Zhi-Ce Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhi-Ce Zou has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Chang Song Li
College of Electrical Engineering and Information Technology, Sichuan University, Chengdu 610065, China
1 shared publicationDan Yue Wu
State Grid Fujian Electric Power Research Institute, State Grid Corporation of China, Fuzhou 350007, China
1 shared publication- Haibo Li
School of Mathematics and Statistics & Hubei Key Laboratory of Engineering Modeling and Scientific Computing, Huazhong University of Science and Technology
1 shared publication Jun Yao
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
1 shared publication- Jun Yao
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
1 shared publication - Keteng Jiang
Tsinghua Sichuan Energy, Internet Research Institute,Chengdu,China
1 shared publication
Latest Publications
- 1 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (8) , 1-5
Fault Protection of Urban Distribution Network Using a Superconducting Cable Joint
To enhance the operating security and stability of the cross-linked polyethylene power cable based urban distribution network due to conventional cable joint (CCJ) faults, this paper presents a novel superconducting fault current limitation scheme by using a superconducting cable joint (SCJ). The basic principle, circuit modeling, conceptual design and distribution network integrated with the SCJ are presented in detail. The comparative study without and with the proposed SCJ scheme and comprehensive evaluation are carried out. The simulation results obtained under symmetrical and asymmetrical CCJ faults show that the harmful large fault grid currents can be limited effectively and the fault grid voltage can be well improved. Thus the high temperature electric arc in the fault location caused by CCJ faults can be safely controlled. And large area power failure in actual power system can be avoided.
- 1 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (8) , 1-5
Fault Protection of Urban Distribution Network Using a Superconducting Cable Joint
To enhance the operating security and stability of the cross-linked polyethylene power cable based urban distribution network due to conventional cable joint (CCJ) faults, this paper presents a novel superconducting fault current limitation scheme by using a superconducting cable joint (SCJ). The basic principle, circuit modeling, conceptual design and distribution network integrated with the SCJ are presented in detail. The comparative study without and with the proposed SCJ scheme and comprehensive evaluation are carried out. The simulation results obtained under symmetrical and asymmetrical CCJ faults show that the harmful large fault grid currents can be limited effectively and the fault grid voltage can be well improved. Thus the high temperature electric arc in the fault location caused by CCJ faults can be safely controlled. And large area power failure in actual power system can be avoided.
- 8 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (8) , 1-3
Efficient HVRT Scheme of DFIG Using a SSFCL-Chopper Considering Grid Voltage Recovery
To enhance the dynamic high-voltage ride-through (HVRT) performance of doubly fed induction generator (DFIG) considering both the grid voltage swell and recovery influences, an efficient HVRT scheme is proposed by integrating a stator-side superconducting fault current limiter (SSFCL) with a dc-link chopper. The basic principle, circuit modeling, resistance setting, current-limiting characteristics design and coordinated control strategy of the SSFCL and chopper are presented to form an integrated protection scheme. As compared to a SSFCL or chopper-based HVRT scheme, the results obtained in the proposed SSFCL-chopper-based scheme show that the amplitudes of external and internal electromagnetic transient oscillations of the DFIG are largely reduced with shorter recovery time. This enhances significantly the HVRT behaviors in the DFIG considering grid voltage recovery.
- 8 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (8) , 1-3
Efficient HVRT Scheme of DFIG Using a SSFCL-Chopper Considering Grid Voltage Recovery
To enhance the dynamic high-voltage ride-through (HVRT) performance of doubly fed induction generator (DFIG) considering both the grid voltage swell and recovery influences, an efficient HVRT scheme is proposed by integrating a stator-side superconducting fault current limiter (SSFCL) with a dc-link chopper. The basic principle, circuit modeling, resistance setting, current-limiting characteristics design and coordinated control strategy of the SSFCL and chopper are presented to form an integrated protection scheme. As compared to a SSFCL or chopper-based HVRT scheme, the results obtained in the proposed SSFCL-chopper-based scheme show that the amplitudes of external and internal electromagnetic transient oscillations of the DFIG are largely reduced with shorter recovery time. This enhances significantly the HVRT behaviors in the DFIG considering grid voltage recovery.
- Open Access
- 9 February 2021
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 8
A Novel Methodology for Electric-Thermal Mixed Power Flow Simulation and Transmission Loss Analysis in Multi-Energy Micro-Grids
For urban electrical and thermal energy supply and consumption terminals, the multi-energy system is a way to realize the energy conversion and consumption efficiently, cleanly and economically. To further study the power flow character of multi-energy systems, additional factors such as electric-thermal coupling equipment, thermal flow rules should be taken into consideration. The traditional Newton-Raphson iteration method which has been commonly used for electrical power flow calculation must be expanded to electric-thermal mixed power flow. This paper realized a new expression of hot water temperature drop with the thermal supply pipe network. This expression modified the Sukhov cooling operator and intuitively revealed the impact factor of transmission loss in hot water pipes. As a result, mathematical descriptions of electricity, heat and hydraulic flow in a multi-energy system were established. With the modified Sukhov cooling operator, the mathematical model of the expanded Newton-Raphson fast iterative solution algorithm, together with its Jacobian matrix elements affected by the electro-thermal coupling relationship was derived. A regional electric-heat supply system was selected as an example to verify the effectiveness of the method. Results showed that the transmission loss in electrical grid is related with the power load while in thermal pipes it was mainly related with the ambient temperature.
