Anna Přibilová
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anna Přibilová has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jiří Přibil
Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia
58 shared publications - Jindřich Matoušek
University of West Bohemia in Pilsen
16 shared publications - Ivan Frollo
Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia
11 shared publications Ivan Frollo
7 shared publications- Ivan Frollo
Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia
4 shared publications J. Pribil
4 shared publications
Latest Publications
- Open Access
- 13 November 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 163 (1) , 111
Investigation of Features of Three Wearable PPG Multi-Sensors for Measurement in Low Magnetic Field MRI Tomograph
The paper presents an investigation of three implementations of wearable multi-sensors with Bluetooth connectivity for use in a low-field magnetic environment. The prototypes are based on photoplethysmography (PPG) optical sensors and additionally incorporate temperature and humidity sensors and a force-sensitive resistor (FSR) that can also be used to detect cardiac pulsations. Comparative measurements with a certified pulse oximeter were performed to assess the accuracy of heart-rate (HR) values determined from PPG and FSR signals. The statistical properties of the HR sequences obtained from PPG signals were better than those obtained from FSR signals. Substantial differences in mean absolute error (MAE) were also observed between signals acquired from the left and right hands. Overall, the results demonstrate acceptable accuracy, with MAE below 2 min−1, which is comparable to that of other PPG-based measurement systems.
- 13 November 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 163 (1) , 111
Open AccessInvestigation of Features of Three Wearable PPG Multi-Sensors for Measurement in Low Magnetic Field MRI Tomograph
The paper presents an investigation of three implementations of wearable multi-sensors with Bluetooth connectivity for use in a low-field magnetic environment. The prototypes are based on photoplethysmography (PPG) optical sensors and additionally incorporate temperature and humidity sensors and a force-sensitive resistor (FSR) that can also be used to detect cardiac pulsations. Comparative measurements with a certified pulse oximeter were performed to assess the accuracy of heart-rate (HR) values determined from PPG and FSR signals. The statistical properties of the HR sequences obtained from PPG signals were better than those obtained from FSR signals. Substantial differences in mean absolute error (MAE) were also observed between signals acquired from the left and right hands. Overall, the results demonstrate acceptable accuracy, with MAE below 2 min−1, which is comparable to that of other PPG-based measurement systems.
- Open Access
- 14 December 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (12) , 1361
Wearable PPG Multi-Sensor for Skin Humidity, Temperature, and Contact Pressure Measurement in Weak Magnetic Field Environment: First-Step Experiments
This study describes the developed special prototype of a wearable measuring device based on a photoplethysmography (PPG) sensor. It contains also a humidity sensor and a thermometer to measure skin moisture and temperature, and a force-sensitive (FSR) element to sense a contact pressure between the measuring probe and the skin surface. All parts of the multi-sensor are shielded, to be applicable in a weak magnetic field environment. After the basic sensor’s functionality verification inside the magnetic resonance imaging tomograph, a set of experiments was performed. Comparative measurements by an oximeter confirm good correspondence with heart rate values determined from PPG (HRPPG) and FSR (HRFSR) signals—the mean absolute error lies below 0.5 min−1 for both types. The sensing of PPG signals on wrists was realized for Normal, Dry, and Wet skin. In comparison with normal skin conditions, drying decreases the PPG signal range by 7% and the systolic pulse width by 8%, while moistening increases the signal ripple by 3% and decreases the correlation between HRPPG and HRFSR values by 5%. The detailed analysis per hand and gender types yields differences between male and female subjects, while the results for left and right hands differ less.
- 14 December 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (12) , 1361
Open AccessWearable PPG Multi-Sensor for Skin Humidity, Temperature, and Contact Pressure Measurement in Weak Magnetic Field Environment: First-Step Experiments
This study describes the developed special prototype of a wearable measuring device based on a photoplethysmography (PPG) sensor. It contains also a humidity sensor and a thermometer to measure skin moisture and temperature, and a force-sensitive (FSR) element to sense a contact pressure between the measuring probe and the skin surface. All parts of the multi-sensor are shielded, to be applicable in a weak magnetic field environment. After the basic sensor’s functionality verification inside the magnetic resonance imaging tomograph, a set of experiments was performed. Comparative measurements by an oximeter confirm good correspondence with heart rate values determined from PPG (HRPPG) and FSR (HRFSR) signals—the mean absolute error lies below 0.5 min−1 for both types. The sensing of PPG signals on wrists was realized for Normal, Dry, and Wet skin. In comparison with normal skin conditions, drying decreases the PPG signal range by 7% and the systolic pulse width by 8%, while moistening increases the signal ripple by 3% and decreases the correlation between HRPPG and HRFSR values by 5%. The detailed analysis per hand and gender types yields differences between male and female subjects, while the results for left and right hands differ less.
