Hanne Laakso
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hanne Laakso has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Timo Liimatainen
Research Unit of Health Sciences and Technology, University of Oulu, Oulu, Finland
5 shared publications Jaakko Paasonen
A. I. Virtanen Institute for Molecular Sciences University of Eastern Finland Kuopio Finland
4 shared publicationsShalom Michaeli
Center for Magnetic Resonance Research, Deptartment of Radiology University of Minnesota Minneapolis Minnesota USA
4 shared publicationsLin Wu
Center for Magnetic Resonance Research, Deptartment of Radiology University of Minnesota Minneapolis Minnesota USA
3 shared publicationsOlli Gröhn
A. I. Virtanen Institute for Molecular Sciences University of Eastern Finland Kuopio Finland
3 shared publications- Silvia Mangia
Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA
3 shared publications
Latest Publications
- Open Access
- 17 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2335-2346
Simultaneous zero echo time fMRI of rat brain and spinal cord
Purpose: Functional assessments of the central nervous system (CNS) are essential for many areas of research. fMRI typically targets either the brain or the spinal cord, but usually not both, because of the obstacles associated with simultaneous image acquisitions from distant fields of view (FOVs) with conventional MRI. In this work, we establish a novel MRI approach that enables artifact‐free, quiet, simultaneous fMRI of both brain and spinal cord, avoiding the need for dynamic shimming procedures.Methods: We used zero TE Multi‐Band‐SWeep Imaging with Fourier Transformation (MB‐SWIFT) technique at 9.4 T in a simultaneous dual‐FOV configuration and two separate RF transmit‐receive surface coils. The first coil covered the rat brain, while the second was positioned approximately at the T13‐L1 level of the rat's spinal cord with copper shielding to minimize the coupling between the RF coils. Eight Sprague–Dawley rats were used for hindlimb stimulation fMRI studies.Results: Robust and specific activations were detected in both the brain and spinal cord during hindlimb stimulation at individual and group levels. The results established the feasibility of the novel approach for simultaneous functional assessment of the lumbar spinal cord and brain in rats.Conclusion: This study demonstrated the feasibility of a novel dual‐FOV fMRI approach based on zero‐TE MB‐SWIFT and set the stage for translation to humans. The methodology enables comprehensive functional CNS evaluations of great value in different conditions such as pain, spinal cord injury, neurodegenerative diseases, and aging.
- 17 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2335-2346
Open AccessSimultaneous zero echo time fMRI of rat brain and spinal cord
Purpose: Functional assessments of the central nervous system (CNS) are essential for many areas of research. fMRI typically targets either the brain or the spinal cord, but usually not both, because of the obstacles associated with simultaneous image acquisitions from distant fields of view (FOVs) with conventional MRI. In this work, we establish a novel MRI approach that enables artifact‐free, quiet, simultaneous fMRI of both brain and spinal cord, avoiding the need for dynamic shimming procedures.Methods: We used zero TE Multi‐Band‐SWeep Imaging with Fourier Transformation (MB‐SWIFT) technique at 9.4 T in a simultaneous dual‐FOV configuration and two separate RF transmit‐receive surface coils. The first coil covered the rat brain, while the second was positioned approximately at the T13‐L1 level of the rat's spinal cord with copper shielding to minimize the coupling between the RF coils. Eight Sprague–Dawley rats were used for hindlimb stimulation fMRI studies.Results: Robust and specific activations were detected in both the brain and spinal cord during hindlimb stimulation at individual and group levels. The results established the feasibility of the novel approach for simultaneous functional assessment of the lumbar spinal cord and brain in rats.Conclusion: This study demonstrated the feasibility of a novel dual‐FOV fMRI approach based on zero‐TE MB‐SWIFT and set the stage for translation to humans. The methodology enables comprehensive functional CNS evaluations of great value in different conditions such as pain, spinal cord injury, neurodegenerative diseases, and aging.
