Alain Reineix
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alain Reineix has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Christophe Guiffaut
XLIM, Centre National de la Recherche Scientifique, Limoges, France
14 shared publications - Guillaume Andrieu
XLIM Laboratory, UMR 7252, University of Limoges, Limoges, France
6 shared publications - Paul Monferran
University Gustave Eiffel
5 shared publications - Fabian Fustin
Dassault Aviation Company, 92552, Saint-Cloud, France
3 shared publications Fabrice Tristant
Dassault Aviation Company, France
3 shared publications- Fabrice Tristant
Dassault Aviation Company, 92552, Saint-Cloud, France
3 shared publications
Latest Publications
- 25 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 71 (9) , 7438-7446
Angle-Dependent Face-Centered SIBC Model of Metamaterial in Conformal FDTD Methods
To control the diffraction of a target illuminated by a radar wave, one technique is to consider periodics metamaterials. When they are applied as very thin heterogeneous layers on the surface of the target, the simulation by a full wave method based on meshed model has to deal with a multiscale problem, resulting in a huge amount of unknowns. This paper proposes to apply the metamaterial as an equivalent boundary condition via the Leontovich formula. The frequency-angle-polarization-dependent model is integrated on the surface target with a conformal FDTD resolution method. To establish the surface impedance model, a pattern of the metamaterial is modelled with periodic boundary conditions. The Spectral FDTD scheme is retained because existing numerical models developed for the FDTD method can be easily adapted to this method. Then, the CFL condition of the Spectral FDTD method is not restrictive and is the one given by the standard Yee scheme. The accuracy of the new scheme is first compared with the full material FDTD meshing and the Cartesian SIBC model when the target is a plate or a cube. Finally, the computational efficiency of the proposed SIBC model is evaluated on a cylinder with comparisons between FEKO, CST software and our homemade solver.
- 25 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 71 (9) , 7438-7446
Angle-Dependent Face-Centered SIBC Model of Metamaterial in Conformal FDTD Methods
To control the diffraction of a target illuminated by a radar wave, one technique is to consider periodics metamaterials. When they are applied as very thin heterogeneous layers on the surface of the target, the simulation by a full wave method based on meshed model has to deal with a multiscale problem, resulting in a huge amount of unknowns. This paper proposes to apply the metamaterial as an equivalent boundary condition via the Leontovich formula. The frequency-angle-polarization-dependent model is integrated on the surface target with a conformal FDTD resolution method. To establish the surface impedance model, a pattern of the metamaterial is modelled with periodic boundary conditions. The Spectral FDTD scheme is retained because existing numerical models developed for the FDTD method can be easily adapted to this method. Then, the CFL condition of the Spectral FDTD method is not restrictive and is the one given by the standard Yee scheme. The accuracy of the new scheme is first compared with the full material FDTD meshing and the Cartesian SIBC model when the target is a plate or a cube. Finally, the computational efficiency of the proposed SIBC model is evaluated on a cylinder with comparisons between FEKO, CST software and our homemade solver.
- 26 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (3) , 812-822
Prediction of Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank With Machine Learning Methods
An important challenge for the aircraft industry consists to predict the currents on the fastening assemblies in order to avoid sparking, which can lead to accident, especially for fuel tank fasteners. In the literature, it has been demonstrated that the contact resistance plays a major role in the current path on fasteners. Nevertheless, these contact resistances cannot be well determined and vary greatly. As a result, the prediction of current must be done in a statistical way. Usually, it requires several aircraft simulations with several set of contact resistances, which represents a significant computational cost. This article proposes a machine learning model, which allows us to predict the currents in the fastening assemblies of an aircraft fuel tank in a few seconds. This model is built from a database of FDTD simulations of the aircraft fuel tank in the lightning frequency range 100 Hz to 1 MHz. The FDTD modeling is depicted in detail in this article based on previous work. From this database, several machine leaning approaches are explored ( $k$ -nearest neighbors, support vector regression, XGBoost, and a neural network). As a result of this study, XGBoost presents the best performances. Further investigations using XGBoost highlights the ability of the model to predict well the current for most fasteners and frequencies, even with a small amount of simulations as training data. Moreover, the proposed model allows us to perform a parametric analysis, which underline the ability of the model to provide results in agreement with the physical effects of the issue (current paths, resistive effects, inductive effects, etc.). The results presented are promising for the use of the proposed methodology in the aeronautical industry.
