Shovan Maity
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shovan Maity has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Shreyas Sen
Department of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, USA
22 shared publications - Baibhab Chatterjee
University of Florida
13 shared publications - Debayan Das
Department of Electrical Engineering, Indian Institute of Science, Bengaluru, India
9 shared publications - Mayukh Nath
Department of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, USA
6 shared publications Baibhab Chatterjee
Purdue University, School of Electrical and Computer Engineering, West Lafayette, IN, 47907, USA
3 shared publications- Priyadarshini Panda
Yale University Yale University Yale University Yale University
3 shared publications
Latest Publications
- 1 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A 65 nm 2.02 mW 50 Mbps Direct Analog to MJPEG Converter for Video Sensor Nodes using low-noise Switched Capacitor MAC-Quantizer with automatic calibration and Sparsity-aware ADC
Recent expansions in camera deployments for applications like surveillance, healthcare, autonomous vehicles, robots necessitate low-power realizations even with large data volume. Standard digital video cameras generate $\sim$ Gbps data that are usually compressed to 10’s of Mbps, often in the camera (e.g. Omnivision 5640) using compression schemes, like lossy MJPEG before high energy/bit wireless communication. For instance (Fig. 1), a $2 \mathrm{~K}$ RGB 8 b video at 30 fps will generate $\sim 1.5 \mathrm{Gbps}$ that is reduced to $\sim 75 \mathrm{Mbps}$ (MJPEG: per-frame compression) or to $\sim 6 \mathrm{Mbps}$ (H.264: both per-frame and inter-frame compression). While H.264 enables lower data rate, it suffers from complex decoding (incurs high latency), and poor error tolerance, thus MJPEG is preferred for latency-sensitive error-prone communication of compressed video with real-time inference needs. However, such in-camera ADC with Digital compression suffers from 1) high data volume (Gbps) generated, consuming high ADC energy; 2) high compute energy required by the in-sensor digital accelerator to compress the data, increasing the power consumption of the processing modules in these nodes to $\sim 10$ ’s mW. This work draws on the recent progress of mixed-signal in-sensor computing to address the above challenges in these high-power and high datavolume nodes and presents a “direct Analog to MJPEG Conversion (d-AJC)” technique that (1) compresses the analog pixel values from imagers in the mixed-signal domain using Switched Capacitor (SC)-based multiply and accumulate (MAC) units, and Quantizer, before (2) digitizing them with an event-driven sparsity aware ADC with run-length encoding, effectively compressing Gbps data in SC domain with 10’s of Mbps ADC, leading to an order of magnitude system power benefit. With gaining prominence of low-power analog camera sensors (e.g., 25mW Omnivision 6946), along with the development of low-cost processing schemes, d-AJC, it is envisioned to solve issue of high-power imager nodes.- 1 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A 65 nm 2.02 mW 50 Mbps Direct Analog to MJPEG Converter for Video Sensor Nodes using low-noise Switched Capacitor MAC-Quantizer with automatic calibration and Sparsity-aware ADC
Recent expansions in camera deployments for applications like surveillance, healthcare, autonomous vehicles, robots necessitate low-power realizations even with large data volume. Standard digital video cameras generate $\sim$ Gbps data that are usually compressed to 10’s of Mbps, often in the camera (e.g. Omnivision 5640) using compression schemes, like lossy MJPEG before high energy/bit wireless communication. For instance (Fig. 1), a $2 \mathrm{~K}$ RGB 8 b video at 30 fps will generate $\sim 1.5 \mathrm{Gbps}$ that is reduced to $\sim 75 \mathrm{Mbps}$ (MJPEG: per-frame compression) or to $\sim 6 \mathrm{Mbps}$ (H.264: both per-frame and inter-frame compression). While H.264 enables lower data rate, it suffers from complex decoding (incurs high latency), and poor error tolerance, thus MJPEG is preferred for latency-sensitive error-prone communication of compressed video with real-time inference needs. However, such in-camera ADC with Digital compression suffers from 1) high data volume (Gbps) generated, consuming high ADC energy; 2) high compute energy required by the in-sensor digital accelerator to compress the data, increasing the power consumption of the processing modules in these nodes to $\sim 10$ ’s mW. This work draws on the recent progress of mixed-signal in-sensor computing to address the above challenges in these high-power and high datavolume nodes and presents a “direct Analog to MJPEG Conversion (d-AJC)” technique that (1) compresses the analog pixel values from imagers in the mixed-signal domain using Switched Capacitor (SC)-based multiply and accumulate (MAC) units, and Quantizer, before (2) digitizing them with an event-driven sparsity aware ADC with run-length encoding, effectively compressing Gbps data in SC domain with 10’s of Mbps ADC, leading to an order of magnitude system power benefit. With gaining prominence of low-power analog camera sensors (e.g., 25mW Omnivision 6946), along with the development of low-cost processing schemes, d-AJC, it is envisioned to solve issue of high-power imager nodes.- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 32 (6) , 792-795
A Quantitative Analysis of Physical Security and Path Loss With Frequency for IBOB Channel
Security vulnerabilities demonstrated in implantable medical devices have opened the door for research into physically secure and low power communication methodologies. In this study, we perform a comparative analysis of commonly used ISM frequency bands and human body communication (HBC) for data transfer from in-body to out-of-body (IBOB). We develop a figure of merit (FoM) that comprises of the critical parameters to quantitatively compare the communication methodologies. We perform finite-element method (FEM)-based simulations and experiments to validate the FoM developed.
