Ivan Frollo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ivan Frollo has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Jiří Přibil
Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia
12 shared publications - Anna Přibilová
Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia
11 shared publications - Oliver Strbak
Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Mala Hora 4, 036 01 Martin, Slovakia
6 shared publications - Andrej Krafcik
Department of Imaging Methods, Institute of Measurement Science Slovak Academy of Sciences Bratislava Slovakia
5 shared publications D. Gogola
Institute of Measurement Science, SAS, Dubravska cesta 9, 841 04 Bratislava 4, Slovakia
4 shared publications- Peter Babinec
Department of Nuclear Physics and Biophysics, Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynska dolina F1, 842 48 Bratislava, Slovakia
4 shared publications
Latest Publications
- Open Access
- 26 November 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 82 (1) , 10
Wearable Reflectance PPG Optical Sensor Enabling Contact Pressure and Skin Temperature Measurement
This paper describes the design, realization, and application of a wearable sensor based on the photoplethysmography (PPG) principle supplemented with a force-sensitive resistor and a thermometer for the measurement of contact pressure force and the temperature of the skin at the point where the optical part of the PPG sensor touches the finger. The performed experiments confirmed the essential influence of the applied contact force on the amplitude and ripple of the sensed PPG signal and the stability and precision of heart rate values determined from the PPG wave. Preliminary measurements showed that the response to the applied contact force was principally different for fingers of male and female tested persons, so different scaling and pressure levels were applied in the main experiments. Contrariwise, differences between left and right hands were not significant. The influence of skin temperature changes could be ignored for these measurements due to the short time duration of the PPG signal recording (approx. 1 min).
- 26 November 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 82 (1) , 10
Open AccessWearable Reflectance PPG Optical Sensor Enabling Contact Pressure and Skin Temperature Measurement
This paper describes the design, realization, and application of a wearable sensor based on the photoplethysmography (PPG) principle supplemented with a force-sensitive resistor and a thermometer for the measurement of contact pressure force and the temperature of the skin at the point where the optical part of the PPG sensor touches the finger. The performed experiments confirmed the essential influence of the applied contact force on the amplitude and ripple of the sensed PPG signal and the stability and precision of heart rate values determined from the PPG wave. Preliminary measurements showed that the response to the applied contact force was principally different for fingers of male and female tested persons, so different scaling and pressure levels were applied in the main experiments. Contrariwise, differences between left and right hands were not significant. The influence of skin temperature changes could be ignored for these measurements due to the short time duration of the PPG signal recording (approx. 1 min).
- Open Access
- 20 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (16) , 3297
Heart Pulse Transmission Parameters of Multi-Channel PPG Signals for Cuffless Estimation of Arterial Blood Pressure: Preliminary Study
The paper describes a method developed for the indirect cuffless estimation of arterial blood pressure (ABP) from two/three-channel photoplethysmography (PPG) signals. It is important when the actual ABPs cannot be measured, e.g., during scanning inside a magnetic resonance imager. The proposed procedure uses heart pulse transmission parameters (HPTPs) extracted from the second derivative PPG signals. The linear regression method was used to calculate the relation between the determined HPTPs and the ABPs measured in parallel by a blood pressure monitor. The ABP values were estimated by the inverse conversion characteristic calculated from these linear relations. Three auxiliary investigations were performed first to find appropriate settings for PPG signal processing. We tested the accuracy of ABP estimation using two small corpora of multi-channel PPG records sensed during our previous experiments. We also analyzed the distribution of the determined HPTP values depending on the hand and gender for the mapping of a mutual relationship of HPTPs and measured ABPs. The final estimation errors were evaluated graphically (by correlation scatter plots and Bland–Altman plots) and numerically (by a correlation coefficient between the measured and estimated ABPs and by enumeration of the relative estimation error). The obtained results achieve acceptable mean values of −2.6/−3.5 mm Hg for systolic/diastolic ABPs.
