Nil Franch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Nil Franch has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Angel Dieguez
Department of Electronics and Biomedical Engineering, Universitat de Barcelona, 08028 Barcelona, Spain
10 shared publications - Joan Canals
Department of Electronic and Biomedical Engineering, Universitat de Barcelona, Marti i Franqués 1, 08028 Barcelona, Spain
8 shared publications - Anna Vila
Department of Electronic and Biomedical Engineering, Universitat de Barcelona, Marti i Franqués 1, 08028 Barcelona, Spain
7 shared publications - Oscar Alonso
Department of Electronics and Biomedical Engineering, Universitat de Barcelona, 08028 Barcelona, Spain
6 shared publications - Andreas Waag
Institute of Semiconductor Technology, Technische Universität Braunschweig 1 , Hans-Sommer-Str. 66, 38106 Braunschweig
3 shared publications - Joan Daniel Prades
Institute of Semiconductor Technology (IHT), Technische Universität Braunschweig, D-38106 Braunschweig, Germany
3 shared publications
Latest Publications
- 16 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-06
High-Speed 512x512 18 μm-Pitch Array CMOS Backplane for GaN-based Microdisplay
GaN-on-Si based hybrid microdisplays have been the revolution as point-like light sources for scientific, communications, and imaging applications because of their high-resolution, high-brightness, and high-speed capabilities. Nevertheless, the microdisplay driving circuits usually focus only on two of these characteristics. In this work, we present a CMOS backplane that aims to exploit the capabilities of the GaN-based micro-arrays. The back panel can drive an array of GaN LED pixels of up to 512x512 of 1411 PPI (pixel per inch) with an in-pixel driver that offers a bias current up to 120 μA. The smart pixel control circuit has a 4-bit grayscale resolution. Frames can be updated at up to 10 kfps. Finally, the backplane can be operated in pulsed mode, toggling the entire array between the stored frame and off state at 1 MHz. The backplane design in 180 nm CMOS process and the in-pixel driver simulations results are presented.
- 16 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-06
High-Speed 512x512 18 μm-Pitch Array CMOS Backplane for GaN-based Microdisplay
GaN-on-Si based hybrid microdisplays have been the revolution as point-like light sources for scientific, communications, and imaging applications because of their high-resolution, high-brightness, and high-speed capabilities. Nevertheless, the microdisplay driving circuits usually focus only on two of these characteristics. In this work, we present a CMOS backplane that aims to exploit the capabilities of the GaN-based micro-arrays. The back panel can drive an array of GaN LED pixels of up to 512x512 of 1411 PPI (pixel per inch) with an in-pixel driver that offers a bias current up to 120 μA. The smart pixel control circuit has a 4-bit grayscale resolution. Frames can be updated at up to 10 kfps. Finally, the backplane can be operated in pulsed mode, toggling the entire array between the stored frame and off state at 1 MHz. The backplane design in 180 nm CMOS process and the in-pixel driver simulations results are presented.
- Open Access
Pursuing the Diffraction Limit with Nano-LED Scanning Transmission Optical Microscopy
Recent research into miniaturized illumination sources has prompted the development of alternative microscopy techniques. Although they are still being explored, emerging nano-light-emitting-diode (nano-LED) technologies show promise in approaching the optical resolution limit in a more feasible manner. This work presents the exploration of their capabilities with two different prototypes. In the first version, a resolution of less than 1 µm was shown thanks to a prototype based on an optically downscaled LED using an LED scanning transmission optical microscopy (STOM) technique. This research demonstrates how this technique can be used to improve STOM images by oversampling the acquisition. The second STOM-based microscope was fabricated with a 200 nm GaN LED. This demonstrates the possibilities for the miniaturization of on-chip-based microscopes.
Open AccessPursuing the Diffraction Limit with Nano-LED Scanning Transmission Optical Microscopy
Recent research into miniaturized illumination sources has prompted the development of alternative microscopy techniques. Although they are still being explored, emerging nano-light-emitting-diode (nano-LED) technologies show promise in approaching the optical resolution limit in a more feasible manner. This work presents the exploration of their capabilities with two different prototypes. In the first version, a resolution of less than 1 µm was shown thanks to a prototype based on an optically downscaled LED using an LED scanning transmission optical microscopy (STOM) technique. This research demonstrates how this technique can be used to improve STOM images by oversampling the acquisition. The second STOM-based microscope was fabricated with a 200 nm GaN LED. This demonstrates the possibilities for the miniaturization of on-chip-based microscopes.
