Haomiao Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haomiao Yuan has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Jian Song
Precision Engineering Laboratory, Ostwestfalen-Lippe University of Applied Sciences and Arts, Lemgo, Germany
4 shared publications Vitali Schinow
Precision Engineering Laboratory, Ostwestfalen-Lippe University of Applied Sciences, Lemgo, Germany
1 shared publication
Latest Publications
- Open Access
- 13 January 2026
- Published by Springer Nature in Mining, Metallurgy & Exploration
- Vol. 43 (1) , 639-655
Influence of Core/Shell Nanoparticles on the Fretting Behavior of Gold Coated Electrical Contacts
A protective coating is usually applied in electrical contacts to prevent corrosion and fretting corrosion and to extend the lifetime of electrical contacts. A gold coating is recommended for applications functioning under very severe operation conditions, such as highly corrosive environments, or where a stable current should be reliably guaranteed even at very low voltage. However, the high price of gold material limits the use of gold coatings. Thus, a method to reduce gold consumption, for example to lower the required gold coating thickness without decreasing the lifetime and performance of the gold coating is of great interest. In this paper, a method to fabricate a novel gold coating co-deposited with nanoparticles with a core/shell structure, i.e. Ag (shell) @ Al 2 O 3 (core), is introduced. The influence of the nanoparticle concentration in the electrolyte and the agitation of the galvanic bath on the lifetime of the nanoparticles co-deposited gold coating is investigated. By co-depositing the Ag @ Al 2 O 3 nanoparticles, the microhardness of the gold coating is increased by around 30% compared to the pure gold coating; however, there is no significant difference in the microhardness among the co-deposited coatings fabricated with the different Ag @ Al 2 O 3 nanoparticle concentration in the electrolyte. The lifetime is also significantly prolonged by nanoparticle co-deposition. A favored nanoparticle concentration in the electrolyte is determined with regard to the topic of lifetime. The gold coatings made of the favored nanoparticle concentration in the electrolyte show a 2.2-fold of the average lifetime of the pure gold coating in the wear and fretting corrosion test. When considering the best lifetime of the nanoparticle co-deposited coating, the value is 4.3-fold of the lifetime of the pure gold coating. By employing a higher bath agitation in the electroplating process, a smoother nanoparticles co-deposited gold coating with fewer pores and finer grains is produced, which improves the average lifetime of the coatings to 3.7-fold of the co-deposited coatings produced under a lower bath agitation, while the standard deviation of the lifetime of the coatings in the wear and fretting corrosion test is decreased. Moreover, the mechanism of lifetime enhancement is discussed.
- 13 January 2026
- Published by Springer Nature in Mining, Metallurgy & Exploration
- Vol. 43 (1) , 639-655
Open AccessInfluence of Core/Shell Nanoparticles on the Fretting Behavior of Gold Coated Electrical Contacts
A protective coating is usually applied in electrical contacts to prevent corrosion and fretting corrosion and to extend the lifetime of electrical contacts. A gold coating is recommended for applications functioning under very severe operation conditions, such as highly corrosive environments, or where a stable current should be reliably guaranteed even at very low voltage. However, the high price of gold material limits the use of gold coatings. Thus, a method to reduce gold consumption, for example to lower the required gold coating thickness without decreasing the lifetime and performance of the gold coating is of great interest. In this paper, a method to fabricate a novel gold coating co-deposited with nanoparticles with a core/shell structure, i.e. Ag (shell) @ Al 2 O 3 (core), is introduced. The influence of the nanoparticle concentration in the electrolyte and the agitation of the galvanic bath on the lifetime of the nanoparticles co-deposited gold coating is investigated. By co-depositing the Ag @ Al 2 O 3 nanoparticles, the microhardness of the gold coating is increased by around 30% compared to the pure gold coating; however, there is no significant difference in the microhardness among the co-deposited coatings fabricated with the different Ag @ Al 2 O 3 nanoparticle concentration in the electrolyte. The lifetime is also significantly prolonged by nanoparticle co-deposition. A favored nanoparticle concentration in the electrolyte is determined with regard to the topic of lifetime. The gold coatings made of the favored nanoparticle concentration in the electrolyte show a 2.2-fold of the average lifetime of the pure gold coating in the wear and fretting corrosion test. When considering the best lifetime of the nanoparticle co-deposited coating, the value is 4.3-fold of the lifetime of the pure gold coating. By employing a higher bath agitation in the electroplating process, a smoother nanoparticles co-deposited gold coating with fewer pores and finer grains is produced, which improves the average lifetime of the coatings to 3.7-fold of the co-deposited coatings produced under a lower bath agitation, while the standard deviation of the lifetime of the coatings in the wear and fretting corrosion test is decreased. Moreover, the mechanism of lifetime enhancement is discussed.
