GSGoutam Kumar Samanta

Goutam Kumar Samanta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Goutam Kumar Samanta has a total of 123 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Classical‐to‐Quantum Transfer of Geometric Phase for Controlled Manipulation of Quantum State

    by Vimlesh Kumar, Chahat Kaushik, M. Ebrahim‐Zadeh, C. M. Chandrashekar, G. K. Samanta

    The geometric phase, arising from the cyclic/non‐cyclic evolution of a polarization state of light, is typically measured using interferometric methods that often introduce unwanted dynamic phase contributions. Here, we present a phase measurement technique based on the quantum correlation of pair photons to measure the geometric phase of a classical beam without any dynamic phase contribution. The transfer of the geometric phase of the classical pump beam onto polarization‐entangled pair photons generated via spontaneous parametric down‐conversion in a Sagnac interferometer scheme enables easy control over the quantum state. Characterization of the quantum states reveals that the geometric phase of the pump beam controls the coincidence counts, entanglement visibility, Bell's parameter, quantum‐state tomography, and fidelity, in close agreement with theoretical predictions. We observe sinusoidal modulation of Bell's parameter and state fidelity with changes in the geometric phase, resulting in transitions between orthogonal Bell states and Bell‐like maximally entangled states. Our results establish the geometric phase of the classical pump as a tunable parameter for quantum state control, offering a compact, passive platform for phase manipulation in quantum photonic systems, enabling geometric‐phase‐controlled quantum operations, and compensating for the unwanted phase acquired by the quantum state during propagation.

  • Paraxial spin-induced vortex generation in epsilon-near-zero materials

    by Aloke Jana, Anirban Ghosh, Shyamal Guchhait, Ravi K. Saripalli, N. Apurv Chaitanya, Nirmalya Ghosh, Subhasish Dutta Gupta, G. K. Samanta

    Spin–orbit interactions (SOI) of light have emerged as a prominent area of research in nanophotonics, whereas epsilon-near-zero (ENZ) materials are gaining attention for their ability to interact with electromagnetic fields peculiarly. Integrating these two, we show that homogeneous ENZ thin films enable efficient spin-to-vortex conversion even under paraxial illumination. Using a generalized angular-spectrum formalism and experimental verification, we demonstrate that circularly polarized light incident on an indium-tin-oxide slab generates a second-order vortex in the cross-circular channel. Moreover, for elliptically deformed Gaussian excitation, the spin-induced vortex undergoes astigmatic splitting into two generic vortices. In contrast, a Bessel–Gaussian annulus with phase asymmetry from a tilted axicon produces a similar vortex splitting accompanied by a spin-dependent rotation of the double-core vortex pattern. These findings, combined with the intrinsic nonlinearity of ENZ materials, highlight their potential as a versatile platform to explore SOI effects across linear and nonlinear regimes.

  • Non-interferometric measurement of geometric phase through stimulated second harmonic generation

    by Chahat Kaushik, Anirban Ghosh, S. Chaitanya Kumar, Kavita Devi, Ritwick Das, G. K. Samanta

    The geometric phase (GP), arising from the evolution of states like polarization on the Poincaré sphere, is conventionally measured using interferometry. However, the interferometric techniques often suffer from instability, causing GP to be masked by dynamic phase contributions. Here, we propose a non-interferometric approach based on stimulated second harmonic generation (S-SHG) for GP measurement. Using a continuous-wave pump and two-stage SHG, we achieved S-SHG in the second crystal using the seed SHG and undepleted pump of the first crystal. By exploiting the phase-sensitive nature of the S-SHG, we mapped the GP, arising from the rotation of the half-waveplate, placed between two suitably oriented quarter-waveplates, onto the S-SHG power to measure GP with a sensitivity better than 26 μW/mrad. The measured GP value agrees with Jones' calculus and interferometric measurement. Furthermore, we found that the sensitivity of GP measurement is high for phase-modulation to pump beam and a high S-SHG amplification at low seed power, establishing the suitability of the S-SHG scheme for imaging biological samples with low illumination, avoiding thermal damage. Such a generic scheme can be implemented using any nonlinear crystal and laser (cw to ultrafast), establishing its potential for various applications.


  • A perspective on 25 years of advances as reported in the Journal of Optics

    by Andrew Forbes, Mohamed Swilliam, Kayn A Forbes, Yijie Shen, Chao He, Shuyuan Xiao, Jörg B Götte, Goutam K Samanta, Tatsuki Tahara, Boris Malomed, et al.

