Mayukh Nath
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mayukh Nath has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Shreyas Sen
Department of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, USA
18 shared publications - Baibhab Chatterjee
University of Florida
8 shared publications - Debayan Das
Department of Electrical Engineering, Indian Institute of Science, Bengaluru, India
8 shared publications - Shovan Maity
School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, USA
6 shared publications - Arunashish Datta
School of Electrical and Computer Engineering, Purdue University, West Lafayette, USA
5 shared publications Scott Weigand
Eli Lilly and Company, USA
5 shared publications
Latest Publications
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (5) , 1839-1851
Effect of Nearby Metals on Electro-Quasistatic Human Body Communication
In recent decades, Human Body Communication (HBC) has emerged as a promising alternative to traditional radio wave communication, utilizing the body's conductive properties for low-power connectivity among wearables. This method harnesses the human body as an energy-efficient channel for data transmission within the Electro-Quasistatic (EQS) frequency range, paving the way for advancements in Human-Machine Interaction (HMI). While previous research has noted the role of parasitic return paths in capacitive EQS-HBC, the influence of surrounding metallic objects on these paths-critical for EQS wireless signaling-has not been thoroughly investigated. This paper addresses this gap through a structured approach, analyzing how various conducting objects, ranging from non-grounded (floating) and grounded metals to enclosed metallic environments such as elevators and cars, affect the performance of the body-communication channel. We present a theoretical framework supported by Finite Element Method (FEM)-based simulations and experiments with wearable devices. Our findings reveal that metallic objects within $\sim$20 cm of the devices can reduce transmission loss by $\sim$10 dB. When the device's ground connects to a grounded metallic object, channel gain can increase by at least 20 dB. Additionally, the contact area during touch-based interactions with grounded metals depicts contact impedance-dependent high-pass channel characteristics. The proximity to metallic objects enhances variability within a critical distance, with grounded metals having an overall higher impact than floating ones. These insights are crucial for improving the reliability of body-centric communication links, thereby supporting applications in healthcare, consumer electronics, defense, and industrial sectors.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (5) , 1839-1851
Effect of Nearby Metals on Electro-Quasistatic Human Body Communication
In recent decades, Human Body Communication (HBC) has emerged as a promising alternative to traditional radio wave communication, utilizing the body's conductive properties for low-power connectivity among wearables. This method harnesses the human body as an energy-efficient channel for data transmission within the Electro-Quasistatic (EQS) frequency range, paving the way for advancements in Human-Machine Interaction (HMI). While previous research has noted the role of parasitic return paths in capacitive EQS-HBC, the influence of surrounding metallic objects on these paths-critical for EQS wireless signaling-has not been thoroughly investigated. This paper addresses this gap through a structured approach, analyzing how various conducting objects, ranging from non-grounded (floating) and grounded metals to enclosed metallic environments such as elevators and cars, affect the performance of the body-communication channel. We present a theoretical framework supported by Finite Element Method (FEM)-based simulations and experiments with wearable devices. Our findings reveal that metallic objects within $\sim$20 cm of the devices can reduce transmission loss by $\sim$10 dB. When the device's ground connects to a grounded metallic object, channel gain can increase by at least 20 dB. Additionally, the contact area during touch-based interactions with grounded metals depicts contact impedance-dependent high-pass channel characteristics. The proximity to metallic objects enhances variability within a critical distance, with grounded metals having an overall higher impact than floating ones. These insights are crucial for improving the reliability of body-centric communication links, thereby supporting applications in healthcare, consumer electronics, defense, and industrial sectors.