- 26 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (3) , 812-822
Prediction of Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank With Machine Learning Methods
An important challenge for the aircraft industry consists to predict the currents on the fastening assemblies in order to avoid sparking, which can lead to accident, especially for fuel tank fasteners. In the literature, it has been demonstrated that the contact resistance plays a major role in the current path on fasteners. Nevertheless, these contact resistances cannot be well determined and vary greatly. As a result, the prediction of current must be done in a statistical way. Usually, it requires several aircraft simulations with several set of contact resistances, which represents a significant computational cost. This article proposes a machine learning model, which allows us to predict the currents in the fastening assemblies of an aircraft fuel tank in a few seconds. This model is built from a database of FDTD simulations of the aircraft fuel tank in the lightning frequency range 100 Hz to 1 MHz. The FDTD modeling is depicted in detail in this article based on previous work. From this database, several machine leaning approaches are explored ( $k$ -nearest neighbors, support vector regression, XGBoost, and a neural network). As a result of this study, XGBoost presents the best performances. Further investigations using XGBoost highlights the ability of the model to predict well the current for most fasteners and frequencies, even with a small amount of simulations as training data. Moreover, the proposed model allows us to perform a parametric analysis, which underline the ability of the model to provide results in agreement with the physical effects of the issue (current paths, resistive effects, inductive effects, etc.). The results presented are promising for the use of the proposed methodology in the aeronautical industry.
- 11 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (1) , 28-38
Virtual Signal Integrity Test on Shielded/Unshielded Twisted-Wire Pairs in Reverberation Chambers Under Realistic Industrial Constraints
A recent method able to perform “virtual” signal integrity test on twisted-wire pairs (shielded or not) using a bulk current injection setup is, in a first part, extended successfully to the case of reverberation chamber tests in order to deal with a higher frequency range. The method, allowing in postprocessing to superimpose the effect of the measured disturbance (calculated from S -parameter measurements) to a useful signal generated numerically, is proven to be independent of the measurement conditions (position of the antenna, reverberation chambers quality factor, for instance) and is able to easily consider the electromagnetic field uncertainty occurring in such facility. In a second part, the method is improved through the use of full-wave numerical simulations in order to deal with realistic industrial constraints. The method can therefore be applied on twisted wire pairs of any length and connected to frequency-dependent termination loads of any values. The method allows to predict accurately (up to 2 GHz in this article) the signal integrity of any communication protocol and could help industrials to decide if a shielded version is necessary or not. An example of bit-error-rate prediction is finally done on a 100BASE-T1 fast Ethernet protocol signal on two shielded/unshielded twisted wire pairs.
- 11 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (1) , 28-38
Virtual Signal Integrity Test on Shielded/Unshielded Twisted-Wire Pairs in Reverberation Chambers Under Realistic Industrial Constraints
A recent method able to perform “virtual” signal integrity test on twisted-wire pairs (shielded or not) using a bulk current injection setup is, in a first part, extended successfully to the case of reverberation chamber tests in order to deal with a higher frequency range. The method, allowing in postprocessing to superimpose the effect of the measured disturbance (calculated from S -parameter measurements) to a useful signal generated numerically, is proven to be independent of the measurement conditions (position of the antenna, reverberation chambers quality factor, for instance) and is able to easily consider the electromagnetic field uncertainty occurring in such facility. In a second part, the method is improved through the use of full-wave numerical simulations in order to deal with realistic industrial constraints. The method can therefore be applied on twisted wire pairs of any length and connected to frequency-dependent termination loads of any values. The method allows to predict accurately (up to 2 GHz in this article) the signal integrity of any communication protocol and could help industrials to decide if a shielded version is necessary or not. An example of bit-error-rate prediction is finally done on a 100BASE-T1 fast Ethernet protocol signal on two shielded/unshielded twisted wire pairs.
- 18 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 21 (5) , 933-937
Wideband Simulations of Periodic Structures by the Hybrid Spectral FDTD/TD-VFz Method
The spectral finite-difference time-domain method is combined with the discrete-time time-domain vector fitting (TD-VFz) algorithm to analyze three-dimensional (3-D) periodic structures excited by oblique incident plane waves over a wide frequency band. The time signal reconstruction with TD-VFz produces an untruncated response over an infinite time window allowing an accurate spectral result, especially near the cutoff frequency separating the spectrum propagating wave region of the evanescent wave region.