- 9 February 2021
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 8
Open AccessA Novel Methodology for Electric-Thermal Mixed Power Flow Simulation and Transmission Loss Analysis in Multi-Energy Micro-Grids
For urban electrical and thermal energy supply and consumption terminals, the multi-energy system is a way to realize the energy conversion and consumption efficiently, cleanly and economically. To further study the power flow character of multi-energy systems, additional factors such as electric-thermal coupling equipment, thermal flow rules should be taken into consideration. The traditional Newton-Raphson iteration method which has been commonly used for electrical power flow calculation must be expanded to electric-thermal mixed power flow. This paper realized a new expression of hot water temperature drop with the thermal supply pipe network. This expression modified the Sukhov cooling operator and intuitively revealed the impact factor of transmission loss in hot water pipes. As a result, mathematical descriptions of electricity, heat and hydraulic flow in a multi-energy system were established. With the modified Sukhov cooling operator, the mathematical model of the expanded Newton-Raphson fast iterative solution algorithm, together with its Jacobian matrix elements affected by the electro-thermal coupling relationship was derived. A regional electric-heat supply system was selected as an example to verify the effectiveness of the method. Results showed that the transmission loss in electrical grid is related with the power load while in thermal pipes it was mainly related with the ambient temperature.
- 30 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (7) , 1-6
Cooperative Control of SFCL and Reactive Power for Improving the Transient Voltage Stability of Grid-Connected Wind Farm With DFIGs
This paper studies transient voltage stability in a 9-MW doubly-fed-induction-generator-based wind farm integrated with one superconducting fault current limiter (SFCL)-based passive voltage compensator and one transient voltage control (TVC)-based active voltage compensator. To achieve effective control manner, basic cooperative operation and modeling of the two voltage compensators are described. In addition, a technical discussion on the designs of proportional-integral parameters of the TVC and SFCL resistance are conducted. The effectively integrated system is highlighted with a self-acting voltage compensation feature from the passive SFCL and an intelligent reactive power compensation feature from the active TVC. Simulation results show that the cooperative control of the SFCL and TVC can achieve high stator voltage level and high output reactive power for efficient grid connection and voltage support.
- 30 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (7) , 1-6
Cooperative Control of SFCL and Reactive Power for Improving the Transient Voltage Stability of Grid-Connected Wind Farm With DFIGs
This paper studies transient voltage stability in a 9-MW doubly-fed-induction-generator-based wind farm integrated with one superconducting fault current limiter (SFCL)-based passive voltage compensator and one transient voltage control (TVC)-based active voltage compensator. To achieve effective control manner, basic cooperative operation and modeling of the two voltage compensators are described. In addition, a technical discussion on the designs of proportional-integral parameters of the TVC and SFCL resistance are conducted. The effectively integrated system is highlighted with a self-acting voltage compensation feature from the passive SFCL and an intelligent reactive power compensation feature from the active TVC. Simulation results show that the cooperative control of the SFCL and TVC can achieve high stator voltage level and high output reactive power for efficient grid connection and voltage support.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 240-241
Application of SFCL to improve the transient voltage stability of grid-connected wind farm with DFIG during grid faults
A novel superconducting fault current limiter (SFCL) based transient voltage stability scheme is presented for use in wind farms driven by doubly-fed induction generator (DFIG) during grid faults. The proposed scheme consists of active and passive self-acting voltage compensators. The active compensator is carried out by allocating the reactive power references between the stator and the grid side converter automatically. The passive compensator utilizes a SFCL to improve the reduced stator voltage, which in turn considerably improves the controller performance of the active voltage compensator. Simulation results verify that both the output reactive power for grid voltage support and the stator voltage level for efficient grid-connection strictly satisfy with the grid code requirements.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 240-241
Application of SFCL to improve the transient voltage stability of grid-connected wind farm with DFIG during grid faults
A novel superconducting fault current limiter (SFCL) based transient voltage stability scheme is presented for use in wind farms driven by doubly-fed induction generator (DFIG) during grid faults. The proposed scheme consists of active and passive self-acting voltage compensators. The active compensator is carried out by allocating the reactive power references between the stator and the grid side converter automatically. The passive compensator utilizes a SFCL to improve the reduced stator voltage, which in turn considerably improves the controller performance of the active voltage compensator. Simulation results verify that both the output reactive power for grid voltage support and the stator voltage level for efficient grid-connection strictly satisfy with the grid code requirements.