- 31 August 2023
- Published by Springer Nature in Nature Electronics
- Vol. 6 (9) , 703-716
Biphasic quasistatic brain communication for energy-efficient wireless neural implants
- 31 August 2023
- Published by Springer Nature in Nature Electronics
- Vol. 6 (9) , 703-716
Biphasic quasistatic brain communication for energy-efficient wireless neural implants
- Open Access
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Circuits and Systems
- Vol. 4, 271-282
PG-CAS: Pro-Active EM-SCA Probe Detection Using Switched-Capacitor-Based Patterned-Ground Co-Planar Capacitive Asymmetry Sensing
This paper presents the design and analysis of a pro-active strategy to detect the presence of an electromagnetic (EM) side-channel analysis (SCA) attack, using Patterned-Ground co-planar Capacitive Asymmetry Sensing (PG-CAS) system. The PG-CAS system senses the asymmetry created in the plate-ground capacitance and turns on a SCA countermeasure in presence of an EM probe. The proposed PG-CAS system for approaching probe consists of the EM SCA detection sensor plate and circuits. The EM SCA detection sensor is implemented as a grid of four metal plates of the same dimensions using the top metal layer along with a patterned-ground plane at the immediate lower metal layer. The EM SCA detection system consists of a proximity to capacitance conversion circuit, digital synchronization logic circuit to detect and alarm the IC, and an EM SCA countermeasure. When an attack is detected, the countermeasure is turned on based on the deviation of the symmetry of the plate-ground capacitance pairs. The PG-CAS system-level post-layout simulation results using TSMC 65nm technology and Ansys Maxwell show a >5× improvement in the detection range and a ~29× improvement in power consumption over existing inductive sensing methods for attack detection.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Circuits and Systems
- Vol. 4, 271-282
Open AccessPG-CAS: Pro-Active EM-SCA Probe Detection Using Switched-Capacitor-Based Patterned-Ground Co-Planar Capacitive Asymmetry Sensing
This paper presents the design and analysis of a pro-active strategy to detect the presence of an electromagnetic (EM) side-channel analysis (SCA) attack, using Patterned-Ground co-planar Capacitive Asymmetry Sensing (PG-CAS) system. The PG-CAS system senses the asymmetry created in the plate-ground capacitance and turns on a SCA countermeasure in presence of an EM probe. The proposed PG-CAS system for approaching probe consists of the EM SCA detection sensor plate and circuits. The EM SCA detection sensor is implemented as a grid of four metal plates of the same dimensions using the top metal layer along with a patterned-ground plane at the immediate lower metal layer. The EM SCA detection system consists of a proximity to capacitance conversion circuit, digital synchronization logic circuit to detect and alarm the IC, and an EM SCA countermeasure. When an attack is detected, the countermeasure is turned on based on the deviation of the symmetry of the plate-ground capacitance pairs. The PG-CAS system-level post-layout simulation results using TSMC 65nm technology and Ansys Maxwell show a >5× improvement in the detection range and a ~29× improvement in power consumption over existing inductive sensing methods for attack detection.
- 6 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
- Vol. 42 (12) , 4583-4596
Improved EM Side-Channel Analysis Attack Probe Detection Range Utilizing Coplanar Capacitive Asymmetry Sensing
While cryptographic implementations provide computational security in circuits and systems, hardware attack techniques e.g. Electromagnetic (EM) side-channel analysis (SCA) attack can still break through. The commonplace countermeasures for EM SCA attack require significant overheads in terms of power consumption. This paper explores an on-chip capacitive sensing technique for the purpose of detection of an approaching EM probe even before an attack is performed, thereby alleviating the overheads incurred by any countermeasure against such attacks. Different type of capacitive structures are considered in regards to sensitivity and area. The proposed method of Co-planar capacitivE Asymmetry SEnsing (CEASE) consists of a grid of four metal plates of the same size and dimensions determined through design space exploration. A comparison between capacitive and inductive sensing technique is also performed in terms of detection range through theoretical arguments and electromagnetic simulation. A >17% change in capacitance is shown at a distance of 1 mm, implying a >10× improvement in detection range over inductive sensing methods. Further, at 0.1 mm distance, a > 45% change in capacitance is observed, leading to a >3× and >11× sensitivity improvement over capacitive parallel plate sensing and inductive sensing respectively.