- 18 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 21 (5) , 933-937
Wideband Simulations of Periodic Structures by the Hybrid Spectral FDTD/TD-VFz Method
The spectral finite-difference time-domain method is combined with the discrete-time time-domain vector fitting (TD-VFz) algorithm to analyze three-dimensional (3-D) periodic structures excited by oblique incident plane waves over a wide frequency band. The time signal reconstruction with TD-VFz produces an untruncated response over an infinite time window allowing an accurate spectral result, especially near the cutoff frequency separating the spectrum propagating wave region of the evanescent wave region.
- 27 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (5) , 1357-1365
“Virtual” Signal Integrity Test on Shielded/Unshielded Twisted-Wire Pairs Using the Bulk Current Injection Setup
In this article, a method able to perform “virtual” signal integrity test on twisted-wire pairs (shielded or not) is presented. The method is based on $S$ -parameter measurements collected in the case of a bulk current injection test setup. A common-to-differential-mode conversion is applied in postprocessing on these measurements in order to superimpose the effect of the measured disturbance to the useful signal, which is generated numerically. Then, the signal integrity of the cable under test can be verified as a function of the magnitude of the disturbance, the common-to-differential-mode conversion rate, and the useful signal waveform in reason of the linearity of the problem. The method, which allows a comparison between different kind of cables to be performed on a rigorous basis, is illustrated from experimental measurements made in the frequency range from 10 to 400 MHz in the case first of a square signal and second of a 100BASE-T1 fast Ethernet protocol signal.
- 27 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (5) , 1357-1365
“Virtual” Signal Integrity Test on Shielded/Unshielded Twisted-Wire Pairs Using the Bulk Current Injection Setup
In this article, a method able to perform “virtual” signal integrity test on twisted-wire pairs (shielded or not) is presented. The method is based on $S$ -parameter measurements collected in the case of a bulk current injection test setup. A common-to-differential-mode conversion is applied in postprocessing on these measurements in order to superimpose the effect of the measured disturbance to the useful signal, which is generated numerically. Then, the signal integrity of the cable under test can be verified as a function of the magnitude of the disturbance, the common-to-differential-mode conversion rate, and the useful signal waveform in reason of the linearity of the problem. The method, which allows a comparison between different kind of cables to be performed on a rigorous basis, is illustrated from experimental measurements made in the frequency range from 10 to 400 MHz in the case first of a square signal and second of a 100BASE-T1 fast Ethernet protocol signal.
- 3 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (2) , 558-570
Lightning-Induced Magnetic Fields Inside Grid-Like Shields: An Improved Formula Complemented by a Polynomial Chaos Expansion
In industrial facilities, evaluating the magnetic fields induced inside reinforced concrete buildings struck by lightning is fundamental to define protection measures. Since carrying out full-wave simulations is not always feasible nor practical daily, we propose a variant of the formula given in the standard IEC 62305-4 to calculate the peak values of the magnetic field strength inside grid-like shields formed by the reinforcing steel bars of the buildings. The formula is complemented by a sparse polynomial chaos expansion (PCE) to take into account various geometrical configurations of the grid-like shields. The PCE can be used independently to extrapolate the peak values from the results of either the formula or another computational method. The error of the formula and the PCE are estimated based on the simulation of the reinforcement of ten full-scale buildings for the first, and using alternative PCEs and Monte Carlo sampling for the second.
- 3 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (2) , 558-570
Lightning-Induced Magnetic Fields Inside Grid-Like Shields: An Improved Formula Complemented by a Polynomial Chaos Expansion
In industrial facilities, evaluating the magnetic fields induced inside reinforced concrete buildings struck by lightning is fundamental to define protection measures. Since carrying out full-wave simulations is not always feasible nor practical daily, we propose a variant of the formula given in the standard IEC 62305-4 to calculate the peak values of the magnetic field strength inside grid-like shields formed by the reinforcing steel bars of the buildings. The formula is complemented by a sparse polynomial chaos expansion (PCE) to take into account various geometrical configurations of the grid-like shields. The PCE can be used independently to extrapolate the peak values from the results of either the formula or another computational method. The error of the formula and the PCE are estimated based on the simulation of the reinforcement of ten full-scale buildings for the first, and using alternative PCEs and Monte Carlo sampling for the second.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (3) , 807-817
Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank, Part I: Uncertainties Assessment With Statistical Approach
This paper proposes a statistical approach in order to assess the fastening resistances uncertainties in aircraft assemblies. This method relies on the use of the maximum likelihood estimation method, several statistical tests, and/or statistical criteria. Using the Dassault-Aviation measurement database, distribution laws are established in order to characterize uncertainties in the lightning impact on the fasteners. A simple finite-difference time-domain (FDTD) fastener model is proposed with a wire and a resistance. This generic model can represent any fasteners. The statistical model established from the fastener resistances state after a lightning shot is used to define the stochastic distribution values in the fastener electric model. This model is added to a 3-D FDTD parallelepiped generic fuel tank model. In this paper, we compare the current distributions between a composite and metallic fuel tank. The results highlight not only the model uncertainties effects on the statistical approach but also the fuel tank material choice impact.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (3) , 807-817
Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank, Part I: Uncertainties Assessment With Statistical Approach
This paper proposes a statistical approach in order to assess the fastening resistances uncertainties in aircraft assemblies. This method relies on the use of the maximum likelihood estimation method, several statistical tests, and/or statistical criteria. Using the Dassault-Aviation measurement database, distribution laws are established in order to characterize uncertainties in the lightning impact on the fasteners. A simple finite-difference time-domain (FDTD) fastener model is proposed with a wire and a resistance. This generic model can represent any fasteners. The statistical model established from the fastener resistances state after a lightning shot is used to define the stochastic distribution values in the fastener electric model. This model is added to a 3-D FDTD parallelepiped generic fuel tank model. In this paper, we compare the current distributions between a composite and metallic fuel tank. The results highlight not only the model uncertainties effects on the statistical approach but also the fuel tank material choice impact.