- 20 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (16) , 3297
Open AccessHeart Pulse Transmission Parameters of Multi-Channel PPG Signals for Cuffless Estimation of Arterial Blood Pressure: Preliminary Study
The paper describes a method developed for the indirect cuffless estimation of arterial blood pressure (ABP) from two/three-channel photoplethysmography (PPG) signals. It is important when the actual ABPs cannot be measured, e.g., during scanning inside a magnetic resonance imager. The proposed procedure uses heart pulse transmission parameters (HPTPs) extracted from the second derivative PPG signals. The linear regression method was used to calculate the relation between the determined HPTPs and the ABPs measured in parallel by a blood pressure monitor. The ABP values were estimated by the inverse conversion characteristic calculated from these linear relations. Three auxiliary investigations were performed first to find appropriate settings for PPG signal processing. We tested the accuracy of ABP estimation using two small corpora of multi-channel PPG records sensed during our previous experiments. We also analyzed the distribution of the determined HPTP values depending on the hand and gender for the mapping of a mutual relationship of HPTPs and measured ABPs. The final estimation errors were evaluated graphically (by correlation scatter plots and Bland–Altman plots) and numerically (by a correlation coefficient between the measured and estimated ABPs and by enumeration of the relative estimation error). The obtained results achieve acceptable mean values of −2.6/−3.5 mm Hg for systolic/diastolic ABPs.
- 2 March 2024
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 38 (26)
Finite element modeling of the rotational dynamics of a single magnetic particle in a strong magnetic field and liquid medium
We have performed a comparative computational study of magnetic particle alignment in a strong magnetic field and ambient viscous fluid using the first-principles Navier–Stokes equation as well as numerical modeling using the finite element method (FEM). FEM solution has been compared with the solution of the unsteady rotations of a magnetic particle in a viscous fluid during the alignment process described with nonlocal integro-differential equations (IDEs) for torque and angular velocity. The assumption of nonlocality comes from the history term of acceleration torque with a non-Basset kernel function, which has its origin in the presence of vortices in the flow of a particle fluid environment due to its unsteady rotation and ambient fluid inertia and friction. The flow vortices of the ambient fluid are explicitly shown in the solution of the FEM model. Moreover, the solution of the time evolution of the alignment angle and angular velocity for the FEM model are in good agreement with an IDE model which we have recently developed. The obtained results are justification for interchangeability of the FEM and IDE models, which may have important consequences for large-scale simulations of magnetic microparticles.
- 2 March 2024
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 38 (26)
Finite element modeling of the rotational dynamics of a single magnetic particle in a strong magnetic field and liquid medium
We have performed a comparative computational study of magnetic particle alignment in a strong magnetic field and ambient viscous fluid using the first-principles Navier–Stokes equation as well as numerical modeling using the finite element method (FEM). FEM solution has been compared with the solution of the unsteady rotations of a magnetic particle in a viscous fluid during the alignment process described with nonlocal integro-differential equations (IDEs) for torque and angular velocity. The assumption of nonlocality comes from the history term of acceleration torque with a non-Basset kernel function, which has its origin in the presence of vortices in the flow of a particle fluid environment due to its unsteady rotation and ambient fluid inertia and friction. The flow vortices of the ambient fluid are explicitly shown in the solution of the FEM model. Moreover, the solution of the time evolution of the alignment angle and angular velocity for the FEM model are in good agreement with an IDE model which we have recently developed. The obtained results are justification for interchangeability of the FEM and IDE models, which may have important consequences for large-scale simulations of magnetic microparticles.
- Open Access
- 15 November 2023
- Published by MDPI AG
- Vol. 58 (1) , 108
Wearable Two-Channel PPG Optical Sensor with Integrated Thermometers for Contact Measurement of Skin Temperature
Many factors affect photoplethysmography (PPG) signal quality, one of them being the actual temperature of the skin surface. This paper describes the process of design, realization, and testing of a special wearable PPG sensor prototype with the contact thermometer measuring in detail the skin temperature in the place where the optical part of the PPG sensor touches a finger/wrist. Performed experiments confirm continual increase of temperature at the place of worn PPG sensors during the whole measurement, influencing mainly the PPG signal range. Other parameters seem to be temperature-independent or influenced by other factors—blood pressure, heart rate, etc.
