Liang-Jiu Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Liang-Jiu Jia has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Hanbin Ge
Department of Civil Engineering Meijo University Nagoya Japan
13 shared publications Ping Xiang
9 shared publicationsHanbin Ge
Meijo University
8 shared publications- Ping Xiang
Tongji University
6 shared publications - Gregory Anthony MacRae
Department of Civil and Natural Resources Engineering University of Canterbury Christchurch New Zealand
5 shared publications Hitoshi Kuwamura
5 shared publications
Latest Publications
- 19 November 2026
- Published by Elsevier in Engineering Structures
- Vol. 372
Acceleration mitigation for seismic resilient all-glass structure through base-isolation: Full-scale shaking table test
- 19 November 2026
- Published by Elsevier in Engineering Structures
- Vol. 372
Acceleration mitigation for seismic resilient all-glass structure through base-isolation: Full-scale shaking table test
- 3 August 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (14) , 3732-3752
Full‐Scale Shaking‐Table Evaluation of a Controlled Multiple‐Rocking‐Column System for Low‐Damage Seismic Performance
The growing demand for rapid post‐earthquake functional recovery and minimal structural damage has promoted the development of low‐damage seismic design strategies. Controlled rocking systems have emerged as an effective seismic structural solution for enhancing seismic resilience. To provide experimental evidence for the development of resilient steel structures, this study presents a full‐scale Controlled Multiple‐Rocking‐Column System (CMRCS) developed as part of the RObust BUilding SysTem (ROBUST) project. The system comprises two exterior controlled multiple‐rocking‐column frames and a central low‐damage secondary frame. The secondary frame carries the gravity loads assigned to Grid 2 and provides supplemental lateral resistance. Low‐damage rocking joints are installed at both ends of the rocking columns at each storey. Under frequently occurring earthquakes (FOEs), the CMRCS is designed to behave similarly to a conventional moment‐resisting steel frame, while the multiple‐rocking mechanism is intended to be activated at higher seismic intensities. Full‐scale shaking‐table tests were conducted on a 3‐storey steel frame specimen subjected to ground motions with peak ground accelerations (PGAs) ranging from 0.055 g to 0.62 g. The test results demonstrated that the structure exhibited satisfactory seismic performance, characterized by negligible residual drifts and no visible damage throughout the test sequence. Moreover, the proposed system also satisfied the immediate occupancy performance objective even under very rare earthquake‐level excitation (PGA of 0.62 g), thereby confirming the effectiveness, robustness and seismic resilience of the proposed system.
- 3 August 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (14) , 3732-3752
Full‐Scale Shaking‐Table Evaluation of a Controlled Multiple‐Rocking‐Column System for Low‐Damage Seismic Performance
The growing demand for rapid post‐earthquake functional recovery and minimal structural damage has promoted the development of low‐damage seismic design strategies. Controlled rocking systems have emerged as an effective seismic structural solution for enhancing seismic resilience. To provide experimental evidence for the development of resilient steel structures, this study presents a full‐scale Controlled Multiple‐Rocking‐Column System (CMRCS) developed as part of the RObust BUilding SysTem (ROBUST) project. The system comprises two exterior controlled multiple‐rocking‐column frames and a central low‐damage secondary frame. The secondary frame carries the gravity loads assigned to Grid 2 and provides supplemental lateral resistance. Low‐damage rocking joints are installed at both ends of the rocking columns at each storey. Under frequently occurring earthquakes (FOEs), the CMRCS is designed to behave similarly to a conventional moment‐resisting steel frame, while the multiple‐rocking mechanism is intended to be activated at higher seismic intensities. Full‐scale shaking‐table tests were conducted on a 3‐storey steel frame specimen subjected to ground motions with peak ground accelerations (PGAs) ranging from 0.055 g to 0.62 g. The test results demonstrated that the structure exhibited satisfactory seismic performance, characterized by negligible residual drifts and no visible damage throughout the test sequence. Moreover, the proposed system also satisfied the immediate occupancy performance objective even under very rare earthquake‐level excitation (PGA of 0.62 g), thereby confirming the effectiveness, robustness and seismic resilience of the proposed system.