- Open Access
Simultaneous zero echo time fMRI of rat brain and spinal cord
Purpose Functional assessments of the central nervous system (CNS) are essential for many areas of research. Functional MRI (fMRI) typically targets either the brain or the spinal cord, but usually not both, due to the obstacles associated with simultaneous image acquisitions from distant fields of view (FOVs) with conventional MRI. In this work, we establish a novel MRI approach that enables artefact-free, quiet, simultaneous fMRI of both brain and spinal cord, avoiding the need for dynamic shimming procedures. Methods We utilized zero echo time (TE) Multi-Band-SWeep Imaging with Fourier Transformation (MB-SWIFT) technique at 9.4T in a simultaneous dual-FOV configuration and two separate radio frequency (RF) transmit-receive surface coils. The first coil covered the rat brain, while the second was positioned approximately at the T13-L1 level of the rat”s spinal cord with copper shielding to minimize the coupling between the RF coils. Eight Sprague–Dawley rats were used for hindlimb stimulation fMRI studies. Results Robust and specific activations were detected in both the brain and spinal cord during hind paw stimulation at individual and group levels. The results established the feasibility of the novel approach for simultaneous functional assessment of the lumbar spinal cord and brain in rats. Conclusion This study demonstrated the feasibility of a novel dual-FOV fMRI approach based on zero-TE MB-SWIFT and set the stage for translation to humans. The methodology enables comprehensive functional CNS evaluations of great value in different conditions such as pain, spinal cord injury, neurodegenerative diseases, and aging.
Open AccessSimultaneous zero echo time fMRI of rat brain and spinal cord
Purpose Functional assessments of the central nervous system (CNS) are essential for many areas of research. Functional MRI (fMRI) typically targets either the brain or the spinal cord, but usually not both, due to the obstacles associated with simultaneous image acquisitions from distant fields of view (FOVs) with conventional MRI. In this work, we establish a novel MRI approach that enables artefact-free, quiet, simultaneous fMRI of both brain and spinal cord, avoiding the need for dynamic shimming procedures. Methods We utilized zero echo time (TE) Multi-Band-SWeep Imaging with Fourier Transformation (MB-SWIFT) technique at 9.4T in a simultaneous dual-FOV configuration and two separate radio frequency (RF) transmit-receive surface coils. The first coil covered the rat brain, while the second was positioned approximately at the T13-L1 level of the rat”s spinal cord with copper shielding to minimize the coupling between the RF coils. Eight Sprague–Dawley rats were used for hindlimb stimulation fMRI studies. Results Robust and specific activations were detected in both the brain and spinal cord during hind paw stimulation at individual and group levels. The results established the feasibility of the novel approach for simultaneous functional assessment of the lumbar spinal cord and brain in rats. Conclusion This study demonstrated the feasibility of a novel dual-FOV fMRI approach based on zero-TE MB-SWIFT and set the stage for translation to humans. The methodology enables comprehensive functional CNS evaluations of great value in different conditions such as pain, spinal cord injury, neurodegenerative diseases, and aging.
- 5 January 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (6) , 2872-2884
Event‐recurring multiband SWIFT functional MRI with 200‐ms temporal resolution during deep brain stimulation and isoflurane‐induced burst suppression in rat
Purpose: To develop a high temporal resolution functional MRI method for tracking repeating events in the brain.Methods: We developed a novel functional MRI method using multiband sweep imaging with Fourier transformation (SWIFT), termed event‐recurring SWIFT (EVER‐SWIFT). The method is able to image similar repeating events with subsecond temporal resolution. Here, we demonstrate the use of EVER‐SWIFT for detecting functional MRI responses during deep brain stimulation of the medial septal nucleus and during spontaneous isoflurane‐induced burst suppression in the rat brain at 9.4 T with 200‐ms temporal resolution.Results: The EVER‐SWIFT approach showed that the shapes and time‐to‐peak values of the response curves to deep brain stimulation significantly differed between downstream brain regions connected to the medial septal nucleus, resembling findings obtained with traditional 2‐second temporal resolution. In contrast, EVER‐SWIFT allowed for detailed temporal measurement of a spontaneous isoflurane‐induced bursting activity pattern, which was not achieved with traditional temporal resolution.Conclusion: The EVER‐SWIFT technique enables subsecond 3D imaging of both stimulated and spontaneously recurring brain activities, and thus holds great potential for studying the mechanisms of neuromodulation and spontaneous brain activity.