- Open Access
- 31 October 2019
- Published by MDPI AG in Technologies
- Vol. 7 (4) , 77
An Improved Calculation Model for the Prediction of the Wear of Coated Electrical Contacts
To connect terminals in a cyber–physical system, large quantities of electrical contacts are used. In order to guarantee a high reliability of the system, the lifetime of the electrical contacts should be very long. Thus, it is of great importance to understand the failure mechanism and then to predict the lifetime of the electrical contacts. For the applications under high thermal and/or mechanical loads, noble plating is a good choice, considering its inertness to oxidation. For noble plating, one of the most critical failure mechanisms is the fretting wear. Wear debris generated in the contact area, acting as the third bodies, will greatly influence the further wear behavior and electrical performance. In this study, the state of the art regarding third bodies is firstly reviewed, and then the influence of the third bodies on the wear and electrical performance is investigated, from the aspects of lifetime and the element distributions in contact area. Finally, an example of prediction of the wear of noble plating is shown with the consideration of the third bodies. Based on this study, by involving the third bodies, the wear of noble plating can be predicted with a higher accuracy.
- 31 October 2019
- Published by MDPI AG in Technologies
- Vol. 7 (4) , 77
Open AccessAn Improved Calculation Model for the Prediction of the Wear of Coated Electrical Contacts
To connect terminals in a cyber–physical system, large quantities of electrical contacts are used. In order to guarantee a high reliability of the system, the lifetime of the electrical contacts should be very long. Thus, it is of great importance to understand the failure mechanism and then to predict the lifetime of the electrical contacts. For the applications under high thermal and/or mechanical loads, noble plating is a good choice, considering its inertness to oxidation. For noble plating, one of the most critical failure mechanisms is the fretting wear. Wear debris generated in the contact area, acting as the third bodies, will greatly influence the further wear behavior and electrical performance. In this study, the state of the art regarding third bodies is firstly reviewed, and then the influence of the third bodies on the wear and electrical performance is investigated, from the aspects of lifetime and the element distributions in contact area. Finally, an example of prediction of the wear of noble plating is shown with the consideration of the third bodies. Based on this study, by involving the third bodies, the wear of noble plating can be predicted with a higher accuracy.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 19-26
Fretting Corrosion Behavior of Various Contact Surfaces under Diverse Operating Conditions
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 19-26
Fretting Corrosion Behavior of Various Contact Surfaces under Diverse Operating Conditions
- 29 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 8 (3) , 364-374
Simulation Methodology for Prediction of the Wear on Silver-Coated Electrical Contacts With a Sphere/Flat Configuration
A protective coating is generally applied on base materials for better performance and a longer lifetime of electrical contacts. Silver is a widely used coating material, due to the good balance between the high resistance to corrosion caused by oxidation and the cost. Moreover, it possesses high electrical conductivity. Before the wear through of silver coatings, the electrical contact resistance is stable and remains at a low value, and thus, the reliability of electrical contacts can be guaranteed. After the wear through of silver coatings, the base material, typically a copper alloy, is exposed to the environment. The oxides of base materials are generated and accumulated, leading to blocking of the current path and an electrical failure of the contacts. Consequently, it is critical to predict the wear through of the silver coatings, when assessing the reliability of the electrical contacts. However, for a thick coating, it is difficult to forecast the wear through, since the linear wear rate of coatings decreases disproportionately with increasing coating thickness, and various phases exist, such as the running-in phase and the steady-state phase. In this paper, a simulation methodology based on Archard's wear equation and consideration of both the surface roughness and geometry of the contact area is established in order to interpret the wear process of thick silver coatings with an as-received roughness applied in the electrical contacts with a sphere/flat configuration. The specific wear coefficient is regressed by curve fitting, according to the experimental results in the running-in phase and results from finite element analysis computation. Then, a modification of the regressed specific wear coefficient is conducted, considering the simplification of the roughness on the flat part and the gaps on the roughness ribs introduced by the rolling process. This modified specific wear coefficient is applied in the calculation model for the steady-state phase in order to predict the wear through of silver coatings. A good correlation between the simulated wear curve and the experimental results is obtained.
- 29 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 8 (3) , 364-374
Simulation Methodology for Prediction of the Wear on Silver-Coated Electrical Contacts With a Sphere/Flat Configuration
A protective coating is generally applied on base materials for better performance and a longer lifetime of electrical contacts. Silver is a widely used coating material, due to the good balance between the high resistance to corrosion caused by oxidation and the cost. Moreover, it possesses high electrical conductivity. Before the wear through of silver coatings, the electrical contact resistance is stable and remains at a low value, and thus, the reliability of electrical contacts can be guaranteed. After the wear through of silver coatings, the base material, typically a copper alloy, is exposed to the environment. The oxides of base materials are generated and accumulated, leading to blocking of the current path and an electrical failure of the contacts. Consequently, it is critical to predict the wear through of the silver coatings, when assessing the reliability of the electrical contacts. However, for a thick coating, it is difficult to forecast the wear through, since the linear wear rate of coatings decreases disproportionately with increasing coating thickness, and various phases exist, such as the running-in phase and the steady-state phase. In this paper, a simulation methodology based on Archard's wear equation and consideration of both the surface roughness and geometry of the contact area is established in order to interpret the wear process of thick silver coatings with an as-received roughness applied in the electrical contacts with a sphere/flat configuration. The specific wear coefficient is regressed by curve fitting, according to the experimental results in the running-in phase and results from finite element analysis computation. Then, a modification of the regressed specific wear coefficient is conducted, considering the simplification of the roughness on the flat part and the gaps on the roughness ribs introduced by the rolling process. This modified specific wear coefficient is applied in the calculation model for the steady-state phase in order to predict the wear through of silver coatings. A good correlation between the simulated wear curve and the experimental results is obtained.