Víctor-Manuel Soto-Francés
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Víctor-Manuel Soto-Francés has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Emilio José Sarabia Escriva
Universitat Politècnica de València
7 shared publications José Manuel Pinazo Ojer
6 shared publications- José-Manuel Pinazo-Ojer
Universitat Politècnica de València (Edif. 5J), Camino de Vera, s/n, Valencia, 46022, Spain
5 shared publications - Pedro Juan Martinez
Department of Mechanical Engineering and Energy, Miguel Hernández University, Avda. Universidad, s/n-Ed. Innova, 03202 Elche, Spain
5 shared publications - Emilio-José Sarabia-Escrivá
ETSII, Universitat Politècnica de València
2 shared publications - Jose Manuel Pinazo Ojer
ETSII, Universitat Politècnica de València
2 shared publications
Latest Publications
- Open Access
- 18 July 2024
- Published by Universidad Miguel Hernandez de Elche in Avances en Ciencias y Técnicas del Frío - 12. Actas del XII Congreso Ibérico y X Congreso Iberoamericano de Ciencias y Técnicas del Frío CYTEF 2024
IMPACT OF THE CLIMATE CHANGE ON THE ENERGY CERTIFICATION OF A MULTI-FAMILIY BUILDING IN VALENCIA
: The European EPBD directive initially emerged as a way to label buildings to inform the consumer. At that time, it sought to compare its performance with other products, such as a washing machine. However, the climatic, economic-social, and energy context is forcing the evaluation of the actual energy performance with pecuniary links. This article compares the actual Valencia weather in 1992, 2002, 2012, 2022, and 2023 with the official one used by the Spanish certification scheme. An old, existing multi-family building is rehabilitated to get a label A. Additionally, it meets the restrictions of the current CTE-HE. The paper assesses the impact of considering the actual weather on their energy performance in both states, before and after rehabilitation, as well as on their energy rating, and discusses the outcomes. All computations have been performed with the recognized software tool CERMA.
- 18 July 2024
- Published by Universidad Miguel Hernandez de Elche in Avances en Ciencias y Técnicas del Frío - 12. Actas del XII Congreso Ibérico y X Congreso Iberoamericano de Ciencias y Técnicas del Frío CYTEF 2024
Open AccessIMPACT OF THE CLIMATE CHANGE ON THE ENERGY CERTIFICATION OF A MULTI-FAMILIY BUILDING IN VALENCIA
: The European EPBD directive initially emerged as a way to label buildings to inform the consumer. At that time, it sought to compare its performance with other products, such as a washing machine. However, the climatic, economic-social, and energy context is forcing the evaluation of the actual energy performance with pecuniary links. This article compares the actual Valencia weather in 1992, 2002, 2012, 2022, and 2023 with the official one used by the Spanish certification scheme. An old, existing multi-family building is rehabilitated to get a label A. Additionally, it meets the restrictions of the current CTE-HE. The paper assesses the impact of considering the actual weather on their energy performance in both states, before and after rehabilitation, as well as on their energy rating, and discusses the outcomes. All computations have been performed with the recognized software tool CERMA.
- Open Access
- 15 March 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 69
Multi-layered slab 1D conduction heat transfer for buildings discrete event simulations
- 15 March 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 69
Open AccessMulti-layered slab 1D conduction heat transfer for buildings discrete event simulations
- 22 February 2023
- Published by Elsevier in Energy and Buildings
- Vol. 286
Economic and environmental analysis of domestic hot water systems for single-family homes
- 22 February 2023
- Published by Elsevier in Energy and Buildings
- Vol. 286
Economic and environmental analysis of domestic hot water systems for single-family homes
- 26 July 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (9) , 1255-1269
Mathematical model based on the radiosity method for estimating the efficiency of in-duct UVGI systems
The article describes a model for calculating the killing ratio of different pathogens with an in-duct ultraviolet (UV) device. The model is based on the radiosity method adapted for the UV radiation range and can be used for analysing any lamp distribution. The paper provides the necessary view factors and the influence of environmental variables (temperature, humidity and air velocity) in the analysis. The model has been validated using the results of four commercial equipment certificates issued by the US Environmental Protection Agency (EPA). The model results show a high precision on the test results, with a maximum deviation of 9%. In all cases, the model results are lower than that of the test, which allows being on the side of safety in the design. The model has been programmed in software used by Steril-Air for designing its equipment. Finally, an example of calculating the SARS-CoV-2 killing ratio with a 4x2 lamps arrangement is shown.