- 5 July 2026
- Published by Wiley in Earthquake Spectra
- Vol. 42 (3)
Seismic Performance of Multidrum Free‐Rocking Columns With Shear Key
This study experimentally investigates the effects of shear keys on the seismic performance of multidrum free rocking columns (MDFRCs) by means of shaking table tests on two 1:18 specimens, one with and one without shear keys, taking classical stone column as found in the Parthenon as prototype reference. The shaking table test results show that shear keys can significantly reduce interdrum deformation; in the most pronounced case, the interdrum drift ratio at the capital was reduced from approximately 20% to 6%, corresponding to a relative reduction of more than 70%. Corresponding finite element (FE) models were then developed, validated against the experimental results, and used for subsequent parametric analyses. Based on the numerical results, a failure probability function was established to assess the collapse probability of MDFRCs under varying excitation frequencies and peak ground acceleration (PGA) values. The results indicate that collapse probability increases with increasing PGA and decreasing excitation frequency. Moreover, tenon detachment was identified as a distinct failure mode in MDFRCs with shear keys, and an analytical approach was developed for its rapid identification. Overall, these findings provide a basis for the seismic assessment of MDFRCs with shear key connections.
- 5 July 2026
- Published by Wiley in Earthquake Spectra
- Vol. 42 (3)
Seismic Performance of Multidrum Free‐Rocking Columns With Shear Key
This study experimentally investigates the effects of shear keys on the seismic performance of multidrum free rocking columns (MDFRCs) by means of shaking table tests on two 1:18 specimens, one with and one without shear keys, taking classical stone column as found in the Parthenon as prototype reference. The shaking table test results show that shear keys can significantly reduce interdrum deformation; in the most pronounced case, the interdrum drift ratio at the capital was reduced from approximately 20% to 6%, corresponding to a relative reduction of more than 70%. Corresponding finite element (FE) models were then developed, validated against the experimental results, and used for subsequent parametric analyses. Based on the numerical results, a failure probability function was established to assess the collapse probability of MDFRCs under varying excitation frequencies and peak ground acceleration (PGA) values. The results indicate that collapse probability increases with increasing PGA and decreasing excitation frequency. Moreover, tenon detachment was identified as a distinct failure mode in MDFRCs with shear keys, and an analytical approach was developed for its rapid identification. Overall, these findings provide a basis for the seismic assessment of MDFRCs with shear key connections.
- 16 April 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (9) , 2065-2082
Shaking Table Tests of a Full‐Scale First‐Story Rocking Isolation System in ROBUST Project
To enhance seismic resilience of steel structures, this study proposes an innovative First‐Story Rocking Isolation System (FSRIS) and evaluates its dynamic performance through shaking table testing. Developed as part of the “RObust BUilding SysTem (ROBUST)” project, the FSRIS is designed to confine structural nonlinearity to the first story while protecting upper stories. Low‐damage rocking joints are implemented at upper and lower ends of the first‐story rocking columns, while the joints in the upper stories remain rigid. The test structure integrated two rocking isolation frames equipped with replaceable energy dissipation (ED) devices at the column ends, coupled with one gravity frame featuring simple shear connections. Under frequently occurring earthquakes (FOE), the FSRIS behave as a moment‐resisting frame. Beyond FOE intensity, the first‐story rocking mechanism is activated. The FSRIS was subjected to eight seismic excitations, with peak ground accelerations ranging from 0.055 g–0.62 g. White noise was employed to evaluate dynamic properties of the tested FSRIS before and after each excitation. Throughout the test sequence, the system exhibited exceptional self‐centering capability with negligible residual drifts and no visible damage. These findings validate the feasibility of the first‐story rocking concept within current design practices, offering a novel and effective low‐damage solution for the next generation of resilient structures.
- 16 April 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (9) , 2065-2082
Shaking Table Tests of a Full‐Scale First‐Story Rocking Isolation System in ROBUST Project
To enhance seismic resilience of steel structures, this study proposes an innovative First‐Story Rocking Isolation System (FSRIS) and evaluates its dynamic performance through shaking table testing. Developed as part of the “RObust BUilding SysTem (ROBUST)” project, the FSRIS is designed to confine structural nonlinearity to the first story while protecting upper stories. Low‐damage rocking joints are implemented at upper and lower ends of the first‐story rocking columns, while the joints in the upper stories remain rigid. The test structure integrated two rocking isolation frames equipped with replaceable energy dissipation (ED) devices at the column ends, coupled with one gravity frame featuring simple shear connections. Under frequently occurring earthquakes (FOE), the FSRIS behave as a moment‐resisting frame. Beyond FOE intensity, the first‐story rocking mechanism is activated. The FSRIS was subjected to eight seismic excitations, with peak ground accelerations ranging from 0.055 g–0.62 g. White noise was employed to evaluate dynamic properties of the tested FSRIS before and after each excitation. Throughout the test sequence, the system exhibited exceptional self‐centering capability with negligible residual drifts and no visible damage. These findings validate the feasibility of the first‐story rocking concept within current design practices, offering a novel and effective low‐damage solution for the next generation of resilient structures.
