Latest Publications

  • Advanced Insulation Design for HTS Coils Under High-Vacuum Conditions

    by Minkyung Jeong, Bonhyuk Ku, Yechan Kim, Jaesang Kim, Hyoungku Kang

    High-temperature superconducting (HTS) coils operating in cryogenic vacuum or cryostat environments must withstand both high electrical stresses and mechanical instabilities that can degrade insulation. This paper investigates the electromechanical coupling between structural defects and dielectric breakdown in fast-ramping HTS magnet coils. Although vacuum can provide excellent insulation, localized voids and partial-vacuum pockets formed by winding delamination or buckling can significantly reduce the withstand voltage through strong local electric-field enhancement. Dielectric breakdown experiments were performed on epoxy resin samples with various thicknesses in liquid nitrogen (LN₂) and in low-pressure vacuum, and finite element method (FEM) simulations of REBCO single-pancake coil were conducted to evaluate how internal voids and local buckling influence the electric-field distribution. The breakdown voltage increases with insulation thickness in both LN₂ and vacuum, whereas the effective breakdown field (kV/mm) decreases with thickness. FEM results show that mechanical defects, such as gaps or loose turns, concentrate the electric field at conductor–insulator–void triple-junction interfaces, leading to insulation failure at significantly lower voltages. An improved insulation design using epoxy impregnation at the top and bottom of the coil is proposed to fill voids and reinforce the winding structure. The simulations indicate that a 0.5 mm epoxy layer substantially reduces the peak electric field in defect regions, consistent with experimental observations. The resulting thickness-dependent breakdown characteristics provide practical design curves for insulation design. Overall, the results demonstrate that mitigating mechanical weaknesses and suppressing localized partial-vacuum pockets are essential for improving the dielectric stability of REBCO coils in vacuum-related environments.

  • Core Technologies in HTS Coils for Particle-Therapy Accelerators: PRPD-Based Defect Diagnostics and Fast-Ramping Field Response

    by Jaesang Kim, Minkyung Jeong, Yechan Kim, Bonhyuk Ku, Junyol Sohn, Seungcheol Lee, Garam Hahn, Seyong Choi, Seungyong Hahn, Hyoungku Kang

    This paper proposes a non-destructive quality control method for High-Temperature Superconducting (HTS) coils based on Phase-Resolved Partial Discharge (PRPD) analysis. To ensure the safety of expensive REBCO tapes during high-voltage testing, stainless-steel (SS304) tapes with identical geometric dimensions ($0.32\rm{ mm}$ thickness, $4\rm{ mm}$ width) were utilized as electromagnetic surrogates. We investigated the PRPD signatures of various winding defects, such as protrusions and layer shifts, in pancake coil configurations. The results demonstrate that each defect type produces distinct “Phase-locked clusters,” providing a reliable diagnostic fingerprint for early-stage failure detection. Furthermore, this study evaluates the insulation performance of polytetrafluoroethylene (PTFE) spray coating as a method for achieving tailored insulation levels. Experimental results, including charging delay and field decay analysis, confirm that PTFE-coated coils exhibit dielectric stability comparable to conventional Kapton-insulated coils while offering superior flexibility in controlling the insulation grade. Given that medical particle accelerators operate under high-speed ramping ($L di/dt$), the localized field enhancement identified by PRPD serves as a critical early warning system to prevent quenches caused by mechanical stress or transient voltages. This study establishes a baseline for extending PRPD-based diagnostics to complex 3D HTS magnet systems, ensuring initial quality and long-term operational reliability.

  • Condition Assessment of an Aged 25.8kV GIS: Evaluating the Potential for Life Extension

    by Uhyeon Jo, Ragil Handito, Yechan Kim, Bonhyuk Ku, Minkyung Jeong, Jinwoo Jeong, Chanyoung Lee, Hyoungku Kang

  • Statistical Lifetime of Gas-Insulated Switchgear in Tropical Climate: A Case Study of PT PLN in Indonesia

    by Ragil Handito, Uhyeon Jo, Bonhyuk Ku, Yechan Kim, Minkyung Jeong, Rofiul Huda, Eko Prasetyo, Hyoungku Kang


  • Lifespan Evaluation of GIS Under Tropical Climate Conditions: An Environmental Impact Analysis

    by Minkyung Jeong, Yechan Kim, Bonhyuk Ku, Jaesang Kim, Herviana, Hyoungku Kang

    This study investigates the effect of tropical climates on the durability and efficiency of GIS (Gas-Insulated Switchgear) in Indonesia, characterized by high humidity, temperature fluctuations, and heavy rainfall. By analyzing operational and failure data of local GIS units and comparing them with CIGRE Technical Brochure benchmarks, this study highlights how environmental conditions accelerate GIS degradation in tropical climates. The research extends beyond lifespan statistics to explore how specific tropical conditions-such as corrosion, insulation damage, and condensation-affect GIS failure modes. The study identifies environmental factors and their degradation mechanisms, suggesting targeted maintenance strategies to mitigate the effects of tropical climates on GIS. The findings offer practical guidelines for utilities in similar environments, emphasizing climate-adapted maintenance to enhance the longevity and reliability of power infrastructure. This evaluation provides valuable insights into electrical engineering, highlighting the importance of considering climate in asset management and maintenance for sustainable power infrastructure in weather-sensitive regions.


