Behzad Bahraminejad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Behzad Bahraminejad has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Maryam Mohd Isa
Universiti Putra Malaysia
6 shared publications - Shahnor Basri
Faculty of Manufacturing Engineering, University Malaysia Pahang, Malaysia
6 shared publications Zarida Hambali
Faculty of Medical Science, University Putra Malaysia, Serdang, Malaysia
3 shared publications- Ali Khademhosseini
Terasaki Institute for Biomedical Innovation, Los Angeles, CA, USA
2 shared publications Hamid Reza Ebrahimi
2 shared publications- Jiuhui Han
Tianjin Key Laboratory of Advanced Porous Functional Materials Institute For New Energy Materials & Low‐Carbon Technologies School of Materials Science and Engineering Tianjin University of Technology Tianjin China
2 shared publications
Latest Publications
- 19 October 2017
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 40 (8) , 689-698
Numeral-source, high-resolution, staircase multi-level inverter with low number of conducting switches
A high-resolution, staircase-output multi-level inverter is proposed in this paper. The topology can provide high number of levels with low number of sources and conducting switches. A 1-2-7 source version of the proposed topology can generate 21 levels with 3 DC sources, 11 total bidirectional switches, and 3 conducting switches plus 3 conducting diodes. The topology can also be expanded horizontally to achieve higher resolution; a 1-2-7-14-source version of this new topology can generate 49 levels with 4 DC sources, 15 total bidirectional switches, and 3 conducting switches plus 3 conducting diodes. Providing modularity also leads to easy maintenance in the proposed topology. The feasibility of the inverter is investigated through experimental results. In comparison with other inverters, the proposed inverter can function with 25% fewer conducting switches while providing the same resolution. A stand-alone application under renewables with low output voltage is the goal application.
- 19 October 2017
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 40 (8) , 689-698
Numeral-source, high-resolution, staircase multi-level inverter with low number of conducting switches
A high-resolution, staircase-output multi-level inverter is proposed in this paper. The topology can provide high number of levels with low number of sources and conducting switches. A 1-2-7 source version of the proposed topology can generate 21 levels with 3 DC sources, 11 total bidirectional switches, and 3 conducting switches plus 3 conducting diodes. The topology can also be expanded horizontally to achieve higher resolution; a 1-2-7-14-source version of this new topology can generate 49 levels with 4 DC sources, 15 total bidirectional switches, and 3 conducting switches plus 3 conducting diodes. Providing modularity also leads to easy maintenance in the proposed topology. The feasibility of the inverter is investigated through experimental results. In comparison with other inverters, the proposed inverter can function with 25% fewer conducting switches while providing the same resolution. A stand-alone application under renewables with low output voltage is the goal application.
- 1 February 2017
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 88, 41-47
Macroporous mesh of nanoporous gold in electrochemical monitoring of superoxide release from skeletal muscle cells
- 1 February 2017
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 88, 41-47
Macroporous mesh of nanoporous gold in electrochemical monitoring of superoxide release from skeletal muscle cells
- 1 September 2016
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 414, 55-58
Synthesis, characterization and gas sensitivity investigation of Ni0.5Zn0.5Fe2O4 nanoparticles
- 1 September 2016
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 414, 55-58
Synthesis, characterization and gas sensitivity investigation of Ni0.5Zn0.5Fe2O4 nanoparticles
- 23 June 2016
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 1 (7) , 921-928
Online Monitoring of Superoxide Anions Released from Skeletal Muscle Cells Using an Electrochemical Biosensor Based on Thick-Film Nanoporous Gold
- 23 June 2016
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 1 (7) , 921-928
Online Monitoring of Superoxide Anions Released from Skeletal Muscle Cells Using an Electrochemical Biosensor Based on Thick-Film Nanoporous Gold
- 1 February 2016
- Published by American Scientific Publishers in Sensor Letters
- Vol. 14 (2) , 205-209
Highly Sensitive Ni0.5Cu0.5Fe2O4 Nano Particles as an Ethanol Gas Sensor
Nickel copper ferrite (Ni0.5Cu0.5Fe2O4) nano particles with diameters less than 50 nm were prepared by co-precipitation method. Structure and magnetic properties of the fabricated samples were studied by X-ray diffraction (XRD), transmission electron microscopy (TEM) and alternating gradient-force magnetometery (AGFM). The X-ray analysis presented the formation of nickel copper ferrite phase. The average crystallite size for nickel zinc ferrite powder, calculated by Debye-Scherer formula, was found 15 nm. TEM image confirmed the formation of nanostructure. The predicted formula and real formula of Ni0.5Cu0.5Fe2O4 were very closed in XRF analysis. According to AGFM experiments, disk sample had the better magnetization property. Sensitivity properties of this ferrite were studied. Sensitivity of the prototype gas sensor to six short-chain target gases was investigated in this study including, ethanol, methanol, acetone, acetonitrile, ammonia and carbon tetrachloride. Among these Target gases, the ethanol had the best sensitivity performance.
