Myoung Joon Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Myoung Joon Kim has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Hungwon Tchah
Department of Ophthalmology, Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
8 shared publicationsSeunghun Lee
Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, Republic of Korea
5 shared publicationsJae Yong Kim
3 shared publications- Jin Hyoung Park
MS Eye Clinic, Seoul 06512, Republic of Korea
3 shared publications - Ki Hean Kim
Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, Republic of Korea
3 shared publications In Seok Song
Department of Ophthalmology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
2 shared publications
Latest Publications
- 23 July 2019
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 52 (4) , 373-382
Moxifloxacin Labeling‐Based Multiphoton Microscopy of Skin Cancers in Asians
Background and Objectives: Although multiphoton microscopy (MPM) can visualize both cell and extracellular matrix (ECM) structures of the skin in high‐contrast without exogenous labeling, label‐free MPM is usually too slow to image clinically relevant large regions. A high‐speed MPM method would be beneficial for evaluating clinical skin specimens by increasing the imaging area. In this study, moxifloxacin labeling‐based MPM (moxifloxacin MPM) was characterized in various human skin cancer specimens.Study Design/Materials and Methods: Moxifloxacin ophthalmic solution was used for cell‐labeling and MPM imaging was conducted afterwards. Moxifloxacin MPM was characterized in ex vivo normal human skin and skin cancer specimens in comparison with the label‐free MPM and fluorescence confocal microscopy (FCM) using acridine orange as a labeling agent. Then, moxifloxacin MPM was applied to various ex vivo human skin cancer specimens including basal cell carcinoma (BCC), squamous cell carcinoma (SCC), dermatofibrosarcoma protuberans (DFSP). Results of moxifloxacin MPM were compared with bright‐field clinical and histopathologic findings.Results: Moxifloxacin MPM imaged both cells and collagen in the skin, similarly to label‐free MPM, but with enhanced fluorescence intensities in cells and enhanced imaging speeds. Moxifloxacin MPM imaged cells in the skin similarly to acridine orange‐based FCM. Moxifloxacin MPM of various human skin cancer specimens imaged their specific cellular features. The microscopic features detected in moxifloxacin MPM were confirmed with histological images.Conclusions: This observational pilot study demonstrated that moxifloxacin MPM could detect specific cellular features of various skin cancers in good correlation with histopathological images in Asian patients at the higher imaging speed than label‐free MPM. Lasers Surg. Med.
- 23 July 2019
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 52 (4) , 373-382
Moxifloxacin Labeling‐Based Multiphoton Microscopy of Skin Cancers in Asians
Background and Objectives: Although multiphoton microscopy (MPM) can visualize both cell and extracellular matrix (ECM) structures of the skin in high‐contrast without exogenous labeling, label‐free MPM is usually too slow to image clinically relevant large regions. A high‐speed MPM method would be beneficial for evaluating clinical skin specimens by increasing the imaging area. In this study, moxifloxacin labeling‐based MPM (moxifloxacin MPM) was characterized in various human skin cancer specimens.Study Design/Materials and Methods: Moxifloxacin ophthalmic solution was used for cell‐labeling and MPM imaging was conducted afterwards. Moxifloxacin MPM was characterized in ex vivo normal human skin and skin cancer specimens in comparison with the label‐free MPM and fluorescence confocal microscopy (FCM) using acridine orange as a labeling agent. Then, moxifloxacin MPM was applied to various ex vivo human skin cancer specimens including basal cell carcinoma (BCC), squamous cell carcinoma (SCC), dermatofibrosarcoma protuberans (DFSP). Results of moxifloxacin MPM were compared with bright‐field clinical and histopathologic findings.Results: Moxifloxacin MPM imaged both cells and collagen in the skin, similarly to label‐free MPM, but with enhanced fluorescence intensities in cells and enhanced imaging speeds. Moxifloxacin MPM imaged cells in the skin similarly to acridine orange‐based FCM. Moxifloxacin MPM of various human skin cancer specimens imaged their specific cellular features. The microscopic features detected in moxifloxacin MPM were confirmed with histological images.Conclusions: This observational pilot study demonstrated that moxifloxacin MPM could detect specific cellular features of various skin cancers in good correlation with histopathological images in Asian patients at the higher imaging speed than label‐free MPM. Lasers Surg. Med.
