DKDong Hyun Kim

Dong Hyun Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dong Hyun Kim has a total of 100 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bioinspired High-Degrees of Freedom Soft Robotic Glove for Restoring Versatile and Comfortable Manipulation

    by Dong Hyun Kim, Yechan Lee, Hyung-Soon Park

    The human hand is one of the most complex and compact grippers that has arisen as a product of natural genetic engineering; it is highly versatile, as it handles power and precision tasks. Since proper contact points and force directions are required to ensure versatility and secure a stable grip on an object, there must be a large workspace and controllable tip force directions for the digits. Although they are important, many individuals with neuromuscular diseases experience loss of these features. Thus, we propose a high-degree-of-freedom (DOF) soft robotic glove inspired by the anatomical features of human hands. The mechanism for adjusting the position and force direction of each tip is based on the structure of the extrinsic and intrinsic muscle–tendon units. The large thumb workspace was achieved by assisting opposition/reposition and flexion/extension to enable various grasping postures. A bidirectional actuation control mechanism with a cable-actuated agonist and an elastomer antagonist increased the assisted DOF and maintained compactness. The kinematic and kinetic performances of our device were evaluated by performing tests with eight stroke survivors. The thumb workspace increased by 43%, 207%, and 248% in the distal–proximal, dorsal–palmar, and radial–ulnar directions, respectively. The pinching shear force decreased by 54% and 45% for the nonthumb digits and thumb, respectively. These device-assisted improvements allowed objects to be stably grasped and manipulated in various postures. The novel device can assist individuals with impaired hand function to improve their grasping performance. Clinical Research Information Service (CRIS) Registration Number: KCT0004855.


  • Cooperative Hand Therapy via a Soft, Wearable, and Unilateral Telerobotic System

    by Dong Hyun Kim, Yechan Lee, Hyung-Soon Park

    Functional rehabilitation of the hand is a complex and difficult process involving a large number of degrees of freedom (DOFs). Soft wearable hand-rehabilitation robots have assisted hand movements with a compact structural design, but effective rehabilitation requires an intuitive control scheme that can manage many DOFs and incorporate interaction with an occupational therapist, which has yet to be developed for this type of device. Thus, we present a soft wearable unilateral telerobotic system that enables various grasping tasks and cooperative interaction between the patient and therapist. The presented system consists of a sensor glove that measures the hand postures of the occupational therapist and a soft robotic glove that assists 4-DOF movements of the patient's hand, including adjustments of the interjoint coordination of the finger and 2-DOF movements of the thumb (flexion/extension and opposition/reposition). The soft robotic glove effectuates hand movements based on the measurements from the sensor glove. A telerobotic impedance-control scheme provides intuitive guidance of various hand postures, along with a fingertip-force vector. The feasible workspace and control performance of the system were evaluated on a healthy recruit and a poststroke patient. The presented system allowed the therapist to increase the patient's thumb workspace by 400% in palmar-dorsal direction and to control the fingertip-force direction at −30°∼10° range by enabling control of interjoint coordination of the proximal-interphalangeal and metacarpophalangeal joints. These features facilitate patients to perform various postures for stable object grasping. The presented rehabilitation system is suitable for noncontact telehealthcare that facilitates patient–therapist interactions.


  • Anthropomorphic Prosthetic Hand Inspired by Efficient Swing Mechanics for Sports Activities

    by Mun Hyeok Chang, Dong Hyun Kim, Sang-Hun Kim, Yechan Lee, Seongyun Cho, Hyung-Soon Park, Kyu-Jin Cho

    Swinging-generating high impact by maximizing the speed of motion-is essential in sports activities. However, designing prosthetic hands suitable for swinging is still a challenge. Herein, in this article, we propose a swing-dedicated prosthetic hand that adopts the anatomical features of humans for an efficient swing. Our design, inspired by the joint arthrokinematics and tendon routing of fingers, enables a diagonal power “squeeze” grip robust to impact while increasing the reach of the clubhead. The swing speed is further increased by radio/ulnar deviation of the wrist and its nonlinear stiffness change achieved by the passive clutch mechanism. We evaluated our prosthetic hand through golf and found that it sustained high impact with diagonal grip, and clubhead speed increased by 19% at 90 r/min, with the radio/ulnar deviation nonlinearly correlated with arm angle. Our prosthetic hand design will contribute to improving amputees’ quality of life by allowing them to participate in sports activities.