- 26 July 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (9) , 1255-1269
Mathematical model based on the radiosity method for estimating the efficiency of in-duct UVGI systems
The article describes a model for calculating the killing ratio of different pathogens with an in-duct ultraviolet (UV) device. The model is based on the radiosity method adapted for the UV radiation range and can be used for analysing any lamp distribution. The paper provides the necessary view factors and the influence of environmental variables (temperature, humidity and air velocity) in the analysis. The model has been validated using the results of four commercial equipment certificates issued by the US Environmental Protection Agency (EPA). The model results show a high precision on the test results, with a maximum deviation of 9%. In all cases, the model results are lower than that of the test, which allows being on the side of safety in the design. The model has been programmed in software used by Steril-Air for designing its equipment. Finally, an example of calculating the SARS-CoV-2 killing ratio with a 4x2 lamps arrangement is shown.
- Open Access
Conventional and Advanced Exergoeconomic Analysis of a Compound Ejector-Heat Pump for Simultaneous Cooling and Heating
This work focused on a compound PV/T waste heat driven ejector-heat pump system for simultaneous data centre cooling and waste heat recovery for district heating. The system uses PV/T waste heat as the generator’s heat source, acting with the vapour generated in an evaporative condenser as the ejector drive force. Conventional and advanced exergy and advanced exergoeconomic analyses are used to determine the cause and avoidable degree of the components’ exergy destruction rate and cost rates. Regarding the conventional exergy analysis for the whole system, the compressor represents the largest exergy destruction source of 26%. On the other hand, the generator shows the lowest sources (2%). The advanced exergy analysis indicates that 59.4% of the whole system thermodynamical inefficiencies can be avoided by further design optimisation. The compressor has the highest contribution to the destruction in the avoidable exergy destruction rate (21%), followed by the ejector (18%) and condenser (8%). Moreover, the advanced exergoeconomic results prove that 51% of the system costs are unavoidable. In system components cost comparison, the highest cost comes from the condenser, 30%. In the same context, the ejector has the lowest exergoeconomic factor, and it should be getting more attention to reduce the irreversibility by design improving. On the contrary, the evaporator has the highest exergoeconomic factor (94%).
Open AccessConventional and Advanced Exergoeconomic Analysis of a Compound Ejector-Heat Pump for Simultaneous Cooling and Heating
This work focused on a compound PV/T waste heat driven ejector-heat pump system for simultaneous data centre cooling and waste heat recovery for district heating. The system uses PV/T waste heat as the generator’s heat source, acting with the vapour generated in an evaporative condenser as the ejector drive force. Conventional and advanced exergy and advanced exergoeconomic analyses are used to determine the cause and avoidable degree of the components’ exergy destruction rate and cost rates. Regarding the conventional exergy analysis for the whole system, the compressor represents the largest exergy destruction source of 26%. On the other hand, the generator shows the lowest sources (2%). The advanced exergy analysis indicates that 59.4% of the whole system thermodynamical inefficiencies can be avoided by further design optimisation. The compressor has the highest contribution to the destruction in the avoidable exergy destruction rate (21%), followed by the ejector (18%) and condenser (8%). Moreover, the advanced exergoeconomic results prove that 51% of the system costs are unavoidable. In system components cost comparison, the highest cost comes from the condenser, 30%. In the same context, the ejector has the lowest exergoeconomic factor, and it should be getting more attention to reduce the irreversibility by design improving. On the contrary, the evaporator has the highest exergoeconomic factor (94%).
- Open Access
Analysis of the Performance of a Passive Downdraught Evaporative Cooling System Driven by Solar Chimneys in a Residential Building by Using an Experimentally Validated TRNSYS Model
Natural ventilation, combined with a passive cooling system, can provide significant energy savings in the refrigeration of indoor spaces. The performance of these systems is highly dependent on outdoor climatic conditions. The objective of this study was to analyse the feasibility of a passive, downdraught, evaporative cooling system driven by solar chimneys in different climatic zones by using an experimentally validated simulation tool. This tool combined a ventilation model and a thermal model of the dwelling in which an empirical model of a direct evaporative system made of plastic mesh was implemented. For experimental validation of the combined model, sensors were installed in the dwelling and calibrated in the laboratory. The combined model was applied to Spanish and European cities with different climates. In the simulation, values of cooling energy per volume of air ranging between 0.53 Wh/m3 and 0.79 Wh/m3 were obtained for Alicante (hot climate with moderate humidity) and Madrid (hot and dry climate), respectively. In these locations, medium and high applicability was obtained, respectively, in comparison with Burgos (cold climate with moderate humidity) and Bilbao (cold and humid climate), which were low. The evaluation of the reference building in each location allowed establishing a classification in terms of performance, comfort and applicability for each climate.
