Shaking Table Behaviour of a Full‐Scale Three Storey Steel Rocking Structure With Tension‐Only Frictional Dissipators
Top Cited Papers
- 28 January 2026
- journal article
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (9) , 1769-1787
Abstract
A full‐scale three‐storey one‐bay‐by‐two‐bay steel rocking structure designed for the RObust BUilding SysTem (ROBUST) project consists of a central gravity frame (GF) and two exterior rocking frames (RFs) in the loading direction. Energy dissipation is provided by tension‐only friction dissipators and by moment connections in the beams extending from the central GF, which have the effect of partially restraining RF uplift. These beams, which span perpendicular to the loading direction, have nominally pinned connections adjacent to the exterior RFs and moment connections at the interface with the central GF. The moment connections on the two sides of the GF have different connection details with similar moment‐rotation loading characteristics but different unloading behaviour. Tests on the friction connection component of the tension‐only dissipators indicated that the sliding force varied during piecewise monotonic elongation. Shaking table tests with peak table accelerations up to 0.6 g exhibited RF uplift and showed the structure fully self‐centred with almost no damage. Despite similar loading characteristics, differences in unloading behaviour of the connections in the transverse beams on each side of the central GF caused significant floor plan torsion, and north and south RF peak absolute roof drifts of 0.92% and 0.42%, respectively. Three‐dimensional finite element model results matched the experimental behaviour well for the maximum applied shaking intensity. A parametric study using the experimental ground motion record showed roof displacements increased 54% due to the moment connection unloading difference, but this average value decreased to <8% considering multiple ground motion records.Keywords
Funding Information
- QuakeCoRE
- University of Auckland
- University of Canterbury
- Auckland University of Technology, New Zealand
- Tongji University
This publication has 11 references indexed in Scilit:
- Experimental study on low-damage performance of Sliding Hinge JointSoil Dynamics and Earthquake Engineering, 2023
- Asymmetrical friction damper to improve seismic behavior of tension-only braces: An experimental and analytical studyEngineering Structures, 2022
- Seismic behaviour of symmetric friction connections for steel buildingsEngineering Structures, 2020
- Hysteretic Behaviour of Asymmetrical Friction Connections Using Brake Pads of D3923Structures, 2018
- Shake table testing and numerical simulation of a self‐centering energy dissipative braced frameEarthquake Engineering & Structural Dynamics, 2013
- Seismic response of steel structures with seesaw systems using viscoelastic dampersEarthquake Engineering & Structural Dynamics, 2012
- Shaking table tests on seismic response of steel braced frames with column upliftEarthquake Engineering & Structural Dynamics, 2006
- Steel frames with bracing mechanism and hysteretic dampersEarthquake Engineering & Structural Dynamics, 2003
- 8. Slotted Bolted Connection Energy DissipatorsEarthquake Spectra, 1993
- The Imperial Valley earthquakes of 1940*Bulletin of the Seismological Society of America, 1941