Slavko Veinović
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Slavko Veinović has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Djordje Stojic
Electrical Institute “Nikola Tesla”, University of Belgrade, Serbia
6 shared publications - Dušan Joksimović
Univerzitet u Beogradu Elektrotehnički institut Nikola Tesla Koste Glavinića 8a 11000 Beograd Srbija
5 shared publications - Luka Ivanović
Univerzitet u Beogradu Elektrotehnički institut Nikola Tesla Koste Glavinića 8a 11000 Beograd Srbija
4 shared publications - Ilija Klasnić
Univerzitet u Beogradu Elektrotehnički institut Nikola Tesla Koste Glavinića 8a 11000 Beograd Srbija
3 shared publications - Nemanja Milojčić
Електротехнички институт Никола Тесла
2 shared publications - Zoran Ćirić
Електротехнички институт Никола Тесла
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Scientific-Professional Society for Disaster Risk Management in Електропривреда = Electric Power Industry Journal
- Vol. 4 (2) , 93-113
Структура и динамичке перформансе редундантних система побуде мотор-генератора у РХЕ „Бајина Башта”
Проточна хидроелектрана и реверзибилна хидроелектрана (РХЕ) „Бајина Башта” у Перућцу представљају највеће хидроенергетске објекте изграђене на реци Дрини. РХЕ „Бајина Башта” има велики значај за електроенергетски систем Србије због могућности рада у генераторском и моторном режиму, чиме повећава флексибилност система са аспекта управљања производњом и потрошњом. Такође, због своје могућности да брзо стартује и брзо промени режим рада из генераторског у моторни и обрнуто, ова електрана може брзо да реагује на поремећаје у систему и замени било који други агрегат у систему „Електропривреде Србије”. Самим тим, и ревитализација РХЕ „Бајина Башта”, која треба да продужи животни век агрегата за неколико деценија, има велики значај за електроенергетски систем. Током 2024. ревитализован је први агрегат, док је ревитализација другог агрегата завршена 2026. У оквиру ревитализације су замењени и комплетни побудни системи. У оквиру енергетског дела система побуде уграђене су квалитетне компоненте: побудни трансформатори, прекидачи, тиристорски мостови, опрема за демагнетизацију итд. Основу управљачког дела система побуде чине сертификовани дигитални регулатори побуде у оквиру којих су реализовани секвентни аутомати за све режиме рада агрегата: генераторски режим, моторни режим, синхрони старт и електрично кочење. Регулатори омогућавају различите режиме регулације: аутоматска регулација напона статора, реактивне снаге или фактора снаге уз интегрисане лимитерске функције и стабилизатор електроенергетског система. Поузданост система додатно је осигурана редундантном имплементацијом тиристорских мостова и регулатора побуде у конфигурацији 1+1. Након завршене монтаже и повезивања комплетне опреме, спроведена су детаљна подешавања и испитивања система побуде, која су показала добре перформансе система. Ово гарантује поуздан и стабилан рад агрегата у свим предвиђеним режимима, уз аутоматско ограничење рада унутар дефинисаних граница погонског дијаграма.
- 1 January 2026
- Published by Scientific-Professional Society for Disaster Risk Management in Електропривреда = Electric Power Industry Journal
- Vol. 4 (2) , 93-113
Open AccessСтруктура и динамичке перформансе редундантних система побуде мотор-генератора у РХЕ „Бајина Башта”
Проточна хидроелектрана и реверзибилна хидроелектрана (РХЕ) „Бајина Башта” у Перућцу представљају највеће хидроенергетске објекте изграђене на реци Дрини. РХЕ „Бајина Башта” има велики значај за електроенергетски систем Србије због могућности рада у генераторском и моторном режиму, чиме повећава флексибилност система са аспекта управљања производњом и потрошњом. Такође, због своје могућности да брзо стартује и брзо промени режим рада из генераторског у моторни и обрнуто, ова електрана може брзо да реагује на поремећаје у систему и замени било који други агрегат у систему „Електропривреде Србије”. Самим тим, и ревитализација РХЕ „Бајина Башта”, која треба да продужи животни век агрегата за неколико деценија, има велики значај за електроенергетски систем. Током 2024. ревитализован је први агрегат, док је ревитализација другог агрегата завршена 2026. У оквиру ревитализације су замењени и комплетни побудни системи. У оквиру енергетског дела система побуде уграђене су квалитетне компоненте: побудни трансформатори, прекидачи, тиристорски мостови, опрема за демагнетизацију итд. Основу управљачког дела система побуде чине сертификовани дигитални регулатори побуде у оквиру којих су реализовани секвентни аутомати за све режиме рада агрегата: генераторски режим, моторни режим, синхрони старт и електрично кочење. Регулатори омогућавају различите режиме регулације: аутоматска регулација напона статора, реактивне снаге или фактора снаге уз интегрисане лимитерске функције и стабилизатор електроенергетског система. Поузданост система додатно је осигурана редундантном имплементацијом тиристорских мостова и регулатора побуде у конфигурацији 1+1. Након завршене монтаже и повезивања комплетне опреме, спроведена су детаљна подешавања и испитивања система побуде, која су показала добре перформансе система. Ово гарантује поуздан и стабилан рад агрегата у свим предвиђеним режимима, уз аутоматско ограничење рада унутар дефинисаних граница погонског дијаграма.