    In this perspective, the Editorial Board of the J. Opt. reflects on the past 25 years of the journal. The advances reported in journal have shaped the progress of diverse fields, from fundamental advances in optics to applications with optics as a key ingredient. The journal’s scope has seen it capture progress in several emergent fields, for instance, structured light covering orbital angular momentum, spatio-temporal solitons, topologies in light, singular optics and nonparaxial light. Reports include advances in optical devices, such as digital micromirror devices, metasurfaces and integrated photonics, as well as novel photonic materials based on nanophotonics. Application-based research includes super-resolution imaging, digital holography and nonlinear optics. We select key papers from across diverse disciplines to showcase the scope of the journal and the impact it has had on the wider community.


  • Beam-splitter-free, device-independent, high bit-rate, quantum random number generator based on temporal and spatial correlations of heralded single-photons

    by Ayan Kumar Nai, Amritash Sharma, Vimlesh Kumar, Sandeep Singh, Shreya Mishra, C. M. Chandrashekar, G. K. Samanta

    Spontaneous parametric down-conversion (SPDC), an inherently random quantum process, produces pair photons with strong temporal and spatial correlations due to energy and momentum conservation, and acts as the key for quantum random number generation (QRNG). Standard QRNG methods primarily use temporal correlations with beam splitters, limiting bit rates. However, due to spatial correlation, the pair photons in non-collinear phase-matched SPDC-setup appear at diametrically opposite points on an annular spatial distribution. Therefore, exploring the temporal correlation between the spatially correlated photon-pairs from different sections of the annual ring can directly lead to device-independent, multi-bit QRNG at a high rate, eliminating the need of a physical object such as a beam splitter. As a proof-of-concept, we report on high-bit-rate QRNG by using spatial correlation of photon-pairs by sectioning the SPDC ring of a non-collinear, degenerate, high-brightness source and temporal correlation between the diametrically opposite sections. Dividing the annular ring of the high-brightness photon-pair source based on a 20-mm-long, type-0 phase-matched, periodically poled KTP crystal into four sections, recording the timestamp of the coincidences (window of 1 ns) between photons from diametrically opposite sections and assigning bits (0 and 1), we extracted 90 × 106 raw bits over 27.7 s at a pump power of 17 mW. Using minimum entropy evaluation, we determined an extraction ratio of over 95 % for raw bits. Further, using Toeplitz matrix-based post-processing, we developed QRNG with bit rate of 3 Mbps, passing all NIST 800-22 and TestU01 test suites. The generic scheme shows the possibility of further enhancement of bit rate with more sectioning of the SPDC ring.


  • Dead-zone-free single-beam atomic magnetometer based on free-induction-decay of Rb atoms

    by Shrey Mehta, G. K. Samanta, Raghwinder Singh Grewal

    Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.


  • Open Access

    Fast measurement of group index variation with optimum precision using Hong–Ou–Mandel interferometry

    by Sandeep Singh, Vimlesh Kumar, G. K. Samanta

    Hong–Ou–Mandel (HOM) interferometry has emerged as a valuable means for quantum sensing applications, particularly in measuring physical parameters that influence the relative optical delay between photon pairs. Unlike classical techniques, HOM-based quantum sensors offer higher resolution due to the intrinsic dispersion cancellation property of correlated photon pairs. Due to the use of single photons, HOM-based quantum sensors typically involve a large integration time to acquire the signal and subsequent post-processing for high-resolution measurements, restricting their use for real-time operations. Based on our understanding of the relationship between measurement resolution and the gain medium length that produces photon pairs, we report here on the development of an HOM-based quantum sensor for high-precision group index measurements. Using a 1 mm long periodically poled KTP (PPKTP) crystal for photon-pair generation, we have measured the group index with a precision of ∼6.75×10−6 per centimeter of sample length at an integration time of 100 ms, surpassing the previous reports by 400%. Typically, the measurement range reduces with the increase in the resolution. However, using a novel scheme compensating photon delay due to group index changes stepwise with an optical delay stage, we have measured the group index variation of PPKTP crystal over a range of 3.5 × 10−3 for a temperature change from 25 to 200 °C, corresponding to an optical delay adjustment of ∼200 μm while maintaining the same precision (∼6.75×10−6 per centimeter of sample length). The current results establish the usefulness of HOM-interferometer-based quantum sensors for fast, precise, and long-range measurements in various applications, including quantum optical coherence tomography.


