Alena Vadimovna Shchelokova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alena Vadimovna Shchelokova has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
- Alexey Petrovich Slobozhanyuk
School of Physics and Engineering, ITMO University, Saint Petersburg, Russia
30 shared publications P. A. Belov
University of Information Technology Mechanics and Optics
9 shared publicationsPavel A. Belov
Department of Nanophotonics and Metamaterials, ITMO University 1 , St. Petersburg 197101, Russia
7 shared publications- Viktor Puchnin
ITMO University
6 shared publications - Andrew G. Webb
C. J. Gorter MRI Centre, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands
5 shared publications I. V. Melchakova
University of Information Technology Mechanics and Optics
5 shared publications
Latest Publications
- Open Access
- 24 September 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 97 (1) , 403-413
Optimal Transmission Performance of Quadrature Wireless Resonators at 3 T
Purpose: To demonstrate a method for optimizing the efficiency of wireless resonators using tailored excitation from a dual‐transmit birdcage coil (BC), and to present the design and experimental investigation of a quadrature resonator for 3 T breast MRI application. Methods: A double‐mode quadrature resonator was designed to enhance both orthogonal components of the field in a 3 T BC. Flip‐angle maps measurements were performed on phantom to validate the predicted transmit efficiency gains. Numerical simulations were performed on a human voxel model to demonstrate the ability to optimize the field and SAR metrics. Results: Experiments confirmed that each linear polarization was enhanced by the resonator, yielding a 4.5‐fold improvement in the transmit efficiency compared with the reference BC under conventional circularly polarized (CP) excitation. The optimal excitation was derived and validated experimentally, leading to an additional 2% increase in transmit efficiency. Simulations revealed that the resonator provided a 5.9‐fold (left breast) and 5.2‐fold (right breast) improvement in SAR efficiency under conventional CP excitation. Tailored excitations further increased SAR efficiency by 15% (left breast) and 31% (right breast), approaching a 7‐fold improvement compared to the reference BC. Conclusion: A double‐mode quadrature resonator was demonstrated for 3 T MRI. Combined with dual‐transmit BC, it enabled focusing and significantly improved transmit and SAR efficiency. Our analytical model allowed the derivation of tailored BC excitation to approach the theoretical performance limit of wireless resonators.
- 24 September 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 97 (1) , 403-413
Open AccessOptimal Transmission Performance of Quadrature Wireless Resonators at 3 T
Purpose: To demonstrate a method for optimizing the efficiency of wireless resonators using tailored excitation from a dual‐transmit birdcage coil (BC), and to present the design and experimental investigation of a quadrature resonator for 3 T breast MRI application. Methods: A double‐mode quadrature resonator was designed to enhance both orthogonal components of the field in a 3 T BC. Flip‐angle maps measurements were performed on phantom to validate the predicted transmit efficiency gains. Numerical simulations were performed on a human voxel model to demonstrate the ability to optimize the field and SAR metrics. Results: Experiments confirmed that each linear polarization was enhanced by the resonator, yielding a 4.5‐fold improvement in the transmit efficiency compared with the reference BC under conventional circularly polarized (CP) excitation. The optimal excitation was derived and validated experimentally, leading to an additional 2% increase in transmit efficiency. Simulations revealed that the resonator provided a 5.9‐fold (left breast) and 5.2‐fold (right breast) improvement in SAR efficiency under conventional CP excitation. Tailored excitations further increased SAR efficiency by 15% (left breast) and 31% (right breast), approaching a 7‐fold improvement compared to the reference BC. Conclusion: A double‐mode quadrature resonator was demonstrated for 3 T MRI. Combined with dual‐transmit BC, it enabled focusing and significantly improved transmit and SAR efficiency. Our analytical model allowed the derivation of tailored BC excitation to approach the theoretical performance limit of wireless resonators.