  • Condition Assessment for Extending the Life of Aged 25.8kV GIS Using Worst Code Approach

    by Yechan Kim, Minkyung Jeong, Bonhyuk Ku, Junyoung Park, Herviana, Hyoungku Kang

    The objective of this study was to establish a foundation for investigating the possibility of extending the lifespan of a 27-year-old 25.8kV GIS (Gas-Insulated Switchgear) that was operated indoors. Recognizing that traditional time-based replacement strategies may not reflect the true condition of such critical infrastructure, our research adopted a detailed examination protocol. In order to guarantee a comprehensive examination of the components and a reflection of the test results, we have departed from the conventional methodology of utilizing weighted sums for the assessment of health. Instead, we have adopted a ‘Worst Code’ approach. This approach focuses on the condition of the most degraded component to provide a more precise evaluation of the GIS's overall health, enhancing the accuracy of maintenance decisions. Our findings suggest that condition-based assessments, through a structured and quantitative evaluation using the ‘Worst Code’ method, could extend the operational lifetime of GIS units, challenging the conventional time-based criteria in South Korea. This methodology offers a strategic, efficient, and cost-effective asset management practice, indicating a shift towards more accurate evaluations based on actual condition rather than fixed time limits, with implications for aging electrical infrastructure maintenance strategies.

  • Condition Assessment for Extending the Life of Aged 7.2kV Switchgear Using Worst Code Approach

    by Bonhyuk Ku, Minkyung Jeong, Yechan Kim, Herviana, Jaesang Kim, Hyoungku Kang

    This study advances the assessment of aged electrical infrastructure to enhance the longevity and reliability of electrical distribution systems. We conducted a detailed condition evaluation of approximately 30-year-old 7.2kV switchgear using the ‘Worst Code’ evaluation method, which focuses on the condition of the most degraded component rather than aggregating scores across components. This approach yields a more accurate reflection of the switchgear's operational condition, avoiding the issues of traditional aggregated assessments that might conceal critical weaknesses. Our findings suggest that, contrary to time-based replacement strategies, targeted reconditioning can significantly extend the operational lifetime of switchgear beyond its expected lifespan. By employing a structured evaluation and the Worst Code method, this research promotes more accurate condition assessments, supporting better-informed decisions on maintenance and life extension of switchgear units. Furthermore, it underscores the value of condition-based assessments and customized reconditioning in improving asset management, thereby enhancing utilization, reducing unnecessary replacements, and optimizing maintenance budgets. This research advocates for the use of advanced condition assessment methods to ensure the sustainable management, maintenance, and life extension of electrical switchgear.


  • Artificial Intelligence-based Recognition and Classification of PRPD Patterns in Power Cable

    by Jaesang Kim, Minkyung Jeong, Hobin Lee, Yechan Kim, Hyoungku Kang

    This paper explores the application of AI (Artificial Intelligence) to improve diagnostic accuracy in identifying and classifying PRPD (Phase-Resolved Partial Discharge) patterns in power cables, which is crucial for the maintenance and reliability of electrical infrastructure. Partial discharges, indicating defects like corona, surface discharges, and voids, pose significant challenges in power cable management. By simulating these discharges and capturing the resulting signals, this study transforms them into PRPD images, creating a comprehensive dataset for AI analysis. The focus of this research is on utilizing advanced machine learning techniques to process and analyze these images to classify the unique visual characteristics associated with each defect type. A notable achievement of this research is the development and training of a robust AI model that achieved an accuracy rate exceeding 93.8%, demonstrating the potential of AI to revolutionize power cable diagnostics. This approach offers a new path for predictive maintenance, allowing power utilities to prevent potential failures and enhance operational efficiency. Our methodology involves an in-depth analysis of PRPD images using CNN (Convolutional Neural Network) to extract and learn feature representations specific to each type of discharge. The results not only demonstrate the effectiveness of AI in diagnosing electrical equipment but also pave the way for future innovations in the field, potentially setting new industry standards for maintenance strategies and reliability assessments.


  • Electrical Breakdown Characteristics in High-Vacuum Conditions for the Design of Superconducting Coils

    by Junyoung Park, Woocheol Shin, Minkyung Jeong, Bonhyuk Ku, Hobin Lee, Jeonghwan Park, Garam Hahn, Seyong Choi, Seungyong Hahn, Hyoungku Kang

    In recent years, the utilization of high-temperature superconductors (HTS) in medical devices, such as magnetic resonance imaging (MRI) and particle accelerators for cancer treatment, has seen significant growth. This study focuses on the electrical insulation design of fast-ramping HTS saddle magnets, pivotal in reducing the volume and consequent operational costs of particle accelerators. Generally, these HTS magnets are operated under high-vacuum conditions to deter external heat intrusion and optimize thermal efficiency. However, their intricate geometries can inadvertently result in areas of localized vacuum degradation, undermining their electrical insulation capabilities, especially in environments with pressures less than 0.001 Pa. Further, this research delves into the influence of vacuum degree and insulator surface roughness on the electrical breakdown properties. The focus is primarily on the distinctions between sparkover and flashover. Due to their fast-ramping nature, HTS magnets undergo substantial current changes in short durations, leading to the induction of potentially dangerous voltages that might trigger electrical breakdown at sensitive junctures. In light of these challenges, we embarked on a series of experiments to understand electrical breakdown phenomena under diverse vacuum scenarios. These experiments, supplemented with finite element method (FEM) analysis, paved the way for the derivation of empirical formula. These formulas intend to guide the design of HTS magnets, ensuring their electrical insulation remains robust across a range of vacuum conditions.