- Open Access
- 7 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 118 (1) , 71
A Wearable PPG Multi-Sensor for Measurement of Skin Humidity, Temperature, and Contact Pressure
The aim of our work was to analyze the influence of changes in humidity and temperature on temporal features of sensed photoplethysmography (PPG) waves. This paper describes a special prototype of a wearable PPG multi-sensor with an integrated I2C humidity sensor and a thermometer to carry out measurements at three skin moisture levels. This sensor is supplemented with a force-sensitive resistor for the measurement of the physical contact pressure between the measuring probe and the skin surface, which can be used to sense heart pulsation in the wrist radial artery. The experiments conducted show that the performed skin manipulation (skin drying, moistening) was always detectable; the PPG signal range is mainly affected, while changes in signal ripple and heart rate variance are smaller. The detailed analysis per hand and gender type yielded differences between male and female subjects, and the results for left and right hands differed less.
- 7 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 118 (1) , 71
Open AccessA Wearable PPG Multi-Sensor for Measurement of Skin Humidity, Temperature, and Contact Pressure
The aim of our work was to analyze the influence of changes in humidity and temperature on temporal features of sensed photoplethysmography (PPG) waves. This paper describes a special prototype of a wearable PPG multi-sensor with an integrated I2C humidity sensor and a thermometer to carry out measurements at three skin moisture levels. This sensor is supplemented with a force-sensitive resistor for the measurement of the physical contact pressure between the measuring probe and the skin surface, which can be used to sense heart pulsation in the wrist radial artery. The experiments conducted show that the performed skin manipulation (skin drying, moistening) was always detectable; the PPG signal range is mainly affected, while changes in signal ripple and heart rate variance are smaller. The detailed analysis per hand and gender type yielded differences between male and female subjects, and the results for left and right hands differed less.
- Open Access
- 1 April 2025
- Published by Walter de Gruyter GmbH in Journal of Electrical Engineering
- Vol. 76 (2) , 134-146
Wearable PPG optical sensor enabling contact pressure and skin temperature measurement
The article describes the design, realization, and testing of a new special prototype of a wearable sensor working on photoplethysmography (PPG) principle with a thermometer and a force-sensitive resistor (FSR) component. This sensor is primarily designated for measurement of skin temperature and applied contact pressure force (CPF) at the point where the optical part of the sensor touches a finger. At first, the sensor’s functionality including stability and quality of wireless connection was tested inside the running magnetic resonance tomograph. Next, the catalogue FSR’s resistance/force conversion characteristic was verified by comparative measurements by a set of calibration weights and its sufficient linearization was proposed. Reactions of applied different CPFs on finger(s) of males and females were mapped to find a proper methodology for the main experiment. The main measurements were realized in the normal laboratory conditions using five levels of CPF for male and female subjects separately. The obtained results confirm an essential influence of applied CPF on the PPG signal amplitude and ripple. Increasing of CPF causes also changes in the systolic pulse shape, while other PPG wave features seem to be less dependent on the CPF level. The skin temperature changes observed during the measurement were also minimal.
- 1 April 2025
- Published by Walter de Gruyter GmbH in Journal of Electrical Engineering
- Vol. 76 (2) , 134-146
Open AccessWearable PPG optical sensor enabling contact pressure and skin temperature measurement
The article describes the design, realization, and testing of a new special prototype of a wearable sensor working on photoplethysmography (PPG) principle with a thermometer and a force-sensitive resistor (FSR) component. This sensor is primarily designated for measurement of skin temperature and applied contact pressure force (CPF) at the point where the optical part of the sensor touches a finger. At first, the sensor’s functionality including stability and quality of wireless connection was tested inside the running magnetic resonance tomograph. Next, the catalogue FSR’s resistance/force conversion characteristic was verified by comparative measurements by a set of calibration weights and its sufficient linearization was proposed. Reactions of applied different CPFs on finger(s) of males and females were mapped to find a proper methodology for the main experiment. The main measurements were realized in the normal laboratory conditions using five levels of CPF for male and female subjects separately. The obtained results confirm an essential influence of applied CPF on the PPG signal amplitude and ripple. Increasing of CPF causes also changes in the systolic pulse shape, while other PPG wave features seem to be less dependent on the CPF level. The skin temperature changes observed during the measurement were also minimal.