- 6 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
- Vol. 42 (12) , 4583-4596
Improved EM Side-Channel Analysis Attack Probe Detection Range Utilizing Coplanar Capacitive Asymmetry Sensing
While cryptographic implementations provide computational security in circuits and systems, hardware attack techniques e.g. Electromagnetic (EM) side-channel analysis (SCA) attack can still break through. The commonplace countermeasures for EM SCA attack require significant overheads in terms of power consumption. This paper explores an on-chip capacitive sensing technique for the purpose of detection of an approaching EM probe even before an attack is performed, thereby alleviating the overheads incurred by any countermeasure against such attacks. Different type of capacitive structures are considered in regards to sensitivity and area. The proposed method of Co-planar capacitivE Asymmetry SEnsing (CEASE) consists of a grid of four metal plates of the same size and dimensions determined through design space exploration. A comparison between capacitive and inductive sensing technique is also performed in terms of detection range through theoretical arguments and electromagnetic simulation. A >17% change in capacitance is shown at a distance of 1 mm, implying a >10× improvement in detection range over inductive sensing methods. Further, at 0.1 mm distance, a > 45% change in capacitance is observed, leading to a >3× and >11× sensitivity improvement over capacitive parallel plate sensing and inductive sensing respectively.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (4) , 1219-1230
Sub-GHz In-Body to Out-of-Body Communication Channel Modeling for Ruminant Animals for Smart Animal Agriculture
Sensors in and around the environment becoming ubiquitous has ushered in the age of smart animal agriculture which has the potential to greatly improve animal health and productivity. The data gathered from sensors dwelling in animal agriculture settings have made farms a part of the IoT space leading to active research in developing efficient communication methodologies for farm networks. This study focuses on the first hop of farm networks where data from inside the body of animals is communicated to a node dwelling outside the body. Novel experimental methods are used to calculate the channel loss at sub-GHz frequencies (100–900 MHz) to characterize the in-body to out-of-body (IBOB) communication channel in large animals. A first-of-its-kind 3D bovine modeling is done with computer vision techniques for detailed morphological features of the animal body to perform Finite Element Method based Electromagnetic simulations. The results of the simulations are experimentally validated to build a complete channel modeling methodology for IBOB animal-body-communication. The 3D bovine model is made available publicly on GitHub. The results illustrate that an IBOB communication channel is realizable from the rumen to the collar of ruminants with $\leq \text{90 dB}$ path loss at sub-GHz frequencies making communication feasible. The developed methodology has been illustrated for ruminants but can also be used for other IBOB studies. An efficient communication architecture can be formed using the channel modeling technique illustrated for IBOB communication in animals paving the way for the design and development of future smart animal agriculture systems.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (4) , 1219-1230
Sub-GHz In-Body to Out-of-Body Communication Channel Modeling for Ruminant Animals for Smart Animal Agriculture
Sensors in and around the environment becoming ubiquitous has ushered in the age of smart animal agriculture which has the potential to greatly improve animal health and productivity. The data gathered from sensors dwelling in animal agriculture settings have made farms a part of the IoT space leading to active research in developing efficient communication methodologies for farm networks. This study focuses on the first hop of farm networks where data from inside the body of animals is communicated to a node dwelling outside the body. Novel experimental methods are used to calculate the channel loss at sub-GHz frequencies (100–900 MHz) to characterize the in-body to out-of-body (IBOB) communication channel in large animals. A first-of-its-kind 3D bovine modeling is done with computer vision techniques for detailed morphological features of the animal body to perform Finite Element Method based Electromagnetic simulations. The results of the simulations are experimentally validated to build a complete channel modeling methodology for IBOB animal-body-communication. The 3D bovine model is made available publicly on GitHub. The results illustrate that an IBOB communication channel is realizable from the rumen to the collar of ruminants with $\leq \text{90 dB}$ path loss at sub-GHz frequencies making communication feasible. The developed methodology has been illustrated for ruminants but can also be used for other IBOB studies. An efficient communication architecture can be formed using the channel modeling technique illustrated for IBOB communication in animals paving the way for the design and development of future smart animal agriculture systems.