  • Development of a Biomimetic Extensor Mechanism for Restoring Normal Kinematics of Finger Movements Post-Stroke

    by Dong Hyun Kim, Sang Wook Lee, Hyung Soon Park

    Cable-driven devices for hands allow compact and lightweight design that could provide various functional movements. However, for many patients post-stroke, cable-driven devices produce nonphysiologic movements, such as metacarpophalangeal joint hyperextension, due to their abnormal passive joint impedance. In this study, we developed a novel bio-inspired device mimicking the anatomy of the extensor mechanism of the human finger, which can be tuned for individuals to provide `subject-specific' assistance to achieve physiological movement patterns. We first evaluated the proposed design via mathematical modeling and computer simulation. Its performance was then tested experimentally with twenty-four subjects, including six healthy and eighteen chronic stroke survivors. We determined the loading condition of the device from the experimental identification of passive joint impedance of each subject before device use. Our results showed that the proposed design could achieve improved spatiotemporal coordination of finger movements compared to conventional cable-driven design by providing `subject-specific' assistance based on identified passive stiffness values of each subject. We also identified a significant (negative) correlation between the metacarpophalangeal joint stiffness and the intrinsic exotendon loading level across subjects. The proposed system can restore normal movement patterns for patients with different types of impairments, which were previously found important in improving rehabilitative outcomes.


  • Open Access

    Improving Kinematic Accuracy of Soft Wearable Data Gloves by Optimizing Sensor Locations

    by Dong Hyun Kim, Sang Wook Lee, Hyung-Soon Park

    Bending sensors enable compact, wearable designs when used for measuring hand configurations in data gloves. While existing data gloves can accurately measure angular displacement of the finger and distal thumb joints, accurate measurement of thumb carpometacarpal (CMC) joint movements remains challenging due to crosstalk between the multi-sensor outputs required to measure the degrees of freedom (DOF). To properly measure CMC-joint configurations, sensor locations that minimize sensor crosstalk must be identified. This paper presents a novel approach to identifying optimal sensor locations. Three-dimensional hand surface data from ten subjects was collected in multiple thumb postures with varied CMC-joint flexion and abduction angles. For each posture, scanned CMC-joint contours were used to estimate CMC-joint flexion and abduction angles by varying the positions and orientations of two bending sensors. Optimal sensor locations were estimated by the least squares method, which minimized the difference between the true CMC-joint angles and the joint angle estimates. Finally, the resultant optimal sensor locations were experimentally validated. Placing sensors at the optimal locations, CMC-joint angle measurement accuracies improved (flexion, 2.8° ± 1.9°; abduction, 1.9° ± 1.2°). The proposed method for improving the accuracy of the sensing system can be extended to other types of soft wearable measurement devices.


  • Open Access

    Front & Back Matter

    by Sven-Erik Dahlén, Dae Suk Kim, Dong Hyun Kim, Hemin Lee, Hyunjoong Jee, Young Lee, Min-Youl Chang, Taek-Jong Kwak, Chul-Hong Kim, Young-Ah Shin, et al.

  • Open Access

    Associate Editor

    by Sven-Erik Dahlén, Dae Suk Kim, Dong Hyun Kim, Hemin Lee, Hyunjoong Jee, Young Lee, Min-Youl Chang, Taek-Jong Kwak, Chul-Hong Kim, Young-Ah Shin, et al.

  • Open Access

    Associate Editor

    by Sven‐Erik Dahlén, Jee Hung Kim, Dong Hyun Kim, Hemin Lee, Hyunjoong Jee, Young Kyung Lee, Min-Youl Chang, Taek-Jong Kwak, Chul-Hong Kim, Young-Ah Shin, et al.

  • Open Access

    Associate Editor

    by Sven‐Erik Dahlén, Jee Hung Kim, Dong Hyun Kim, Hemin Lee, Hyunjoong Jee, Young Kyung Lee, Min-Youl Chang, Taek-Jong Kwak, Chul-Hong Kim, Young-Ah Shin, et al.