Djordje Stojic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Djordje Stojic has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Slavko Veinović
Univerzitet u Beogradu Elektrotehnički institut Nikola Tesla Koste Glavinića 8a 11000 Beograd Srbija
6 shared publications Milan Milinkovic
Electrical institute "Nikola Tesla", Belgrade, Serbia
5 shared publications- Tomasz Tarczewski
Nicolaus Copernicus University
5 shared publications - Tomislav B. Sekara
School of Electrical Engineering, University of Belgrade, Belgrade, Serbia
5 shared publications - Dušan Joksimović
Univerzitet u Beogradu Elektrotehnički institut Nikola Tesla Koste Glavinića 8a 11000 Beograd Srbija
4 shared publications Slavko Veinovic
Electrical Institute Nikola Tesla, University of Belgrade, Belgrade, Serbia
4 shared publications
Latest Publications
- 19 October 2025
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 13 (11) , 1-17
Active disturbance rejection control via transfer function implementation: an improved approach
- 19 October 2025
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 13 (11) , 1-17
Active disturbance rejection control via transfer function implementation: an improved approach
- Open Access
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 59339-59365
Reactive Power Controller for Under-Excitation Limiter With Regard to Electromechanical Oscillations
This paper presents a novel tuning algorithm for the adaptive reactive power (Var) PI controller as a control part of under-excitation limiter (UEL). The proposed algorithm is designed to adapt to changes in the synchronous generator (SG) plant dynamics without requiring prior knowledge of generator and system parameters. The algorithm is based on the reduced first-order linear plant model, whose parameters are estimated using the Recursive least-squares (RLS) algorithm. Considering that the SG is close to its stability limit when the UEL is operational, if the Var controller is not tuned well, the UEL can generate a negative damping torque on electromechanical oscillations and even lead to SG instability. The proposed algorithm solves this problem by targeting the specific frequency bandwidth of the Var control system that excludes the detected frequency of electromechanical oscillations. This mitigates the negative impact of the UEL on the damping of electromechanical oscillations and prevents overlapping of UEL action with the power system stabilizer (PSS) action. Once the plant model parameters are estimated, and the targeted control system frequency band is identified based on the measured electromechanical oscillation frequency, the controller parameters are tuned using pole-zero cancellation method. The effectiveness and performance of the proposed tuning procedure, encompassing online identification of reduced linear plant model parameters, online measurement of electromechanical oscillation frequency, and subsequent online tuning of the UEL Var controller, have been demonstrated through both simulation and experimental studies. Simulations utilized nonlinear and linear models of a 240 MVA SG connected to an infinite bus and Kundur’s two-area power system model. Experimental validation was conducted in a laboratory environment using a reduced-scale, low-power SG. Dynamic performance indices obtained from various test cases demonstrate the robustness and stability of the Var control system incorporating the UEL controller proposed in this paper.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 59339-59365
Open AccessReactive Power Controller for Under-Excitation Limiter With Regard to Electromechanical Oscillations
This paper presents a novel tuning algorithm for the adaptive reactive power (Var) PI controller as a control part of under-excitation limiter (UEL). The proposed algorithm is designed to adapt to changes in the synchronous generator (SG) plant dynamics without requiring prior knowledge of generator and system parameters. The algorithm is based on the reduced first-order linear plant model, whose parameters are estimated using the Recursive least-squares (RLS) algorithm. Considering that the SG is close to its stability limit when the UEL is operational, if the Var controller is not tuned well, the UEL can generate a negative damping torque on electromechanical oscillations and even lead to SG instability. The proposed algorithm solves this problem by targeting the specific frequency bandwidth of the Var control system that excludes the detected frequency of electromechanical oscillations. This mitigates the negative impact of the UEL on the damping of electromechanical oscillations and prevents overlapping of UEL action with the power system stabilizer (PSS) action. Once the plant model parameters are estimated, and the targeted control system frequency band is identified based on the measured electromechanical oscillation frequency, the controller parameters are tuned using pole-zero cancellation method. The effectiveness and performance of the proposed tuning procedure, encompassing online identification of reduced linear plant model parameters, online measurement of electromechanical oscillation frequency, and subsequent online tuning of the UEL Var controller, have been demonstrated through both simulation and experimental studies. Simulations utilized nonlinear and linear models of a 240 MVA SG connected to an infinite bus and Kundur’s two-area power system model. Experimental validation was conducted in a laboratory environment using a reduced-scale, low-power SG. Dynamic performance indices obtained from various test cases demonstrate the robustness and stability of the Var control system incorporating the UEL controller proposed in this paper.