- Open Access
- 2 December 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 260, 108519
Autocorrelation maps for optimal setting in cardiac resynchronization therapy
- 2 December 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 260, 108519
Open AccessAutocorrelation maps for optimal setting in cardiac resynchronization therapy
- Open Access
- 26 November 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 82 (1) , 10
Wearable Reflectance PPG Optical Sensor Enabling Contact Pressure and Skin Temperature Measurement
This paper describes the design, realization, and application of a wearable sensor based on the photoplethysmography (PPG) principle supplemented with a force-sensitive resistor and a thermometer for the measurement of contact pressure force and the temperature of the skin at the point where the optical part of the PPG sensor touches the finger. The performed experiments confirmed the essential influence of the applied contact force on the amplitude and ripple of the sensed PPG signal and the stability and precision of heart rate values determined from the PPG wave. Preliminary measurements showed that the response to the applied contact force was principally different for fingers of male and female tested persons, so different scaling and pressure levels were applied in the main experiments. Contrariwise, differences between left and right hands were not significant. The influence of skin temperature changes could be ignored for these measurements due to the short time duration of the PPG signal recording (approx. 1 min).
- 26 November 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 82 (1) , 10
Open AccessWearable Reflectance PPG Optical Sensor Enabling Contact Pressure and Skin Temperature Measurement
This paper describes the design, realization, and application of a wearable sensor based on the photoplethysmography (PPG) principle supplemented with a force-sensitive resistor and a thermometer for the measurement of contact pressure force and the temperature of the skin at the point where the optical part of the PPG sensor touches the finger. The performed experiments confirmed the essential influence of the applied contact force on the amplitude and ripple of the sensed PPG signal and the stability and precision of heart rate values determined from the PPG wave. Preliminary measurements showed that the response to the applied contact force was principally different for fingers of male and female tested persons, so different scaling and pressure levels were applied in the main experiments. Contrariwise, differences between left and right hands were not significant. The influence of skin temperature changes could be ignored for these measurements due to the short time duration of the PPG signal recording (approx. 1 min).
- Open Access
- 20 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (16) , 3297
Heart Pulse Transmission Parameters of Multi-Channel PPG Signals for Cuffless Estimation of Arterial Blood Pressure: Preliminary Study
The paper describes a method developed for the indirect cuffless estimation of arterial blood pressure (ABP) from two/three-channel photoplethysmography (PPG) signals. It is important when the actual ABPs cannot be measured, e.g., during scanning inside a magnetic resonance imager. The proposed procedure uses heart pulse transmission parameters (HPTPs) extracted from the second derivative PPG signals. The linear regression method was used to calculate the relation between the determined HPTPs and the ABPs measured in parallel by a blood pressure monitor. The ABP values were estimated by the inverse conversion characteristic calculated from these linear relations. Three auxiliary investigations were performed first to find appropriate settings for PPG signal processing. We tested the accuracy of ABP estimation using two small corpora of multi-channel PPG records sensed during our previous experiments. We also analyzed the distribution of the determined HPTP values depending on the hand and gender for the mapping of a mutual relationship of HPTPs and measured ABPs. The final estimation errors were evaluated graphically (by correlation scatter plots and Bland–Altman plots) and numerically (by a correlation coefficient between the measured and estimated ABPs and by enumeration of the relative estimation error). The obtained results achieve acceptable mean values of −2.6/−3.5 mm Hg for systolic/diastolic ABPs.
- 20 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (16) , 3297
Open AccessHeart Pulse Transmission Parameters of Multi-Channel PPG Signals for Cuffless Estimation of Arterial Blood Pressure: Preliminary Study
The paper describes a method developed for the indirect cuffless estimation of arterial blood pressure (ABP) from two/three-channel photoplethysmography (PPG) signals. It is important when the actual ABPs cannot be measured, e.g., during scanning inside a magnetic resonance imager. The proposed procedure uses heart pulse transmission parameters (HPTPs) extracted from the second derivative PPG signals. The linear regression method was used to calculate the relation between the determined HPTPs and the ABPs measured in parallel by a blood pressure monitor. The ABP values were estimated by the inverse conversion characteristic calculated from these linear relations. Three auxiliary investigations were performed first to find appropriate settings for PPG signal processing. We tested the accuracy of ABP estimation using two small corpora of multi-channel PPG records sensed during our previous experiments. We also analyzed the distribution of the determined HPTP values depending on the hand and gender for the mapping of a mutual relationship of HPTPs and measured ABPs. The final estimation errors were evaluated graphically (by correlation scatter plots and Bland–Altman plots) and numerically (by a correlation coefficient between the measured and estimated ABPs and by enumeration of the relative estimation error). The obtained results achieve acceptable mean values of −2.6/−3.5 mm Hg for systolic/diastolic ABPs.