- 20 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (12) , 3717-3727
Bio-Physical Modeling of Galvanic Human Body Communication in Electro-Quasistatic Regime
Human Body Communication (HBC) is an alternative to radio wave-based Wireless Body Area Network (WBAN) because of its wide bandwidth leading to enhanced energy efficiency. Designing Modern HBC devices need the accurate electrical equivalent of the HBC channel for energy efficient communication. The objective of this paper is to present an improved lumped element-based detailed model of Galvanic HBC channel which can be used to explain the dependency of the channel behaviour on the internal body dependent parameters such as electrical properties of skin and muscle tissue layers along with the external parameters such as electrode size, electrode separation, geometrical position of the electrodes and return-path or parasitic capacitances. The model considers the frequency-dependent impedance of skin and muscle tissue layers and the effect of various coupling capacitances between the body and Tx/Rx electrodes to the Earth-Ground. A 2D planar structure of skin and muscle tissue layers is simulated using a Finite Element Method (FEM) tool to prove the validity of the proposed model. The effect of symmetry and asymmetry at the transmitter and receiver ends is also explained using the model. The model become very useful for fast calculation of Galvanic channel response without using any FEM tool. Experimental results show that the galvanic response is not only a function of channel length but also depends on the mismatch at the transmitter and receiver end. In case of a very high mismatch scenario, the channel behavior is dominated by the capacitive HBC, even for a galvanic excitation and termination.
- 20 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (12) , 3717-3727
Bio-Physical Modeling of Galvanic Human Body Communication in Electro-Quasistatic Regime
Human Body Communication (HBC) is an alternative to radio wave-based Wireless Body Area Network (WBAN) because of its wide bandwidth leading to enhanced energy efficiency. Designing Modern HBC devices need the accurate electrical equivalent of the HBC channel for energy efficient communication. The objective of this paper is to present an improved lumped element-based detailed model of Galvanic HBC channel which can be used to explain the dependency of the channel behaviour on the internal body dependent parameters such as electrical properties of skin and muscle tissue layers along with the external parameters such as electrode size, electrode separation, geometrical position of the electrodes and return-path or parasitic capacitances. The model considers the frequency-dependent impedance of skin and muscle tissue layers and the effect of various coupling capacitances between the body and Tx/Rx electrodes to the Earth-Ground. A 2D planar structure of skin and muscle tissue layers is simulated using a Finite Element Method (FEM) tool to prove the validity of the proposed model. The effect of symmetry and asymmetry at the transmitter and receiver ends is also explained using the model. The model become very useful for fast calculation of Galvanic channel response without using any FEM tool. Experimental results show that the galvanic response is not only a function of channel length but also depends on the mismatch at the transmitter and receiver end. In case of a very high mismatch scenario, the channel behavior is dominated by the capacitive HBC, even for a galvanic excitation and termination.
- 13 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (12) , 3635-3644
Understanding the Role of Magnetic and Magneto-Quasistatic Fields in Human Body Communication
With the advent of wearables, Human Body Communication (HBC) has emerged as a physically secure and power-efficient alternative to the otherwise ubiquitous Wireless Body Area Network (WBAN). Whereas the most investigated HBC modalities have been Electric and Electro-quasistatic (EQS) Capacitive and Galvanic, recently Magnetic HBC (M-HBC) has been proposed as a viable alternative. Previous works have investigated M-HBC through application points-of-view, without exploring its fundamental working principle. In this paper, a ground up analysis is performed to study the possible effects and contributions of the human body channel in M-HBC over 1kHz to 10 GHz, by electromagnetic simulations and supporting experiments. The results show that while M-HBC can be successfully operated as a body area network, the human body itself plays a minimal or negligible role in its functionality. For Magneto-quasistatic (MQS) HBC (frequencies less than ∼30 MHz), the body is transparent to the quasistatic magnetic field. Conversely for higher frequencies, the conductivity of human tissues attenuates Magnetic HBC fields due to induced Eddy currents, preventing the body to support efficient waveguide modes. With this conceptual understanding developed, different modes of operations of MQS HBC are outlined for both high impedance capacitive and 50Ω termination cases, and their performances are compared with EQS HBC for similar sized devices, over varying distances between TX and RX. The resulting report presents a fundamental understanding towards M-HBC operation and its contrast with EQS HBC, aiding HBC device designers to make educated design decisions, depending on application scenarios.