- Open Access
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 59339-59365
Reactive Power Controller for Under-Excitation Limiter With Regard to Electromechanical Oscillations
This paper presents a novel tuning algorithm for the adaptive reactive power (Var) PI controller as a control part of under-excitation limiter (UEL). The proposed algorithm is designed to adapt to changes in the synchronous generator (SG) plant dynamics without requiring prior knowledge of generator and system parameters. The algorithm is based on the reduced first-order linear plant model, whose parameters are estimated using the Recursive least-squares (RLS) algorithm. Considering that the SG is close to its stability limit when the UEL is operational, if the Var controller is not tuned well, the UEL can generate a negative damping torque on electromechanical oscillations and even lead to SG instability. The proposed algorithm solves this problem by targeting the specific frequency bandwidth of the Var control system that excludes the detected frequency of electromechanical oscillations. This mitigates the negative impact of the UEL on the damping of electromechanical oscillations and prevents overlapping of UEL action with the power system stabilizer (PSS) action. Once the plant model parameters are estimated, and the targeted control system frequency band is identified based on the measured electromechanical oscillation frequency, the controller parameters are tuned using pole-zero cancellation method. The effectiveness and performance of the proposed tuning procedure, encompassing online identification of reduced linear plant model parameters, online measurement of electromechanical oscillation frequency, and subsequent online tuning of the UEL Var controller, have been demonstrated through both simulation and experimental studies. Simulations utilized nonlinear and linear models of a 240 MVA SG connected to an infinite bus and Kundur’s two-area power system model. Experimental validation was conducted in a laboratory environment using a reduced-scale, low-power SG. Dynamic performance indices obtained from various test cases demonstrate the robustness and stability of the Var control system incorporating the UEL controller proposed in this paper.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 59339-59365
Open AccessReactive Power Controller for Under-Excitation Limiter With Regard to Electromechanical Oscillations
This paper presents a novel tuning algorithm for the adaptive reactive power (Var) PI controller as a control part of under-excitation limiter (UEL). The proposed algorithm is designed to adapt to changes in the synchronous generator (SG) plant dynamics without requiring prior knowledge of generator and system parameters. The algorithm is based on the reduced first-order linear plant model, whose parameters are estimated using the Recursive least-squares (RLS) algorithm. Considering that the SG is close to its stability limit when the UEL is operational, if the Var controller is not tuned well, the UEL can generate a negative damping torque on electromechanical oscillations and even lead to SG instability. The proposed algorithm solves this problem by targeting the specific frequency bandwidth of the Var control system that excludes the detected frequency of electromechanical oscillations. This mitigates the negative impact of the UEL on the damping of electromechanical oscillations and prevents overlapping of UEL action with the power system stabilizer (PSS) action. Once the plant model parameters are estimated, and the targeted control system frequency band is identified based on the measured electromechanical oscillation frequency, the controller parameters are tuned using pole-zero cancellation method. The effectiveness and performance of the proposed tuning procedure, encompassing online identification of reduced linear plant model parameters, online measurement of electromechanical oscillation frequency, and subsequent online tuning of the UEL Var controller, have been demonstrated through both simulation and experimental studies. Simulations utilized nonlinear and linear models of a 240 MVA SG connected to an infinite bus and Kundur’s two-area power system model. Experimental validation was conducted in a laboratory environment using a reduced-scale, low-power SG. Dynamic performance indices obtained from various test cases demonstrate the robustness and stability of the Var control system incorporating the UEL controller proposed in this paper.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- p. 73-77
Excitation systems for motor-generators in the Bajina Bašta pumped-storage hydropower plant
