OPOliver Paul

Oliver Paul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oliver Paul has a total of 204 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Galvanomagnetic Transport in Magnetic Sensors Reinterpreted Using Two Instead of Three Kinetic Coefficients

    by Oliver Paul

    This paper pertains to the topic of galvanomagnetic phenomena arising in semiconductor-based magnetic sensors and to the operation of such devices. An alternative formulation of the nonlinear galvanomagnetic transport equation is derived. Traditionally this equation has involved terms for isotropic conduction, the Hall effect, and the planar Hall effect, each modulated by its own magnetic-flux-density-dependent kinetic coefficient. It is shown that the first and third terms can be jointly expressed using a single symmetric transport coefficient matrix, while the Hall effect is expressed using an antisymmetric matrix. Thereby, conduction in samples of cubic crystal structure exposed to a magnetic field becomes spheroidally anisotropic. Conduction along the magnetic field vector remains unchanged, while that in the perpendicular plane is reduced. In four-contact magnetic sensors, output signal components due to the symmetric transport matrix are canceled by the current-spinning method, leaving only the Hall voltage caused by the Hall effect. The inverse transport equation relying on the resistivity tensor is fully analogous to the conductivity-based formulation. Graphical interpretations of resulting phenomena are derived in both resistivity and conductivity-based pictures. The former is suited for thin devices such as planar Hall sensors intended for quantifying the out-of-plane component of the magnetic flux density, while the latter is relevant for columnar devices, i.e., idealized versions of vertical Hall sensors designed for determining in-plane components. The conclusions of this work are subject to the assumptions of a parabolic, isotropic conduction band and an energy-dependent relaxation time in the relaxation time approximation of the Boltzmann equation.


  • Open Access

    Model Complexity Reduction in Bayesian Sensor Calibration and Its Relation to Principal Component Analysis

    by Tim Samuel Winter, Oliver Paul

    Calibration is a costly, necessary part of sensor manufacturing. Bayesian sensor calibration leverages prior knowledge in the form of a sample of sensor response functions from a sensor ensemble such as a fabrication lot. Based on a response model with M parameters, it allows to infer the measurand of interest and its predictive uncertainty from output signals of specimens of the ensemble after their lean calibration with a small number N of measurements, possibly with N < M. This paper answers the question of whether it is possible to reduce model complexity by choosing models with parameter number M < M, while guaranteeing a required predictive accuracy. Reduced models are obtained by projections of a high-dimensional model, termed full model, onto a subspace of its parameter space. An I-optimality-based loss function implementing the Bayesian calibration approach is derived. For given N and ˜M, it allows to find an optimal reduced model and, at the same time, the optimal experimental design of the calibration. The approach is applied to 48 specimens of a CMOS Hall sensor system cross-sensitive to temperature and mechanical stress. Starting from an 11-parameter full model, reduced models with M = 2, 4, and 5 are identified for calibration routines with N = 2, 4, and 6 measurements, respectively. Despite the significantly smaller parameter numbers, the resulting rms predictive uncertainties of 102 μT, 77.0 μT, and 64.8 μT, respectively, are increased by less than 1% from the full-model values. A general conclusion is that model order reduction in the present Bayesian framework invariably entails an uncertainty increase, similar to principal component analysis.


  • TMR Angle Sensor Calibration with 3D Misalignment Compensation

    by Tim Samuel Winter, Martin Cornils, Laurent Osberger, Oliver Paul

    This paper introduces an efficient tilt calibration and compensation method for tunnel magnetoresistive (TMR) angle sensors. The approach models the sensor's response and, using Bayesian design of experiments, optimizes calibration conditions to minimize predictive uncertainty. A symmetric arrangement of six calibration field vectors with strong out-of-plane components is found to ensure optimal calibration. The cross-sensitivity of the inferred azimuthal angle of applied 3D $B$ fields to sensor misalignment is thereby efficiently suppressed. For $B$ fields with polar angles of 45°, rms angle errors are reduced from about 2.6°to about 0.12. In addition, the standard deviation of the residual angle error under random sensor misalignment is reduced by factors between 3 and 12.


