Hybrid adiabatic pulse with asymmetry (HAPY): An asymmetric adiabatic pulse with an application in pulsed arterial spin labeling at 7T
Open Access
- 24 March 2023
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 177-193
Abstract
PurposeA new class of asymmetric adiabatic radiofrequency (RF) pulses, Hybrid Adiabatic Pulse with asYmmetry (HAPY), is designed to be used as the labeling pulse for Pulsed Arterial Spin labeling (PASL) at 7T to reduce overall specific absorption rate (SAR) while maintaining high labeling efficiency with B0$$ {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ inhomogeneities. MethodsRealistic Delta B0$$ \Delta {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ distributions were extracted from multiple in vivo scans. The proposed class of asymmetric pulses was parameterized and optimized considering these conditions. Simulation and phantoms experiments were performed to compare the optimized pulses with HS-3, GOIA, and trFOCI pulses. In vivo experiments were conducted to demonstrate the application of HAPY in PICORE PASL at 7T, compared with the GOIA and trFOCI pulses. ResultsHAPYs with different amounts of pulse energy reduction are obtained by the proposed optimization framework. Both simulation and phantom experiments demonstrate that HAPY achieves high labeling efficiency and high selectivity along the critical side despite B0$$ {\mathrm{B}}_0 $$ off-resonance and low B1+$$ {\mathrm{B}}_1<^>{+} $$ amplitude. In vivo experiments reveal that HAPY is able to generate robust perfusion signal with less overall SAR or shorter pulse repetition time, compared to the GOIA and trFOCI pulses. ConclusionThe HAPY class of pulses, obtained via systematic optimization tailored to the application of PASL at 7T, reduces power deposition without affecting labeling efficiency, which provides a prospect of further exploiting the benefits of ultra-high field in ASL.
Keywords
This publication has 43 references indexed in Scilit:
- Turbo-FLASH Based Arterial Spin Labeled Perfusion MRI at 7 TPLOS ONE, 2013
- A robust methodology for in vivo T1 mappingMagnetic Resonance in Medicine, 2010
- Spectroscopic imaging with improved gradient modulated constant adiabaticity pulses on high-field clinical scannersJournal of Magnetic Resonance, 2010
- Arterial spin labeling at ultra‐high field: All that glitters is not goldInternational Journal of Imaging Systems and Technology, 2010
- Tailored RF pulse for magnetization inversion at ultrahigh fieldMagnetic Resonance in Medicine, 2009
- Implementation of quantitative perfusion imaging using pulsed arterial spin labeling at ultra‐high fieldMagnetic Resonance in Medicine, 2009
- Reducing contamination while closing the gap: BASSI RF pulses in PASLMagnetic Resonance in Medicine, 2006
- Bandwidth‐modulated adiabatic RF pulses for uniform selective saturation and inversionMagnetic Resonance in Medicine, 2004
- New FOCI pulses with reduced radiofrequency power requirementsJournal of Magnetic Resonance Imaging, 2004
- Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithmIEEE Transactions on Medical Imaging, 2001