The Bajina Bašta hydropower plant and the Bajina Bašta pumped-storage hydropower plant in Perućac are the largest hydroelectric facilities built on the Drina River. The Bajina Bašta pumped-storage hydropower plant is of great importance to the Serbian power system due to its ability to operate in both generator and motor modes, which increases system flexibility in terms of production and consumption management. Periods of low electricity consumption are used to fill the upper reservoir by operating the plant in motor mode. When the system requires additional energy, the units switch to the opposite mode, and by releasing water from the higher-altitude reservoir, the turbines are driven to generate electricity. Also, due to its ability to quickly start and quickly change the operating mode from generator to motor and vice versa, this plant can quickly respond to system disturbances and replace any other unit in the Elektroprivreda Srbije system. Therefore, the revitalization of the Bajina Bašta pumped-storage hydropower plant, which should extend the lifespan of the units by several decades, is of great importance to the power system. In 2024, the first unit was revitalized, while the revitalization of the second unit is planned for 2025. The Nikola Tesla Institute participated in the revitalization by replacing the excitation systems. Within the energy part of the excitation system, components with top performance were installed: excitation transformers, switches, thyristor bridges, demagnetization equipment, etc. The basis of the control part of the excitation system consists of certified INTROL excitation regulators, within which sequential automats for all operating modes of the units were implemented: generator mode, motor mode, synchronous start, electric braking, and test for testing purposes. INTROL regulators enable various control modes: automatic stator voltage regulation, automatic reactive power regulation, and automatic power factor regulation, along with which limiter functions and a power system stabilizer were implemented. Thyristor bridges and excitation regulators are implemented redundantly in a 1+1 configuration. After installation and connection, the excitation system was adjusted and tested, which showed good system performance, enabling reliable and stable operation of the units in all operating modes with automatic limitation of operation within the limits defined by the operating diagram.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- p. 73-77
Excitation systems for motor-generators in the Bajina Bašta pumped-storage hydropower plant
The Bajina Bašta hydropower plant and the Bajina Bašta pumped-storage hydropower plant in Perućac are the largest hydroelectric facilities built on the Drina River. The Bajina Bašta pumped-storage hydropower plant is of great importance to the Serbian power system due to its ability to operate in both generator and motor modes, which increases system flexibility in terms of production and consumption management. Periods of low electricity consumption are used to fill the upper reservoir by operating the plant in motor mode. When the system requires additional energy, the units switch to the opposite mode, and by releasing water from the higher-altitude reservoir, the turbines are driven to generate electricity. Also, due to its ability to quickly start and quickly change the operating mode from generator to motor and vice versa, this plant can quickly respond to system disturbances and replace any other unit in the Elektroprivreda Srbije system. Therefore, the revitalization of the Bajina Bašta pumped-storage hydropower plant, which should extend the lifespan of the units by several decades, is of great importance to the power system. In 2024, the first unit was revitalized, while the revitalization of the second unit is planned for 2025. The Nikola Tesla Institute participated in the revitalization by replacing the excitation systems. Within the energy part of the excitation system, components with top performance were installed: excitation transformers, switches, thyristor bridges, demagnetization equipment, etc. The basis of the control part of the excitation system consists of certified INTROL excitation regulators, within which sequential automats for all operating modes of the units were implemented: generator mode, motor mode, synchronous start, electric braking, and test for testing purposes. INTROL regulators enable various control modes: automatic stator voltage regulation, automatic reactive power regulation, and automatic power factor regulation, along with which limiter functions and a power system stabilizer were implemented. Thyristor bridges and excitation regulators are implemented redundantly in a 1+1 configuration. After installation and connection, the excitation system was adjusted and tested, which showed good system performance, enabling reliable and stable operation of the units in all operating modes with automatic limitation of operation within the limits defined by the operating diagram.