- 1 February 2016
- Published by American Scientific Publishers in Sensor Letters
- Vol. 14 (2) , 205-209
Highly Sensitive Ni0.5Cu0.5Fe2O4 Nano Particles as an Ethanol Gas Sensor
Nickel copper ferrite (Ni0.5Cu0.5Fe2O4) nano particles with diameters less than 50 nm were prepared by co-precipitation method. Structure and magnetic properties of the fabricated samples were studied by X-ray diffraction (XRD), transmission electron microscopy (TEM) and alternating gradient-force magnetometery (AGFM). The X-ray analysis presented the formation of nickel copper ferrite phase. The average crystallite size for nickel zinc ferrite powder, calculated by Debye-Scherer formula, was found 15 nm. TEM image confirmed the formation of nanostructure. The predicted formula and real formula of Ni0.5Cu0.5Fe2O4 were very closed in XRF analysis. According to AGFM experiments, disk sample had the better magnetization property. Sensitivity properties of this ferrite were studied. Sensitivity of the prototype gas sensor to six short-chain target gases was investigated in this study including, ethanol, methanol, acetone, acetonitrile, ammonia and carbon tetrachloride. Among these Target gases, the ethanol had the best sensitivity performance.
- 1 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 550-555
High-resolution numeral-based multilevel inverter with low number of conducting switches for low-voltage PV applications
A new high-resolution staircase-output multilevel inverter for low voltage PV applications is proposed in this paper. The proposed topology can provide high number of levels with low number of sources and conducting switches. A 1-2-7-14-source version of this new topology can generate 49 levels with 4 sources, 30 total switches and 6 1 conducting switches. The topology also can be expanded horizontally and vertically to achieve higher resolution. In addition, a multiwinding-based variant of the topology is proposed with lower number of switches and one DC source. Experimental results show the feasibility of the inverter. At last, the proposed topology was compared with other staircase topologies considering important parameters in low voltage PV systems.
- 1 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 550-555
High-resolution numeral-based multilevel inverter with low number of conducting switches for low-voltage PV applications
A new high-resolution staircase-output multilevel inverter for low voltage PV applications is proposed in this paper. The proposed topology can provide high number of levels with low number of sources and conducting switches. A 1-2-7-14-source version of this new topology can generate 49 levels with 4 sources, 30 total switches and 6 1 conducting switches. The topology also can be expanded horizontally and vertically to achieve higher resolution. In addition, a multiwinding-based variant of the topology is proposed with lower number of switches and one DC source. Experimental results show the feasibility of the inverter. At last, the proposed topology was compared with other staircase topologies considering important parameters in low voltage PV systems.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 148-151
Gas type identification at constant concentration level by system identification technique
The purpose of this paper is to explore the ability of the system identification technique in detecting a specific gas at a constant concentration level by a single sensor. Metal oxide semiconductor (MOS) gas sensor is used due to its wide range of applicability in gas monitoring systems. Using the Batch computer method, 115 outputs were recorded with sampling time of 0.57 Sec at a concentration level of 2600 (ppm) for Methanol, Ethanol, and Betanol gases. Applying the estimated model, each gas was successfully distinguished.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 148-151
Gas type identification at constant concentration level by system identification technique
The purpose of this paper is to explore the ability of the system identification technique in detecting a specific gas at a constant concentration level by a single sensor. Metal oxide semiconductor (MOS) gas sensor is used due to its wide range of applicability in gas monitoring systems. Using the Batch computer method, 115 outputs were recorded with sampling time of 0.57 Sec at a concentration level of 2600 (ppm) for Methanol, Ethanol, and Betanol gases. Applying the estimated model, each gas was successfully distinguished.