  • Effective Compensation of the Piezo-Hall Effect in CMOS-integrated 3D Hall Sensors

    by Anja Fleck, Martin Cornils, Laurent Osberger, Oliver Paul

    A highly effective method based on half-blind calibration is demonstrated for the dynamic compensation of the mechanical stress cross-sensitivity of a CMOS-integrated 3D Hall sensor system caused by the piezo-Hall effect. The system combines a Hall plate with two orthogonal vertical Hall sensors. For the first time, the use of dedicated stress sensors is avoided by exploiting a piezoresistive signal from the Hall plate. The combination of this signal with the output signals of the three Hall sensors in respective polynomial sensor response models allows to infer the three corresponding magnetic induction components largely cleared of the piezo-Hall effect due to an in-plane uniaxial normal stress. Model parameters are extracted at 25°C by simultaneously applying stress between 0 MPa and -90 MPa and 3D magnetic inductions up to 30 mT. As a result, the residual angular resolution of the system is reduced from about 4° to below 0.10 in the investigated stress range.


  • Open Access

    Issue Information

    by Hisao Chairperson, Vice Chairperson, Hiroyuki Nishikawa, Narendra Ahuja, Frede Blaabjerg, Dushan Boroyevich, Hsiao‐Dong Chiang, Kukjin Chun, Dominique Collard, Gille Delapierre, et al.

  • Open Access

    Bayesian Sensor Calibration of a CMOS-Integrated Hall Sensor Against Thermomechanical Cross-Sensitivities

    by Moritz Berger, Christian Schott, Oliver Paul

    For the first time, Bayesian sensor calibration is used to identify efficient calibration procedures for a sensor cross-sensitive to 2 parasitic influences. The object under study is a thermomechanically cross-sensitive sensor system for determining the magnetic induction B . The packaged system comprises a Hall sensor, a stress sensor, and a temperature sensor. The three sensor signals are combined in a polynomial sensor response model with 11 parameters to determine B compensated for offset and cross-sensitivities. For the calibration, sensors are exposed to mechanical stress values between 0 and -68MPa, temperatures between -40 and 100 °C, and B values between and 25mT. A sample of 35 sensors serves to extract the prior model parameter distribution of their fabrication run. Bayesian experimental design is applied to identify sets of 2 to 8 optimal calibration conditions under I-optimality and G-optimality. Bayesian inference then allows to obtain the posterior model parameter distribution of any uncalibrated sensor from the same run. Any such sensor is thereby turned into a B measuring device with individually quantified accuracy. The method was successfully applied to 15 validation sensors. In the case of I-optimality, the median root-mean-square (rms) σ values of the ±1σ confidence intervals for the extracted B values were found to be 113 to 71 μT after near-I-optimal calibrations based on 2 to 8 measurements, respectively. Over the entire range of temperature and mechanical stress and for applied | B |≤25mT, corresponding experimentally determined medians of the rms deviations between predicted and applied B values were found to be 89 to 71 μT. Analogous observations apply to G-optimality. In short, Bayesian calibration made it possible to obtain functional B sensors of known accuracy with significantly fewer calibration measurements than model parameters. This was enabled by prior knowledge collected by the thorough characterization of 35 prior-generating specimens.


  • New Wafer-Level Fabrication of Ultrathin Silicon Insertion Shuttles for Flexible Neural Implants

    by Kirti Sharma, Christian Boehler, Maria Asplund, Oliver Paul, Patrick Ruther

    This paper reports a novel, cost-effective process for the fabrication of ultrathin silicon (Si) shuttles applied as insertion tools for highly flexible polyimide (PI) neural implants. The process exploits the so-called etching before grinding (EBG) process established to realize Si-based neural probes of the Michigan style. In this study, EBG is combined for the first time with a subsequent deep reactive ion etch (DRIE) process applied on the wafer-level. The innovative approach allows to realize insertion shuttles with a base thickness > 50 µm using wafer grinding and to reliably thin down the slender shuttle shanks (width ≥ 35 µm) to thicknesses as small as 15 µm using DRIE. The backgrinding liquid wax applied during wafer grinding enables the safe release of the delicate shuttle structures from their carrier wafer using isopropanol. Flexible, 15-µm-thin neural probes made from PI are precisely aligned and temporarily bonded to the custom-designed insertion shuttles applying polyethylene glycol (PEG) and reliably deployed into cortical tissue.