- 1 September 2018
- Published by Elsevier in Experimental Eye Research
- Vol. 174, 51-58
Two-photon microscopy of fungal keratitis-affected rabbit cornea ex vivo using moxifloxacin as a labeling agent
- 1 September 2018
- Published by Elsevier in Experimental Eye Research
- Vol. 174, 51-58
Two-photon microscopy of fungal keratitis-affected rabbit cornea ex vivo using moxifloxacin as a labeling agent
- Open Access
- 3 May 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 25339
In vivo 3D measurement of moxifloxacin and gatifloxacin distributions in the mouse cornea using multiphoton microscopy
Moxifloxacin and gatifloxacin are fourth-generation fluoroquinolone antibiotics used in the clinic to prevent or treat ocular infections. Their pharmacokinetics in the cornea is usually measured from extracted ocular fluids or tissues, and in vivo direct measurement is difficult. In this study multiphoton microscopy (MPM), which is a 3D optical microscopic technique based on multiphoton fluorescence, was applied to the measurement of moxifloxacin and gatifloxacin distribution in the cornea. Intrinsic multiphoton fluorescence properties of moxifloxacin and gatifloxacin were characterized, and their distributions in mouse cornea in vivo were measured by 3D MPM imaging. Both moxifloxacin and gatifloxacin had similar multiphoton spectra, while moxifloxacin had stronger fluorescence than gatifloxacin. MPM imaging of mouse cornea in vivo showed (1) moxifloxacin had good penetration through the superficial corneal epithelium, while gatifloxacin had relatively poor penetration, (2) both ophthalmic solutions had high intracellular distribution. In vivo MPM results were consistent with previous studies. This study demonstrates the feasibility of MPM as a method for in vivo direct measurement of moxifloxacin and gatifloxacin in the cornea.
- 3 May 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 25339
Open AccessIn vivo 3D measurement of moxifloxacin and gatifloxacin distributions in the mouse cornea using multiphoton microscopy
Moxifloxacin and gatifloxacin are fourth-generation fluoroquinolone antibiotics used in the clinic to prevent or treat ocular infections. Their pharmacokinetics in the cornea is usually measured from extracted ocular fluids or tissues, and in vivo direct measurement is difficult. In this study multiphoton microscopy (MPM), which is a 3D optical microscopic technique based on multiphoton fluorescence, was applied to the measurement of moxifloxacin and gatifloxacin distribution in the cornea. Intrinsic multiphoton fluorescence properties of moxifloxacin and gatifloxacin were characterized, and their distributions in mouse cornea in vivo were measured by 3D MPM imaging. Both moxifloxacin and gatifloxacin had similar multiphoton spectra, while moxifloxacin had stronger fluorescence than gatifloxacin. MPM imaging of mouse cornea in vivo showed (1) moxifloxacin had good penetration through the superficial corneal epithelium, while gatifloxacin had relatively poor penetration, (2) both ophthalmic solutions had high intracellular distribution. In vivo MPM results were consistent with previous studies. This study demonstrates the feasibility of MPM as a method for in vivo direct measurement of moxifloxacin and gatifloxacin in the cornea.
- Open Access
- 26 January 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (2) , 677-687
Comparison of reflectance confocal microscopy and two-photon second harmonic generation microscopy in fungal keratitis rabbit model ex vivo
Fungal keratitis is an infection of the cornea by fungal pathogens. Diagnosis methods based on optical microscopy could be beneficial over the conventional microbiology method by allowing rapid and non-invasive examination. Reflectance confocal microscopy (RCM) and two-photon second harmonic generation microscopy (TPSHGM) have been applied to pre-clinical or clinical studies of fungal keratitis. In this report, RCM and TPSHGM were characterized and compared in the imaging of a fungal keratitis rabbit model ex vivo. Fungal infection was induced by using two strains of fungi: aspergillus fumigatus and candida albicans. The infected corneas were imaged in fresh condition by both modalities sequentially and their images were analyzed. Both RCM and TPSHGM could detect both fungal strains within the cornea based on morphology: aspergillus fumigatus had distinctive filamentous structures, and candida albicans had round structures superficially and elongated structures in the corneal stroma. These imaging results were confirmed by histology. Comparison between RCM and TPSHGM showed several characteristics. Although RCM and TPSHGM images had good correlation each other, their images were slightly different due to difference in contrast mechanism. RCM had relatively low image contrast with the infected turbid corneas due to high background signal. TPSHGM visualized cells and collagen in the cornea clearly compared to RCM, but used higher laser power to compensate low autofluorescence. Since these two modalities provide complementary information, combination of RCM and TPSHGM would be useful for fungal keratitis detection by compensating their weaknesses each other.