- 19 February 2025
- Published by Springer Nature in Journal of Power Electronics
- p. 1-12
New robust resonant current controller design for grid-tied inverters with LLCL filters
- 19 February 2025
- Published by Springer Nature in Journal of Power Electronics
- p. 1-12
New robust resonant current controller design for grid-tied inverters with LLCL filters
- Open Access
- 8 January 2025
- Published by MDPI AG in Electronics
- Vol. 14 (2) , 232
Large Language Model-Based Tuning Assistant for Variable Speed PMSM Drive with Cascade Control Structure
A cascade control structure (CCS) is still the most commonly used control scheme in variable speed control (VSC) electrical drives with alternating current (AC) motors. Several tuning methods are used to select the coefficients of controllers applied in CCS. These approaches can be divided into analytical, empirical, and heuristic ones. Regardless of the tuning method used, there is still a question of whether the CCS is tuned optimally in terms of considered performance indicators to provide high-performance behavior of the electrical drive. Recently, artificial intelligence-based methods, e.g., swarm-based metaheuristic algorithms (SBMAs), have been extensively examined in this field, giving promising results. Moreover, the intensive development of artificial intelligence (AI) assistants based on large language models (LLMs) supporting decision-making processes is observed. Therefore, it is worth examining the ability of LLMs to tune the CCS in the VSC electrical drive. This paper investigates tuning methods for the cascade control structure equipped with PI-type current and angular velocity controllers for PMSM drive. Sets of CCS parameters from electrical engineers with different experiences are compared with reference solutions obtained by using the SBMA approach and LLMs. The novel LLM-based Tuning Assistant (TA) is developed and trained to improve the quality of responses. Obtained results are assessed regarding the drive performance, number of attempts, and time required to accomplish the considered task. A quantitative analysis of LLM-based solutions is also presented. The results indicate that AI-based tuning methods and the properly trained Tuning Assistant can significantly improve the performance of VSC electrical drives, while state-of-the-art LLMs do not guarantee high-performance drive operation.
- 8 January 2025
- Published by MDPI AG in Electronics
- Vol. 14 (2) , 232
Open AccessLarge Language Model-Based Tuning Assistant for Variable Speed PMSM Drive with Cascade Control Structure
A cascade control structure (CCS) is still the most commonly used control scheme in variable speed control (VSC) electrical drives with alternating current (AC) motors. Several tuning methods are used to select the coefficients of controllers applied in CCS. These approaches can be divided into analytical, empirical, and heuristic ones. Regardless of the tuning method used, there is still a question of whether the CCS is tuned optimally in terms of considered performance indicators to provide high-performance behavior of the electrical drive. Recently, artificial intelligence-based methods, e.g., swarm-based metaheuristic algorithms (SBMAs), have been extensively examined in this field, giving promising results. Moreover, the intensive development of artificial intelligence (AI) assistants based on large language models (LLMs) supporting decision-making processes is observed. Therefore, it is worth examining the ability of LLMs to tune the CCS in the VSC electrical drive. This paper investigates tuning methods for the cascade control structure equipped with PI-type current and angular velocity controllers for PMSM drive. Sets of CCS parameters from electrical engineers with different experiences are compared with reference solutions obtained by using the SBMA approach and LLMs. The novel LLM-based Tuning Assistant (TA) is developed and trained to improve the quality of responses. Obtained results are assessed regarding the drive performance, number of attempts, and time required to accomplish the considered task. A quantitative analysis of LLM-based solutions is also presented. The results indicate that AI-based tuning methods and the properly trained Tuning Assistant can significantly improve the performance of VSC electrical drives, while state-of-the-art LLMs do not guarantee high-performance drive operation.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- p. 73-77
Excitation systems for motor-generators in the Bajina Bašta pumped-storage hydropower plant
The Bajina Bašta hydropower plant and the Bajina Bašta pumped-storage hydropower plant in Perućac are the largest hydroelectric facilities built on the Drina River. The Bajina Bašta pumped-storage hydropower plant is of great importance to the Serbian power system due to its ability to operate in both generator and motor modes, which increases system flexibility in terms of production and consumption management. Periods of low electricity consumption are used to fill the upper reservoir by operating the plant in motor mode. When the system requires additional energy, the units switch to the opposite mode, and by releasing water from the higher-altitude reservoir, the turbines are driven to generate electricity. Also, due to its ability to quickly start and quickly change the operating mode from generator to motor and vice versa, this plant can quickly respond to system disturbances and replace any other unit in the Elektroprivreda Srbije system. Therefore, the revitalization of the Bajina Bašta pumped-storage hydropower plant, which should extend the lifespan of the units by several decades, is of great importance to the power system. In 2024, the first unit was revitalized, while the revitalization of the second unit is planned for 