- 15 November 2023
- Published by MDPI AG
- Vol. 58 (1) , 108
Open AccessWearable Two-Channel PPG Optical Sensor with Integrated Thermometers for Contact Measurement of Skin Temperature
Many factors affect photoplethysmography (PPG) signal quality, one of them being the actual temperature of the skin surface. This paper describes the process of design, realization, and testing of a special wearable PPG sensor prototype with the contact thermometer measuring in detail the skin temperature in the place where the optical part of the PPG sensor touches a finger/wrist. Performed experiments confirm continual increase of temperature at the place of worn PPG sensors during the whole measurement, influencing mainly the PPG signal range. Other parameters seem to be temperature-independent or influenced by other factors—blood pressure, heart rate, etc.
- Open Access
- 1 November 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 27 (1) , 51
Experiment with Cuffless Estimation of Arterial Blood Pressure from the Signal Sensed by the Optical PPG Sensor
The paper describes the development, testing, and verification of practical usability of the indirect cuffless method for estimation of arterial blood pressure (ABP) values from the photo-plethysmography (PPG) signal sensed by the optical PPG sensor. The proposed procedure uses time domain features (systolic/diastolic pulse time ratios and partial areas around the pulses) extracted from the second derivative of the PPG signal. The linear regression method is next used to calculate the relation between the determined PPG wave features and the blood pressure values measured in parallel using a blood pressure monitor. ABP values are finally estimated by the inverse conversion characteristic calculated from these linear relations. Summary estimation errors obtained from first-step experiments achieve acceptable values of about 8/3% for systolic/diastolic ABPs. However, further improvements are necessary before usage of the proposed procedure.
- 1 November 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 27 (1) , 51
Open AccessExperiment with Cuffless Estimation of Arterial Blood Pressure from the Signal Sensed by the Optical PPG Sensor
The paper describes the development, testing, and verification of practical usability of the indirect cuffless method for estimation of arterial blood pressure (ABP) values from the photo-plethysmography (PPG) signal sensed by the optical PPG sensor. The proposed procedure uses time domain features (systolic/diastolic pulse time ratios and partial areas around the pulses) extracted from the second derivative of the PPG signal. The linear regression method is next used to calculate the relation between the determined PPG wave features and the blood pressure values measured in parallel using a blood pressure monitor. ABP values are finally estimated by the inverse conversion characteristic calculated from these linear relations. Summary estimation errors obtained from first-step experiments achieve acceptable values of about 8/3% for systolic/diastolic ABPs. However, further improvements are necessary before usage of the proposed procedure.
- Open Access
- 12 March 2022
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 22 (2) , 80-83
Analysis of NMR Signal for Static Magnetic Field Standard
This article describes the analysis of the NMR (Nuclear Magnetic Resonance) stabilizer signal. Magnetic field of the standard is created using an electromagnet. Sufficiently high stability of the magnetic field is achieved with the help of a stabilizer with an NMR probe. The NMR phenomenon makes possible very accurate measurements of the static magnetic field, but the resulting stability depends also on supporting electronics. An analysis has been done and tolerances of the measured quantities have been estimated. The calculated tolerances indicate the needed features of the material. First the probe excites the FID (Free Induction Decay) signal in the water sample and acquires the signal answer. It is Fourier transformed and its spectrum is investigated. The actual magnetic field corresponds to the strongest frequency sample. It is utilized for the magnetic field strength correction and stabilization of it. The article brings many equations for such calculation.
- 12 March 2022
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 22 (2) , 80-83
Open AccessAnalysis of NMR Signal for Static Magnetic Field Standard
This article describes the analysis of the NMR (Nuclear Magnetic Resonance) stabilizer signal. Magnetic field of the standard is created using an electromagnet. Sufficiently high stability of the magnetic field is achieved with the help of a stabilizer with an NMR probe. The NMR phenomenon makes possible very accurate measurements of the static magnetic field, but the resulting stability depends also on supporting electronics. An analysis has been done and tolerances of the measured quantities have been estimated. The calculated tolerances indicate the needed features of the material. First the probe excites the FID (Free Induction Decay) signal in the water sample and acquires the signal answer. It is Fourier transformed and its spectrum is investigated. The actual magnetic field corresponds to the strongest frequency sample. It is utilized for the magnetic field strength correction and stabilization of it. The article brings many equations for such calculation.