- Top Cited Papers
- 28 January 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (9) , 1769-1787
Shaking Table Behaviour of a Full‐Scale Three Storey Steel Rocking Structure With Tension‐Only Frictional Dissipators
A full‐scale three‐storey one‐bay‐by‐two‐bay steel rocking structure designed for the RObust BUilding SysTem (ROBUST) project consists of a central gravity frame (GF) and two exterior rocking frames (RFs) in the loading direction. Energy dissipation is provided by tension‐only friction dissipators and by moment connections in the beams extending from the central GF, which have the effect of partially restraining RF uplift. These beams, which span perpendicular to the loading direction, have nominally pinned connections adjacent to the exterior RFs and moment connections at the interface with the central GF. The moment connections on the two sides of the GF have different connection details with similar moment‐rotation loading characteristics but different unloading behaviour. Tests on the friction connection component of the tension‐only dissipators indicated that the sliding force varied during piecewise monotonic elongation. Shaking table tests with peak table accelerations up to 0.6 g exhibited RF uplift and showed the structure fully self‐centred with almost no damage. Despite similar loading characteristics, differences in unloading behaviour of the connections in the transverse beams on each side of the central GF caused significant floor plan torsion, and north and south RF peak absolute roof drifts of 0.92% and 0.42%, respectively. Three‐dimensional finite element model results matched the experimental behaviour well for the maximum applied shaking intensity. A parametric study using the experimental ground motion record showed roof displacements increased 54% due to the moment connection unloading difference, but this average value decreased to <8% considering multiple ground motion records.
- 28 January 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (9) , 1769-1787
Top Cited PapersShaking Table Behaviour of a Full‐Scale Three Storey Steel Rocking Structure With Tension‐Only Frictional Dissipators
A full‐scale three‐storey one‐bay‐by‐two‐bay steel rocking structure designed for the RObust BUilding SysTem (ROBUST) project consists of a central gravity frame (GF) and two exterior rocking frames (RFs) in the loading direction. Energy dissipation is provided by tension‐only friction dissipators and by moment connections in the beams extending from the central GF, which have the effect of partially restraining RF uplift. These beams, which span perpendicular to the loading direction, have nominally pinned connections adjacent to the exterior RFs and moment connections at the interface with the central GF. The moment connections on the two sides of the GF have different connection details with similar moment‐rotation loading characteristics but different unloading behaviour. Tests on the friction connection component of the tension‐only dissipators indicated that the sliding force varied during piecewise monotonic elongation. Shaking table tests with peak table accelerations up to 0.6 g exhibited RF uplift and showed the structure fully self‐centred with almost no damage. Despite similar loading characteristics, differences in unloading behaviour of the connections in the transverse beams on each side of the central GF caused significant floor plan torsion, and north and south RF peak absolute roof drifts of 0.92% and 0.42%, respectively. Three‐dimensional finite element model results matched the experimental behaviour well for the maximum applied shaking intensity. A parametric study using the experimental ground motion record showed roof displacements increased 54% due to the moment connection unloading difference, but this average value decreased to <8% considering multiple ground motion records.