- 24 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (5) , 2174-2185
Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank—Part III: Validation of the Current Assessment Method With Measurement
This article proposes a new fastener model and validate the stochastic process for the lightning current assessment in the aircraft assemblies proposed in the previous parts. In particular, the stochastic method concerns the finite-difference time domain (FDTD) fastener modeling for which the variability of the contact resistance has to be taken into account. The principle is to merge an electromagnetic fastener model with an uncertainty model. The new fastener model proposed in this article is a wire with a lumped resistor on a low conductive plate. This model is an improvement of the model of Part I, where the fastener is only represented by a wire with a lumped resistor. The proposed model in this article is able to ensure a good shielding effectiveness without current distribution disruptions provided that the conductivity of the plate is weak in contrast to the lumped resistor. Moreover, it has the benefits to be able to represent any fastener without location constraint in the FDTD grid. A log-normal distribution has been previously established as uncertainty model that represents the variability of the resistive parameter. The fastener model is included in the FDTD modeling of a realistic fuel tank with each lumped resistor taking a probabilistic value according to the log-normal law. To take into account, the variability of resistors, several simulations with different sets of resistance values are performed. The aim is to surround current measurements with simulated currents at various locations of the fuel tank for a lightning injection performed directly on a fuel tank fastener. This article demonstrates that a specific attention must be given to the modeling of fasteners close to the lightning injection point for the current assessment. Moreover, the results highlight the relevance of the use of an uncertainty model and its reliability for the lightning current assessment.
- 24 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (5) , 2174-2185
Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank—Part III: Validation of the Current Assessment Method With Measurement
This article proposes a new fastener model and validate the stochastic process for the lightning current assessment in the aircraft assemblies proposed in the previous parts. In particular, the stochastic method concerns the finite-difference time domain (FDTD) fastener modeling for which the variability of the contact resistance has to be taken into account. The principle is to merge an electromagnetic fastener model with an uncertainty model. The new fastener model proposed in this article is a wire with a lumped resistor on a low conductive plate. This model is an improvement of the model of Part I, where the fastener is only represented by a wire with a lumped resistor. The proposed model in this article is able to ensure a good shielding effectiveness without current distribution disruptions provided that the conductivity of the plate is weak in contrast to the lumped resistor. Moreover, it has the benefits to be able to represent any fastener without location constraint in the FDTD grid. A log-normal distribution has been previously established as uncertainty model that represents the variability of the resistive parameter. The fastener model is included in the FDTD modeling of a realistic fuel tank with each lumped resistor taking a probabilistic value according to the log-normal law. To take into account, the variability of resistors, several simulations with different sets of resistance values are performed. The aim is to surround current measurements with simulated currents at various locations of the fuel tank for a lightning injection performed directly on a fuel tank fastener. This article demonstrates that a specific attention must be given to the modeling of fasteners close to the lightning injection point for the current assessment. Moreover, the results highlight the relevance of the use of an uncertainty model and its reliability for the lightning current assessment.