- 31 July 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (1)
Tunable control of the magnetic near-field pattern in MRI via concentric split-ring resonators
- 31 July 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (1)
Tunable control of the magnetic near-field pattern in MRI via concentric split-ring resonators
- Open Access
- 23 June 2026
- Published by Springer Nature in Research Square
RF coil for human head MRI with high sensitivity in peripheral area
Objective: This study proposes a cortex radiofrequency (RF) coil based on a modified birdcage resonator with a shape conformal to the human head, tuned to its highest-order mode for enhancing magnetic resonance imaging of the cerebral cortex by maximizing the signal from these regions and minimizing the signal from deeply located brain areas. Materials and methods: We design the proposed resonator for the magnetic field penetration depth of the excited highest-order mode to match the desired depth of the region of interest, achieving specific spatial filtering at the RF level, with a meander line feed to ensure selective excitation of the highest-order mode and enable the corresponding sensitivity profile. Results: Numerical simulation with a voxel model reveals that compared to the central area, the RF magnetic field is 5 times higher in the temporal lobes, 28.8 times higher in the occipital lobe, and 51.8 times higher in the frontal lobe. Experimental studies demonstrated that the SNR at the center of the brain was suppressed by a factor of 3.1 compared to the frontal lobe and by a factor of 2.4 compared to the occipital lobe. Discussion: The proposed coil effectively suppresses central brain signals while enabling high-quality MRI of the cerebral cortex.
- 23 June 2026
- Published by Springer Nature in Research Square
Open AccessRF coil for human head MRI with high sensitivity in peripheral area
Objective: This study proposes a cortex radiofrequency (RF) coil based on a modified birdcage resonator with a shape conformal to the human head, tuned to its highest-order mode for enhancing magnetic resonance imaging of the cerebral cortex by maximizing the signal from these regions and minimizing the signal from deeply located brain areas. Materials and methods: We design the proposed resonator for the magnetic field penetration depth of the excited highest-order mode to match the desired depth of the region of interest, achieving specific spatial filtering at the RF level, with a meander line feed to ensure selective excitation of the highest-order mode and enable the corresponding sensitivity profile. Results: Numerical simulation with a voxel model reveals that compared to the central area, the RF magnetic field is 5 times higher in the temporal lobes, 28.8 times higher in the occipital lobe, and 51.8 times higher in the frontal lobe. Experimental studies demonstrated that the SNR at the center of the brain was suppressed by a factor of 3.1 compared to the frontal lobe and by a factor of 2.4 compared to the occipital lobe. Discussion: The proposed coil effectively suppresses central brain signals while enabling high-quality MRI of the cerebral cortex.
- Open Access
- 25 February 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (4) , e70016
Improved Fetal Magnetic Resonance Imaging Using a Flexible Metasurface
Recent advancements in magnetic resonance imaging (MRI) techniques are promising for the detection of fetal abnormalities, and MRI may supplement or replace prenatal ultrasound scans in the future. In particular, the interest of scientific and medical communities in high‐field (3T) MRI continues to grow due to its improved contrast‐to‐noise and signal‐to‐noise ratios compared to clinical MRI of lower field strength (1.5T). However, 3T MRI shows more prominent dielectric artifacts due to constructive and destructive interference of standing waves inside the body at these frequencies. Here, we present a concept of passive radiofrequency shimming using metasurface‐based pads to improve image quality in fetal MRI at 3T. The proposed metasurface increases the efficiency and homogeneity of the radiofrequency magnetic field, reducing dielectric artifacts in the fetal body and brain images. We offer an ultralight and compact passive way to improve 3T imaging of fetal brain and body structures, simplifying clinical workflows and decreasing the procedure time.
- 25 February 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (4) , e70016
Open AccessImproved Fetal Magnetic Resonance Imaging Using a Flexible Metasurface
Recent advancements in magnetic resonance imaging (MRI) techniques are promising for the detection of fetal abnormalities, and MRI may supplement or replace prenatal ultrasound scans in the future. In particular, the interest of scientific and medical communities in high‐field (3T) MRI continues to grow due to its improved contrast‐to‐noise and signal‐to‐noise ratios compared to clinical MRI of lower field strength (1.5T). However, 3T MRI shows more prominent dielectric artifacts due to constructive and destructive interference of standing waves inside the body at these frequencies. Here, we present a concept of passive radiofrequency shimming using metasurface‐based pads to improve image quality in fetal MRI at 3T. The proposed metasurface increases the efficiency and homogeneity of the radiofrequency magnetic field, reducing dielectric artifacts in the fetal body and brain images. We offer an ultralight and compact passive way to improve 3T imaging of fetal brain and body structures, simplifying clinical workflows and decreasing the procedure time.