- 13 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (12) , 3635-3644
Understanding the Role of Magnetic and Magneto-Quasistatic Fields in Human Body Communication
With the advent of wearables, Human Body Communication (HBC) has emerged as a physically secure and power-efficient alternative to the otherwise ubiquitous Wireless Body Area Network (WBAN). Whereas the most investigated HBC modalities have been Electric and Electro-quasistatic (EQS) Capacitive and Galvanic, recently Magnetic HBC (M-HBC) has been proposed as a viable alternative. Previous works have investigated M-HBC through application points-of-view, without exploring its fundamental working principle. In this paper, a ground up analysis is performed to study the possible effects and contributions of the human body channel in M-HBC over 1kHz to 10 GHz, by electromagnetic simulations and supporting experiments. The results show that while M-HBC can be successfully operated as a body area network, the human body itself plays a minimal or negligible role in its functionality. For Magneto-quasistatic (MQS) HBC (frequencies less than ∼30 MHz), the body is transparent to the quasistatic magnetic field. Conversely for higher frequencies, the conductivity of human tissues attenuates Magnetic HBC fields due to induced Eddy currents, preventing the body to support efficient waveguide modes. With this conceptual understanding developed, different modes of operations of MQS HBC are outlined for both high impedance capacitive and 50Ω termination cases, and their performances are compared with EQS HBC for similar sized devices, over varying distances between TX and RX. The resulting report presents a fundamental understanding towards M-HBC operation and its contrast with EQS HBC, aiding HBC device designers to make educated design decisions, depending on application scenarios.
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 32 (6) , 792-795
A Quantitative Analysis of Physical Security and Path Loss With Frequency for IBOB Channel
Security vulnerabilities demonstrated in implantable medical devices have opened the door for research into physically secure and low power communication methodologies. In this study, we perform a comparative analysis of commonly used ISM frequency bands and human body communication (HBC) for data transfer from in-body to out-of-body (IBOB). We develop a figure of merit (FoM) that comprises of the critical parameters to quantitatively compare the communication methodologies. We perform finite-element method (FEM)-based simulations and experiments to validate the FoM developed.
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 32 (6) , 792-795
A Quantitative Analysis of Physical Security and Path Loss With Frequency for IBOB Channel
Security vulnerabilities demonstrated in implantable medical devices have opened the door for research into physically secure and low power communication methodologies. In this study, we perform a comparative analysis of commonly used ISM frequency bands and human body communication (HBC) for data transfer from in-body to out-of-body (IBOB). We develop a figure of merit (FoM) that comprises of the critical parameters to quantitatively compare the communication methodologies. We perform finite-element method (FEM)-based simulations and experiments to validate the FoM developed.
- 13 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 32 (6) , 784-787
Electromagnetic Analysis of Integrated On-Chip Sensing Loop for Side-Channel and Fault-Injection Attack Detection
Securing crypto-cores is becoming increasingly difficult with the advent of electro-magnetic (EM) side-channel analysis (EMSCA) and fault injection attacks (FIAs). This letter presents an Ansys high-frequency structure simulator (HFSS)-based simulation framework for EM analysis of an integrated on-chip sensor for detecting EMSCA and FIA and validates the efficacy of an on-chip higher metal layer loop-based zero area-overhead sensor using a custom-built 65-nm CMOS IC. A simple technique for incoming H-probe detection is also presented by measuring the absolute average of the induced voltage for every encryption.