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 32 (6) , 792-795
A Quantitative Analysis of Physical Security and Path Loss With Frequency for IBOB Channel
Security vulnerabilities demonstrated in implantable medical devices have opened the door for research into physically secure and low power communication methodologies. In this study, we perform a comparative analysis of commonly used ISM frequency bands and human body communication (HBC) for data transfer from in-body to out-of-body (IBOB). We develop a figure of merit (FoM) that comprises of the critical parameters to quantitatively compare the communication methodologies. We perform finite-element method (FEM)-based simulations and experiments to validate the FoM developed.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (3) , 831-844
EQS Res-HBC: A 65-nm Electro-Quasistatic Resonant 5–240 μW Human Whole-Body Powering and 2.19 μW Communication SoC With Automatic Maximum Resonant Power Tracking
Applications like connected healthcare through physiological signal monitoring and secure authentication using wearable keys can benefit greatly from the battery-less operation. Low-power communication along with energy harvesting is critical to sustain such perpetual battery-less operation. Human body channel is known to be a promising alternative to wireless radio wave communication for low power operation through human body communication (HBC), as well as very recently demonstrated as a medium for power transfer through body-coupled power transfer. However, channel length (L) dependency of the received power makes it inefficient for L>40 cm. In this article, we utilize electro-quasistatic resonant HBC (EQS Res-HBC) with maximum resonant power tracking (MRPT) to enable channel length-independent whole-body communication and powering. We design the first system to transfer power and data from a HUB device to wearable energy-harvested NODE through the human body to enable battery-less perpetual operation. Measurement results show 240, 28, and 5$\mu \text{W}$ power transfer through the body in a machine–machine (large devices with strong ground connection), tabletop (small devices kept on a table), and wearable–wearable (small form factor battery-operated wearable devices) scenario, respectively, independent of body channel length, while enabling communication at 2.19$\mu \text{W}$ . This enables >25$\times $ more power transfer with >100$\times $ more efficiency compared to the state of the art for 100-cm body channel in tabletop scenario by utilizing the benefits of EQS operation. The MRPT loop automatically tracks device and posture-dependent changes in the resonance point to maximize power transfer in all cases.- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (3) , 831-844
EQS Res-HBC: A 65-nm Electro-Quasistatic Resonant 5–240 μW Human Whole-Body Powering and 2.19 μW Communication SoC With Automatic Maximum Resonant Power Tracking
Applications like connected healthcare through physiological signal monitoring and secure authentication using wearable keys can benefit greatly from the battery-less operation. Low-power communication along with energy harvesting is critical to sustain such perpetual battery-less operation. Human body channel is known to be a promising alternative to wireless radio wave communication for low power operation through human body communication (HBC), as well as very recently demonstrated as a medium for power transfer through body-coupled power transfer. However, channel length (L) dependency of the received power makes it inefficient for L>40 cm. In this article, we utilize electro-quasistatic resonant HBC (EQS Res-HBC) with maximum resonant power tracking (MRPT) to enable channel length-independent whole-body communication and powering. We design the first system to transfer power and data from a HUB device to wearable energy-harvested NODE through the human body to enable battery-less perpetual operation. Measurement results show 240, 28, and 5$\mu \text{W}$ power transfer through the body in a machine–machine (large devices with strong ground connection), tabletop (small devices kept on a table), and wearable–wearable (small form factor battery-operated wearable devices) scenario, respectively, independent of body channel length, while enabling communication at 2.19$\mu \text{W}$ . This enables >25$\times $ more power transfer with >100$\times $ more efficiency compared to the state of the art for 100-cm body channel in tabletop scenario by utilizing the benefits of EQS operation. The MRPT loop automatically tracks device and posture-dependent changes in the resonance point to maximize power transfer in all cases.- Open Access
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Circuits and Systems
- Vol. 2, 363-379
Theoretical Analysis of Multi Integrating RX Front-Ends for Lossy Broad-Band Channels