- Open Access
- 10 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11748
Stress Level Detection and Evaluation from Phonation and PPG Signals Recorded in an Open-Air MRI Device
This paper deals with two modalities for stress detection and evaluation—vowel phonation speech signal and photo-plethysmography (PPG) signal. The main measurement is carried out in four phases representing different stress conditions for the tested person. The first and last phases are realized in laboratory conditions. The PPG and phonation signals are recorded inside the magnetic resonance imaging scanner working with a weak magnetic field up to 0.2 T in a silent state and/or with a running scan sequence during the middle two phases. From the recorded phonation signal, different speech features are determined for statistical analysis and evaluation by the Gaussian mixture models (GMM) classifier. A database of affective sounds and two databases of emotional speech were used for GMM creation and training. The second part of the developed method gives comparison of results obtained from the statistical description of the sensed PPG wave together with the determined heart rate and Oliva–Roztocil index values. The fusion of results obtained from both modalities gives the final stress level. The performed experiments confirm our working assumption that a fusion of both types of analysis is usable for this task—the final stress level values give better results than the speech or PPG signals alone.
- 10 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11748
Open AccessStress Level Detection and Evaluation from Phonation and PPG Signals Recorded in an Open-Air MRI Device
This paper deals with two modalities for stress detection and evaluation—vowel phonation speech signal and photo-plethysmography (PPG) signal. The main measurement is carried out in four phases representing different stress conditions for the tested person. The first and last phases are realized in laboratory conditions. The PPG and phonation signals are recorded inside the magnetic resonance imaging scanner working with a weak magnetic field up to 0.2 T in a silent state and/or with a running scan sequence during the middle two phases. From the recorded phonation signal, different speech features are determined for statistical analysis and evaluation by the Gaussian mixture models (GMM) classifier. A database of affective sounds and two databases of emotional speech were used for GMM creation and training. The second part of the developed method gives comparison of results obtained from the statistical description of the sensed PPG wave together with the determined heart rate and Oliva–Roztocil index values. The fusion of results obtained from both modalities gives the final stress level. The performed experiments confirm our working assumption that a fusion of both types of analysis is usable for this task—the final stress level values give better results than the speech or PPG signals alone.
- 29 November 2021
- Published by Walter de Gruyter GmbH in International Journal of Nonlinear Sciences and Numerical Simulation
- Vol. 23 (7-8) , 971-983
Computational study of intravenous magnetic drug targeting using implanted magnetizable stent
Magnetic carriers for guiding, delivery, and capturing of drugs to desired place attract interest in the field of smart treatment of various pathological conditions. Presented paper, therefore, deals with one such application with the theoretical model of magnetic fluid flow through vessel bifurcation with one arm treated with ferromagnetic vascular stent placed in an external originally homogeneous magnetic field. This flow was described as laminar Newtonian incompressible continuum of the magnetic many-bead system, with Reynolds number ≈ 1 $\approx 1$ , using magnetic force variant of the Nernst–Planck equation coupled with the Navier–Stokes equations, solved numerically by the finite element method (FEM). This approach allowed us to quantify capturing efficiency of magnetic beads in each arm of bifurcation vessels. Results show reduction of the number of magnetic beads entering as well as leaving the arm treated with stent in comparison with the untreated one. For stented bifurcation arm, the significant amount of beads are captured to its luminal surface, which may be used for drug delivery using magnetic carriers.- 29 November 2021
- Published by Walter de Gruyter GmbH in International Journal of Nonlinear Sciences and Numerical Simulation
- Vol. 23 (7-8) , 971-983
Computational study of intravenous magnetic drug targeting using implanted magnetizable stent
Magnetic carriers for guiding, delivery, and capturing of drugs to desired place attract interest in the field of smart treatment of various pathological conditions. Presented paper, therefore, deals with one such application with the theoretical model of magnetic fluid flow through vessel bifurcation with one arm treated with ferromagnetic vascular stent placed in an external originally homogeneous magnetic field. This flow was described as laminar Newtonian incompressible continuum of the magnetic many-bead system, with Reynolds number ≈ 1 $\approx 1$ , using magnetic force variant of the Nernst–Planck equation coupled with the Navier–Stokes equations, solved numerically by the finite element method (FEM). This approach allowed us to quantify capturing efficiency of magnetic beads in each arm of bifurcation vessels. Results show reduction of the number of magnetic beads entering as well as leaving the arm treated with stent in comparison with the untreated one. For stented bifurcation arm, the significant amount of beads are captured to its luminal surface, which may be used for drug delivery using magnetic carriers.- Open Access
- 1 November 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 10 (1) , 55
Two Realizations of the Wearable PPG Sensor Working in Reflectance Mode for Measurement in Weak Magnetic Field
The paper describes and compares properties of two realizations of wearable sensors based on the photoplethysmography (PPG) principle for non-invasive acquisition of the human heart rate. The designed sensors enable measurement of the PPG signal in the magnetic field environment with the inherent radiofrequency and electromagnetic disturbance. They can monitor the stress of a tested person during examination in the scanning area of the open-air magnetic resonance tomograph. The performed auxiliary experiments verify the practical functionality of both developed sensors including real-time wireless transmission of the measured PPG signal samples to the control device for further analysis and processing.