Open AccessAnalysis of the Performance of a Passive Downdraught Evaporative Cooling System Driven by Solar Chimneys in a Residential Building by Using an Experimentally Validated TRNSYS Model
Natural ventilation, combined with a passive cooling system, can provide significant energy savings in the refrigeration of indoor spaces. The performance of these systems is highly dependent on outdoor climatic conditions. The objective of this study was to analyse the feasibility of a passive, downdraught, evaporative cooling system driven by solar chimneys in different climatic zones by using an experimentally validated simulation tool. This tool combined a ventilation model and a thermal model of the dwelling in which an empirical model of a direct evaporative system made of plastic mesh was implemented. For experimental validation of the combined model, sensors were installed in the dwelling and calibrated in the laboratory. The combined model was applied to Spanish and European cities with different climates. In the simulation, values of cooling energy per volume of air ranging between 0.53 Wh/m3 and 0.79 Wh/m3 were obtained for Alicante (hot climate with moderate humidity) and Madrid (hot and dry climate), respectively. In these locations, medium and high applicability was obtained, respectively, in comparison with Burgos (cold climate with moderate humidity) and Bilbao (cold and humid climate), which were low. The evaluation of the reference building in each location allowed establishing a classification in terms of performance, comfort and applicability for each climate.
- 6 February 2020
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 13 (3) , 247-263
Exploring the use of traditional heat transfer functions for energy simulation of buildings using discrete events and quantized-state-based integration
The target of the paper is to study how to devise an efficient discrete-event model for the yearly energy simulation of buildings. Conventionally, software tools use time-driven schemes and many components must be computed at every sampling time-point. Event-driven simulation aims at lowering this burden, by calling only those components whose state is evolving quickly. The article explores a model based on DEVS formalism and Quantized State Systems (QSS) techniques. Within this paradigm shift, our strategy was to reuse as much widely accepted knowledge as possible. One immediate difficulty was, that the well-known conduction heat transfer function (CHTF) of multi-layered walls is not suitable for DEVS in its traditional form since it is constrained to sample at a fixed time step. Instead, the paper introduces a non-conventional method: the Successive State Transition method (SST). Its distinguishing traits are: it allows variable time steps, has high accuracy and its computational workload adapts to the elapsed time between transitions. Unfortunately, although we found that SST and QSS work well together, the paper shows that the aforementioned transfer function is not adequate for event-driven simulations. Based on the paper outcomes, we propose a workaround for further research: a new transfer function, relating the conduction heat flux (input) to the time derivative of the wall superficial temperature (output) (recall that the traditional input-output relationship: superficial temperature and conduction heat flux, respectively). Abbreviations: CHTF: Conduction Heat Transfer Functions; DEVS: Discrete Event Simulation; DRFM: Direct Root Finding methods; SST: Successive State Transitionmethod; QSS: Quantized State System
- 6 February 2020
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 13 (3) , 247-263
Exploring the use of traditional heat transfer functions for energy simulation of buildings using discrete events and quantized-state-based integration
The target of the paper is to study how to devise an efficient discrete-event model for the yearly energy simulation of buildings. Conventionally, software tools use time-driven schemes and many components must be computed at every sampling time-point. Event-driven simulation aims at lowering this burden, by calling only those components whose state is evolving quickly. The article explores a model based on DEVS formalism and Quantized State Systems (QSS) techniques. Within this paradigm shift, our strategy was to reuse as much widely accepted knowledge as possible. One immediate difficulty was, that the well-known conduction heat transfer function (CHTF) of multi-layered walls is not suitable for DEVS in its traditional form since it is constrained to sample at a fixed time step. Instead, the paper introduces a non-conventional method: the Successive State Transition method (SST). Its distinguishing traits are: it allows variable time steps, has high accuracy and its computational workload adapts to the elapsed time between transitions. Unfortunately, although we found that SST and QSS work well together, the paper shows that the aforementioned transfer function is not adequate for event-driven simulations. Based on the paper outcomes, we propose a workaround for further research: a new transfer function, relating the conduction heat flux (input) to the time derivative of the wall superficial temperature (output) (recall that the traditional input-output relationship: superficial temperature and conduction heat flux, respectively). Abbreviations: CHTF: Conduction Heat Transfer Functions; DEVS: Discrete Event Simulation; DRFM: Direct Root Finding methods; SST: Successive State Transitionmethod; QSS: Quantized State System