- 26 January 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (2) , 677-687
Open AccessComparison of reflectance confocal microscopy and two-photon second harmonic generation microscopy in fungal keratitis rabbit model ex vivo
Fungal keratitis is an infection of the cornea by fungal pathogens. Diagnosis methods based on optical microscopy could be beneficial over the conventional microbiology method by allowing rapid and non-invasive examination. Reflectance confocal microscopy (RCM) and two-photon second harmonic generation microscopy (TPSHGM) have been applied to pre-clinical or clinical studies of fungal keratitis. In this report, RCM and TPSHGM were characterized and compared in the imaging of a fungal keratitis rabbit model ex vivo. Fungal infection was induced by using two strains of fungi: aspergillus fumigatus and candida albicans. The infected corneas were imaged in fresh condition by both modalities sequentially and their images were analyzed. Both RCM and TPSHGM could detect both fungal strains within the cornea based on morphology: aspergillus fumigatus had distinctive filamentous structures, and candida albicans had round structures superficially and elongated structures in the corneal stroma. These imaging results were confirmed by histology. Comparison between RCM and TPSHGM showed several characteristics. Although RCM and TPSHGM images had good correlation each other, their images were slightly different due to difference in contrast mechanism. RCM had relatively low image contrast with the infected turbid corneas due to high background signal. TPSHGM visualized cells and collagen in the cornea clearly compared to RCM, but used higher laser power to compensate low autofluorescence. Since these two modalities provide complementary information, combination of RCM and TPSHGM would be useful for fungal keratitis detection by compensating their weaknesses each other.
- 1 March 2015
- Published by Elsevier in Experimental Eye Research
- Vol. 132, 101-108
Comparison of confocal microscopy and two-photon microscopy in mouse cornea in vivo
- 1 March 2015
- Published by Elsevier in Experimental Eye Research
- Vol. 132, 101-108
Comparison of confocal microscopy and two-photon microscopy in mouse cornea in vivo
- 1 July 2014
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 30 (7) , 442-446
Higher-Order Aberrations Associated With Better Near Visual Acuity in Eyes With Aspheric Monofocal IOLs
PURPOSE: To investigate higher-order aberrations (HOAs) related to increased uncorrected near visual acuity in eyes with aspheric monofocal intraocular lenses. METHODS: All patients underwent phacoemulsifica-tion followed by implantation of aspheric monofocal intraocular lenses with a negative spherical aberration (Tecnis one-piece, ZCB00; Abbott Medical Optics, Inc., Milpitas, CA). The distance-corrected near visual acuity (DCNVA), corrected near visual acuity, uncorrected near visual acuity, corrected distance visual acuity, uncorrected distance visual acuity, defocus curve, and ocular and corneal HOAs were examined 1 month after surgery. All near visual acuity measurements were taken with a 4-mm external aperture after pharmacologic dilation. Eyes were divided into two groups according to the DCNVA: eyes with DCNVA of 0.4 logMAR (20/50 Snellen) or better (0.4 logMAR or better group) and eyes with DCNVA worse than 0.4 logMAR (0.4 logMAR or worse group). The HOAs for a 4-mm pupil between the two groups were compared. RESULTS: A total of 37 eyes of 36 patients were included. The mean ocular spherical aberration was −0.010 ± 0.033 μ m in the 0.4 logMAR or better group and −0.012 ± 0.023 μ m in the 0.4 logMAR or worse group ( P = .28). Among ocular HOAs, only vertical coma Z 3 −1 showed a significant difference between the groups, with a mean ocular vertical coma of −0.038 ± 0.043 μ m in the 0.4 logMAR or better group and 0.015 ± 0.061 μ m in the 0.4 logMAR or worse group ( P = .01). In corneal HOAs, no components showed a significant difference between the groups. CONCLUSIONS: In cases of aspheric intraocular lens implantation, ocular vertical coma may be a major HOA associated with better near visual acuity. Although corneal aberrations are major determinants of ocular aberrations after cataract surgery, aberrations from internal optics may still play an important role in visual performance. [ J Refract Surg. 2014;30(7):442–446.]
- 1 July 2014
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 30 (7) , 442-446
Higher-Order Aberrations Associated With Better Near Visual Acuity in Eyes With Aspheric Monofocal IOLs
PURPOSE: To investigate higher-order aberrations (HOAs) related to increased uncorrected near visual acuity in eyes with aspheric monofocal intraocular lenses. METHODS: All patients underwent phacoemulsifica-tion followed by implantation of aspheric monofocal intraocular lenses with a negative spherical aberration (Tecnis one-piece, ZCB00; Abbott Medical Optics, Inc., Milpitas, CA). The distance-corrected near visual acuity (DCNVA), corrected near visual acuity, uncorrected near visual acuity, corrected distance visual acuity, uncorrected distance visual acuity, defocus curve, and ocular and corneal HOAs were examined 1 month after surgery. All near visual acuity measurements were taken with a 4-mm external aperture after pharmacologic dilation. Eyes were divided into two groups according to the DCNVA: eyes with DCNVA of 0.4 logMAR (20/50 Snellen) or better (0.4 logMAR or better group) and eyes with DCNVA worse than 0.4 logMAR (0.4 logMAR or worse group). The HOAs for a 4-mm pupil between the two groups were compared. RESULTS: A total of 37 eyes of 36 patients were included. The mean ocular spherical aberration was −0.010 ± 0.033 μ m in the 0.4 logMAR or better group and −0.012 ± 0.023 μ m in the 0.4 logMAR or worse group ( P = .28). Among ocular HOAs, only vertical coma Z 3 −1 showed a significant difference between the groups, with a mean ocular vertical coma of −0.038 ± 0.043 μ m in the 0.4 logMAR or better group and 0.015 ± 0.061 μ m in the 0.4 logMAR or worse group ( P = .01). In corneal HOAs, no components showed a significant difference between the groups. CONCLUSIONS: In cases of aspheric intraocular lens implantation, ocular vertical coma may be a major HOA associated with better near visual acuity. Although corneal aberrations are major determinants of ocular aberrations after cataract surgery, aberrations from internal optics may still play an important role in visual performance. [ J Refract Surg. 2014;30(7):442–446.]
