Yasmin Blunck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yasmin Blunck has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Jon O. Cleary
Department of Medicine and Radiology, University of Melbourne, Australia; Department of Radiology, Guy's and St. Thomas' NHS Foundation Trust, London, UK
5 shared publicationsLeigh A. Johnston
Department of Medicine and Radiology, University of Melbourne, Australia; Department of Biomedical Engineering, University of Melbourne, Australia
5 shared publications- Leigh A. Johnston
Graeme Clark Institute The University of Melbourne Parkville Victoria Australia
5 shared publications - Bradford Armstrong Moffat
Melbourne Brain Centre Imaging Unit, Department of Radiology, Medicine, Dentistry and Health Sciences University of Melbourne Melbourne Victoria Australia
3 shared publications - Rebecca Glarin
Melbourne Brain Centre Imaging Unit, Department of Radiology, Medicine, Dentistry and Health Sciences University of Melbourne Melbourne Victoria Australia
3 shared publications Roger J. Ordidge
Melbourne Brain Centre Imaging Unit, Department of Medicine and Radiology, The University of Melbourne, Parkville, Australia
3 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 15, e90667
Music Therapy for Reduction of Anhedonia: Protocol for a Sequential Mixed Methods Pre-Post Pilot Study
Background: The transdiagnostic symptom of anhedonia, or the loss of pleasure in previously pleasurable things, is common across several chronic physical and mental illnesses. Music therapy has been effective in treating a range of conditions associated with anhedonia, but only 3 cases have been reported that targeted increasing hedonic capacity and all relied on descriptive data (qualitative and quantitative). Functional magnetic resonance imaging (fMRI) evidence demonstrates that pleasure is associated with increased activity in the limbic system, including the anterior cingulate cortex, as well as the prefrontal cortex. As such, changes within these regions may provide objective evidence to explore how music therapy acts to reduce anhedonia symptomatology. Objective: Our primary aim is to examine the feasibility of a music therapy intervention to increase hedonic capacity among individuals with anhedonia. We also aim to examine congruence across psychometric results and interview data to generate estimates of effect size and explore participants’ qualitative experiences. In addition, we aim to identify any correspondence between these outcomes and changes in brain activity associated with reward processing during targeted fMRI tasks. This study will generate hypotheses for testing in future studies. Methods: This pilot study uses a sequential mixed methods design to first identify whether there are pre-post changes in the primary outcome measures and then to identify correlations between interview data, psychometric data, and objective measures of brain structure and functioning (fMRI). Participants were 13 adults with high cognitive function who scored within the clinical range for anhedonia on the Dimensional Anhedonia Rating Scale (DARS). Participants were engaged in a 4-month music therapy intervention developed through preliminary case studies, which involved daily independent pleasure-focused music activities and regular contact with a therapeutic guide. The fMRI data acquired include resting-state fMRI and task-based functional paradigms designed to probe musical pleasure (music listening task) and reward prediction (reversal reward learning task). Data will be analyzed using individual general linear models to identify associations with symptom improvement, as well as longitudinal changes in functioning. Results: The study received internal funding support from the University of Melbourne in September 2024. Data collection commenced in August 2025 and was concluded by mid-2026. As of September 2026, 13 participants have been recruited, and data will be analyzed by the end of 2026, with results expected to be published in 2027. Conclusions: The results of this pilot study will contribute to knowledge about the effects of this music therapy intervention on reducing anhedonia and introduce a study protocol that could be used in subsequent, more robust studies to explore potential mechanisms.
