M. Gilvarry
M. Gilvarry has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Denis Vivien
Normandie Univ, UNICAEN, INSERM, U1237, PhIND "Physiopathology and Imaging of Neurological Disorders", Institut Blood and Brain @ Caen-Normandie, Cyceron
1 shared publication - Emmanuel Touzé
Université Caen Normandie - UNICAEN, INSERM, PhIND (Physiopathology and Imaging of Neurological Disorders), Institut BBM@C (Brain, Blood and Memory @ Caen Normandie), Cyceron, Caen, France
1 shared publication - Gillian M. Gunning
Neuravi/Cerenovus (M.M., G.G., M. Gilvarry), Galway, Ireland
1 shared publication - Laurent Pierot
Radiology, University Hospital Reims, Reims, France
1 shared publication M Mirza
Neuro Thromboembolic Initiative
1 shared publication- Mahmood Mirza
Medical Affairs, Cerenovus, Galway, Ireland
1 shared publication
Latest Publications
- Open Access
- 24 August 2021
- Published by BMJ
- Vol. 13 (Suppl 2) , A26.2-A26
EP64 Systematic review and analysis of pre-clinical side-by-side comparisons of EmboTrap versus Solitaire performance
Introduction The first pass effect (FPE) has gained acceptance as the new measure of success for mechanical thrombectomy. Lacking clinical trials that compare devices, in-vitro studies may be useful to investigate the impact of device designs to FPE. Aim of the Study To systematically compare EmboTrap performance using side-by-side generated in-vitro comparative studies Methods A systematic review of literature for pre-clinical data containing in-vitro thrombectomies was performed in Pubmed. Articles were included if multiple devices including EmboTrap were used in the same models, techniques, and blood clot analogs. Individualized data were extracted, and a pooled analysis was performed. Comparisons of recanalization success between stent-retrievers and different clot types were performed using two-way analysis of variance (ANOVA) and a two-sample t-test with Tukey’s honestly significance. Results An initial search revealed 277 articles, 4 articles met the inclusion criteria. Only EmboTrap and Solitaire devices were consistently used in all 4 articles, limiting comparisons to only these two devices. Three articles described outcomes as first-pass complete clot removal, while one article allowed up to 3 passes, for a total of 210 thrombectomy attempts. Of the three clot types studied, friable and tough clots were recanalized less effectively than standard clots (p0.05). EmboTrap had better recanalization outcomes than Solitaire (pConclusions Pre-clinical data, particularly from combined independent studies, can provide insightful comparisons between device designs. References Machi P, Jourdan F, Ambard D, et al. Experimental evaluation of stent retrievers´ mechanical properties and effectiveness. J Neurointerv Surg 2017 Mar;9(3):257–263. Chueh JY, Marosfoi MG, Brooks OW, et al. Novel distal emboli protection technology: the EmboTrap. Interv Neurol 2017 Oct;6(3–4):268–276. Kaneko N, Komuro Y, Yokota H, et al. Stent retrievers with segmented design improve the efficacy of thrombectomy in tortuous vessels. J Neurointerv Surg 2019 Feb;11(2):119–122. Soize S, Pierot L, Mirza M, et al. Fast stent retrieval improves recanalization rates of thrombectomy: experimental study on different thrombi. AJNR Am J Neuroradiol 2020 Jun;41(6):1049–1053. Disclosure MM, RM, and MG are employees of Cerenovus.
- 24 August 2021
- Published by BMJ
- Vol. 13 (Suppl 2) , A26.2-A26
Open AccessEP64 Systematic review and analysis of pre-clinical side-by-side comparisons of EmboTrap versus Solitaire performance
Introduction The first pass effect (FPE) has gained acceptance as the new measure of success for mechanical thrombectomy. Lacking clinical trials that compare devices, in-vitro studies may be useful to investigate the impact of device designs to FPE. Aim of the Study To systematically compare EmboTrap performance using side-by-side generated in-vitro comparative studies Methods A systematic review of literature for pre-clinical data containing in-vitro thrombectomies was performed in Pubmed. Articles were included if multiple devices including EmboTrap were used in the same models, techniques, and blood clot analogs. Individualized data were extracted, and a pooled analysis was performed. Comparisons of recanalization success between stent-retrievers and different clot types were performed using two-way analysis of variance (ANOVA) and a two-sample t-test with Tukey’s honestly significance. Results An initial search revealed 277 articles, 4 articles met the inclusion criteria. Only EmboTrap and Solitaire devices were consistently used in all 4 articles, limiting comparisons to only these two devices. Three articles described outcomes as first-pass complete clot removal, while one article allowed up to 3 passes, for a total of 210 thrombectomy attempts. Of the three clot types studied, friable and tough clots were recanalized less effectively than standard clots (p0.05). EmboTrap had better recanalization outcomes than Solitaire (pConclusions Pre-clinical data, particularly from combined independent studies, can provide insightful comparisons between device designs. References Machi P, Jourdan F, Ambard D, et al. Experimental evaluation of stent retrievers´ mechanical properties and effectiveness. J Neurointerv Surg 2017 Mar;9(3):257–263. Chueh JY, Marosfoi MG, Brooks OW, et al. Novel distal emboli protection technology: the EmboTrap. Interv Neurol 2017 Oct;6(3–4):268–276. Kaneko N, Komuro Y, Yokota H, et al. Stent retrievers with segmented design improve the efficacy of thrombectomy in tortuous vessels. J Neurointerv Surg 2019 Feb;11(2):119–122. Soize S, Pierot L, Mirza M, et al. Fast stent retrieval improves recanalization rates of thrombectomy: experimental study on different thrombi. AJNR Am J Neuroradiol 2020 Jun;41(6):1049–1053. Disclosure MM, RM, and MG are employees of Cerenovus.
