Event‐recurring multiband SWIFT functional MRI with 200‐ms temporal resolution during deep brain stimulation and isoflurane‐induced burst suppression in rat
- 5 January 2022
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (6) , 2872-2884
Abstract
Purpose: To develop a high temporal resolution functional MRI method for tracking repeating events in the brain.Methods: We developed a novel functional MRI method using multiband sweep imaging with Fourier transformation (SWIFT), termed event‐recurring SWIFT (EVER‐SWIFT). The method is able to image similar repeating events with subsecond temporal resolution. Here, we demonstrate the use of EVER‐SWIFT for detecting functional MRI responses during deep brain stimulation of the medial septal nucleus and during spontaneous isoflurane‐induced burst suppression in the rat brain at 9.4 T with 200‐ms temporal resolution.Results: The EVER‐SWIFT approach showed that the shapes and time‐to‐peak values of the response curves to deep brain stimulation significantly differed between downstream brain regions connected to the medial septal nucleus, resembling findings obtained with traditional 2‐second temporal resolution. In contrast, EVER‐SWIFT allowed for detailed temporal measurement of a spontaneous isoflurane‐induced bursting activity pattern, which was not achieved with traditional temporal resolution.Conclusion: The EVER‐SWIFT technique enables subsecond 3D imaging of both stimulated and spontaneously recurring brain activities, and thus holds great potential for studying the mechanisms of neuromodulation and spontaneous brain activity.Keywords
Funding Information
- Jane ja Aatos Erkon Säätiö
- H2020 Marie Skłodowska-Curie Actions (691110)
- National Institutes of Health (P41EB027061, U01‐NS103569‐01)
This publication has 39 references indexed in Scilit:
- BOLD responses to different temporal frequency stimuli in the lateral geniculate nucleus and visual cortex: Insights into the neural basis of fMRINeuroImage, 2011
- Variable-density spiral-in/out functional magnetic resonance imagingMagnetic Resonance in Medicine, 2010
- Neurogenic hippocampal targets of deep brain stimulationJournal of Comparative Neurology, 2010
- Neural Origin of Spontaneous Hemodynamic Fluctuations in Rats under Burst-Suppression Anesthesia ConditionCerebral Cortex, 2010
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- Projection reconstruction MR imaging using FOCUSSMagnetic Resonance in Medicine, 2007
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Methodologic considerations for spiral k‐space functional MRIInternational Journal of Imaging Systems and Technology, 1995
- Functional MRI of human brain activation at high spatial resolutionMagnetic Resonance in Medicine, 1993