2025. The Nikola Tesla Institute participated in the revitalization by replacing the excitation systems. Within the energy part of the excitation system, components with top performance were installed: excitation transformers, switches, thyristor bridges, demagnetization equipment, etc. The basis of the control part of the excitation system consists of certified INTROL excitation regulators, within which sequential automats for all operating modes of the units were implemented: generator mode, motor mode, synchronous start, electric braking, and test for testing purposes. INTROL regulators enable various control modes: automatic stator voltage regulation, automatic reactive power regulation, and automatic power factor regulation, along with which limiter functions and a power system stabilizer were implemented. Thyristor bridges and excitation regulators are implemented redundantly in a 1+1 configuration. After installation and connection, the excitation system was adjusted and tested, which showed good system performance, enabling reliable and stable operation of the units in all operating modes with automatic limitation of operation within the limits defined by the operating diagram.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- p. 73-77
Excitation systems for motor-generators in the Bajina Bašta pumped-storage hydropower plant
The Bajina Bašta hydropower plant and the Bajina Bašta pumped-storage hydropower plant in Perućac are the largest hydroelectric facilities built on the Drina River. The Bajina Bašta pumped-storage hydropower plant is of great importance to the Serbian power system due to its ability to operate in both generator and motor modes, which increases system flexibility in terms of production and consumption management. Periods of low electricity consumption are used to fill the upper reservoir by operating the plant in motor mode. When the system requires additional energy, the units switch to the opposite mode, and by releasing water from the higher-altitude reservoir, the turbines are driven to generate electricity. Also, due to its ability to quickly start and quickly change the operating mode from generator to motor and vice versa, this plant can quickly respond to system disturbances and replace any other unit in the Elektroprivreda Srbije system. Therefore, the revitalization of the Bajina Bašta pumped-storage hydropower plant, which should extend the lifespan of the units by several decades, is of great importance to the power system. In 2024, the first unit was revitalized, while the revitalization of the second unit is planned for 2025. The Nikola Tesla Institute participated in the revitalization by replacing the excitation systems. Within the energy part of the excitation system, components with top performance were installed: excitation transformers, switches, thyristor bridges, demagnetization equipment, etc. The basis of the control part of the excitation system consists of certified INTROL excitation regulators, within which sequential automats for all operating modes of the units were implemented: generator mode, motor mode, synchronous start, electric braking, and test for testing purposes. INTROL regulators enable various control modes: automatic stator voltage regulation, automatic reactive power regulation, and automatic power factor regulation, along with which limiter functions and a power system stabilizer were implemented. Thyristor bridges and excitation regulators are implemented redundantly in a 1+1 configuration. After installation and connection, the excitation system was adjusted and tested, which showed good system performance, enabling reliable and stable operation of the units in all operating modes with automatic limitation of operation within the limits defined by the operating diagram.
- Open Access
- 30 December 2024
- Published by MDPI AG in Preprints.org
Large Language Model-Based Tuning Assistant for Variable Speed PMSM Drive with Cascade Control Structure
A cascade control structure (CCS) is still the most commonly used control scheme in variable speed control (VSC) electrical drives with alternating current (AC) motors. Several tuning methods are used to select the coefficients of controllers applied in CCS. These approaches can be divided into analytical, empirical, and heuristic ones. Regardless of the tuning method used, there is still a question of whether the CCS is tuned optimally in terms of considered performance indicators to provide high-performance behavior of the electrical drive. Recently, artificial intelligence-based methods, e.g., swarm-based metaheuristic algorithms (SBMA), have been extensively examined in this field, giving promising results. Moreover, the intensive development of artificial intelligence (AI) assistants based on large language models (LLMs) supporting decision-making processes is observed. Therefore, it is worth examining the ability of LLMs to tune the CCS in the VSC electrical drive. This paper investigates tuning methods for the cascade control structure equipped with PI-type current and angular velocity controllers for PMSM drive. Sets of CCS parameters from electrical engineers with different experiences are compared with reference solutions obtained by using the SBMA approach and LLMs. The novel LLM-based Tuning Assistant (TA) is developed and trained to improve the quality of responses. Obtained results are assessed regarding the drive performance, number of attempts, and time required to accomplish the considered task. A quantitative analysis of LLM-based solutions is also presented. The results indicate that AI-based tuning methods and the properly trained Tuning Assistant can significantly improve the performance of VSC electrical drives, while state-of-the-art LLMs do not guarantee high-performance drive operation.