- 13 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 32 (6) , 784-787
Electromagnetic Analysis of Integrated On-Chip Sensing Loop for Side-Channel and Fault-Injection Attack Detection
Securing crypto-cores is becoming increasingly difficult with the advent of electro-magnetic (EM) side-channel analysis (EMSCA) and fault injection attacks (FIAs). This letter presents an Ansys high-frequency structure simulator (HFSS)-based simulation framework for EM analysis of an integrated on-chip sensor for detecting EMSCA and FIA and validates the efficacy of an on-chip higher metal layer loop-based zero area-overhead sensor using a custom-built 65-nm CMOS IC. A simple technique for incoming H-probe detection is also presented by measuring the absolute average of the induced voltage for every encryption.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (3) , 831-844
EQS Res-HBC: A 65-nm Electro-Quasistatic Resonant 5–240 μW Human Whole-Body Powering and 2.19 μW Communication SoC With Automatic Maximum Resonant Power Tracking
Applications like connected healthcare through physiological signal monitoring and secure authentication using wearable keys can benefit greatly from the battery-less operation. Low-power communication along with energy harvesting is critical to sustain such perpetual battery-less operation. Human body channel is known to be a promising alternative to wireless radio wave communication for low power operation through human body communication (HBC), as well as very recently demonstrated as a medium for power transfer through body-coupled power transfer. However, channel length (L) dependency of the received power makes it inefficient for L>40 cm. In this article, we utilize electro-quasistatic resonant HBC (EQS Res-HBC) with maximum resonant power tracking (MRPT) to enable channel length-independent whole-body communication and powering. We design the first system to transfer power and data from a HUB device to wearable energy-harvested NODE through the human body to enable battery-less perpetual operation. Measurement results show 240, 28, and 5$\mu \text{W}$ power transfer through the body in a machine–machine (large devices with strong ground connection), tabletop (small devices kept on a table), and wearable–wearable (small form factor battery-operated wearable devices) scenario, respectively, independent of body channel length, while enabling communication at 2.19$\mu \text{W}$ . This enables >25$\times $ more power transfer with >100$\times $ more efficiency compared to the state of the art for 100-cm body channel in tabletop scenario by utilizing the benefits of EQS operation. The MRPT loop automatically tracks device and posture-dependent changes in the resonance point to maximize power transfer in all cases.- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (3) , 831-844
EQS Res-HBC: A 65-nm Electro-Quasistatic Resonant 5–240 μW Human Whole-Body Powering and 2.19 μW Communication SoC With Automatic Maximum Resonant Power Tracking
Applications like connected healthcare through physiological signal monitoring and secure authentication using wearable keys can benefit greatly from the battery-less operation. Low-power communication along with energy harvesting is critical to sustain such perpetual battery-less operation. Human body channel is known to be a promising alternative to wireless radio wave communication for low power operation through human body communication (HBC), as well as very recently demonstrated as a medium for power transfer through body-coupled power transfer. However, channel length (L) dependency of the received power makes it inefficient for L>40 cm. In this article, we utilize electro-quasistatic resonant HBC (EQS Res-HBC) with maximum resonant power tracking (MRPT) to enable channel length-independent whole-body communication and powering. We design the first system to transfer power and data from a HUB device to wearable energy-harvested NODE through the human body to enable battery-less perpetual operation. Measurement results show 240, 28, and 5$\mu \text{W}$ power transfer through the body in a machine–machine (large devices with strong ground connection), tabletop (small devices kept on a table), and wearable–wearable (small form factor battery-operated wearable devices) scenario, respectively, independent of body channel length, while enabling communication at 2.19$\mu \text{W}$ . This enables >25$\times $ more power transfer with >100$\times $ more efficiency compared to the state of the art for 100-cm body channel in tabletop scenario by utilizing the benefits of EQS operation. The MRPT loop automatically tracks device and posture-dependent changes in the resonance point to maximize power transfer in all cases.