- 23 September 2026
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 15, e90667
Open AccessMusic Therapy for Reduction of Anhedonia: Protocol for a Sequential Mixed Methods Pre-Post Pilot Study
Background: The transdiagnostic symptom of anhedonia, or the loss of pleasure in previously pleasurable things, is common across several chronic physical and mental illnesses. Music therapy has been effective in treating a range of conditions associated with anhedonia, but only 3 cases have been reported that targeted increasing hedonic capacity and all relied on descriptive data (qualitative and quantitative). Functional magnetic resonance imaging (fMRI) evidence demonstrates that pleasure is associated with increased activity in the limbic system, including the anterior cingulate cortex, as well as the prefrontal cortex. As such, changes within these regions may provide objective evidence to explore how music therapy acts to reduce anhedonia symptomatology. Objective: Our primary aim is to examine the feasibility of a music therapy intervention to increase hedonic capacity among individuals with anhedonia. We also aim to examine congruence across psychometric results and interview data to generate estimates of effect size and explore participants’ qualitative experiences. In addition, we aim to identify any correspondence between these outcomes and changes in brain activity associated with reward processing during targeted fMRI tasks. This study will generate hypotheses for testing in future studies. Methods: This pilot study uses a sequential mixed methods design to first identify whether there are pre-post changes in the primary outcome measures and then to identify correlations between interview data, psychometric data, and objective measures of brain structure and functioning (fMRI). Participants were 13 adults with high cognitive function who scored within the clinical range for anhedonia on the Dimensional Anhedonia Rating Scale (DARS). Participants were engaged in a 4-month music therapy intervention developed through preliminary case studies, which involved daily independent pleasure-focused music activities and regular contact with a therapeutic guide. The fMRI data acquired include resting-state fMRI and task-based functional paradigms designed to probe musical pleasure (music listening task) and reward prediction (reversal reward learning task). Data will be analyzed using individual general linear models to identify associations with symptom improvement, as well as longitudinal changes in functioning. Results: The study received internal funding support from the University of Melbourne in September 2024. Data collection commenced in August 2025 and was concluded by mid-2026. As of September 2026, 13 participants have been recruited, and data will be analyzed by the end of 2026, with results expected to be published in 2027. Conclusions: The results of this pilot study will contribute to knowledge about the effects of this music therapy intervention on reducing anhedonia and introduce a study protocol that could be used in subsequent, more robust studies to explore potential mechanisms.
- Open Access
- 2 January 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Musical Pleasure as a Potential Mechanism for Reduction of Anhedonia Following Music Therapy: Protocol for a Pre-Post Pilot Study (Preprint)
BACKGROUND The transdiagnostic symptom of anhedonia, or the loss of pleasure in previously pleasurable things, is common across several chronic physical and mental illnesses. Music therapy has been effective in treating a range of conditions associated with anhedonia, but the precise neurobiological mechanisms underpinning music therapy’s efficacy remain unclear. One potential mechanism is musical pleasure, as a re-activator of the pleasure system. Functional Magnetic Resonance Imaging (fMRI) evidence demonstrates that pleasure is associated with increased activity of the limbic system including the anterior cingulate cortex (ACC), as well as the pre-frontal cortex. As such, changes within these regions may be one such mechanism through which music therapy acts to reduce anhedonia symptomatology. OBJECTIVE Our primary objective is to examine indicators of increased pleasure/hedonic capacity in individuals with anhedonia before and after completing a 3 month structured music therapy intervention involving daily music-based activities . We will assess whether musical pleasure mediates the relationship between music therapy and decreased anhedonia symptoms. METHODS We will pilot pre-post testing of a cohort of 9 participants who have scored as symptomatic of anhedonia using the Dimensional Anhedonia Rating Scale (DARS). We will investigate validated psychometrics tools (the DARS and Snaith-Hamilton Pleasure Scale (SHAPS)) and objective measures of brain structure and functioning (fMRI) pre- and post-intervention. fMRI data acquired will include resting-state fMRI and acquisitions during naturalistic listening to music pieces in addition to functional paradigms designed to probe musical pleasure (music listening task) and reward prediction (reversal reward learning task). Data will be analysed using individual general linear models to identify associations with symptom improvement as well as well longitudinal changes in functioning. RESULTS The study received internal funding support from the University of Melbourne in September 2024. Data collection commenced in August 2025 and will conclude by mid-2026. As of December 2025, 9 participants have been recruited, and data will be analysed by the end of 2026 with results to be published in 2027. CONCLUSIONS The results of this study will contribute to knowledge of music therapy and anhedonia and the understanding of musical pleasure as a potential mechanism for improvement. CLINICALTRIAL N/A