- 30 December 2024
- Published by MDPI AG in Preprints.org
Open AccessLarge Language Model-Based Tuning Assistant for Variable Speed PMSM Drive with Cascade Control Structure
A cascade control structure (CCS) is still the most commonly used control scheme in variable speed control (VSC) electrical drives with alternating current (AC) motors. Several tuning methods are used to select the coefficients of controllers applied in CCS. These approaches can be divided into analytical, empirical, and heuristic ones. Regardless of the tuning method used, there is still a question of whether the CCS is tuned optimally in terms of considered performance indicators to provide high-performance behavior of the electrical drive. Recently, artificial intelligence-based methods, e.g., swarm-based metaheuristic algorithms (SBMA), have been extensively examined in this field, giving promising results. Moreover, the intensive development of artificial intelligence (AI) assistants based on large language models (LLMs) supporting decision-making processes is observed. Therefore, it is worth examining the ability of LLMs to tune the CCS in the VSC electrical drive. This paper investigates tuning methods for the cascade control structure equipped with PI-type current and angular velocity controllers for PMSM drive. Sets of CCS parameters from electrical engineers with different experiences are compared with reference solutions obtained by using the SBMA approach and LLMs. The novel LLM-based Tuning Assistant (TA) is developed and trained to improve the quality of responses. Obtained results are assessed regarding the drive performance, number of attempts, and time required to accomplish the considered task. A quantitative analysis of LLM-based solutions is also presented. The results indicate that AI-based tuning methods and the properly trained Tuning Assistant can significantly improve the performance of VSC electrical drives, while state-of-the-art LLMs do not guarantee high-performance drive operation.
- Open Access
- 25 January 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 157
Novel tuning rules for PIDC controllers in automatic voltage regulation systems under constraints on robustness and sensitivity to measurement noise
- 25 January 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 157
Open AccessNovel tuning rules for PIDC controllers in automatic voltage regulation systems under constraints on robustness and sensitivity to measurement noise
- Open Access
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Predavanja,p. 44-45
INTROL-22 Synchronous generator automatic voltage regulator
The lecture presents the solutions applied in the current version INTROL-22 of the automatic voltage regulator (AVR) of the synchronous generator of the Nikola Tesla Institute of Electrical Engineering. In addition to the standard solutions defined by the current state of the art, the improved solution also contains algorithms that enable the application of AVR in the conditions of power facilities in power systems with remote nodes, as well as with a transmission system sensitive to transient instabilities and disturbances such as short circuits and frequent outages of parts of the system. The developed AVR also includes improved software for identifying the dynamic characteristics of the regulation system, for setting the parameters of voltage regulators, limiters and stabilizers of the power system, as well as for monitoring the variable states of the AVR in real time via a high-speed RS485 serial connection, and with specialized industrial communication protocols based on Ethernet.
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Predavanja,p. 44-45
Open AccessINTROL-22 Synchronous generator automatic voltage regulator
The lecture presents the solutions applied in the current version INTROL-22 of the automatic voltage regulator (AVR) of the synchronous generator of the Nikola Tesla Institute of Electrical Engineering. In addition to the standard solutions defined by the current state of the art, the improved solution also contains algorithms that enable the application of AVR in the conditions of power facilities in power systems with remote nodes, as well as with a transmission system sensitive to transient instabilities and disturbances such as short circuits and frequent outages of parts of the system. The developed AVR also includes improved software for identifying the dynamic characteristics of the regulation system, for setting the parameters of voltage regulators, limiters and stabilizers of the power system, as well as for monitoring the variable states of the AVR in real time via a high-speed RS485 serial connection, and with specialized industrial communication protocols based on Ethernet.