  • Open Access

    Bayesian Sensor Calibration

    by Moritz Berger, Christian Schott, Oliver Paul

    The calibration of multisensor systems can cause significant costs in terms of time and resources, in particular when cross-sensitivities to parasitic influences are to be compensated. Successful calibration ensures the trustworthy subsequent operation of a sensor system, guaranteeing that one or several measurands of interest can be inferred from its output signals with specified uncertainty. As the present study shows, this goal can be reached by reduced calibration procedures with fewer calibration conditions than parameters needed to model the device response. This is achieved using Bayesian inference by combining calibration data of a sensor system with statistical prior information about the ensemble to which it belongs. Optimal reduced sets of calibration conditions are identified by the method of Bayesian experimental design. The method is demonstrated on a Hall-temperature sensor system whose nonlinear response model requires seven parameters in the temperature range between –30 °C and 150 °C and for magnetic field values B between –25mT and 25mT. For the prior, a multivariate normal distribution of the model parameters is acquired using 14 specimens of the sensor ensemble. I-optimal calibration at one, two, and three temperatures reduces the rms standard deviation of B inferred from sensor output signals from 203 μT before calibration down to 78 μT, 41 μT, and 34 μT, respectively. Similar conclusions apply to G-optimal calibration. The paper describes how to implement the Bayesian prior acquisition, inference, and experimental design. The proposed approach can help save resources and cut costs in sensor calibration.


  • Open Access

    Single‐layer tri‐state switching as an economical method to address linear light‐emitting diode arrays

    by Eric Klein, Patrick Ruther, Oliver Paul

    This paper reports on new schemes based on the concept of tri‐state switching for routing linear arrays of light‐emitting diodes (LEDs) on slim substrates. The schemes use a minimal number of wires in single‐metal planar technologies, where wires are not allowed to cross. They have in common that the number of LEDs, N L , addressable by N W wires is given by N L = 4 N W − 6. The designs are built on a family of hierarchically interconnected structures with (2 n +1 − 2) LEDs and (2 n −1 + 1) wires, for positive integers n . A process termed linear expansion straightforwardly extends them to arbitrary values of N W and adds 4 LEDs with each additional wire. Expressions for series resistances and the average wire length normalized to the array length are derived. In hierarchical designs, the average normalized wire length asymptotically approaches 7/12 for large n . A matrix formulation graphically elucidates the new interconnection schemes.


  • Intracortical probe arrays with silicon backbone and microelectrodes on thin polyimide wings enable long-term stable recordings in vivo

    by Antje Kilias, Yu-Tao Lee, Ulrich P Froriep, Charlotte Sielaff, Dominik Moser, Tobias Holzhammer, Ulrich Egert, Weileun Fang, Oliver Paul, Patrick Ruther

    Objective. Recording and stimulating neuronal activity across different brain regions requires interfacing at multiple sites using dedicated tools while tissue reactions at the recording sites often prevent their successful long-term application. This implies the technological challenge of developing complex probe geometries while keeping the overall footprint minimal, and of selecting materials compatible with neural tissue. While the potential of soft materials in reducing tissue response is uncontested, the implantation of these materials is often limited to reliably target neuronal structures across large brain volumes. Approach. We report on the development of a new multi-electrode array exploiting the advantages of soft and stiff materials by combining 7- µ m-thin polyimide wings carrying platinum electrodes with a silicon backbone enabling a safe probe implantation. The probe fabrication applies microsystems technologies in combination with a temporal wafer fixation method for rear side processing, i.e. grinding and deep reactive ion etching, of slender probe shanks and electrode wings. The wing-type neural probes are chronically implanted into the entorhinal-hippocampal formation in the mouse for in vivo recordings of freely behaving animals. Main results. Probes comprising the novel wing-type electrodes have been realized and characterized in view of their electrical performance and insertion capability. Chronic electrophysiological in vivo recordings of the entorhinal-hippocampal network in the mouse of up to 104 days demonstrated a stable yield of channels containing identifiable multi-unit and single-unit activity outperforming probes with electrodes residing on a Si backbone. Significance. The innovative fabrication process using a process compatible, temporary wafer bonding allowed to realize new Michigan-style probe arrays. The wing-type probe design enables a precise probe insertion into brain tissue and long-term stable recordings of unit activity due to the application of a stable backbone and 7- µ m-thin probe wings provoking locally a minimal tissue response and protruding from the glial scare of the backbone.