- 2 January 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessMusical Pleasure as a Potential Mechanism for Reduction of Anhedonia Following Music Therapy: Protocol for a Pre-Post Pilot Study (Preprint)
BACKGROUND The transdiagnostic symptom of anhedonia, or the loss of pleasure in previously pleasurable things, is common across several chronic physical and mental illnesses. Music therapy has been effective in treating a range of conditions associated with anhedonia, but the precise neurobiological mechanisms underpinning music therapy’s efficacy remain unclear. One potential mechanism is musical pleasure, as a re-activator of the pleasure system. Functional Magnetic Resonance Imaging (fMRI) evidence demonstrates that pleasure is associated with increased activity of the limbic system including the anterior cingulate cortex (ACC), as well as the pre-frontal cortex. As such, changes within these regions may be one such mechanism through which music therapy acts to reduce anhedonia symptomatology. OBJECTIVE Our primary objective is to examine indicators of increased pleasure/hedonic capacity in individuals with anhedonia before and after completing a 3 month structured music therapy intervention involving daily music-based activities . We will assess whether musical pleasure mediates the relationship between music therapy and decreased anhedonia symptoms. METHODS We will pilot pre-post testing of a cohort of 9 participants who have scored as symptomatic of anhedonia using the Dimensional Anhedonia Rating Scale (DARS). We will investigate validated psychometrics tools (the DARS and Snaith-Hamilton Pleasure Scale (SHAPS)) and objective measures of brain structure and functioning (fMRI) pre- and post-intervention. fMRI data acquired will include resting-state fMRI and acquisitions during naturalistic listening to music pieces in addition to functional paradigms designed to probe musical pleasure (music listening task) and reward prediction (reversal reward learning task). Data will be analysed using individual general linear models to identify associations with symptom improvement as well as well longitudinal changes in functioning. RESULTS The study received internal funding support from the University of Melbourne in September 2024. Data collection commenced in August 2025 and will conclude by mid-2026. As of December 2025, 9 participants have been recruited, and data will be analysed by the end of 2026 with results to be published in 2027. CONCLUSIONS The results of this study will contribute to knowledge of music therapy and anhedonia and the understanding of musical pleasure as a potential mechanism for improvement. CLINICALTRIAL N/A
- Open Access
- 4 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1878-1888
In vivo evaluation of population‐specific inversion pulses in parallel transmission
Purpose: The aim of the study was to conduct in vivo evaluation of population‐specific pulses in the context of the MP2RAGE sequence for brain imaging at 7T.Methods: Five clusters were identified in a cohort of 39 volunteers. One cluster centered around the average head shape and position, whereas four others were located toward the extremes of the population distribution. Additionally, the one‐size‐fits‐all solution was considered, using a standard universal pulse (UP) approach. Head shapes were characterized using lateral head breadth (HB), anterior–posterior head length (HL), and Y‐shift metrics. For each group, a 5kT‐points universal inversion pulse was computed and evaluated on four new test anatomies. A Python pipeline was integrated into the image reconstruction routine, using localizer scans to classify head shapes and positions. The pipeline selected one of five precomputed population‐specific pulses or defaulted to the generic UP without extending scan time.Results: The pipeline accurately classified head shapes and selected suitable pulses, enhancing the contrast of MP2RAGE images. Population‐specific pulses helped mitigate some of the performance loss associated with using a one‐size‐fits‐all UP, bringing performance closer to that of fully tailored solutions. This approach was particularly beneficial for individuals with smaller head sizes. However, the performance was worse in larger, more challenging head shapes.Conclusion: The novel head clustering and pulse selection pipeline facilitates the implementation of population‐specific pulses in clinical practice by allowing pulse selection tailored to each head shape and position without increasing scan time.