- Open Access
- 9 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 496
Design of a 35 kW Solar Cooling Demonstration Facility for a Hotel in Spain
Solar cooling systems have the advantage of the coincidence between the hours of cooling demand and the hours of solar radiation availability, and they can contribute to reduce the energy consumption in buildings. However, the high cost of thermal solar cooling facilities with absorption chillers, maintenance issues, legionella risk and water consumption (associated to the necessary cooling tower) have limited the use of these systems to demonstration projects. A simplified Transient System Simulation Tool (TRNSYS) model was developed to provide the owner of the demonstration facility the information he needs for design decision-making. This model was validated with experimental data registered in a solar cooling system designed and built by the authors. Different collector field surfaces, hot water storage tank volumes, and absorption machine driving temperatures were analyzed for a hotel demonstration facility. In terms of the energy delivered to the absorption chiller the optimum dimensioning corresponded to the lowest values of the driving temperature (75 °C) and specific storage volume (15 Lm2). From an economic point of view, the saving of 1515 euros per year when compared with an electric compression chiller does not compensate the investment of 3000 euros per kW of cooling capacity that cost the thermal solar cooling facility.
- 9 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 496
Open AccessDesign of a 35 kW Solar Cooling Demonstration Facility for a Hotel in Spain
Solar cooling systems have the advantage of the coincidence between the hours of cooling demand and the hours of solar radiation availability, and they can contribute to reduce the energy consumption in buildings. However, the high cost of thermal solar cooling facilities with absorption chillers, maintenance issues, legionella risk and water consumption (associated to the necessary cooling tower) have limited the use of these systems to demonstration projects. A simplified Transient System Simulation Tool (TRNSYS) model was developed to provide the owner of the demonstration facility the information he needs for design decision-making. This model was validated with experimental data registered in a solar cooling system designed and built by the authors. Different collector field surfaces, hot water storage tank volumes, and absorption machine driving temperatures were analyzed for a hotel demonstration facility. In terms of the energy delivered to the absorption chiller the optimum dimensioning corresponded to the lowest values of the driving temperature (75 °C) and specific storage volume (15 Lm2). From an economic point of view, the saving of 1515 euros per year when compared with an electric compression chiller does not compensate the investment of 3000 euros per kW of cooling capacity that cost the thermal solar cooling facility.
- Open Access
- 16 December 2019
- Published by Universitat Politecnica de Valencia
Desarrollo de una aplicación docente para cálculos de refrigeración y aplicación en sesiones prácticas
El artículo presenta el desarrollo de una aplicación de carácter docente para la impartición de clases de refrigeración. Se analizan las características que requiere el software y cómo éste se implementa en las sesiones de teoría y de prácticas informáticas. Al ser una aplicación informática de acceso libre, cualquier alumno puede descargársela en su ordenador para poder trabajar con ella. El desarrollo de la aplicación permite al docente tener una herramienta visual para las explicaciones teóricas y diseñar actividades de análisis, sin que el alumno tenga que centrar tanto la atención en los cálculos.
- 16 December 2019
- Published by Universitat Politecnica de Valencia
Open AccessDesarrollo de una aplicación docente para cálculos de refrigeración y aplicación en sesiones prácticas
El artículo presenta el desarrollo de una aplicación de carácter docente para la impartición de clases de refrigeración. Se analizan las características que requiere el software y cómo éste se implementa en las sesiones de teoría y de prácticas informáticas. Al ser una aplicación informática de acceso libre, cualquier alumno puede descargársela en su ordenador para poder trabajar con ella. El desarrollo de la aplicación permite al docente tener una herramienta visual para las explicaciones teóricas y diseñar actividades de análisis, sin que el alumno tenga que centrar tanto la atención en los cálculos.
- 1 November 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 107, 288-300
Modelling of a real CO2 booster installation and evaluation of control strategies for heat recovery applications in supermarkets
- 1 November 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 107, 288-300
Modelling of a real CO2 booster installation and evaluation of control strategies for heat recovery applications in supermarkets