Recent advances in wire-like communication channels without a physical wire has seen the emergence of wireline-like broadband channels but with atypical high loss. Communication links using such channels (e.g., Proximity Communication, Human Body Communication) are typically broadband, like wireline systems but noise-limited like wireless systems. Hence, employing broad-band communication through such emerging channels calls for new research on analyzing, designing and finding the theoretical limits for receiver topologies suitable for lossy broad-band channels . In this paper, we present a theoretical analysis framework for various broadband receivers in combination with low-noise amplifiers and proposed multi-integrator cascade, which provides significant gain with relatively lower power consumption than the standard gain elements. Through 1) derivation of new noise analysis of integrating-sampling receivers, 2) proposal of a new circuit topology (multi-integrating receiver, MIR) and 3) development of a thorough design space exploration framework, including use of a combination of wireless-inspired Low-noise amplifiers (LNA) with wireline-inspired strong-ARM latches, and the newly proposed MIRs, this paper demonstrates the optimum design choices for some common scenarios. Maximum achievable data rate and optimum energy-efficiency for various channel losses have been obtained theoretically for different topologies revealing their advantages and limitations, intended to serve as a guide for future receiver designs for lossy broad-band channels . All the circuits have been designed in 65 nm CMOS process with a 1 V supply voltage.
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Circuits and Systems
- Vol. 2, 363-379
Open AccessTheoretical Analysis of Multi Integrating RX Front-Ends for Lossy Broad-Band Channels
Recent advances in wire-like communication channels without a physical wire has seen the emergence of wireline-like broadband channels but with atypical high loss. Communication links using such channels (e.g., Proximity Communication, Human Body Communication) are typically broadband, like wireline systems but noise-limited like wireless systems. Hence, employing broad-band communication through such emerging channels calls for new research on analyzing, designing and finding the theoretical limits for receiver topologies suitable for lossy broad-band channels . In this paper, we present a theoretical analysis framework for various broadband receivers in combination with low-noise amplifiers and proposed multi-integrator cascade, which provides significant gain with relatively lower power consumption than the standard gain elements. Through 1) derivation of new noise analysis of integrating-sampling receivers, 2) proposal of a new circuit topology (multi-integrating receiver, MIR) and 3) development of a thorough design space exploration framework, including use of a combination of wireless-inspired Low-noise amplifiers (LNA) with wireline-inspired strong-ARM latches, and the newly proposed MIRs, this paper demonstrates the optimum design choices for some common scenarios. Maximum achievable data rate and optimum energy-efficiency for various channel losses have been obtained theoretically for different topologies revealing their advantages and limitations, intended to serve as a guide for future receiver designs for lossy broad-band channels . All the circuits have been designed in 65 nm CMOS process with a 1 V supply voltage.
- 20 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (3) , 788-802
Sub-μWRComm: 415-nW 1–10-kb/s Physically and Mathematically Secure Electro-Quasi-Static HBC Node for Authentication and Medical Applications
Low-power secure communication is one of the key enablers of applications, such as secure authentication and remote health monitoring. Radio wave-based communication method, such as Bluetooth, suffers from high-power requirements and physical signal leakage. Electro-quasi-static human body communication (EQS-HBC) utilizes the conductivity of the human body to use it as a communication medium and confine the signal within a close proximity of the body and enable low power consumption through low-frequency operation. This makes EQS-HBC an attractive alternative for such low-power, low-data-rate secure communication. In this article, we present the first >1 kb/s Sub- μ W WeaRable Communication (Sub- μ WRComm), a secure EQS-HBC node, which uses EQS-HBC for physical security and an AES-256 engine for mathematical security and operate at sub-$\mu \text{W}$ power budget. The signal confinement property of EQS-HBC is demonstrated through finite element method (FEM) simulations and leakage measurements, establishing its security property. The Sub- μ WRComm system consumes only 415-nW total power, with 108-nW active power at the lowest power mode, operating at a data rate of 1 kb/s with -64-dBm sensitivity making it suitable for authentication and remote monitoring applications. This work presents a 100x improvement compared with state-of-the-art HBC implementations while providing simultaneous physical and mathematical security for the first time.