- 4 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1878-1888
Open AccessIn vivo evaluation of population‐specific inversion pulses in parallel transmission
Purpose: The aim of the study was to conduct in vivo evaluation of population‐specific pulses in the context of the MP2RAGE sequence for brain imaging at 7T.Methods: Five clusters were identified in a cohort of 39 volunteers. One cluster centered around the average head shape and position, whereas four others were located toward the extremes of the population distribution. Additionally, the one‐size‐fits‐all solution was considered, using a standard universal pulse (UP) approach. Head shapes were characterized using lateral head breadth (HB), anterior–posterior head length (HL), and Y‐shift metrics. For each group, a 5kT‐points universal inversion pulse was computed and evaluated on four new test anatomies. A Python pipeline was integrated into the image reconstruction routine, using localizer scans to classify head shapes and positions. The pipeline selected one of five precomputed population‐specific pulses or defaulted to the generic UP without extending scan time.Results: The pipeline accurately classified head shapes and selected suitable pulses, enhancing the contrast of MP2RAGE images. Population‐specific pulses helped mitigate some of the performance loss associated with using a one‐size‐fits‐all UP, bringing performance closer to that of fully tailored solutions. This approach was particularly beneficial for individuals with smaller head sizes. However, the performance was worse in larger, more challenging head shapes.Conclusion: The novel head clustering and pulse selection pipeline facilitates the implementation of population‐specific pulses in clinical practice by allowing pulse selection tailored to each head shape and position without increasing scan time.
- Open Access
- 17 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (2) , 570-582
What can we gain from subpopulation universal pulses? A simulation‐based study
Purpose: The aim of the study was to explore a novel methodology for designing universal pulses (UPs) that balances the benefits of a calibration‐free approach with subject‐specific online pulse design.Methods: The proposed method involves segmenting the population into subpopulations with variability in anatomical shapes and positions reduced to 75%, 50%, and 25% of their original values while keeping the mean values unchanged. An additional 25% extreme case with a large volume of interest and shifted position was included. For each group, a 5kT‐points universal inversion pulse was designed and assessed by the normalized root mean square error (NRMSE) on the target longitudinal magnetization profile. The performance was compared to the conventional one‐size‐fits‐all approach. A total of 132 electromagnetic simulations were executed to generate representative anatomies and specific absorption rate (SAR) distributions in a three‐dimensional parameter space comprised of head breadth, head length, and Y‐shift. The 99.9th percentile on the peak local SAR distribution was utilized to establish an intersubject variability safety margin.Results: UPs designed for subpopulations with decreased head shape and position variability reduced the anatomical safety margin by up to 20%. Furthermore, when a head was significantly different to the average case, the proposed approach improved the inversion homogeneity by up to 24%, compared to the conventional one‐size‐fits‐all approach.Conclusion: Subpopulation UPs present an opportunity to improve the homogeneity and reduce anatomical SAR safety margins at 7T without additional acquisition time for calibration.
- 17 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (2) , 570-582
Open AccessWhat can we gain from subpopulation universal pulses? A simulation‐based study
Purpose: The aim of the study was to explore a novel methodology for designing universal pulses (UPs) that balances the benefits of a calibration‐free approach with subject‐specific online pulse design.Methods: The proposed method involves segmenting the population into subpopulations with variability in anatomical shapes and positions reduced to 75%, 50%, and 25% of their original values while keeping the mean values unchanged. An additional 25% extreme case with a large volume of interest and shifted position was included. For each group, a 5kT‐points universal inversion pulse was designed and assessed by the normalized root mean square error (NRMSE) on the target longitudinal magnetization profile. The performance was compared to the conventional one‐size‐fits‐all approach. A total of 132 electromagnetic simulations were executed to generate representative anatomies and specific absorption rate (SAR) distributions in a three‐dimensional parameter space comprised of head breadth, head length, and Y‐shift. The 99.9th percentile on the peak local SAR distribution was utilized to establish an intersubject variability safety margin.Results: UPs designed for subpopulations with decreased head shape and position variability reduced the anatomical safety margin by up to 20%. Furthermore, when a head was significantly different to the average case, the proposed approach improved the inversion homogeneity by up to 24%, compared to the conventional one‐size‐fits‐all approach.Conclusion: Subpopulation UPs present an opportunity to improve the homogeneity and reduce anatomical SAR safety margins at 7T without additional acquisition time for calibration.