- Open Access
- 6 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (5) , 527
A Novel Approach for a Chip-Sized Scanning Optical Microscope
The recent advances in chip-size microscopy based on optical scanning with spatially resolved nano-illumination light sources are presented. This new straightforward technique takes advantage of the currently achieved miniaturization of LEDs in fully addressable arrays. These nano-LEDs are used to scan the sample with a resolution comparable to the LED sizes, giving rise to chip-sized scanning optical microscopes without mechanical parts or optical accessories. The operation principle and the potential of this new kind of microscope are analyzed through three different implementations of decreasing LED dimensions from 20 µm down to 200 nm.
- 6 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (5) , 527
Open AccessA Novel Approach for a Chip-Sized Scanning Optical Microscope
The recent advances in chip-size microscopy based on optical scanning with spatially resolved nano-illumination light sources are presented. This new straightforward technique takes advantage of the currently achieved miniaturization of LEDs in fully addressable arrays. These nano-LEDs are used to scan the sample with a resolution comparable to the LED sizes, giving rise to chip-sized scanning optical microscopes without mechanical parts or optical accessories. The operation principle and the potential of this new kind of microscope are analyzed through three different implementations of decreasing LED dimensions from 20 µm down to 200 nm.
- 12 June 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (13) , 19044-19057
Nano illumination microscopy: a technique based on scanning with an array of individually addressable nanoLEDs
In lensless microscopy, spatial resolution is usually provided by the pixel density of current digital cameras, which are reaching a hard-to-surpass pixel size / resolution limit over 1 µm. As an alternative, the dependence of the resolving power can be moved from the detector to the light sources, offering a new kind of lensless microscopy setups. The use of continuously scaled-down Light-Emitting Diode (LED) arrays to scan the sample allows resolutions on order of the LED size, giving rise to compact and low-cost microscopes without mechanical scanners or optical accessories. In this paper, we present the operation principle of this new approach to lensless microscopy, with simulations that demonstrate the possibility to use it for super-resolution, as well as a first prototype. This proof-of-concept setup integrates an 8 × 8 array of LEDs, each 5 × 5 μm2 pixel size and 10 μm pitch, and an optical detector. We characterize the system using Electron-Beam Lithography (EBL) pattern. Our prototype validates the imaging principle and opens the way to improve resolution by further miniaturizing the light sources.
- 12 June 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (13) , 19044-19057
Nano illumination microscopy: a technique based on scanning with an array of individually addressable nanoLEDs
In lensless microscopy, spatial resolution is usually provided by the pixel density of current digital cameras, which are reaching a hard-to-surpass pixel size / resolution limit over 1 µm. As an alternative, the dependence of the resolving power can be moved from the detector to the light sources, offering a new kind of lensless microscopy setups. The use of continuously scaled-down Light-Emitting Diode (LED) arrays to scan the sample allows resolutions on order of the LED size, giving rise to compact and low-cost microscopes without mechanical scanners or optical accessories. In this paper, we present the operation principle of this new approach to lensless microscopy, with simulations that demonstrate the possibility to use it for super-resolution, as well as a first prototype. This proof-of-concept setup integrates an 8 × 8 array of LEDs, each 5 × 5 μm2 pixel size and 10 μm pitch, and an optical detector. We characterize the system using Electron-Beam Lithography (EBL) pattern. Our prototype validates the imaging principle and opens the way to improve resolution by further miniaturizing the light sources.
- Open Access
A Point-of-Care Device for Molecular Diagnosis Based on CMOS SPAD Detectors with Integrated Microfluidics
We describe the integration of techniques and technologies to develop a Point-of-Care for molecular diagnosis PoC-MD, based on a fluorescence lifetime measurement. Our PoC-MD is a low-cost, simple, fast, and easy-to-use general-purpose platform, aimed at carrying out fast diagnostics test through label detection of a variety of biomarkers. It is based on a 1-D array of 10 ultra-sensitive Single-Photon Avalanche Diode (SPAD) detectors made in a 0.18 μm High-Voltage Complementary Metal Oxide Semiconductor (HV-CMOS) technology. A custom microfluidic polydimethylsiloxane cartridge to insert the sample is straightforwardly positioned on top of the SPAD array without any alignment procedure with the SPAD array. Moreover, the proximity between the sample and the gate-operated SPAD sensor makes unnecessary any lens or optical filters to detect the fluorescence for long lifetime fluorescent dyes, such as quantum dots. Additionally, the use of a low-cost laser diode as pulsed excitation source and a Field-Programmable Gate Array (FPGA) to implement the control and processing electronics, makes the device flexible and easy to adapt to the target label molecule by only changing the laser diode. Using this device, reliable and sensitive real-time proof-of-concept fluorescence lifetime measurement of quantum dot QdotTM 605 streptavidin conjugate is demonstrated.
