Fabrizio Nardini
Research Subjects
Fabrizio Nardini has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Leardini
Movement Analysis Laboratory and Functional Evaluation of Prostheses, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
3 shared publications - Claudio Belvedere
Movement Analysis Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
3 shared publications - Nicola Sancisi
Department of Industrial Engineering, University of Bologna, Bologna, Italy
3 shared publications - Vincenzo Parenti-Castelli
DIN-Department of Industrial Engineering, University of Bologna, Bologna, Italy
3 shared publications Nicola Sancisi
DIN-Department of Industrial Engineering, Health Sciences and Technologies, Interdepartmental Centre for Industrial Research (HST-ICIR), Università degli Studi di Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy
2 shared publicationsVincenzo Parenti-Castelli
DIN-Department of Industrial Engineering, Health Sciences and Technologies, Interdepartmental Centre for Industrial Research (HST-ICIR), Università degli Studi di Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy
2 shared publications
Latest Publications
- Open Access
- 22 April 2023
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 3 (3) , 303-311
Accuracy of measuring scapular position and motion with a novel motion capture system
- 22 April 2023
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 3 (3) , 303-311
Open AccessAccuracy of measuring scapular position and motion with a novel motion capture system
- Open Access
- 28 June 2022
- Published by Springer Nature in Multibody System Dynamics
- Vol. 55 (4) , 433-451
A fast ligament model with scalable accuracy for multibody simulations
Multibody musculoskeletal models are important tools to perform kinematic, kinetostatic, and dynamic analyses of the whole human body. In these models, bones are regarded as rigid bodies, while different strategies are used to model structures such as muscles and ligaments. In this context, ligaments are often represented using a finite set of spring-like elements to compute the wrench applied to the bones (multibundle model). While this model is fast and easy to be implemented, it can suffer from inaccuracies due to the limited number of fibers and their positioning. In this study, a ligament model is proposed to overcome these limitations, representing the ligament as an infinite distribution of fibers from which the wrench on the bones can be obtained. The model takes advantage of thin-plate spline mapping to model the fiber structure of the ligament by defining a correspondence between the points of the two ligament insertions. The accuracy and the performances of the model are verified on a ligament and compared to the standard multibundle model. Results indicate that the model is faster and more accurate than the multibundle model. Moreover, accuracy can be modified according to the application in order to decrease the computational time.
- 28 June 2022
- Published by Springer Nature in Multibody System Dynamics
- Vol. 55 (4) , 433-451
Open AccessA fast ligament model with scalable accuracy for multibody simulations
Multibody musculoskeletal models are important tools to perform kinematic, kinetostatic, and dynamic analyses of the whole human body. In these models, bones are regarded as rigid bodies, while different strategies are used to model structures such as muscles and ligaments. In this context, ligaments are often represented using a finite set of spring-like elements to compute the wrench applied to the bones (multibundle model). While this model is fast and easy to be implemented, it can suffer from inaccuracies due to the limited number of fibers and their positioning. In this study, a ligament model is proposed to overcome these limitations, representing the ligament as an infinite distribution of fibers from which the wrench on the bones can be obtained. The model takes advantage of thin-plate spline mapping to model the fiber structure of the ligament by defining a correspondence between the points of the two ligament insertions. The accuracy and the performances of the model are verified on a ligament and compared to the standard multibundle model. Results indicate that the model is faster and more accurate than the multibundle model. Moreover, accuracy can be modified according to the application in order to decrease the computational time.
- Open Access
- 20 March 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (6) , 2100
An Anatomical-Based Subject-Specific Model of In-Vivo Knee Joint 3D Kinematics From Medical Imaging
Biomechanical models of the knee joint allow the development of accurate procedures as well as novel devices to restore the joint natural motion. They are also used within musculoskeletal models to perform clinical gait analysis on patients. Among relevant knee models in the literature, the anatomy-based spatial parallel mechanisms represent the joint motion using rigid links for the ligaments’ isometric fibres and point contacts for the articular surfaces. To customize analyses, therapies and devices, there is the need to define subject-specific models, but relevant procedures and their accuracy are still questioned. A procedure is here proposed and validated to define a customized knee model based on a spatial parallel mechanism. Computed tomography, magnetic resonance and 3D-video-fluoroscopy were performed on a healthy volunteer to define the personalized model geometry. The model was then validated by comparing the measured and the replicated joint motion. The model showed mean absolute difference and standard deviations in translations and rotations, respectively of mm and for the tibia–femur motion, and of mm and for the patella–femur motion. These results show that accurate personalized spatial models of knee kinematics can be obtained from in-vivo imaging.- 20 March 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (6) , 2100
Open AccessAn Anatomical-Based Subject-Specific Model of In-Vivo Knee Joint 3D Kinematics From Medical Imaging
Biomechanical models of the knee joint allow the development of accurate procedures as well as novel devices to restore the joint natural motion. They are also used within musculoskeletal models to perform clinical gait analysis on patients. Among relevant knee models in the literature, the anatomy-based spatial parallel mechanisms represent the joint motion using rigid links for the ligaments’ isometric fibres and point contacts for the articular surfaces. To customize analyses, therapies and devices, there is the need to define subject-specific models, but relevant procedures and their accuracy are still questioned. A procedure is here proposed and validated to define a customized knee model based on a spatial parallel mechanism. Computed tomography, magnetic resonance and 3D-video-fluoroscopy were performed on a healthy volunteer to define the personalized model geometry. The model was then validated by comparing the measured and the replicated joint motion. The model showed mean absolute difference and standard deviations in translations and rotations, respectively of mm and for the tibia–femur motion, and of mm and for the patella–femur motion. These results show that accurate personalized spatial models of knee kinematics can be obtained from in-vivo imaging. - 23 June 2018
- Published by Springer Nature
- p. 327-334
A Ligament Model Based on Fibre Mapping for Multibody Simulations
- 23 June 2018
- Published by Springer Nature
- p. 327-334
A Ligament Model Based on Fibre Mapping for Multibody Simulations
- 1 September 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 62, 77-86
Kinematic models of lower limb joints for musculo-skeletal modelling and optimization in gait analysis
- 1 September 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 62, 77-86
Kinematic models of lower limb joints for musculo-skeletal modelling and optimization in gait analysis
- 9 April 2015
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 15 (02)
VARIATION OF THE ANKLE MOTION WITH THE PIVOT-POINT POSITION AS PREDICTED BY A SPHERICAL MODEL OF THE JOINT
Recent studies proved that the ankle unloaded motion is nearly spherical and can be accurately modeled by one degree-of-freedom spatial spherical mechanisms. Starting from relevant experimental data measured on nine specimens, the global optimal pivot-point (PP) position, i.e., the center of this spherical motion, is obtained in this study and the effect on ankle motion of the changing position of this PP is analyzed.
- 9 April 2015
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 15 (02)
VARIATION OF THE ANKLE MOTION WITH THE PIVOT-POINT POSITION AS PREDICTED BY A SPHERICAL MODEL OF THE JOINT
Recent studies proved that the ankle unloaded motion is nearly spherical and can be accurately modeled by one degree-of-freedom spatial spherical mechanisms. Starting from relevant experimental data measured on nine specimens, the global optimal pivot-point (PP) position, i.e., the center of this spherical motion, is obtained in this study and the effect on ankle motion of the changing position of this PP is analyzed.