- Open Access
- 24 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 177-193
Hybrid adiabatic pulse with asymmetry (HAPY): An asymmetric adiabatic pulse with an application in pulsed arterial spin labeling at 7T
PurposeA new class of asymmetric adiabatic radiofrequency (RF) pulses, Hybrid Adiabatic Pulse with asYmmetry (HAPY), is designed to be used as the labeling pulse for Pulsed Arterial Spin labeling (PASL) at 7T to reduce overall specific absorption rate (SAR) while maintaining high labeling efficiency with B0$$ {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ inhomogeneities. MethodsRealistic Delta B0$$ \Delta {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ distributions were extracted from multiple in vivo scans. The proposed class of asymmetric pulses was parameterized and optimized considering these conditions. Simulation and phantoms experiments were performed to compare the optimized pulses with HS-3, GOIA, and trFOCI pulses. In vivo experiments were conducted to demonstrate the application of HAPY in PICORE PASL at 7T, compared with the GOIA and trFOCI pulses. ResultsHAPYs with different amounts of pulse energy reduction are obtained by the proposed optimization framework. Both simulation and phantom experiments demonstrate that HAPY achieves high labeling efficiency and high selectivity along the critical side despite B0$$ {\mathrm{B}}_0 $$ off-resonance and low B1+$$ {\mathrm{B}}_1<^>{+} $$ amplitude. In vivo experiments reveal that HAPY is able to generate robust perfusion signal with less overall SAR or shorter pulse repetition time, compared to the GOIA and trFOCI pulses. ConclusionThe HAPY class of pulses, obtained via systematic optimization tailored to the application of PASL at 7T, reduces power deposition without affecting labeling efficiency, which provides a prospect of further exploiting the benefits of ultra-high field in ASL.- 24 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 177-193
Open AccessHybrid adiabatic pulse with asymmetry (HAPY): An asymmetric adiabatic pulse with an application in pulsed arterial spin labeling at 7T
PurposeA new class of asymmetric adiabatic radiofrequency (RF) pulses, Hybrid Adiabatic Pulse with asYmmetry (HAPY), is designed to be used as the labeling pulse for Pulsed Arterial Spin labeling (PASL) at 7T to reduce overall specific absorption rate (SAR) while maintaining high labeling efficiency with B0$$ {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ inhomogeneities. MethodsRealistic Delta B0$$ \Delta {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ distributions were extracted from multiple in vivo scans. The proposed class of asymmetric pulses was parameterized and optimized considering these conditions. Simulation and phantoms experiments were performed to compare the optimized pulses with HS-3, GOIA, and trFOCI pulses. In vivo experiments were conducted to demonstrate the application of HAPY in PICORE PASL at 7T, compared with the GOIA and trFOCI pulses. ResultsHAPYs with different amounts of pulse energy reduction are obtained by the proposed optimization framework. Both simulation and phantom experiments demonstrate that HAPY achieves high labeling efficiency and high selectivity along the critical side despite B0$$ {\mathrm{B}}_0 $$ off-resonance and low B1+$$ {\mathrm{B}}_1<^>{+} $$ amplitude. In vivo experiments reveal that HAPY is able to generate robust perfusion signal with less overall SAR or shorter pulse repetition time, compared to the GOIA and trFOCI pulses. ConclusionThe HAPY class of pulses, obtained via systematic optimization tailored to the application of PASL at 7T, reduces power deposition without affecting labeling efficiency, which provides a prospect of further exploiting the benefits of ultra-high field in ASL. - 24 May 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (3) , 1370-1379
The “Spin‐3/2 Bloch Equation”: System matrix formalism of excitation, relaxation, and off‐resonance effects in biological tissue
Purpose:This work proposes "Spin-3/2 Bloch Equation" (SBE), a consolidated formalism for spin-3/2 dynamics in biological environments. The formalism encapsulates excitation, relaxation, and off-resonance with accessible matrix representation for a straightforward implementation with high computational efficiency. Theory: The SBE is derived using spherical tensor operators to encapsulate the spin-3/2 dynamics in biological systems in a single system matrix, a formalism akin to the well-known Bloch Equations (BE). Methods: Using the proposed SBE, simulations of three classical Na-23 pulse sequences were performed to demonstrate the versatility and applicability of the model, returning the evolution of the Na-23 spin system during these experiments: soft rectangular and adiabatic inversion recovery (IR) and triple-quantum filtering. IR simulations were compared with two existing spin-3/2 simulators and the adaptive BE as a first-order approximation. Results: The proposed SBE is straightforward to implement and facilitates accurate and fast simulations of the underlying higher order coherence in sodium experiments of biological tissues. SBE simulations and comparison spin-3/2 simulators outperform the BE simulations as expected, with the SBE offering superior computational efficiency achieved by the single system matrix formalism. Conclusion: The proposed SBE enables comprehensive and accurate simulations for spin-3/2 systems in biological tissue. With a one-line call to an ordinary differential equation solver, it offers a computationally efficient and accessible method for use in Na-23 pulse sequence design.
