Zhi-Yu Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zhi-Yu Sun has a total of 755 co-authors. Here are the top co-authors by number of shared publications:
- Liangwen Chen
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
12 shared publications Yuhong Yu
12 shared publicationsFang Fang
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
11 shared publicationsYu-Hong Yu
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
11 shared publicationsShi-Tao Wang
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, No. 509 Nanchang Road, Lanzhou 730000
10 shared publications- Xue-Heng Zhang
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
9 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11) , 1292
Canton-$\mu $ proposal: a next-generation muon $g\!-\!2$ measurement at sub-0.1 ppm precisionWe propose a next-generation precision measurement of the muon anomalous magnetic moment (muon $$g\!-\!2$$ ) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON- $$\mu $$ ( Coherent Anomalous magNetic momenT ObservatioN with muon ). HIAF’s intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum. We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the $$0.05~\textrm{ppm}$$ level in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the $$10^{-24}\ \textrm{GeV}$$ level, an order of magnitude beyond current limits.- 9 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11) , 1292
Open AccessCanton-$\mu $ proposal: a next-generation muon $g\!-\!2$ measurement at sub-0.1 ppm precisionWe propose a next-generation precision measurement of the muon anomalous magnetic moment (muon $$g\!-\!2$$ ) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON- $$\mu $$ ( Coherent Anomalous magNetic momenT ObservatioN with muon ). HIAF’s intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum. We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the $$0.05~\textrm{ppm}$$ level in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the $$10^{-24}\ \textrm{GeV}$$ level, an order of magnitude beyond current limits. - 21 October 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (12) , 253
Construction and performance testing of the drift chambers at the target area of the external target facility of CSR
- 21 October 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (12) , 253
Construction and performance testing of the drift chambers at the target area of the external target facility of CSR
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , T10007
The identification methods of light charged particles with a CsI(Tl) detector based on the pulse shape analysis technique
Four types of pulse shape analysis (PSA) algorithms were examined with the objective of identifying the light charged particles utilizing a CsI(Tl) detector. These included the fall time comparison method, the charge comparison method, the Reconstructive Particle IDentification (RPID) method, and the Quick Particle IDentification (QPID) method. The beam test with the CsI(Tl) detector demonstrates that the charge comparison method, the RPID method, and the QPID method exhibit satisfactory capacities in identifying the incident particles of hydrogen and helium isotopes. Conversely, the fall time comparison method exhibits suboptimal performance in particle identification. The linearization process was employed to obtain the quantification results in the performance of the three PSA methods. The findings indicate that the QPID method demonstrated the optimal performance, followed by the charge comparison method, and concluding with the RPID method. In consideration of the complexity of the algorithm, the charge comparison method with the optimized windows introduced in QPID is preferable to our scheme. A crystal array and a silicon detector array, which can compose a telescope system, are under construction at the experimental terminals of the HIAF-HIRIBL facility. The present study demonstrates that the CsI(Tl) detector alone can achieve a better result in identifying the incident particles with a charge number Z less than 3. This capability enables the restriction of silicon detectors utilization to the forward polar angle region, with the larger polar angle region covered by CsI(Tl) detectors during some specific experimental studies. CsI(Tl) detectors have been demonstrated to exhibit sufficient performance in identifying light charged particles.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , T10007
The identification methods of light charged particles with a CsI(Tl) detector based on the pulse shape analysis technique
Four types of pulse shape analysis (PSA) algorithms were examined with the objective of identifying the light charged particles utilizing a CsI(Tl) detector. These included the fall time comparison method, the charge comparison method, the Reconstructive Particle IDentification (RPID) method, and the Quick Particle IDentification (QPID) method. The beam test with the CsI(Tl) detector demonstrates that the charge comparison method, the RPID method, and the QPID method exhibit satisfactory capacities in identifying the incident particles of hydrogen and helium isotopes. Conversely, the fall time comparison method exhibits suboptimal performance in particle identification. The linearization process was employed to obtain the quantification results in the performance of the three PSA methods. The findings indicate that the QPID method demonstrated the optimal performance, followed by the charge comparison method, and concluding with the RPID method. In consideration of the complexity of the algorithm, the charge comparison method with the optimized windows introduced in QPID is preferable to our scheme. A crystal array and a silicon detector array, which can compose a telescope system, are under construction at the experimental terminals of the HIAF-HIRIBL facility. The present study demonstrates that the CsI(Tl) detector alone can achieve a better result in identifying the incident particles with a charge number Z less than 3. This capability enables the restriction of silicon detectors utilization to the forward polar angle region, with the larger polar angle region covered by CsI(Tl) detectors during some specific experimental studies. CsI(Tl) detectors have been demonstrated to exhibit sufficient performance in identifying light charged particles.