- 5 January 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (6) , 2872-2884
Event‐recurring multiband SWIFT functional MRI with 200‐ms temporal resolution during deep brain stimulation and isoflurane‐induced burst suppression in rat
Purpose: To develop a high temporal resolution functional MRI method for tracking repeating events in the brain.Methods: We developed a novel functional MRI method using multiband sweep imaging with Fourier transformation (SWIFT), termed event‐recurring SWIFT (EVER‐SWIFT). The method is able to image similar repeating events with subsecond temporal resolution. Here, we demonstrate the use of EVER‐SWIFT for detecting functional MRI responses during deep brain stimulation of the medial septal nucleus and during spontaneous isoflurane‐induced burst suppression in the rat brain at 9.4 T with 200‐ms temporal resolution.Results: The EVER‐SWIFT approach showed that the shapes and time‐to‐peak values of the response curves to deep brain stimulation significantly differed between downstream brain regions connected to the medial septal nucleus, resembling findings obtained with traditional 2‐second temporal resolution. In contrast, EVER‐SWIFT allowed for detailed temporal measurement of a spontaneous isoflurane‐induced bursting activity pattern, which was not achieved with traditional temporal resolution.Conclusion: The EVER‐SWIFT technique enables subsecond 3D imaging of both stimulated and spontaneously recurring brain activities, and thus holds great potential for studying the mechanisms of neuromodulation and spontaneous brain activity.
- 1 August 2021
- Published by Elsevier in Atherosclerosis
- Vol. 331, e111
Chemokine receptor 5 antagonist, maraviroc, does not affect the progression of aortic stenosis in hypercholesterolemic mice
- 1 August 2021
- Published by Elsevier in Atherosclerosis
- Vol. 331, e111
Chemokine receptor 5 antagonist, maraviroc, does not affect the progression of aortic stenosis in hypercholesterolemic mice
- Open Access
- 18 May 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (4) , 2137-2145
Spinal cord fMRI with MB‐SWIFT for assessing epidural spinal cord stimulation in rats
Purpose: Electrical epidural spinal cord stimulation (SCS) is used as a treatment for chronic pain as well as to partially restore motor function after a spinal cord injury. Monitoring the spinal cord activity during SCS with fMRI could provide important and objective measures of integrative responses to treatment. Unfortunately, spinal cord fMRI is severely challenged by motion and susceptibility artifacts induced by the implanted electrode and bones. This pilot study introduces multi‐band sweep imaging with Fourier transformation (MB‐SWIFT) technique for spinal cord fMRI during SCS in rats. Given the close to zero acquisition delay and high bandwidth in 3 dimensions, MB‐SWIFT is demonstrated to be highly tolerant to motion and susceptibility‐induced artifacts and thus holds promise for fMRI during SCS.Methods: MB‐SWIFT with 0.78 × 0.78 × 1.50 mm3 spatial resolution and 3‐s temporal resolution was used at 9.4 Tesla in rats undergoing epidural SCS at different frequencies. Its performance was compared with spin echo EPI. The origin of the functional contrast was also explored using suppression bands.Results: MB‐SWIFT was tolerant to electrode‐induced artifacts and respiratory motion, leading to substantially higher fMRI sensitivity than spin echo fMRI. Clear stimulation frequency‐dependent responses to SCS were detected in the rat spinal cord close to the stimulation site. The origin of MB‐SWIFT fMRI signals was consistent with dominant inflow effects.Conclusion: fMRI of the rat spinal cord during SCS can be consistently achieved with MB‐SWIFT, thus providing a valuable experimental framework for assessing the effects of SCS on the central nervous system.