- 24 May 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (3) , 1370-1379
The “Spin‐3/2 Bloch Equation”: System matrix formalism of excitation, relaxation, and off‐resonance effects in biological tissue
Purpose:This work proposes "Spin-3/2 Bloch Equation" (SBE), a consolidated formalism for spin-3/2 dynamics in biological environments. The formalism encapsulates excitation, relaxation, and off-resonance with accessible matrix representation for a straightforward implementation with high computational efficiency. Theory: The SBE is derived using spherical tensor operators to encapsulate the spin-3/2 dynamics in biological systems in a single system matrix, a formalism akin to the well-known Bloch Equations (BE). Methods: Using the proposed SBE, simulations of three classical Na-23 pulse sequences were performed to demonstrate the versatility and applicability of the model, returning the evolution of the Na-23 spin system during these experiments: soft rectangular and adiabatic inversion recovery (IR) and triple-quantum filtering. IR simulations were compared with two existing spin-3/2 simulators and the adaptive BE as a first-order approximation. Results: The proposed SBE is straightforward to implement and facilitates accurate and fast simulations of the underlying higher order coherence in sodium experiments of biological tissues. SBE simulations and comparison spin-3/2 simulators outperform the BE simulations as expected, with the SBE offering superior computational efficiency achieved by the single system matrix formalism. Conclusion: The proposed SBE enables comprehensive and accurate simulations for spin-3/2 systems in biological tissue. With a one-line call to an ordinary differential equation solver, it offers a computationally efficient and accessible method for use in Na-23 pulse sequence design.
- Open Access
- 1 May 2020
- Published by Elsevier in NeuroImage
- Vol. 211, 116609
Microstructural correlates of 23Na relaxation in human brain at 7 Tesla
- 1 May 2020
- Published by Elsevier in NeuroImage
- Vol. 211, 116609
Open AccessMicrostructural correlates of 23Na relaxation in human brain at 7 Tesla
- 1 November 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 308, 106595
Spin Lock Adiabatic Correction (SLAC) for B1-insensitive pulse design at 7T
- 1 November 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 308, 106595
Spin Lock Adiabatic Correction (SLAC) for B1-insensitive pulse design at 7T
- 10 September 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (3) , 1025-1033
Compressed sensing effects on quantitative analysis of undersampled human brain sodium MRI
Purpose: The clinical application of sodium MRI is hampered due to relatively low image quality and associated long acquisition times. Compressed sensing (CS) aims at a reduction of measurement time, but has been found to encompass quantitative estimation bias when used in low SNR x‐Nuclei imaging. This work analyses CS in quantitative human brain sodium MRI from undersampled acquisitions and provides recommendations for tissue sodium concentration (TSC) estimation.Methods: CS reconstructions from 3D radial acquisitions of 5 healthy volunteers were investigated over varying undersampling factors (USFs) and CS penalty weights on different sparsity domains, Wavelet, Discrete Cosine Transform (DCT), and Identity. Resulting images were compared with highly sampled and undersampled NUFFT‐based images and evaluated for image quality (i.e. structural similarity), image intensity bias, and its effect on TSC estimates in gray and white matter.Results: Wavelet‐based CS reconstructions show highest image quality with stable TSC estimates for most USFs. Up to an USF of 4, images showed good structural detail. DCT and Identity‐based CS enable good image quality, however show a bias in TSC with a reduction in estimates across USFs.Conclusions: The image intensity bias is lowest in Wavelet‐based reconstructions and enables an up to fourfold acquisition speed up while maintaining good structural detail. The associated acquisition time reduction can facilitate a translation of sodium MRI into clinical routine.