- 1 November 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 10 (1) , 55
Open AccessTwo Realizations of the Wearable PPG Sensor Working in Reflectance Mode for Measurement in Weak Magnetic Field
The paper describes and compares properties of two realizations of wearable sensors based on the photoplethysmography (PPG) principle for non-invasive acquisition of the human heart rate. The designed sensors enable measurement of the PPG signal in the magnetic field environment with the inherent radiofrequency and electromagnetic disturbance. They can monitor the stress of a tested person during examination in the scanning area of the open-air magnetic resonance tomograph. The performed auxiliary experiments verify the practical functionality of both developed sensors including real-time wireless transmission of the measured PPG signal samples to the control device for further analysis and processing.
- Open Access
- 15 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (20) , 9651
A Theoretical Analysis of Magnetic Particle Alignment in External Magnetic Fields Affected by Viscosity and Brownian Motion
The interaction of an external magnetic field with magnetic objects affects their response and is a fundamental property for many biomedical applications, including magnetic resonance and particle imaging, electromagnetic hyperthermia, and magnetic targeting and separation. Magnetic alignment and relaxation are widely studied in the context of these applications. In this study, we theoretically investigate the alignment dynamics of a rotational magnetic particle as an inverse process to Brownian relaxation. The selected external magnetic flux density ranges from to . We found that the viscous torque for arbitrary rotating particles with a history term due to the inertia and friction of the surrounding ambient water has a significant effect in strong magnetic fields (range 1–). In this range, oscillatory behavior due to the inertial torque of the particle also occurs, and the stochastic Brownian torque diminishes. In contrast, for weak fields (range 5–), the history term of the viscous torque and the inertial torque can be neglected, and the stochastic Brownian torque induced by random collisions of the surrounding fluid molecules becomes dominant. These results contribute to a better understanding of the molecular mechanisms of magnetic particle alignment in external magnetic fields and have important implications in a variety of biomedical applications.- 15 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (20) , 9651
Open AccessA Theoretical Analysis of Magnetic Particle Alignment in External Magnetic Fields Affected by Viscosity and Brownian Motion
The interaction of an external magnetic field with magnetic objects affects their response and is a fundamental property for many biomedical applications, including magnetic resonance and particle imaging, electromagnetic hyperthermia, and magnetic targeting and separation. Magnetic alignment and relaxation are widely studied in the context of these applications. In this study, we theoretically investigate the alignment dynamics of a rotational magnetic particle as an inverse process to Brownian relaxation. The selected external magnetic flux density ranges from to . We found that the viscous torque for arbitrary rotating particles with a history term due to the inertia and friction of the surrounding ambient water has a significant effect in strong magnetic fields (range 1–). In this range, oscillatory behavior due to the inertial torque of the particle also occurs, and the stochastic Brownian torque diminishes. In contrast, for weak fields (range 5–), the history term of the viscous torque and the inertial torque can be neglected, and the stochastic Brownian torque induced by random collisions of the surrounding fluid molecules becomes dominant. These results contribute to a better understanding of the molecular mechanisms of magnetic particle alignment in external magnetic fields and have important implications in a variety of biomedical applications.