- 20 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (3) , 788-802
Sub-μWRComm: 415-nW 1–10-kb/s Physically and Mathematically Secure Electro-Quasi-Static HBC Node for Authentication and Medical Applications
Low-power secure communication is one of the key enablers of applications, such as secure authentication and remote health monitoring. Radio wave-based communication method, such as Bluetooth, suffers from high-power requirements and physical signal leakage. Electro-quasi-static human body communication (EQS-HBC) utilizes the conductivity of the human body to use it as a communication medium and confine the signal within a close proximity of the body and enable low power consumption through low-frequency operation. This makes EQS-HBC an attractive alternative for such low-power, low-data-rate secure communication. In this article, we present the first >1 kb/s Sub- μ W WeaRable Communication (Sub- μ WRComm), a secure EQS-HBC node, which uses EQS-HBC for physical security and an AES-256 engine for mathematical security and operate at sub-$\mu \text{W}$ power budget. The signal confinement property of EQS-HBC is demonstrated through finite element method (FEM) simulations and leakage measurements, establishing its security property. The Sub- μ WRComm system consumes only 415-nW total power, with 108-nW active power at the lowest power mode, operating at a data rate of 1 kb/s with -64-dBm sensitivity making it suitable for authentication and remote monitoring applications. This work presents a 100x improvement compared with state-of-the-art HBC implementations while providing simultaneous physical and mathematical security for the first time.
- 24 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (1) , 136-150
EM and Power SCA-Resilient AES-256 Through >350× Current-Domain Signature Attenuation and Local Lower Metal Routing
Mathematically secure cryptographic algorithms, when implemented on a physical substrate, leak critical “side-channel” information, leading to power and electromagnetic (EM) analysis attacks. Circuit-level protections involve switched capacitor, buck converter, or series low-dropout (LDO) regulator-based implementations, each of which suffers from significant power, area, or performance tradeoffs and has only achieved a minimum traces to disclosure (MTD) of $10M$ till date. Utilizing an in-depth white-box model, this work, for the first time, focuses on signature suppression in the current domain, which provides an $Attenuation^{2}$ enhancement in MTD, leading to orders of magnitude improvement in both power and EM side-channel analysis (SCA) immunities. Using a combination of current-domain “signature attenuation” (CDSA) along with local lower level metal routing, the critical correlated information in the crypto current is significantly suppressed before it reaches the supply pin. Especially, to prevent the EM leakage from its source (metal layers carrying the correlated crypto current acting as antennas), this work embraces lower level metal routing of the CDSA embedding the crypto-IP so that the signature becomes highly suppressed before it passes through the higher metal layers (which radiates significantly) to connect to the external pin. The 65-nm CMOS test chip contains both protected and unprotected parallel AES-256 implementations, running at a clock frequency of 50 MHz. Test vector leakage assessment (TVLA) on the protected CDSA-AES, demonstrated with on-chip measurements for the first time, shows that the higher level metal layers leak significantly more compared with the lower level metal routing. Correlational power and EM analysis (CPA/CEMA) attacks on the unprotected implementation were able to extract the secret key within $8k$ and $12k$ traces, respectively, while the protected CDSA-AES could not be broken even after $1B$ encryptions for both power and EM SCA, evaluated both in the time and frequency domains, showing an improvement of $100\times $ over the prior state-of-the-art countermeasures with comparable power and area overheads.
- 24 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (1) , 136-150
EM and Power SCA-Resilient AES-256 Through >350× Current-Domain Signature Attenuation and Local Lower Metal Routing
Mathematically secure cryptographic algorithms, when implemented on a physical substrate, leak critical “side-channel” information, leading to power and electromagnetic (EM) analysis attacks. Circuit-level protections involve switched capacitor, buck converter, or series low-dropout (LDO) regulator-based implementations, each of which suffers from significant power, area, or performance tradeoffs and has only achieved a minimum traces to disclosure (MTD) of $10M$ till date. Utilizing an in-depth white-box model, this work, for the first time, focuses on signature suppression in the current domain, which provides an $Attenuation^{2}$ enhancement in MTD, leading to orders of magnitude improvement in both power and EM side-channel analysis (SCA) immunities. Using a combination of current-domain “signature attenuation” (CDSA) along with local lower level metal routing, the critical correlated information in the crypto current is significantly suppressed before it reaches the supply pin. Especially, to prevent the EM leakage from its source (metal layers carrying the correlated crypto current acting as antennas), this work embraces lower level metal routing of the CDSA embedding the crypto-IP so that the signature becomes highly suppressed before it passes through the higher metal layers (which radiates significantly) to connect to the external pin. The 65-nm CMOS test chip contains both protected and unprotected parallel AES-256 implementations, running at a clock frequency of 50 MHz. Test vector leakage assessment (TVLA) on the protected CDSA-AES, demonstrated with on-chip measurements for the first time, shows that the higher level metal layers leak significantly more compared with the lower level metal routing. Correlational power and EM analysis (CPA/CEMA) attacks on the unprotected implementation were able to extract the secret key within $8k$ and $12k$ traces, respectively, while the protected CDSA-AES could not be broken even after $1B$ encryptions for both power and EM SCA, evaluated both in the time and frequency domains, showing an improvement of $100\times $ over the prior state-of-the-art countermeasures with comparable power and area overheads.