Open AccessA Point-of-Care Device for Molecular Diagnosis Based on CMOS SPAD Detectors with Integrated Microfluidics
We describe the integration of techniques and technologies to develop a Point-of-Care for molecular diagnosis PoC-MD, based on a fluorescence lifetime measurement. Our PoC-MD is a low-cost, simple, fast, and easy-to-use general-purpose platform, aimed at carrying out fast diagnostics test through label detection of a variety of biomarkers. It is based on a 1-D array of 10 ultra-sensitive Single-Photon Avalanche Diode (SPAD) detectors made in a 0.18 μm High-Voltage Complementary Metal Oxide Semiconductor (HV-CMOS) technology. A custom microfluidic polydimethylsiloxane cartridge to insert the sample is straightforwardly positioned on top of the SPAD array without any alignment procedure with the SPAD array. Moreover, the proximity between the sample and the gate-operated SPAD sensor makes unnecessary any lens or optical filters to detect the fluorescence for long lifetime fluorescent dyes, such as quantum dots. Additionally, the use of a low-cost laser diode as pulsed excitation source and a Field-Programmable Gate Array (FPGA) to implement the control and processing electronics, makes the device flexible and easy to adapt to the target label molecule by only changing the laser diode. Using this device, reliable and sensitive real-time proof-of-concept fluorescence lifetime measurement of quantum dot QdotTM 605 streptavidin conjugate is demonstrated.
- Open Access
- 29 November 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (8) , 758
A Portable Fluorescence Lifetime Spectroscopy Detector for Molecular Diagnosis
Fluorescence-based techniques are amongst the most widely used methods in molecular
- 29 November 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (8) , 758
Open AccessA Portable Fluorescence Lifetime Spectroscopy Detector for Molecular Diagnosis
Fluorescence-based techniques are amongst the most widely used methods in molecular
- Open Access
- 13 July 2017
- Published by Universitat Politecnica de Valencia
Mejora de la implicación del alumnado en “Diseño y síntesis de sistemas digitales” usando e-learning colaborativo, gamificación y aprendizaje basado en problemas
Mejora de la implicación del alumnado en “Diseño y síntesis de sistemas digitales” usando e-learning colaborativo, gamificación y aprendizaje basado en problemas
- 13 July 2017
- Published by Universitat Politecnica de Valencia
Open AccessMejora de la implicación del alumnado en “Diseño y síntesis de sistemas digitales” usando e-learning colaborativo, gamificación y aprendizaje basado en problemas
Mejora de la implicación del alumnado en “Diseño y síntesis de sistemas digitales” usando e-learning colaborativo, gamificación y aprendizaje basado en problemas
- 1 February 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (2) , C02069
Readout electronics for LGAD sensors
In this paper, an ASIC fabricated in 180 nm CMOS technology from AMS with the very front-end electronics used to readout LGAD sensors is presented as well as its experimental results. The front-end has the typical architecture for Si-strip readout, i.e., preamplification stage with a Charge Sensitive Amplifier (CSA) followed by a CR-RC shaper. Both amplifiers are based on a folded cascode structure with a PMOS input transistor and the shaper only uses passive elements for the feedback stage. The CSA has programmable gain and a configurable input stage in order to adapt to the different input capacitance of the LGAD sensors (pixelated, short and long strips) and to the different input signal (depending on the gain of the LGAD). The fabricated prototype has an area of 0.865 mm × 0.965 mm and includes the biasing circuit for the CSA and the shaper, 4 analog channels (CSA+shaper) and programmable charge injection circuits included for testing purposes. Noise and power analysis performed during simulation fixed the size of the input transistor to W/L = 860 μm/0.2 μm. The shaping time is fixed by design at 1 us and, in this ASIC version, the feedback elements of the shaper are passive, which means that the area of the shaper can be reduced using active elements in future versions. Finally, the different gains of the CSA have been selected to maintain an ENC below 400 electrons for a detector capacitor of 20 pF, with a power consumption of 150 μ W per channel.
- 1 February 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (2) , C02069
Readout electronics for LGAD sensors
In this paper, an ASIC fabricated in 180 nm CMOS technology from AMS with the very front-end electronics used to readout LGAD sensors is presented as well as its experimental results. The front-end has the typical architecture for Si-strip readout, i.e., preamplification stage with a Charge Sensitive Amplifier (CSA) followed by a CR-RC shaper. Both amplifiers are based on a folded cascode structure with a PMOS input transistor and the shaper only uses passive elements for the feedback stage. The CSA has programmable gain and a configurable input stage in order to adapt to the different input capacitance of the LGAD sensors (pixelated, short and long strips) and to the different input signal (depending on the gain of the LGAD). The fabricated prototype has an area of 0.865 mm × 0.965 mm and includes the biasing circuit for the CSA and the shaper, 4 analog channels (CSA+shaper) and programmable charge injection circuits included for testing purposes. Noise and power analysis performed during simulation fixed the size of the input transistor to W/L = 860 μm/0.2 μm. The shaping time is fixed by design at 1 us and, in this ASIC version, the feedback elements of the shaper are passive, which means that the area of the shaper can be reduced using active elements in future versions. Finally, the different gains of the CSA have been selected to maintain an ENC below 400 electrons for a detector capacitor of 20 pF, with a power consumption of 150 μ W per channel.
