Gillian M. Gunning
Research Subjects
Gillian M. Gunning has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Bruce P. Murphy
Trinity Centre for Bioengineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland
3 shared publications - Denis Vivien
Normandie Univ, UNICAEN, INSERM, U1237, PhIND "Physiopathology and Imaging of Neurological Disorders", Institut Blood and Brain @ Caen-Normandie, Cyceron
1 shared publication - Emmanuel Touzé
Université Caen Normandie - UNICAEN, INSERM, PhIND (Physiopathology and Imaging of Neurological Disorders), Institut BBM@C (Brain, Blood and Memory @ Caen Normandie), Cyceron, Caen, France
1 shared publication Kevin McArdle
Neuravi Ltd, Galway, Ireland
1 shared publication- Laurent Pierot
Radiology, University Hospital Reims, Reims, France
1 shared publication - M. Gilvarry
Cerenovus, Galway, Ireland
1 shared publication
Latest Publications
- Open Access
- 14 May 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (6) , 1049-1053
Fast Stent Retrieval Improves Recanalization Rates of Thrombectomy: Experimental Study on Different Thrombi
BACKGROUND AND PURPOSE: About 20% of patients with acute ischemic stroke due to large-artery occlusion do not achieve recanalization with mechanical thrombectomy. We aimed to determine whether the speed of retrieval of the stent retriever influences the efficacy in removing different clot types. MATERIALS AND METHODS: Sixty mechanical thrombectomies were performed using an in vitro pulsatile cerebrovascular circulation model with controlled pressure and flow rate. Experiments were dichotomized into fast and slow retrieval using a wedging technique, in which the stent retriever and distal catheter are retrieved together. We used 3 different clot types: erythrocyte-rich, fibrin-rich, and friable clots. Primary end points were complete (TICI 3) and successful (TICI 2b–3) recanalizations. Secondary measures were distal and new territory embolizations. RESULTS: Fast retrieval was more frequently associated with complete (RR = 1.83; 95% CI, 1.12–2.99) and successful recanalization (RR = 1.50; 95% CI, 1.03–2.19) than slow retrieval, without a difference in distal embolization (RR = 0.75; 95% CI, 0.29–1.90). There were no emboli in a new territory. The advantage of fast retrieval over slow retrieval differed according to the clot composition, with a stronger effect with fibrin-rich clots with regard to complete (RR = 4.00; 95% CI, 1.11–14.35; Pint = .04) and successful (Pint = .10) recanalization. CONCLUSIONS: In our experimental model, a fast removal improved recanalization rates of mechanical thrombectomy, especially in the case of fibrin-rich clots. An in vivo confirmation is warranted to see whether our findings can have an impact in clinical practice.
- 14 May 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (6) , 1049-1053
Open AccessFast Stent Retrieval Improves Recanalization Rates of Thrombectomy: Experimental Study on Different Thrombi
BACKGROUND AND PURPOSE: About 20% of patients with acute ischemic stroke due to large-artery occlusion do not achieve recanalization with mechanical thrombectomy. We aimed to determine whether the speed of retrieval of the stent retriever influences the efficacy in removing different clot types. MATERIALS AND METHODS: Sixty mechanical thrombectomies were performed using an in vitro pulsatile cerebrovascular circulation model with controlled pressure and flow rate. Experiments were dichotomized into fast and slow retrieval using a wedging technique, in which the stent retriever and distal catheter are retrieved together. We used 3 different clot types: erythrocyte-rich, fibrin-rich, and friable clots. Primary end points were complete (TICI 3) and successful (TICI 2b–3) recanalizations. Secondary measures were distal and new territory embolizations. RESULTS: Fast retrieval was more frequently associated with complete (RR = 1.83; 95% CI, 1.12–2.99) and successful recanalization (RR = 1.50; 95% CI, 1.03–2.19) than slow retrieval, without a difference in distal embolization (RR = 0.75; 95% CI, 0.29–1.90). There were no emboli in a new territory. The advantage of fast retrieval over slow retrieval differed according to the clot composition, with a stronger effect with fibrin-rich clots with regard to complete (RR = 4.00; 95% CI, 1.11–14.35; Pint = .04) and successful (Pint = .10) recanalization. CONCLUSIONS: In our experimental model, a fast removal improved recanalization rates of mechanical thrombectomy, especially in the case of fibrin-rich clots. An in vivo confirmation is warranted to see whether our findings can have an impact in clinical practice.
- Top Cited Papers
- 2 January 2017
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 10 (1) , 34-38
Clot friction variation with fibrin content; implications for resistance to thrombectomy
Background Despite significant advancements in the procedural efficacy of mechanical thrombectomy in patients with ischemic stroke in recent years, there still remains a portion of the population that does not achieve good recanalization. The reasons for this may be varied. We hypothesized that static friction between the clot and the vessel, or catheter wall might contribute to the difficulty in removing the clot. Objective To determine if there is a relationship between clot composition and the resistance to sliding (friction) which might contribute to resistance to clot removal. Methods As clot composition can vary significantly, we investigated five different types of clot in order to measure their respective frictional properties. To do this, a custom-made testing apparatus was created, consisting of various replaceable low-friction surfaces on which the clots could be placed. The surface was then gradually tilted until the clots began to slide; the angle at which this occurred is related to the coefficient of friction of the clots. The experiment was repeated on a bovine aortic surface in order to confirm the results. Results We found that fibrin-rich clots (20%. This result was confirmed by repeating the experiment on a bovine aortic surface as a representation of the interaction between clots and the arterial wall. Conclusions The friction properties of clots were found to be related to the content ratio of fibrin to red blood cells. Future imaging techniques that could show fibrin and red blood cell content might help us to predict the ‘stickiness’ of a clot.
- 2 January 2017
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 10 (1) , 34-38
Top Cited PapersClot friction variation with fibrin content; implications for resistance to thrombectomy
Background Despite significant advancements in the procedural efficacy of mechanical thrombectomy in patients with ischemic stroke in recent years, there still remains a portion of the population that does not achieve good recanalization. The reasons for this may be varied. We hypothesized that static friction between the clot and the vessel, or catheter wall might contribute to the difficulty in removing the clot. Objective To determine if there is a relationship between clot composition and the resistance to sliding (friction) which might contribute to resistance to clot removal. Methods As clot composition can vary significantly, we investigated five different types of clot in order to measure their respective frictional properties. To do this, a custom-made testing apparatus was created, consisting of various replaceable low-friction surfaces on which the clots could be placed. The surface was then gradually tilted until the clots began to slide; the angle at which this occurred is related to the coefficient of friction of the clots. The experiment was repeated on a bovine aortic surface in order to confirm the results. Results We found that fibrin-rich clots (20%. This result was confirmed by repeating the experiment on a bovine aortic surface as a representation of the interaction between clots and the arterial wall. Conclusions The friction properties of clots were found to be related to the content ratio of fibrin to red blood cells. Future imaging techniques that could show fibrin and red blood cell content might help us to predict the ‘stickiness’ of a clot.
- 1 September 2015
- Published by Elsevier in Acta Biomaterialia
- Vol. 24, 193-200
Characterisation of the fatigue life, dynamic creep and modes of damage accumulation within mitral valve chordae tendineae
- 1 September 2015
- Published by Elsevier in Acta Biomaterialia
- Vol. 24, 193-200
Characterisation of the fatigue life, dynamic creep and modes of damage accumulation within mitral valve chordae tendineae
- 1 January 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (2) , 334-340
Determination of the tensile mechanical properties of the segmented mitral valve annulus
- 1 January 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (2) , 334-340
Determination of the tensile mechanical properties of the segmented mitral valve annulus