FTFabrice Tristant

Fabrice Tristant

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fabrice Tristant has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank, Part I: Uncertainties Assessment With Statistical Approach

    by Paul Monferran, Christophe Guiffaut, Alain Reineix, Fabian Fustin, Fabrice Tristant

    This paper proposes a statistical approach in order to assess the fastening resistances uncertainties in aircraft assemblies. This method relies on the use of the maximum likelihood estimation method, several statistical tests, and/or statistical criteria. Using the Dassault-Aviation measurement database, distribution laws are established in order to characterize uncertainties in the lightning impact on the fasteners. A simple finite-difference time-domain (FDTD) fastener model is proposed with a wire and a resistance. This generic model can represent any fasteners. The statistical model established from the fastener resistances state after a lightning shot is used to define the stochastic distribution values in the fastener electric model. This model is added to a 3-D FDTD parallelepiped generic fuel tank model. In this paper, we compare the current distributions between a composite and metallic fuel tank. The results highlight not only the model uncertainties effects on the statistical approach but also the fuel tank material choice impact.


  • Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank—Part III: Validation of the Current Assessment Method With Measurement

    by Paul Monferran, Christophe Guiffaut, Alain Reineix, Fabian Fustin, Fabrice Tristant

    This article proposes a new fastener model and validate the stochastic process for the lightning current assessment in the aircraft assemblies proposed in the previous parts. In particular, the stochastic method concerns the finite-difference time domain (FDTD) fastener modeling for which the variability of the contact resistance has to be taken into account. The principle is to merge an electromagnetic fastener model with an uncertainty model. The new fastener model proposed in this article is a wire with a lumped resistor on a low conductive plate. This model is an improvement of the model of Part I, where the fastener is only represented by a wire with a lumped resistor. The proposed model in this article is able to ensure a good shielding effectiveness without current distribution disruptions provided that the conductivity of the plate is weak in contrast to the lumped resistor. Moreover, it has the benefits to be able to represent any fastener without location constraint in the FDTD grid. A log-normal distribution has been previously established as uncertainty model that represents the variability of the resistive parameter. The fastener model is included in the FDTD modeling of a realistic fuel tank with each lumped resistor taking a probabilistic value according to the log-normal law. To take into account, the variability of resistors, several simulations with different sets of resistance values are performed. The aim is to surround current measurements with simulated currents at various locations of the fuel tank for a lightning injection performed directly on a fuel tank fastener. This article demonstrates that a specific attention must be given to the modeling of fasteners close to the lightning injection point for the current assessment. Moreover, the results highlight the relevance of the use of an uncertainty model and its reliability for the lightning current assessment.


  • Lightning Currents on Fastening Assemblies of an Aircraft Fuel Tank, Part II: FDTD Modeling Merged With a Circuit Model Supplemented by a Statistical Model

    by Paul Monferran, Christophe Guiffaut, Alain Reineix, Fabian Fustin, Fabrice Tristant

    This paper presents a fastening assemblies FDTD model based on a lumped element circuit integrated into thin wire formalism. It can be used to quantify current dispersion or extreme current in aircraft fuel tank fasteners and to optimize the lightning protection in hotspot zones. An original method allows the characterization of the fastener lumped resistances. This method dealing with dc measurement and an optimization process is validated provided that 1) the measurements number is greater than the lumped elements number and 2) each node of the circuit is used at least once. Due to the large uncertainties from one fastener to the other one in the same family, the circuit model is supplement with a statistical model using the results about the fastener resistances state after a lightning shot presented in part I. Stochastic distribution values are applied to each lumped resistance of the fastener circuit model. Making a hybridization between a circuit solver and the finite difference time domain (FDTD) method, the circuit model is added in the same three-dimensional FDTD generic fuel tank modeling as presented in part I. Comparing the current distributions of the simple model of the part I and the circuit model, the uncertainties introduced by each model are presented.