- 23 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (26)
Quasi-BIC realized in a subwavelength volumetric split ring-based resonator
In recent years, resonant structures with quasi-bound states in the continuum (quasi-BICs) have significantly expanded the practical possibilities in optics and nanophotonics. A similar mode, the so-called supercavity mode, observed in single dielectric cylinders with high permittivity and low material losses, allows achieving extremely high quality (Q) factors. Resonators supporting quasi-BICs are also promising for applications in the radio frequency range. However, creating compact structures using high-permittivity materials at frequencies below 300 MHz is challenging. This study introduces a subwavelength (∼λ/13) volumetric structure composed of two arrays of coupled split ring resonators, with one array located inside the other, which provides a supercavity mode. The numerical Q factor of this mode is increased by approximately 100 times under lossless conditions and by about 1.5 times when accounting for material losses compared to that of non-interacting modes of the two arrays. The Q factor enhancement is confirmed experimentally by near-field measurements. The advantages of the proposed resonator include its hollow cavity, ease of fabrication, and frequency tunability within the radio frequency range.
- 23 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (26)
Quasi-BIC realized in a subwavelength volumetric split ring-based resonator
In recent years, resonant structures with quasi-bound states in the continuum (quasi-BICs) have significantly expanded the practical possibilities in optics and nanophotonics. A similar mode, the so-called supercavity mode, observed in single dielectric cylinders with high permittivity and low material losses, allows achieving extremely high quality (Q) factors. Resonators supporting quasi-BICs are also promising for applications in the radio frequency range. However, creating compact structures using high-permittivity materials at frequencies below 300 MHz is challenging. This study introduces a subwavelength (∼λ/13) volumetric structure composed of two arrays of coupled split ring resonators, with one array located inside the other, which provides a supercavity mode. The numerical Q factor of this mode is increased by approximately 100 times under lossless conditions and by about 1.5 times when accounting for material losses compared to that of non-interacting modes of the two arrays. The Q factor enhancement is confirmed experimentally by near-field measurements. The advantages of the proposed resonator include its hollow cavity, ease of fabrication, and frequency tunability within the radio frequency range.
- 12 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 869-880
Flexible metasurface for improving brain imaging at 7T
Purpose: Ultra‐high field MRI offers unprecedented detail for noninvasive visualization of the human brain. However, brain imaging is challenging at 7T due to the B field inhomogeneity, which results in signal intensity drops in temporal lobes and a bright region in the brain center. This study aims to evaluate using a metasurface to improve brain imaging at 7T and simplify the investigative workflow.Methods: Two flexible metasurfaces comprising a periodic structure of copper strips and parallel‐plate capacitive elements printed on an ultra‐thin substrate were optimized for brain imaging and implemented via PCB. We considered two setups: (1) two metasurfaces located near the temporal lobes and (2) one metasurface placed near the occipital lobe. The effect of metasurface placement on the transmit efficiency and specific absorption rate was evaluated via electromagnetic simulation studies with voxelized models. In addition, their impact on signal‐to‐noise ratio (SNR) and diagnostic image quality was assessed in vivo for two male and one female volunteers.Results: Placement of metasurfaces near the regions of interest led to an increase in homogeneity of the transmit field by 5% and 10.5% in the right temporal lobe and occipital lobe for a male subject, respectively. SAR efficiency values changed insignificantly, dropping by less than 8% for all investigated setups. In vivo studies also confirmed the numerically predicted improvement in field distribution and receive sensitivity in the desired ROI.Conclusion: Optimized metasurfaces enable homogenizing transmit field distribution in the brain at 7T. The proposed lightweight and flexible structure can potentially provide MR examination with higher diagnostic value images.