- Open Access
- 17 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 13 (19391404) , 403-413
Method for the Sea Clutter Characterization in HF Surface Wave Radars From the Fields Diffracted by the Sea Surface
A new method for the characterization of the sea clutter in high-frequency surface wave radars is presented. The method is applied for the bistatic and the monostatic case. This method is based on the discretization of the sea surface in multiple patches. The fields diffracted by each patch are determined. Subsequently, the voltage that the diffracted fields induce on the receiving antenna is calculated. The sum of the voltages induced by all the patches is the sea clutter to be characterized. The fields diffracted by the sea patches are characterized in the form of field charts on a Huygens surface surrounding each patch. Field charts are modeled by analytical expressions. The current induced on the receiving antenna by the diffracted fields is calculated by means of the Lorentz reciprocity theorem. The feasibility of the method of characterization of the sea clutter is verified by means of the characterization of the fields diffracted by a single patch. The calculation of the induced current is done using the diffracted fields that are reconstructed from the analytical expressions that model them. It is also verified that the transmitting and receiving antenna can be replaced by plane wave sources, in order to simplify the calculations of the radiated fields that take part in the Lorentz reciprocity theorem. As a validation of the proposed method, the Doppler spectrum of a moving sea surface is calculated for the monostatic case.
- 17 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 13 (19391404) , 403-413
Open AccessMethod for the Sea Clutter Characterization in HF Surface Wave Radars From the Fields Diffracted by the Sea Surface
A new method for the characterization of the sea clutter in high-frequency surface wave radars is presented. The method is applied for the bistatic and the monostatic case. This method is based on the discretization of the sea surface in multiple patches. The fields diffracted by each patch are determined. Subsequently, the voltage that the diffracted fields induce on the receiving antenna is calculated. The sum of the voltages induced by all the patches is the sea clutter to be characterized. The fields diffracted by the sea patches are characterized in the form of field charts on a Huygens surface surrounding each patch. Field charts are modeled by analytical expressions. The current induced on the receiving antenna by the diffracted fields is calculated by means of the Lorentz reciprocity theorem. The feasibility of the method of characterization of the sea clutter is verified by means of the characterization of the fields diffracted by a single patch. The calculation of the induced current is done using the diffracted fields that are reconstructed from the analytical expressions that model them. It is also verified that the transmitting and receiving antenna can be replaced by plane wave sources, in order to simplify the calculations of the radiated fields that take part in the Lorentz reciprocity theorem. As a validation of the proposed method, the Doppler spectrum of a moving sea surface is calculated for the monostatic case.
- 15 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (3) , 818-828
Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank, Part II: FDTD Modeling Merged With a Circuit Model Supplemented by a Statistical Model
This paper presents a fastening assemblies FDTD model based on a lumped element circuit integrated into thin wire formalism. It can be used to quantify current dispersion or extreme current in aircraft fuel tank fasteners and to optimize the lightning protection in hotspot zones. An original method allows the characterization of the fastener lumped resistances. This method dealing with dc measurement and an optimization process is validated provided that 1) the measurements number is greater than the lumped elements number and 2) each node of the circuit is used at least once. Due to the large uncertainties from one fastener to the other one in the same family, the circuit model is supplement with a statistical model using the results about the fastener resistances state after a lightning shot presented in part I. Stochastic distribution values are applied to each lumped resistance of the fastener circuit model. Making a hybridization between a circuit solver and the finite difference time domain (FDTD) method, the circuit model is added in the same three-dimensional FDTD generic fuel tank modeling as presented in part I. Comparing the current distributions of the simple model of the part I and the circuit model, the uncertainties introduced by each model are presented.
- 15 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (3) , 818-828
Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank, Part II: FDTD Modeling Merged With a Circuit Model Supplemented by a Statistical Model
This paper presents a fastening assemblies FDTD model based on a lumped element circuit integrated into thin wire formalism. It can be used to quantify current dispersion or extreme current in aircraft fuel tank fasteners and to optimize the lightning protection in hotspot zones. An original method allows the characterization of the fastener lumped resistances. This method dealing with dc measurement and an optimization process is validated provided that 1) the measurements number is greater than the lumped elements number and 2) each node of the circuit is used at least once. Due to the large uncertainties from one fastener to the other one in the same family, the circuit model is supplement with a statistical model using the results about the fastener resistances state after a lightning shot presented in part I. Stochastic distribution values are applied to each lumped resistance of the fastener circuit model. Making a hybridization between a circuit solver and the finite difference time domain (FDTD) method, the circuit model is added in the same three-dimensional FDTD generic fuel tank modeling as presented in part I. Comparing the current distributions of the simple model of the part I and the circuit model, the uncertainties introduced by each model are presented.