- 18 May 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (4) , 2137-2145
Open AccessSpinal cord fMRI with MB‐SWIFT for assessing epidural spinal cord stimulation in rats
Purpose: Electrical epidural spinal cord stimulation (SCS) is used as a treatment for chronic pain as well as to partially restore motor function after a spinal cord injury. Monitoring the spinal cord activity during SCS with fMRI could provide important and objective measures of integrative responses to treatment. Unfortunately, spinal cord fMRI is severely challenged by motion and susceptibility artifacts induced by the implanted electrode and bones. This pilot study introduces multi‐band sweep imaging with Fourier transformation (MB‐SWIFT) technique for spinal cord fMRI during SCS in rats. Given the close to zero acquisition delay and high bandwidth in 3 dimensions, MB‐SWIFT is demonstrated to be highly tolerant to motion and susceptibility‐induced artifacts and thus holds promise for fMRI during SCS.Methods: MB‐SWIFT with 0.78 × 0.78 × 1.50 mm3 spatial resolution and 3‐s temporal resolution was used at 9.4 Tesla in rats undergoing epidural SCS at different frequencies. Its performance was compared with spin echo EPI. The origin of the functional contrast was also explored using suppression bands.Results: MB‐SWIFT was tolerant to electrode‐induced artifacts and respiratory motion, leading to substantially higher fMRI sensitivity than spin echo fMRI. Clear stimulation frequency‐dependent responses to SCS were detected in the rat spinal cord close to the stimulation site. The origin of MB‐SWIFT fMRI signals was consistent with dominant inflow effects.Conclusion: fMRI of the rat spinal cord during SCS can be consistently achieved with MB‐SWIFT, thus providing a valuable experimental framework for assessing the effects of SCS on the central nervous system.
- Open Access
- 4 February 2021
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (4) , e4483
Docetaxel chemotherapy response in PC3 prostate cancer mouse model detected by rotating frame relaxations and water diffusion
MRI is a common method of prostate cancer diagnosis. Several MRI‐derived markers, including the apparent diffusion coefficient (ADC) based on diffusion‐weighted imaging, have been shown to provide values for prostate cancer detection and characterization. The hypothesis of the study was that docetaxel chemotherapy response could be picked up earlier with rotating frame relaxation times TRAFF2 and TRAFF4 than with the continuous wave T1ρ, adiabatic T1ρ, adiabatic T2ρ, T1, T2 or water ADC. Human PC3 prostate cancer cells expressing a red fluorescent protein were implanted in 21 male mice. Docetaxel chemotherapy was given once a week starting 1 week after cell implantation for 10 randomly selected mice, while the rest served as a control group (n = 11). The MRI consisted of relaxation along a fictitious field (RAFF) in the second (RAFF2) and fourth (RAFF4) rotating frames, T1 and T2, continuous wave T1ρ, adiabatic T1ρ and adiabatic T2ρ relaxation time measurements and water ADC. MRI was conducted at 7 T, once a week up to 4 weeks from cell implantation. The tumor volume was monitored using T2‐weighted MRI and optical imaging. The histology was evaluated after the last imaging time point. Significantly reduced RAFFn, T1ρ, T2ρ and conventional relaxation times 4 weeks after tumor implantation were observed in the treated tumors compared with the controls. The clearest short‐ and long‐term responses were obtained with T1, while no clear improvement in response to treatment was detected with novel methods compared with conventional methods or with RAFFn compared with all others. The tumor volume decreased after a two‐week time point for the treated group and increased significantly in the control group, which was supported by increasing red fluorescent light emission in the control tumors. Decreased relaxation times were associated with successful chemotherapy outcomes. The results indicate altered relaxation mechanisms compared with higher dose chemotherapies previously published.