- 12 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 869-880
Flexible metasurface for improving brain imaging at 7T
Purpose: Ultra‐high field MRI offers unprecedented detail for noninvasive visualization of the human brain. However, brain imaging is challenging at 7T due to the B field inhomogeneity, which results in signal intensity drops in temporal lobes and a bright region in the brain center. This study aims to evaluate using a metasurface to improve brain imaging at 7T and simplify the investigative workflow.Methods: Two flexible metasurfaces comprising a periodic structure of copper strips and parallel‐plate capacitive elements printed on an ultra‐thin substrate were optimized for brain imaging and implemented via PCB. We considered two setups: (1) two metasurfaces located near the temporal lobes and (2) one metasurface placed near the occipital lobe. The effect of metasurface placement on the transmit efficiency and specific absorption rate was evaluated via electromagnetic simulation studies with voxelized models. In addition, their impact on signal‐to‐noise ratio (SNR) and diagnostic image quality was assessed in vivo for two male and one female volunteers.Results: Placement of metasurfaces near the regions of interest led to an increase in homogeneity of the transmit field by 5% and 10.5% in the right temporal lobe and occipital lobe for a male subject, respectively. SAR efficiency values changed insignificantly, dropping by less than 8% for all investigated setups. In vivo studies also confirmed the numerically predicted improvement in field distribution and receive sensitivity in the desired ROI.Conclusion: Optimized metasurfaces enable homogenizing transmit field distribution in the brain at 7T. The proposed lightweight and flexible structure can potentially provide MR examination with higher diagnostic value images.
- 30 August 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 20 (2) , 024076
Application of Topological Edge States in Magnetic Resonance Imaging
Topological edge states in electromagnetic systems feature fascinating fundamental properties and unveil future applications based on disorder robustness and tailored localization. Despite active efforts in implementing topologically protected waveguides in two-dimensional photonic systems, applications of one-dimensional topological systems remain almost uncharted. In this Paper, we demonstrate that topological edge modes can be implemented in metamaterial-inspired volumetric resonators for clinical magnetic resonance imaging (MRI) by dimerizing a metasolenoid composed of coupled split-ring resonators to implement a one-dimensional Su-Schrieffer-Heeger model. Performing numerical simulations and experiments with a T MRI scanner, we study the associated resonance spectra of metasolenoids, their bulk and topological edge mode profiles, and signal-to-noise ratio curves. Finally, we consider the potential applications based on increased magnetic field localization at the topological edge mode compared with conventional surface coils based on single split-ring resonators and bulk modes of metasolenoids.- 30 August 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 20 (2) , 024076
Application of Topological Edge States in Magnetic Resonance Imaging
Topological edge states in electromagnetic systems feature fascinating fundamental properties and unveil future applications based on disorder robustness and tailored localization. Despite active efforts in implementing topologically protected waveguides in two-dimensional photonic systems, applications of one-dimensional topological systems remain almost uncharted. In this Paper, we demonstrate that topological edge modes can be implemented in metamaterial-inspired volumetric resonators for clinical magnetic resonance imaging (MRI) by dimerizing a metasolenoid composed of coupled split-ring resonators to implement a one-dimensional Su-Schrieffer-Heeger model. Performing numerical simulations and experiments with a T MRI scanner, we study the associated resonance spectra of metasolenoids, their bulk and topological edge mode profiles, and signal-to-noise ratio curves. Finally, we consider the potential applications based on increased magnetic field localization at the topological edge mode compared with conventional surface coils based on single split-ring resonators and bulk modes of metasolenoids.- Open Access
- 26 June 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (26)
Multi-mode metasurface as a receive coil for magnetic resonance imaging
Sensitivity and diagnostic capabilities of magnetic resonance imaging (MRI) are dictated by the design of radio frequency (RF) receive coils. They must possess several key characteristics, such as a high signal-to-noise ratio (SNR), for image quality enhancement and multiple channels for scan time reduction. Artificial materials with tailored properties, such as metasurfaces, when used as RF coils, have been shown to deliver increased image quality or scan safety. Here, we suggest and describe a multi-mode metasurface-based coil with two independent receive channels. We experimentally show that such a coil provided a higher SNR than a state-of-the-art dedicated coil. We also demonstrate the feasibility of two intrinsic independent receive channels coexisting on the same frequency, enabling parallel signal acquisition techniques.