- 7 October 2025
- Published by Springer Nature in Applied Intelligence
- Vol. 55 (15) , 1-16
Towards identification and explainable localization of slopes in autonomous excavation: a feature fused CAM approach
- 7 October 2025
- Published by Springer Nature in Applied Intelligence
- Vol. 55 (15) , 1-16
Towards identification and explainable localization of slopes in autonomous excavation: a feature fused CAM approach
- Open Access
Shake-Table Tests of a Three-Storey Steel Structure with Resilient Slip-Friction Joints (RSFJ)
Shake-table tests were conducted as part of the Robust Building Systems (ROBUST) program to evaluate and demonstrate the resilience of various structural concepts under earthquake excitations. This paper presents the results of 3 different configurations incorporating the Resilient Slip-Friction Joint (RSFJ) in: (1) tension-only braces (TOB), (2) tension-compression braces (TCB), and (3) moment-resisting frame (MRF) joints along the longitudinal direction. Each building configuration was subjected to the El Centro ground motion at increasing intensities, reaching a peak ground acceleration (PGA) of about 0.5 g. The peak displacements sustained were well within design values, with the top floor deflecting by 0.66%, 0.98% and 1.26% of the total height for the TOB, TCB and MRF systems respectively. The corresponding inter-storey drifts peaked at 0.87%, 1.11% and 1.62%. In all cases, the structures essentially self-centered with residual drifts limited to 0.03%. The floor accelerations observed in unidirectional tests were 0.67 g (TOB), 0.66 g (TCB) and 0.62 g (MRF). The spikes may occur during (a) direction reversal at peak Mode 1 amplitude, (b) under the influence of higher Mode 2, and/or (c) stiffness transition at the upright/plumb position. In bidirectional tests, torsion effects contributed to the largest acceleration recorded at 0.95 g (TCB). Unbalanced resistance/deformation of symmetric friction connections in the transverse direction led to the structure twisting and loading the longitudinal RSFJs unevenly. However, the effects on peak displacements were not significant and similar responses as unidirectional tests indicate effective performance under simultaneous out-of-plane shaking. The results demonstrate the RSFJ's ability to damp seismically induced vibrations and restore structures to their original, undeformed shape after earthquakes.
Open AccessShake-Table Tests of a Three-Storey Steel Structure with Resilient Slip-Friction Joints (RSFJ)
Shake-table tests were conducted as part of the Robust Building Systems (ROBUST) program to evaluate and demonstrate the resilience of various structural concepts under earthquake excitations. This paper presents the results of 3 different configurations incorporating the Resilient Slip-Friction Joint (RSFJ) in: (1) tension-only braces (TOB), (2) tension-compression braces (TCB), and (3) moment-resisting frame (MRF) joints along the longitudinal direction. Each building configuration was subjected to the El Centro ground motion at increasing intensities, reaching a peak ground acceleration (PGA) of about 0.5 g. The peak displacements sustained were well within design values, with the top floor deflecting by 0.66%, 0.98% and 1.26% of the total height for the TOB, TCB and MRF systems respectively. The corresponding inter-storey drifts peaked at 0.87%, 1.11% and 1.62%. In all cases, the structures essentially self-centered with residual drifts limited to 0.03%. The floor accelerations observed in unidirectional tests were 0.67 g (TOB), 0.66 g (TCB) and 0.62 g (MRF). The spikes may occur during (a) direction reversal at peak Mode 1 amplitude, (b) under the influence of higher Mode 2, and/or (c) stiffness transition at the upright/plumb position. In bidirectional tests, torsion effects contributed to the largest acceleration recorded at 0.95 g (TCB). Unbalanced resistance/deformation of symmetric friction connections in the transverse direction led to the structure twisting and loading the longitudinal RSFJs unevenly. However, the effects on peak displacements were not significant and similar responses as unidirectional tests indicate effective performance under simultaneous out-of-plane shaking. The results demonstrate the RSFJ's ability to damp seismically induced vibrations and restore structures to their original, undeformed shape after earthquakes.
- 3 July 2024
- Published by Springer Nature
- p. 607-616
Shake Table Testing of a Low-Damage Steel Frame Building Incorporating Asymmetric and Symmetric Friction Connections
- 3 July 2024
- Published by Springer Nature
- p. 607-616
Shake Table Testing of a Low-Damage Steel Frame Building Incorporating Asymmetric and Symmetric Friction Connections
- Open Access
- 29 June 2024
- Published by Atlantis Press SARL
- p. 458-466
Quasi-static Test of Pavilion-Type Timber Frame with Forked Column under Different Axial Compression Ratios
- 29 June 2024
- Published by Atlantis Press SARL
- p. 458-466
Open AccessQuasi-static Test of Pavilion-Type Timber Frame with Forked Column under Different Axial Compression Ratios
- Open Access
- 29 June 2024
- Published by Atlantis Press SARL
- p. 467-474
Experimental Analysis on Metal Friction Pairs for Symmetric Friction Connections
- 29 June 2024
- Published by Atlantis Press SARL
- p. 467-474
Open AccessExperimental Analysis on Metal Friction Pairs for Symmetric Friction Connections