- Open Access
- 10 September 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (11)
Muonium Spectroscopy as a Quantum Sensor for Axion Dark Matter
High-intensity muon beams could enable a muonium-based axion search through resonant quantum transitions between hyperfine states. Combining theoretical calculations with simulation results, we demonstrate that such a muonium-based experimental approach could complement and tighten constraints on the axion-muon coupling beyond existing limits from the muon g − 2 measurement over the axion mass range of 18 – 130 μ eV . These results establish a new spectroscopic channel in muonium that enables searches for axion and axionlike particle dark matter.
- 10 September 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (11)
Open AccessMuonium Spectroscopy as a Quantum Sensor for Axion Dark Matter
High-intensity muon beams could enable a muonium-based axion search through resonant quantum transitions between hyperfine states. Combining theoretical calculations with simulation results, we demonstrate that such a muonium-based experimental approach could complement and tighten constraints on the axion-muon coupling beyond existing limits from the muon g − 2 measurement over the axion mass range of 18 – 130 μ eV . These results establish a new spectroscopic channel in muonium that enables searches for axion and axionlike particle dark matter.
- Open Access
- 2 July 2026
- Published by Elsevier in Science Bulletin
- Vol. 71 (16) , 4099-4102
Discovery of isotope 153Hf near the proton drip line via isochronous mass spectrometry: extending the nuclear landscape with HIAF
- 2 July 2026
- Published by Elsevier in Science Bulletin
- Vol. 71 (16) , 4099-4102
Open AccessDiscovery of isotope 153Hf near the proton drip line via isochronous mass spectrometry: extending the nuclear landscape with HIAF
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Scale Model-Driven Engineering Validation of Discrete Coil Technology (DCT) for CEE Superconducting Dipole
The CSR External-target Experiment (CEE) is a large-scale spectrometer under construction at Lanzhou's Heavy Ion Research Facility (HIRFL), focusing on studying nuclear matter's phase structure (high baryon density) and equation of state (supra-saturation densities). Its key component is a large-acceptance dipole magnet: 0.5 T central field, 5% homogeneity within a 1m×1.2 m×0.9 m aperture (for detectors). An innovative superconducting magnet design is proposed: coil-dominant type with racetrack-shaped discrete conductors, plus a warm iron yoke (enhances central field, reduces stray field). The magnet is 3.4 m long, 2.7 m high, 4.3 m wide. Coils use 19-strand cables, supported by keels to withstand electromagnetic force. Due to its novel structure, the magnet scheme poses great technical challenges. Therefore, a 1/6-scale prototype magnet was developed to comprehensively verify the scheme's feasibility via the scaled-down prototype. This paper will detail the development process of this scaled-down magnet prototype.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Scale Model-Driven Engineering Validation of Discrete Coil Technology (DCT) for CEE Superconducting Dipole
The CSR External-target Experiment (CEE) is a large-scale spectrometer under construction at Lanzhou's Heavy Ion Research Facility (HIRFL), focusing on studying nuclear matter's phase structure (high baryon density) and equation of state (supra-saturation densities). Its key component is a large-acceptance dipole magnet: 0.5 T central field, 5% homogeneity within a 1m×1.2 m×0.9 m aperture (for detectors). An innovative superconducting magnet design is proposed: coil-dominant type with racetrack-shaped discrete conductors, plus a warm iron yoke (enhances central field, reduces stray field). The magnet is 3.4 m long, 2.7 m high, 4.3 m wide. Coils use 19-strand cables, supported by keels to withstand electromagnetic force. Due to its novel structure, the magnet scheme poses great technical challenges. Therefore, a 1/6-scale prototype magnet was developed to comprehensively verify the scheme's feasibility via the scaled-down prototype. This paper will detail the development process of this scaled-down magnet prototype.
- Open Access
- 2 April 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (8)
Investigation of light output uniformity improvement in dual-end readout CsI(Tl) scintillator bars
- 2 April 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (8)
Open AccessInvestigation of light output uniformity improvement in dual-end readout CsI(Tl) scintillator bars
- 9 March 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 113 (11)
Temperature-dependent nuclear quantum effects in muoniated benzene: A path integral molecular dynamics study
- 9 March 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 113 (11)
Temperature-dependent nuclear quantum effects in muoniated benzene: A path integral molecular dynamics study