  • Harnessing nonlinear frequency upconversion of Talbot effect with flexible Talbot lengths

    by Harshith Bachimanchi, Saumya J. Sarkar, Majid Ebrahim-Zadeh, Goutam K. Samanta

    We report on a simple experimental scheme demonstrating nonlinear frequency upconversion of the Talbot effect with controllable Talbot lengths at high conversion efficiency. Using a microlens array (MLA) as an array illuminator at 1064 nm onto a 1.2-mm-thick BiBO crystal, we have observed the second harmonic Talbot effect in green at 532 nm with a Talbot length twice that of the pump Talbot length. However, the Talbot length is constant for fixed parameters of the periodic object and the laser wavelength. With the formulation of a suitable theoretical framework, we have implemented a generic experimental scheme based on the Fourier transformation technique to independently control the Talbot lengths of the MLA in both the pump and the second harmonic, overcoming the stringent dependence of MLA parameters on the self-images. Deploying the current technique, we have been able to tune the Talbot lengths from z T = 26 cm to z T = 62.4 cm in the pump and z T = 12.4 cm to z T = 30.8 cm in the second harmonic, respectively. The single pass conversion efficiency of the Talbot images is 2.91% W−1, an enhancement of a factor of 106 as compared to the previous reports. This generic experimental scheme can be used to generate long-range self-images of periodic structures and also to program desired Talbot planes at required positions at both pump and upconverted frequency to avoid any mechanical constraints of experiments.


  • Open Access

    Dynamically tunable broadband output coupling of optical oscillators based on non-cyclic geometric phase mirror

    by Chahat Kaushik, A. Aadhi, Anirban Ghosh, R. P. Singh, S. Dutta Gupta, M. Ebrahim-Zadeh, G. K. Samanta

    We present a uniquely versatile and efficient mirror system capable of real-time fine-tuning in reflection and transmission properties across a broad wavelength range and at a high optical power. Leveraging the principles of the non-cyclic geometric phase (GP) acquired by the clockwise and counterclockwise beams of the Sagnac interferometer satisfying the anti-resonant condition on propagation through the quarter-wave plate, half-wave plate, and quarter-wave plate combination having fast axes oriented at 45° (fixed), θ (variable), and −45° (fixed) with respect to the vertical, respectively, our mirror system offers dynamic transmission control across 0–100% without the need for realignment. Notably, the GP-based mirror (GP-mirror) preserves the polarization state of the reflected beam, making it ideal for polarization-sensitive applications. The wavelength insensitivity of the GP enables seamless operation of the mirror across a wide wavelength range. As a proof-of-principle, we use the GP-mirror as the output coupler of a continuous-wave, green-pumped, doubly resonant optical parametric oscillator (DRO) based on a 30-mm-long MgO:sPPLT crystal and obtain stable operation at high powers over a wide wavelength tuning range. For a pump power of 5 W, the DRO provides an output power of 2.45 W at an extraction efficiency as high as 49% when operated at optimum output coupling. The DRO shows a maximum pump depletion of 89% and delivers an optimum output power across a tuning range ≥90 nm. The demonstrated concept offers a promising approach for advancing the capabilities and control of coherent optical sources tunable across different spectral regions and in all time scales from continuous-wave to ultrafast femtosecond domain.


  • Near‐Video Frame Rate Quantum Sensing Using Hong–Ou–Mandel Interferometry

    by Sandeep Singh, Vimlesh Kumar, Varun Sharma, Daniele Faccio, G. K. Samanta

    Hong–Ou–Mandel (HOM) interference, bunching of two indistinguishable photons on a balanced beam‐splitter, has emerged as a promising tool for quantum sensing. There is a need for wide spectral‐bandwidth photon pairs (for high‐resolution sensing) with high brightness (for fast sensing). Here, the generation of photon‐pairs with flexible spectral‐bandwidth even using single‐frequency, continuous‐wave diode laser enabling high‐precision, real‐time sensing is showed. Using 1‐mm‐long periodically‐poled KTP crystal, degenerate, photon‐pairs with spectral‐bandwidth of 163.42±1.68 nm are produced resulting in a HOM‐dip width of 4.01±0.04 m to measure a displacement of 60 nm, and sufficiently high brightness to enable the measurement of vibrations with amplitude of 205 ± 0.75 nm and frequency of 8 Hz. Fisher‐information (FI) and maximum likelihood estimation enables optical delay measurements as small as 4.97 nm with precision (Cramér–Rao bound) and accuracy of 0.89 and 0.54 nm, respectively, therefore showing HOM sensing capability for real‐time, precision‐augmented, in‐field quantum sensing applications.