- Open Access
- 14 May 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (6) , 1049-1053
Fast Stent Retrieval Improves Recanalization Rates of Thrombectomy: Experimental Study on Different Thrombi
BACKGROUND AND PURPOSE: About 20% of patients with acute ischemic stroke due to large-artery occlusion do not achieve recanalization with mechanical thrombectomy. We aimed to determine whether the speed of retrieval of the stent retriever influences the efficacy in removing different clot types. MATERIALS AND METHODS: Sixty mechanical thrombectomies were performed using an in vitro pulsatile cerebrovascular circulation model with controlled pressure and flow rate. Experiments were dichotomized into fast and slow retrieval using a wedging technique, in which the stent retriever and distal catheter are retrieved together. We used 3 different clot types: erythrocyte-rich, fibrin-rich, and friable clots. Primary end points were complete (TICI 3) and successful (TICI 2b–3) recanalizations. Secondary measures were distal and new territory embolizations. RESULTS: Fast retrieval was more frequently associated with complete (RR = 1.83; 95% CI, 1.12–2.99) and successful recanalization (RR = 1.50; 95% CI, 1.03–2.19) than slow retrieval, without a difference in distal embolization (RR = 0.75; 95% CI, 0.29–1.90). There were no emboli in a new territory. The advantage of fast retrieval over slow retrieval differed according to the clot composition, with a stronger effect with fibrin-rich clots with regard to complete (RR = 4.00; 95% CI, 1.11–14.35; Pint = .04) and successful (Pint = .10) recanalization. CONCLUSIONS: In our experimental model, a fast removal improved recanalization rates of mechanical thrombectomy, especially in the case of fibrin-rich clots. An in vivo confirmation is warranted to see whether our findings can have an impact in clinical practice.
- 14 May 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (6) , 1049-1053
Open AccessFast Stent Retrieval Improves Recanalization Rates of Thrombectomy: Experimental Study on Different Thrombi
BACKGROUND AND PURPOSE: About 20% of patients with acute ischemic stroke due to large-artery occlusion do not achieve recanalization with mechanical thrombectomy. We aimed to determine whether the speed of retrieval of the stent retriever influences the efficacy in removing different clot types. MATERIALS AND METHODS: Sixty mechanical thrombectomies were performed using an in vitro pulsatile cerebrovascular circulation model with controlled pressure and flow rate. Experiments were dichotomized into fast and slow retrieval using a wedging technique, in which the stent retriever and distal catheter are retrieved together. We used 3 different clot types: erythrocyte-rich, fibrin-rich, and friable clots. Primary end points were complete (TICI 3) and successful (TICI 2b–3) recanalizations. Secondary measures were distal and new territory embolizations. RESULTS: Fast retrieval was more frequently associated with complete (RR = 1.83; 95% CI, 1.12–2.99) and successful recanalization (RR = 1.50; 95% CI, 1.03–2.19) than slow retrieval, without a difference in distal embolization (RR = 0.75; 95% CI, 0.29–1.90). There were no emboli in a new territory. The advantage of fast retrieval over slow retrieval differed according to the clot composition, with a stronger effect with fibrin-rich clots with regard to complete (RR = 4.00; 95% CI, 1.11–14.35; Pint = .04) and successful (Pint = .10) recanalization. CONCLUSIONS: In our experimental model, a fast removal improved recanalization rates of mechanical thrombectomy, especially in the case of fibrin-rich clots. An in vivo confirmation is warranted to see whether our findings can have an impact in clinical practice.