- 1 February 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (02) , C02070
A low cost fluorescence lifetime measurement system based on SPAD detectors and FPGA processing
This work presents a low cost fluorescence life time measurement system, aimed at carrying out fast diagnostic tests through label detection in a portable system so it can be used in a medical consultation, within a short time span. The system uses Time Correlated Single Photon Counting (TCSPC), measuring the arrival time of individual photons and building a histogram of those times, showing the fluorescence decay of the label which is characteristic of each fluorescent substance. The system is implemented using a Xilinx FPGA which controls the experiment and includes a Time to Digital Converter (TDC) to perform measurements with a resolution in the order of tenths of picoseconds. Also included are a laser diode and the driving electronics to generate short pulses as well as a HV-CMOS implemented Single Photon Avalanche Diode (SPAD) as a high gain sensor. The system is entirely configurable so it can easily be adapted to the target label molecule and measurement needs. The histogram is constructed within the FPGA and can then be read as convenient. Various performance parameters are also shown, as well as experimental measurements of a quantum dot fluorescence decay as a proof of concept.
- 1 February 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (02) , C02070
A low cost fluorescence lifetime measurement system based on SPAD detectors and FPGA processing
This work presents a low cost fluorescence life time measurement system, aimed at carrying out fast diagnostic tests through label detection in a portable system so it can be used in a medical consultation, within a short time span. The system uses Time Correlated Single Photon Counting (TCSPC), measuring the arrival time of individual photons and building a histogram of those times, showing the fluorescence decay of the label which is characteristic of each fluorescent substance. The system is implemented using a Xilinx FPGA which controls the experiment and includes a Time to Digital Converter (TDC) to perform measurements with a resolution in the order of tenths of picoseconds. Also included are a laser diode and the driving electronics to generate short pulses as well as a HV-CMOS implemented Single Photon Avalanche Diode (SPAD) as a high gain sensor. The system is entirely configurable so it can easily be adapted to the target label molecule and measurement needs. The histogram is constructed within the FPGA and can then be read as convenient. Various performance parameters are also shown, as well as experimental measurements of a quantum dot fluorescence decay as a proof of concept.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A low cost fluorescence lifetime measurement system based on SPAD detectors and FPGA processing
This work presents a low cost fluorescence life time measurement system, aimed at carrying out fast diagnostic tests through label detection in a portable system so it can be used in a medical consultation, within a short time span. The system uses Time Correlated Single Photon Counting (TCSPC), measuring the arrival time of individual photons and building a histogram of those times, showing the fluorescence decay of the label which is characteristic of each fluorescent substance. The system is implemented using a Xilinx FPGA which controls the experiment and includes a Time to Digital Converter (TDC) to perform measurements with a resolution in the order of tenths of picoseconds. Also included are a laser diode and the driving electronics to generate short pulses as well as a HV-CMOS implemented Single Photon Avalanche Diode (SPAD) as a high gain sensor. The system is entirely configurable so it can easily be adapted to the target label molecule and measurement needs. The histogram is constructed within the FPGA and can then be read as convenient. Various performance parameters are also shown, as well as experimental measurements of a quantum dot fluorescence decay as a proof of concept.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A low cost fluorescence lifetime measurement system based on SPAD detectors and FPGA processing
This work presents a low cost fluorescence life time measurement system, aimed at carrying out fast diagnostic tests through label detection in a portable system so it can be used in a medical consultation, within a short time span. The system uses Time Correlated Single Photon Counting (TCSPC), measuring the arrival time of individual photons and building a histogram of those times, showing the fluorescence decay of the label which is characteristic of each fluorescent substance. The system is implemented using a Xilinx FPGA which controls the experiment and includes a Time to Digital Converter (TDC) to perform measurements with a resolution in the order of tenths of picoseconds. Also included are a laser diode and the driving electronics to generate short pulses as well as a HV-CMOS implemented Single Photon Avalanche Diode (SPAD) as a high gain sensor. The system is entirely configurable so it can easily be adapted to the target label molecule and measurement needs. The histogram is constructed within the FPGA and can then be read as convenient. Various performance parameters are also shown, as well as experimental measurements of a quantum dot fluorescence decay as a proof of concept.