- Open Access
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 35,p. 33-47
A 120 kVA uninterrupted power supply system in Kostolac A thermal power plant: Inverters in parallel operation
Uninterruptible Power Supply (UPS) systems are of vital importance for many consumers in complex facilities such as a thermal power plant. This paper presents a solution for the parallel operation of two inverters with nominal powers of 60 kVA, based on controlling the nature of the inverters. All challenges and technical details of parallelizing the two inverters are presented, from uniform load sharing and communication to establishing a "master-slave" relationship, and even the transient phenomena during the failure of one of the inverters. Detailed simulations of all relevant events and phenomena are simulated using the Plecs software tool. In accordance with the calculations, the inverters were developed, and experimental results of the operation of these inverters under simulated operational conditions are also included.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 35,p. 33-47
Open AccessA 120 kVA uninterrupted power supply system in Kostolac A thermal power plant: Inverters in parallel operation
Uninterruptible Power Supply (UPS) systems are of vital importance for many consumers in complex facilities such as a thermal power plant. This paper presents a solution for the parallel operation of two inverters with nominal powers of 60 kVA, based on controlling the nature of the inverters. All challenges and technical details of parallelizing the two inverters are presented, from uniform load sharing and communication to establishing a "master-slave" relationship, and even the transient phenomena during the failure of one of the inverters. Detailed simulations of all relevant events and phenomena are simulated using the Plecs software tool. In accordance with the calculations, the inverters were developed, and experimental results of the operation of these inverters under simulated operational conditions are also included.
- Open Access
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 34,p. 37-48
Modification of the implementation of the underexcitation limiter within the generator excitation system of Unit B1 at TPP "Nikola Tesla B"
This paper investigates a grid outage event at TPP "Nikola Tesla B" Unit B1 and analyzes the excitation system's response. Based on this analysis, modifications were made to the underexcitation limiter within the excitation system. The paper details the structure of the multi-segment straight-line limiter and its implementation methodology. The limiter's implementation was refined using recordings of the outage event and a detailed analysis of the excitation system's behavior. Additionally, the paper discusses the filtering of input measurements (stator voltage and generator active power) and the variable gain mechanism of the limiter. Finally, the paper presents the results of testing the modified limiter during grid operation, demonstrating stable behavior with damped oscillations.
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 34,p. 37-48
Open AccessModification of the implementation of the underexcitation limiter within the generator excitation system of Unit B1 at TPP "Nikola Tesla B"
This paper investigates a grid outage event at TPP "Nikola Tesla B" Unit B1 and analyzes the excitation system's response. Based on this analysis, modifications were made to the underexcitation limiter within the excitation system. The paper details the structure of the multi-segment straight-line limiter and its implementation methodology. The limiter's implementation was refined using recordings of the outage event and a detailed analysis of the excitation system's behavior. Additionally, the paper discusses the filtering of input measurements (stator voltage and generator active power) and the variable gain mechanism of the limiter. Finally, the paper presents the results of testing the modified limiter during grid operation, demonstrating stable behavior with damped oscillations.
- Open Access
- 1 January 2023
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 33,p. 75-89
Parameter selection and analysis of dynamic characteristics of an under-excitation limiter using a computer model
This paper presents a method for selecting parameters and analyzing the dynamic characteristics of a under-excitation excitation limiter using a computer model. The parameters are determined using the pole cancellation method for the worst-case operating regime from the perspective of the under-excitation limiter to ensure stability in all operating regimes. The analysis of the dynamic characteristics presented in the paper first obtained the time responses and frequency characteristics of the excitation control system when the limiter is active. Based on these, the values of dynamic performance indicies that indicate the quality of regulation are determined. The paper also provides a brief description of the implementation of the limiter and the computer models used in the analysis.
- 1 January 2023
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 33,p. 75-89
Open AccessParameter selection and analysis of dynamic characteristics of an under-excitation limiter using a computer model
This paper presents a method for selecting parameters and analyzing the dynamic characteristics of a under-excitation excitation limiter using a computer model. The parameters are determined using the pole cancellation method for the worst-case operating regime from the perspective of the under-excitation limiter to ensure stability in all operating regimes. The analysis of the dynamic characteristics presented in the paper first obtained the time responses and frequency characteristics of the excitation control system when the limiter is active. Based on these, the values of dynamic performance indicies that indicate the quality of regulation are determined. The paper also provides a brief description of the implementation of the limiter and the computer models used in the analysis.