- 10 September 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (3) , 1025-1033
Compressed sensing effects on quantitative analysis of undersampled human brain sodium MRI
Purpose: The clinical application of sodium MRI is hampered due to relatively low image quality and associated long acquisition times. Compressed sensing (CS) aims at a reduction of measurement time, but has been found to encompass quantitative estimation bias when used in low SNR x‐Nuclei imaging. This work analyses CS in quantitative human brain sodium MRI from undersampled acquisitions and provides recommendations for tissue sodium concentration (TSC) estimation.Methods: CS reconstructions from 3D radial acquisitions of 5 healthy volunteers were investigated over varying undersampling factors (USFs) and CS penalty weights on different sparsity domains, Wavelet, Discrete Cosine Transform (DCT), and Identity. Resulting images were compared with highly sampled and undersampled NUFFT‐based images and evaluated for image quality (i.e. structural similarity), image intensity bias, and its effect on TSC estimates in gray and white matter.Results: Wavelet‐based CS reconstructions show highest image quality with stable TSC estimates for most USFs. Up to an USF of 4, images showed good structural detail. DCT and Identity‐based CS enable good image quality, however show a bias in TSC with a reduction in estimates across USFs.Conclusions: The image intensity bias is lowest in Wavelet‐based reconstructions and enables an up to fourfold acquisition speed up while maintaining good structural detail. The associated acquisition time reduction can facilitate a translation of sodium MRI into clinical routine.
- 16 January 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (6) , 3854-3864
A continuum of components: Flexible fast fraction mapping in sodium MRI
Purpose: Parameter mapping in sodium MRI data is challenging due to inherently low SNR and spatial resolution, prompting the need to employ robust models and estimation techniques. This work aims to develop a continuum model of sodium ‐decay to overcome the limitations of the commonly employed bi‐exponential models. Estimates of mean ‐decay and fast component fraction in tissue are emergent from the inferred continuum model.Methods: A closed‐form continuum model was derived assuming a gamma distribution of components. Sodium MRI was performed on four healthy human subjects and a phantom consisting of closely packed vials filled with an aqueous solution of varying sodium and agarose concentrations. The continuum model was applied to the phantom and in vivo human multi‐echo 7T data. Parameter maps by voxelwise model‐fitting were obtained.Results: The continuum model demonstrated comparable estimation performance to the bi‐exponential model. The parameter maps provided improved contrast between tissue structures. The fast component fraction, an indicator of the heterogeneity of localised sodium motion regimes in tissue, was zero in CSF and high in WM structures.Conclusions: The continuum distribution model provides high quality, high contrast parameter maps, and informative voxelwise estimates of the relative weighting between fast and slow decay components.
- 16 January 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (6) , 3854-3864
A continuum of components: Flexible fast fraction mapping in sodium MRI
Purpose: Parameter mapping in sodium MRI data is challenging due to inherently low SNR and spatial resolution, prompting the need to employ robust models and estimation techniques. This work aims to develop a continuum model of sodium ‐decay to overcome the limitations of the commonly employed bi‐exponential models. Estimates of mean ‐decay and fast component fraction in tissue are emergent from the inferred continuum model.Methods: A closed‐form continuum model was derived assuming a gamma distribution of components. Sodium MRI was performed on four healthy human subjects and a phantom consisting of closely packed vials filled with an aqueous solution of varying sodium and agarose concentrations. The continuum model was applied to the phantom and in vivo human multi‐echo 7T data. Parameter maps by voxelwise model‐fitting were obtained.Results: The continuum model demonstrated comparable estimation performance to the bi‐exponential model. The parameter maps provided improved contrast between tissue structures. The fast component fraction, an indicator of the heterogeneity of localised sodium motion regimes in tissue, was zero in CSF and high in WM structures.Conclusions: The continuum distribution model provides high quality, high contrast parameter maps, and informative voxelwise estimates of the relative weighting between fast and slow decay components.