- 13 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (12) , 3392-3402
On the Safety of Human Body Communication
Human Body Communication (HBC) utilizes the electrical conductivity properties of the human body to communicate between devices in and around the body. The increased energy-efficiency and security provided by HBC compared to traditional radio wave based communication makes it a promising alternative to communicate between energy constrained wearable and implantable devices around the body.However, HBC requires electrical signals to be transmitted through the body, which makes it essential to have a thorough analysis of the safety aspects of such transmission. This paper looks into the compliance of the current density and electric/magnetic fields generated in different modalities of HBC with the established safety standards. Circuit and Finite Element Method (FEM) based simulations are carried out to quantitatively find the compliance of current density and fields with the established safety limits. The results show the currents and fields in capacitive HBC are orders of magnitude smaller than the specified limits. However, certain excitation modalties in galvanic HBC can result in current densities and fields exceeding the safety limits around the excitation point on the body near the electrode. A study with 7 human subjects (4 male, 3 female) is carried out over a month, using capacitive HBC.The study monitors the change in 5 vital parameters (Heart Rate, Mean Arterial Pressure, Respiration Rate, Peripheral Capillary Oxygen Saturation, Temperature), while wearing a HBC enabled device. Analysis of the acquired data statistically shows no significant change in any of the vital parameters of the subjects, confirming the results of the simulation study.
- 13 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (12) , 3392-3402
On the Safety of Human Body Communication
Human Body Communication (HBC) utilizes the electrical conductivity properties of the human body to communicate between devices in and around the body. The increased energy-efficiency and security provided by HBC compared to traditional radio wave based communication makes it a promising alternative to communicate between energy constrained wearable and implantable devices around the body.However, HBC requires electrical signals to be transmitted through the body, which makes it essential to have a thorough analysis of the safety aspects of such transmission. This paper looks into the compliance of the current density and electric/magnetic fields generated in different modalities of HBC with the established safety standards. Circuit and Finite Element Method (FEM) based simulations are carried out to quantitatively find the compliance of current density and fields with the established safety limits. The results show the currents and fields in capacitive HBC are orders of magnitude smaller than the specified limits. However, certain excitation modalties in galvanic HBC can result in current densities and fields exceeding the safety limits around the excitation point on the body near the electrode. A study with 7 human subjects (4 male, 3 female) is carried out over a month, using capacitive HBC.The study monitors the change in 5 vital parameters (Heart Rate, Mean Arterial Pressure, Respiration Rate, Peripheral Capillary Oxygen Saturation, Temperature), while wearing a HBC enabled device. Analysis of the acquired data statistically shows no significant change in any of the vital parameters of the subjects, confirming the results of the simulation study.
- Open Access
- 27 February 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1
Publisher Correction: Enabling Covert Body Area Network using Electro-Quasistatic Human Body Communication
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 27 February 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1
Open AccessPublisher Correction: Enabling Covert Body Area Network using Electro-Quasistatic Human Body Communication
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 4 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 55 (3) , 650-665
A Wearable Real-Time CMOS Dosimeter With Integrated Zero-Bias Floating Gate Sensor and an 861-nW 18-Bit Energy-Resolution Scalable Time-Based Radiation to Digital Converter
- 4 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 55 (3) , 650-665
A Wearable Real-Time CMOS Dosimeter With Integrated Zero-Bias Floating Gate Sensor and an 861-nW 18-Bit Energy-Resolution Scalable Time-Based Radiation to Digital Converter
- 14 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 67 (10) , 1879-1883
Toward Understanding the Return Path Capacitance in Capacitive Human Body Communication
- 14 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 67 (10) , 1879-1883
Toward Understanding the Return Path Capacitance in Capacitive Human Body Communication