- 4 February 2021
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (4) , e4483
Open AccessDocetaxel chemotherapy response in PC3 prostate cancer mouse model detected by rotating frame relaxations and water diffusion
MRI is a common method of prostate cancer diagnosis. Several MRI‐derived markers, including the apparent diffusion coefficient (ADC) based on diffusion‐weighted imaging, have been shown to provide values for prostate cancer detection and characterization. The hypothesis of the study was that docetaxel chemotherapy response could be picked up earlier with rotating frame relaxation times TRAFF2 and TRAFF4 than with the continuous wave T1ρ, adiabatic T1ρ, adiabatic T2ρ, T1, T2 or water ADC. Human PC3 prostate cancer cells expressing a red fluorescent protein were implanted in 21 male mice. Docetaxel chemotherapy was given once a week starting 1 week after cell implantation for 10 randomly selected mice, while the rest served as a control group (n = 11). The MRI consisted of relaxation along a fictitious field (RAFF) in the second (RAFF2) and fourth (RAFF4) rotating frames, T1 and T2, continuous wave T1ρ, adiabatic T1ρ and adiabatic T2ρ relaxation time measurements and water ADC. MRI was conducted at 7 T, once a week up to 4 weeks from cell implantation. The tumor volume was monitored using T2‐weighted MRI and optical imaging. The histology was evaluated after the last imaging time point. Significantly reduced RAFFn, T1ρ, T2ρ and conventional relaxation times 4 weeks after tumor implantation were observed in the treated tumors compared with the controls. The clearest short‐ and long‐term responses were obtained with T1, while no clear improvement in response to treatment was detected with novel methods compared with conventional methods or with RAFFn compared with all others. The tumor volume decreased after a two‐week time point for the treated group and increased significantly in the control group, which was supported by increasing red fluorescent light emission in the control tumors. Decreased relaxation times were associated with successful chemotherapy outcomes. The results indicate altered relaxation mechanisms compared with higher dose chemotherapies previously published.
- 21 May 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 32 (8) , e4108
Characterizing valve dynamics in mice by high‐resolution cine‐MRI
Aims: In calcific aortic valve disease (CAVD), progressive valvular sclerosis and calcification cause narrowing of the orifice and an impairment of the valve's function. We applied high‐resolution cine‐MRI to perform quantitative analysis of the dynamics of the aortic valve in a mice model of CAVD.Methods and Results: LDLr−/−ApoB100/100 mice were fed a Western diet (WD) or a standard diet (control) for 22 weeks. The mice were imaged in a 7 T horizontal MRI scanner, and aortic valve dynamics was examined by imaging the cross‐section of the aorta at valve level using cine sequences. From these images, the area of the aortic valve orifice was determined during the heart cycle. MRI results were compared with echocardiographic and histopathologic results. The data revealed evidence of clear aortic valve dysfunction in WD mice as compared with control mice (interaction P < 0.001). MRI showed narrowing (14%, P < 0.05) of the orifice area, and this was also seen in histology (34%, P < 0.05), indicating more severe aortic stenosis after WD than in controls. Additionally, MRI revealed a reduction in the ejection fraction (EF) (−11%, P < 0.01), a result confirmed with echocardiography (−27%, P < 0.001) in mice fed with WD. EF detected by MRI and echocardiography also correlated strongly with the degree of stenosis assessed by histology.Conclusions: Cine‐MRI can be used for quantitative analysis of the aortic valve orifice over the cardiac cycle in mice. MRI showed the cusps clearly, and we were able to detect aortic valve dysfunction over time through the cardiac cycle.
- 21 May 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 32 (8) , e4108
Characterizing valve dynamics in mice by high‐resolution cine‐MRI
Aims: In calcific aortic valve disease (CAVD), progressive valvular sclerosis and calcification cause narrowing of the orifice and an impairment of the valve's function. We applied high‐resolution cine‐MRI to perform quantitative analysis of the dynamics of the aortic valve in a mice model of CAVD.Methods and Results: LDLr−/−ApoB100/100 mice were fed a Western diet (WD) or a standard diet (control) for 22 weeks. The mice were imaged in a 7 T horizontal MRI scanner, and aortic valve dynamics was examined by imaging the cross‐section of the aorta at valve level using cine sequences. From these images, the area of the aortic valve orifice was determined during the heart cycle. MRI results were compared with echocardiographic and histopathologic results. The data revealed evidence of clear aortic valve dysfunction in WD mice as compared with control mice (interaction P < 0.001). MRI showed narrowing (14%, P < 0.05) of the orifice area, and this was also seen in histology (34%, P < 0.05), indicating more severe aortic stenosis after WD than in controls. Additionally, MRI revealed a reduction in the ejection fraction (EF) (−11%, P < 0.01), a result confirmed with echocardiography (−27%, P < 0.001) in mice fed with WD. EF detected by MRI and echocardiography also correlated strongly with the degree of stenosis assessed by histology.Conclusions: Cine‐MRI can be used for quantitative analysis of the aortic valve orifice over the cardiac cycle in mice. MRI showed the cusps clearly, and we were able to detect aortic valve dysfunction over time through the cardiac cycle.