- Open Access
- 1 April 2024
- Published by Walter de Gruyter GmbH in Journal of Electrical Engineering
- Vol. 75 (2) , 113-123
Contact measurement of skin temperature using a wearable two-channel PPG optical sensor supplemented by thermometers
- 1 April 2024
- Published by Walter de Gruyter GmbH in Journal of Electrical Engineering
- Vol. 75 (2) , 113-123
Open AccessContact measurement of skin temperature using a wearable two-channel PPG optical sensor supplemented by thermometers
- Open Access
- 15 November 2023
- Published by MDPI AG
- Vol. 58 (1) , 108
Wearable Two-Channel PPG Optical Sensor with Integrated Thermometers for Contact Measurement of Skin Temperature
Many factors affect photoplethysmography (PPG) signal quality, one of them being the actual temperature of the skin surface. This paper describes the process of design, realization, and testing of a special wearable PPG sensor prototype with the contact thermometer measuring in detail the skin temperature in the place where the optical part of the PPG sensor touches a finger/wrist. Performed experiments confirm continual increase of temperature at the place of worn PPG sensors during the whole measurement, influencing mainly the PPG signal range. Other parameters seem to be temperature-independent or influenced by other factors—blood pressure, heart rate, etc.
- 15 November 2023
- Published by MDPI AG
- Vol. 58 (1) , 108
Open AccessWearable Two-Channel PPG Optical Sensor with Integrated Thermometers for Contact Measurement of Skin Temperature
Many factors affect photoplethysmography (PPG) signal quality, one of them being the actual temperature of the skin surface. This paper describes the process of design, realization, and testing of a special wearable PPG sensor prototype with the contact thermometer measuring in detail the skin temperature in the place where the optical part of the PPG sensor touches a finger/wrist. Performed experiments confirm continual increase of temperature at the place of worn PPG sensors during the whole measurement, influencing mainly the PPG signal range. Other parameters seem to be temperature-independent or influenced by other factors—blood pressure, heart rate, etc.
- Open Access
- 1 November 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 27 (1) , 51
Experiment with Cuffless Estimation of Arterial Blood Pressure from the Signal Sensed by the Optical PPG Sensor
The paper describes the development, testing, and verification of practical usability of the indirect cuffless method for estimation of arterial blood pressure (ABP) values from the photo-plethysmography (PPG) signal sensed by the optical PPG sensor. The proposed procedure uses time domain features (systolic/diastolic pulse time ratios and partial areas around the pulses) extracted from the second derivative of the PPG signal. The linear regression method is next used to calculate the relation between the determined PPG wave features and the blood pressure values measured in parallel using a blood pressure monitor. ABP values are finally estimated by the inverse conversion characteristic calculated from these linear relations. Summary estimation errors obtained from first-step experiments achieve acceptable values of about 8/3% for systolic/diastolic ABPs. However, further improvements are necessary before usage of the proposed procedure.
- 1 November 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 27 (1) , 51
Open AccessExperiment with Cuffless Estimation of Arterial Blood Pressure from the Signal Sensed by the Optical PPG Sensor
The paper describes the development, testing, and verification of practical usability of the indirect cuffless method for estimation of arterial blood pressure (ABP) values from the photo-plethysmography (PPG) signal sensed by the optical PPG sensor. The proposed procedure uses time domain features (systolic/diastolic pulse time ratios and partial areas around the pulses) extracted from the second derivative of the PPG signal. The linear regression method is next used to calculate the relation between the determined PPG wave features and the blood pressure values measured in parallel using a blood pressure monitor. ABP values are finally estimated by the inverse conversion characteristic calculated from these linear relations. Summary estimation errors obtained from first-step experiments achieve acceptable values of about 8/3% for systolic/diastolic ABPs. However, further improvements are necessary before usage of the proposed procedure.