- Open Access
- 23 April 2012
- Published by Institute of Advanced Engineering and Science in International Journal of Information and Network Security (IJINS)
- Vol. 1 (1) , 28-36
Synthetic Feature Transformation with RBF neural network to improve the Intrusion Detection System Accuracy and Decrease Computational Costs
With the rapidly growing and wide spread use of computer networks, the number of new attacks and malicious has grown widely. Intrusion Detection System can identify the attacks and protect the systems successfully. But, performance of IDS related to feature extraction and selection phases. In this paper, we proposed new feature transformation to overcome this weakness. For this aim, we combined LDA and PCA as feature transformation and RBF Neural Network as classifier. RBF Neural Net (RBF-NN) has a high speed in classification and low computational costs. Hence, the proposed method can be used in real time systems. Our results on KDDCUP99 shows our proposed method have better performance related to other feature transformation methods such as LDA, PCA, Kernel Discriminant Analysis (KDA) and Local Linear Embedding (LLE).
- 23 April 2012
- Published by Institute of Advanced Engineering and Science in International Journal of Information and Network Security (IJINS)
- Vol. 1 (1) , 28-36
Open AccessSynthetic Feature Transformation with RBF neural network to improve the Intrusion Detection System Accuracy and Decrease Computational Costs
With the rapidly growing and wide spread use of computer networks, the number of new attacks and malicious has grown widely. Intrusion Detection System can identify the attacks and protect the systems successfully. But, performance of IDS related to feature extraction and selection phases. In this paper, we proposed new feature transformation to overcome this weakness. For this aim, we combined LDA and PCA as feature transformation and RBF Neural Network as classifier. RBF Neural Net (RBF-NN) has a high speed in classification and low computational costs. Hence, the proposed method can be used in real time systems. Our results on KDDCUP99 shows our proposed method have better performance related to other feature transformation methods such as LDA, PCA, Kernel Discriminant Analysis (KDA) and Local Linear Embedding (LLE).
- 1 March 2012
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 77, 28-34
Artificial neural network modeling of biomarkers to infer characteristics of contaminant exposure in Clarias gariepinus
- 1 March 2012
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 77, 28-34
Artificial neural network modeling of biomarkers to infer characteristics of contaminant exposure in Clarias gariepinus
- 25 January 2011
- Published by Emerald Publishing in Sensor Review
- Vol. 31 (1) , 26-31
Hydrogen detection in organic gas mixtures based on analyzing the transient response
Purpose – The purpose of this paper is to explore the ability of capillary-attached gas sensor (CGS) in detecting components of gas mixtures, including a volatile organic gas and hydrogen in a wide range of concentrations. Design/methodology/approach – Diverse feature extraction and classification techniques were employed to analyze the response of CGS when applied to different mixtures. Findings – It was observed that the response of CGS to the above gas mixtures could be distinguishable. While evaluating the results of the classification technique, it was implied that hydrogen, in the presence of the volatile organic gases, could be detected perfectly by analyzing the response of the CGS. Separating techniques, which yielded a high rate of classification, were used to separate mixtures containing hydrogen and organic gases from other organic gas mixtures without hydrogen. Originality/value – The results presented in this paper prove the ability of CGS in fabricating an olfactory machine for analyzing the components of gas mixtures.
- 25 January 2011
- Published by Emerald Publishing in Sensor Review
- Vol. 31 (1) , 26-31
Hydrogen detection in organic gas mixtures based on analyzing the transient response
Purpose – The purpose of this paper is to explore the ability of capillary-attached gas sensor (CGS) in detecting components of gas mixtures, including a volatile organic gas and hydrogen in a wide range of concentrations. Design/methodology/approach – Diverse feature extraction and classification techniques were employed to analyze the response of CGS when applied to different mixtures. Findings – It was observed that the response of CGS to the above gas mixtures could be distinguishable. While evaluating the results of the classification technique, it was implied that hydrogen, in the presence of the volatile organic gases, could be detected perfectly by analyzing the response of the CGS. Separating techniques, which yielded a high rate of classification, were used to separate mixtures containing hydrogen and organic gases from other organic gas mixtures without hydrogen. Originality/value – The results presented in this paper prove the ability of CGS in fabricating an olfactory machine for analyzing the components of gas mixtures.