- 26 June 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (26)
Open AccessMulti-mode metasurface as a receive coil for magnetic resonance imaging
Sensitivity and diagnostic capabilities of magnetic resonance imaging (MRI) are dictated by the design of radio frequency (RF) receive coils. They must possess several key characteristics, such as a high signal-to-noise ratio (SNR), for image quality enhancement and multiple channels for scan time reduction. Artificial materials with tailored properties, such as metasurfaces, when used as RF coils, have been shown to deliver increased image quality or scan safety. Here, we suggest and describe a multi-mode metasurface-based coil with two independent receive channels. We experimentally show that such a coil provided a higher SNR than a state-of-the-art dedicated coil. We also demonstrate the feasibility of two intrinsic independent receive channels coexisting on the same frequency, enabling parallel signal acquisition techniques.
- Open Access
- 20 May 2023
- Published by Arterialnaya Gipertenziya in Translational Medicine
- Vol. 10 (2) , 123-129
Possibilities of high-field magnetic resonance imaging (3 T) in fetal visualization using meta device
Background. Fetal and extra fetal diagnostics is currently performed using 3 Tesla magnetic-resonance imaging scanners. Examination is more informative during the third trimester of pregnancy, when fetal movements are less significant. 3 Tesla MR-images demonstrate better characteristics than 1,5 Tesla ones, however, there is a risk of heating the patient during scanning, which is especially dangerous for pregnant women.Objective. The aim of the study is to improve fetal and extrafetal structures visualization by means of developed metamaterial pad (metadevice).Design and methods. In the study, a metadevice was considered to improve fetal and extrafetal imaging in a field with magnetic induction of 3 T. 12 pregnant women between 29 and 39 weeks gestation (33,4 ± 4,8 weeks) were examined, standart magnetic resonance images of Single Shot Turbo (SST)/Fast Spin Echo(FSE)) were obtained. Standart abdomen coil was used to receive examination data. Metadevice and the coil were placed on the center of the examined area. The images were evaluated by radiologists on a 5-point Likert scale.Results of metadevice testing showed diagnostic quality improvement, increase in radio-frequency magnetic field homogeneity, decreased SAR value and reduction in body heating effect during MR-scanning.Conclusion. Metadevice-assisted MRI can lower heating risks, reduce dielectric artifacts and improve imaging quality of the fetus and extrafetal structures.
- 20 May 2023
- Published by Arterialnaya Gipertenziya in Translational Medicine
- Vol. 10 (2) , 123-129
Open AccessPossibilities of high-field magnetic resonance imaging (3 T) in fetal visualization using meta device
Background. Fetal and extra fetal diagnostics is currently performed using 3 Tesla magnetic-resonance imaging scanners. Examination is more informative during the third trimester of pregnancy, when fetal movements are less significant. 3 Tesla MR-images demonstrate better characteristics than 1,5 Tesla ones, however, there is a risk of heating the patient during scanning, which is especially dangerous for pregnant women.Objective. The aim of the study is to improve fetal and extrafetal structures visualization by means of developed metamaterial pad (metadevice).Design and methods. In the study, a metadevice was considered to improve fetal and extrafetal imaging in a field with magnetic induction of 3 T. 12 pregnant women between 29 and 39 weeks gestation (33,4 ± 4,8 weeks) were examined, standart magnetic resonance images of Single Shot Turbo (SST)/Fast Spin Echo(FSE)) were obtained. Standart abdomen coil was used to receive examination data. Metadevice and the coil were placed on the center of the examined area. The images were evaluated by radiologists on a 5-point Likert scale.Results of metadevice testing showed diagnostic quality improvement, increase in radio-frequency magnetic field homogeneity, decreased SAR value and reduction in body heating effect during MR-scanning.Conclusion. Metadevice-assisted MRI can lower heating risks, reduce dielectric artifacts and improve imaging quality of the fetus and extrafetal structures.
- 3 February 2023
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 348, 107390
Improving detection of fMRI activation at 1.5 T using high permittivity ceramics
- 3 February 2023
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 348, 107390
Improving detection of fMRI activation at 1.5 T using high permittivity ceramics