- Open Access
- 1 January 2014
- Published by Korean Medical Association in Journal of the Korean Medical Association
- Vol. 57 (6) , 520-524
Surgical treatment of presbyopia
Park JH, et al. J Korean Med Assoc. 2014 Jun;57(6):520-524. http://dx.doi.org/10.5124/jkma.2014.57.6.520
- 1 January 2014
- Published by Korean Medical Association in Journal of the Korean Medical Association
- Vol. 57 (6) , 520-524
Open AccessSurgical treatment of presbyopia
Park JH, et al. J Korean Med Assoc. 2014 Jun;57(6):520-524. http://dx.doi.org/10.5124/jkma.2014.57.6.520
- Open Access
- 1 January 2012
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 53 (11) , 1559-1563
Estimation of Corneal Spherical Aberration from Topography
- 1 January 2012
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 53 (11) , 1559-1563
Open AccessEstimation of Corneal Spherical Aberration from Topography
- 9 October 2009
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 29 (6) , 602-605
Changes of higher‐order aberrations with the use of various mydriatics
Advances in corneal refractive surgery have allowed ophthalmologists to correct ocular higher‐order aberrations. To obtain more information on the ocular aberrations generated from the optical axis, mydriasis is required. The aim of this study is to evaluate the changes in higher‐order aberrations with the use of various mydriatics. Higher‐order aberrations were measured in 21 eyes of 21 subjects (age range 24–37 years; 13 males, 8 females). Repeated measurements were conducted before and after the installation of three different mydriatics: 10% phenylephrine, 1% tropicamide, or 1% cyclopentolate. At a pupil size of 6 mm, the average root mean square value of higher‐order aberrations (HO‐RMS) was 0.430 μm in undilated eyes, and 0.413, 0.410, and 0.477 μm after installation of phenylephrine, tropicamide, and cyclopentolate, respectively. There were no statistically significant differences in the HO‐RMS between the four conditions. There was a significant difference in the spherical aberration between the undilated or phenylephrine‐treated eyes, compared to those treated with tropicamide or cyclopentolate. Cycloplegic mydriatics seemed to shift spherical aberration in a positive direction. These results suggest that mydriatics may affect higher‐order aberrations, especially spherical aberration, and this should be considered when performing wavefront analysis and when correcting wavefront errors.
- 9 October 2009
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 29 (6) , 602-605
Changes of higher‐order aberrations with the use of various mydriatics
Advances in corneal refractive surgery have allowed ophthalmologists to correct ocular higher‐order aberrations. To obtain more information on the ocular aberrations generated from the optical axis, mydriasis is required. The aim of this study is to evaluate the changes in higher‐order aberrations with the use of various mydriatics. Higher‐order aberrations were measured in 21 eyes of 21 subjects (age range 24–37 years; 13 males, 8 females). Repeated measurements were conducted before and after the installation of three different mydriatics: 10% phenylephrine, 1% tropicamide, or 1% cyclopentolate. At a pupil size of 6 mm, the average root mean square value of higher‐order aberrations (HO‐RMS) was 0.430 μm in undilated eyes, and 0.413, 0.410, and 0.477 μm after installation of phenylephrine, tropicamide, and cyclopentolate, respectively. There were no statistically significant differences in the HO‐RMS between the four conditions. There was a significant difference in the spherical aberration between the undilated or phenylephrine‐treated eyes, compared to those treated with tropicamide or cyclopentolate. Cycloplegic mydriatics seemed to shift spherical aberration in a positive direction. These results suggest that mydriatics may affect higher‐order aberrations, especially spherical aberration, and this should be considered when performing wavefront analysis and when correcting wavefront errors.
- Open Access
- 1 January 2009
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 50 (4) , 523-528
Comparison of Formulas for Intraocular Lens Power Calculation Installed in a Partial Coherence Interferometer
- 1 January 2009
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 50 (4) , 523-528
Open AccessComparison of Formulas for Intraocular Lens Power Calculation Installed in a Partial Coherence Interferometer