- Open Access
- 1 October 2018
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 38 (10) , 2327-2337
Deletion of Lymphangiogenic and Angiogenic Growth Factor VEGF-D Leads to Severe Hyperlipidemia and Delayed Clearance of Chylomicron Remnants
Objective—: Dyslipidemia is one of the key factors behind coronary heart disease. Blood and lymphatic vessels play pivotal roles in both lipoprotein metabolism and development of atherosclerotic plaques. Recent studies have linked members of VEGF (vascular endothelial growth factor) family to lipid metabolism, but the function of VEGF-D has remained unexplored. Here, we investigated how the deletion of VEGF-D affects lipid and lipoprotein metabolism in atherogenic LDLR −/− ApoB 100/100 mice. Approach and Results—: Deletion of VEGF-D (VEGF-D −/− LDLR −/− ApoB 100/100 ) led to markedly elevated plasma cholesterol and triglyceride levels without an increase in atherogenesis. Size distribution and hepatic lipid uptake studies confirmed a delayed clearance of large chylomicron remnant particles that cannot easily penetrate through the vascular endothelium. Mechanistically, the inhibition of VEGF-D signaling significantly decreased the hepatic expression of SDC1 (syndecan 1), which is one of the main receptors for chylomicron remnant uptake when LDLR is absent. Immunohistochemical staining confirmed reduced expression of SDC1 in the sinusoidal surface of hepatocytes in VEGF-D deficient mice. Furthermore, hepatic RNA-sequencing revealed that VEGF-D is also an important regulator of genes related to lipid metabolism and inflammation. The lack of VEGF-D signaling via VEGFR3 (VEGF receptor 3) led to lowered expression of genes regulating triglyceride and cholesterol production, as well as downregulation of peroxisomal β-oxidation pathway. Conclusions—: These results demonstrate that VEGF-D, a powerful lymphangiogenic and angiogenic growth factor, is also a major regulator of chylomicron metabolism in mice.
- 1 October 2018
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 38 (10) , 2327-2337
Open AccessDeletion of Lymphangiogenic and Angiogenic Growth Factor VEGF-D Leads to Severe Hyperlipidemia and Delayed Clearance of Chylomicron Remnants
Objective—: Dyslipidemia is one of the key factors behind coronary heart disease. Blood and lymphatic vessels play pivotal roles in both lipoprotein metabolism and development of atherosclerotic plaques. Recent studies have linked members of VEGF (vascular endothelial growth factor) family to lipid metabolism, but the function of VEGF-D has remained unexplored. Here, we investigated how the deletion of VEGF-D affects lipid and lipoprotein metabolism in atherogenic LDLR −/− ApoB 100/100 mice. Approach and Results—: Deletion of VEGF-D (VEGF-D −/− LDLR −/− ApoB 100/100 ) led to markedly elevated plasma cholesterol and triglyceride levels without an increase in atherogenesis. Size distribution and hepatic lipid uptake studies confirmed a delayed clearance of large chylomicron remnant particles that cannot easily penetrate through the vascular endothelium. Mechanistically, the inhibition of VEGF-D signaling significantly decreased the hepatic expression of SDC1 (syndecan 1), which is one of the main receptors for chylomicron remnant uptake when LDLR is absent. Immunohistochemical staining confirmed reduced expression of SDC1 in the sinusoidal surface of hepatocytes in VEGF-D deficient mice. Furthermore, hepatic RNA-sequencing revealed that VEGF-D is also an important regulator of genes related to lipid metabolism and inflammation. The lack of VEGF-D signaling via VEGFR3 (VEGF receptor 3) led to lowered expression of genes regulating triglyceride and cholesterol production, as well as downregulation of peroxisomal β-oxidation pathway. Conclusions—: These results demonstrate that VEGF-D, a powerful lymphangiogenic and angiogenic growth factor, is also a major regulator of chylomicron metabolism in mice.
