a straight microchannel operating at the first half-wavelength resonance, achieving agreement within 1 % to a standard method based on passive particle tracking. New applications for SAW devices are also presented.

  • Spray characteristics of an ultrasonic microdroplet generator with a continuously variable operating frequency

    by Li Shan, Mingyang Cui, J. Mark Meacham

    Droplet spraying is utilized in diverse industrial processes and biomedical applications, including nanomaterial synthesis, biomaterial handling, and inhalation drug delivery. Ultrasonic droplet generators transfer energy into bulk liquids using acoustic waves to disrupt the free liquid surface into fine microdroplets. We previously established a method combining ultrasonic actuation, resonant operation, and acoustic wave focusing for efficient spraying of various liquids (e.g., low surface tension fuels, high viscosity inks, and suspensions of biological cells). The microfabricated device comprises a piezoelectric transducer, sample reservoir, and an array of acoustic horn structures terminated by microscale orifices. Orifice size roughly dictates droplet diameter, and a fixed reservoir height prescribes specific device resonant frequencies of operation. Here, we incorporate a continuously variable liquid reservoir height for dynamic adjustment of operating parameters to improve spray efficiency in real-time and potentially tune the droplet size. Computational modeling predicts the system harmonic response for a range of reservoir heights from 0.5 to 3 mm (corresponding to operating frequencies from ∼500 kHz to 2.5 MHz). Nozzle arrays with 10, 20, and 40 μm orifices are evaluated for spray uniformity and stability of the active nozzles, using model predictions to explain the experimental observations.


  • Photoferrotrophy and phototrophic extracellular electron uptake is common in the marine anoxygenic phototroph Rhodovulum sulfidophilum

    by Dinesh Gupta, Michael S. Guzman, Karthikeyan Rengasamy, Andreea Stoica, Rajesh Singh, Tahina Onina Ranaivoarisoa, Emily J. Davenport, Wei Bai, Beau McGinley, J. Mark Meacham, et al.

    Photoferrotrophy allows anoxygenic phototrophs to use reduced iron as an electron donor for primary productivity. Recent work shows that freshwater photoferrotrophs can use electrons from solid-phase conductive substances via phototrophic extracellular electron uptake (pEEU), and the two processes share the underlying electron uptake mechanism. However, the ability of marine phototrophs to perform photoferrotrophy and pEEU, and the contribution of these processes to primary productivity is largely unknown. To fill this knowledge gap, we isolated 15 new strains of the marine anoxygenic phototroph Rhodovulum sulfidophilum on electron donors such as acetate and thiosulfate. We observed that all of the R. sulfidophilum strains isolated can perform photoferrotrophy. We chose strain AB26 as a representative strain to study further, and find that it can also perform pEEU from poised electrodes. We show that during pEEU, AB26 transfers electrons to the photosynthetic electron transport chain. Furthermore, systems biology-guided mutant analysis shows that R. sulfidophilum AB26 uses a previously unknown diheme cytochrome c protein, which we call EeuP, for pEEU but not photoferrotrophy. Homologs of EeuP occur in a range of widely distributed marine microbes. Overall, these results suggest that photoferrotrophy and pEEU contribute to the biogeochemical cycling of iron and carbon in marine ecosystems.


  • Thermal considerations for microswimmer trap-and-release using standing surface acoustic waves

    by Mingyang Cui, Minji Kim, Patricia B. Weisensee, J. Mark Meacham

    Controlled trapping of cells and microorganisms using substrate acoustic waves (SAWs; conventionally termed surface acoustic waves) has proven useful in numerous biological and biomedical applications owing to the label- and contact-free nature of acoustic confinement. However, excessive heating due to vibration damping and other system losses potentially compromises the biocompatibility of the SAW technique. Herein, we investigate the thermal biocompatibility of polydimethylsiloxane (PDMS)-based SAW and glass-based SAW [that supports a bulk acoustic wave (BAW) in the fluid domain] devices operating at different frequencies and applied voltages. First, we use infrared thermography to produce heat maps of regions of interest (ROI) within the aperture of the SAW transducers for PDMS- and glass-based devices. Motile Chlamydomonas reinhardtii algae cells are then used to test the trapping performance and biocompatibility of these devices. At low input power, the PDMS-based SAW system cannot generate a large enough acoustic trapping force to hold swimming C. reinhardtii cells. At high input power, the temperature of this device rises rapidly, damaging (and possibly killing) the cells. The glass-based SAW/BAW hybrid system, on the other hand, can not only trap swimming C. reinhardtii at low input power, but also exhibits better thermal biocompatibility than the PDMS-based SAW system at high input power. Thus, a glass-based SAW/BAW device creates strong acoustic trapping forces in a biocompatible environment, providing a new solution to safely trap active microswimmers for research involving motile cells and microorganisms.


  • Motile cells as probes for characterizing acoustofluidic devices

    by Minji Kim, Philip V. Bayly, J. Mark Meacham

    Acoustic microfluidics has emerged as a versatile solution for particle manipulation in medicine and biology. However, current technologies are largely confined to specialized research laboratories. The translation of acoustofluidics from research to clinical and industrial settings requires improved consistency and repeatability across different platforms. Performance comparisons will require straightforward experimental assessment tools that are not yet available. We introduce a method for characterizing acoustofluidic devices in real-time by exploiting the capacity of swimming microorganisms to respond to changes in their environment. The unicellular alga, Chlamydomonas reinhardtii, is used as an active probe to visualize the evolving acoustic pressure field within microfluidic channels and chambers. In contrast to more familiar mammalian cells, C. reinhardtii are simple to prepare and maintain, and exhibit a relatively uniform size distribution that more closely resembles calibration particles; however, unlike passive particles, these motile cells naturally fill complex chamber geometries and redistribute when the acoustic field changes or is turned off. In this way, C. reinhardtii cells offer greater flexibility than conventional polymer or glass calibration beads for in situ determination of device operating characteristics. To illustrate the technique, the varying spatial density and distribution of swimming cells are correlated to the acoustic potential to automatically locate device resonances within a specified frequency range. Peaks in the correlation coefficient of successive images not only identify the resonant frequencies for various geometries, but the peak shape can be related to the relative strength of the resonances. Qualitative mapping of the acoustic field strength with increasing voltage amplitude is also shown. Thus, we demonstrate that dynamically responsive C. reinhardtii enable real-time measurement and continuous monitoring of acoustofluidic device performance.