- 27 September 2022
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 145
Optimized PIDD2 controller for AVR systems regarding robustness
- 27 September 2022
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 145
Optimized PIDD2 controller for AVR systems regarding robustness
- Open Access
- 1 January 2022
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 32,p. 53-72
Computer model analysis of dynamic performances of the excitation control system when the load angle limiter is active
A load angle limiter was implemented as an additional function in the existing excitation system to enable the operation of the synchronous generator in the entire P-Q diagram according to the recommendation of the manufacturer of the unit B2 synchronous generator in the "Nikola Tesla B" TPP. The analysis of dynamic performance presented in this paper consists of determining the time responses and frequency characteristics of the excitation control system when the load angle limiter is active, based on which the values of the dynamic performance indexes were obtained. In addition, the paper also provides a brief description of the implementation of the limiter, as well as a description of the computer models used in the analysis.
- 1 January 2022
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 32,p. 53-72
Open AccessComputer model analysis of dynamic performances of the excitation control system when the load angle limiter is active
A load angle limiter was implemented as an additional function in the existing excitation system to enable the operation of the synchronous generator in the entire P-Q diagram according to the recommendation of the manufacturer of the unit B2 synchronous generator in the "Nikola Tesla B" TPP. The analysis of dynamic performance presented in this paper consists of determining the time responses and frequency characteristics of the excitation control system when the load angle limiter is active, based on which the values of the dynamic performance indexes were obtained. In addition, the paper also provides a brief description of the implementation of the limiter, as well as a description of the computer models used in the analysis.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Modified Synchronous Reference Frame Based Hysteresis Current Controller
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Modified Synchronous Reference Frame Based Hysteresis Current Controller
- Open Access
- 13 March 2019
- Published by National and University Library of the Republic of Srpska in IJEEC - International Journal of Electrical Engineering and Computing
- Vol. 2 (1)
Optimization Possibilities for DC Current Transformer
The paper analyzes the consumption performance of DC current transformers based on linear class B, and half bridge classD compensation amplifiers, as well as self-oscillating flux gate current transformers based on push-pull and source–sink output stages.Compensation amplifiers, push-pull and source-sink output stages are used to generate feedback current in order to compensatemagnetic flux in the magnetic concentrator core, produced by electrical current flowing through a conductor under measurement. Thefocus of the analysis is the investigation of conditions for appearance of the bus-pumping effect to which all switching versions of DCcurrent transformers are prone. All sufficient conditions for bus pumping effect appearance are explained for the most critical case ofDC current measurement; the main issues are analyzed, giving better insight to power consumption, and possible hazards to DCcurrent transformer circuitry. It is highlighted the existence of particular exploitation conditions that lead to the state where the class Dbased DC transformers are inferior to conventional class B based counterparts. Finally, when a linear compensating amplifier isreplaced with a switching counterpart, it has been demonstrated that it is possible to expect a feasible improvement in energyconsumption in the middle of the ideal half-class D class and classical B class realisations.
- 13 March 2019
- Published by National and University Library of the Republic of Srpska in IJEEC - International Journal of Electrical Engineering and Computing
- Vol. 2 (1)
Open AccessOptimization Possibilities for DC Current Transformer
The paper analyzes the consumption performance of DC current transformers based on linear class B, and half bridge classD compensation amplifiers, as well as self-oscillating flux gate current transformers based on push-pull and source–sink output stages.Compensation amplifiers, push-pull and source-sink output stages are used to generate feedback current in order to compensatemagnetic flux in the magnetic concentrator core, produced by electrical current flowing through a conductor under measurement. Thefocus of the analysis is the investigation of conditions for appearance of the bus-pumping effect to which all switching versions of DCcurrent transformers are prone. All sufficient conditions for bus pumping effect appearance are explained for the most critical case ofDC current measurement; the main issues are analyzed, giving better insight to power consumption, and possible hazards to DCcurrent transformer circuitry. It is highlighted the existence of particular exploitation conditions that lead to the state where the class Dbased DC transformers are inferior to conventional class B based counterparts. Finally, when a linear compensating amplifier isreplaced with a switching counterpart, it has been demonstrated that it is possible to expect a feasible improvement in energyconsumption in the middle of the ideal half-class D class and classical B class realisations.