- Open Access
- 5 September 2018
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 296, 79-84
Capturing exchange using periodic radiofrequency irradiation
- 5 September 2018
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 296, 79-84
Open AccessCapturing exchange using periodic radiofrequency irradiation
- 23 March 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (5) , e3909
T2, T1ρ and TRAFF4 detect early regenerative changes in mouse ischemic skeletal muscle
The identification of areas with regenerative potential in ischemic tissues would allow the targeting of treatments supporting tissue recovery. The regeneration process involves the activation of several cellular and molecular responses which could be detected using magnetic resonance imaging (MRI). However, to date, magnetic resonance (MR) relaxation parameters have received little attention in the diagnosis and follow‐up of limb ischemia. The purpose of this study was to evaluate the feasibility of different MRI relaxation and diffusion tensor imaging parameters in the detection of areas showing early signs of regeneration in ischemic mouse skeletal muscles. T2 and T1ρ relaxation time constants, together with TRAFFn, T1 and diffusion tensor imaging, were evaluated to differentiate areas of regeneration in a mouse hind limb ischemia model before and 0, 1, 4, 7, 14 and 30 days after ischemia. All the measured relaxation times were longer in the areas of early regeneration compared with normal muscle tissue. The relaxation times increased after ischemia in the ischemic muscles, reaching a maximum at 4–7 days after occlusion, coinciding with the appearance of early signs of regeneration. Fractional anisotropy decreased significantly (p < 0.05) on days 1–4, whereas mean diffusivity, λ1 and λ2 decreased later, starting at day 7 after ischemia compared with the pre‐operational time point. The percentages of areas with different tissue morphologies were determined based on histological analysis of the ischemic muscle cross‐sections, and correlations between the percentages obtained and different relaxation times were calculated. The highest correlation between relaxation times and histology was achieved with T2, T1ρ and TRAFF4 (R2 = 0.96, R2 = 0.92 and R2 = 0.84, respectively, p < 0.01). Early regenerative changes were visible using T2, T1ρ and TRAFF4 MR relaxation time constants in skeletal muscle after ischemia. These markers could potentially be used for the identification of targets for therapies supporting muscle regeneration after ischemic injury.
- 23 March 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (5) , e3909
T2, T1ρ and TRAFF4 detect early regenerative changes in mouse ischemic skeletal muscle
The identification of areas with regenerative potential in ischemic tissues would allow the targeting of treatments supporting tissue recovery. The regeneration process involves the activation of several cellular and molecular responses which could be detected using magnetic resonance imaging (MRI). However, to date, magnetic resonance (MR) relaxation parameters have received little attention in the diagnosis and follow‐up of limb ischemia. The purpose of this study was to evaluate the feasibility of different MRI relaxation and diffusion tensor imaging parameters in the detection of areas showing early signs of regeneration in ischemic mouse skeletal muscles. T2 and T1ρ relaxation time constants, together with TRAFFn, T1 and diffusion tensor imaging, were evaluated to differentiate areas of regeneration in a mouse hind limb ischemia model before and 0, 1, 4, 7, 14 and 30 days after ischemia. All the measured relaxation times were longer in the areas of early regeneration compared with normal muscle tissue. The relaxation times increased after ischemia in the ischemic muscles, reaching a maximum at 4–7 days after occlusion, coinciding with the appearance of early signs of regeneration. Fractional anisotropy decreased significantly (p < 0.05) on days 1–4, whereas mean diffusivity, λ1 and λ2 decreased later, starting at day 7 after ischemia compared with the pre‐operational time point. The percentages of areas with different tissue morphologies were determined based on histological analysis of the ischemic muscle cross‐sections, and correlations between the percentages obtained and different relaxation times were calculated. The highest correlation between relaxation times and histology was achieved with T2, T1ρ and TRAFF4 (R2 = 0.96, R2 = 0.92 and R2 = 0.84, respectively, p < 0.01). Early regenerative changes were visible using T2, T1ρ and TRAFF4 MR relaxation time constants in skeletal muscle after ischemia. These markers could potentially be used for the identification of targets for therapies supporting muscle regeneration after ischemic injury.