JKJin-Gyu Kim

Jin-Gyu Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jin-Gyu Kim has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SEMOS: a scanning electron microscope optical simulator for instrumental performance optimization

    by Cheolsu Han, Yong-Eun Kwon, Jong-Man Jeung, Tae-Yeoung Lee, Jin-Gyu Kim

    In this study, a Scanning Electron Microscope Optical Simulator (SEMOS) was developed to provide an intuitive and quantitative understanding of electron-beam optics and to optimize lens operating parameters for improved SEM performance. The simulator integrates instrumental data–including electron source characteristics, lens geometries, and operating conditions—and performs electron-beam ray-tracing simulations to calculate key optical indicators such as probe size, probe current, and attainable resolution. The optical parameters of the condenser and objective lenses were derived using a commercial electron-optical design program, and SEMOS was subsequently applied to optimize the SPOT table, which stores predefined lens configurations in commercial SEMs. The optimized SPOT table improved the focusing consistency and resolution linearity across operational modes, demonstrating the practical applicability of SEMOS for both SEM users and developers. This work establishes a systematic simulation framework for electron-optical analysis and operational optimization in modern scanning electron microscopy.

  • Open Access

    Effective investigation of murine femoral bone development utilizing correlative light and electron microscopy (CLEM)

    by Yong-Eun Kwon, Jung-Kyun Kim, Youn-Joong Kim, A. Reum Je, Hwanuk Guim, Jin-Gyu Kim

    Background: For effective investigation of the developing structure and chemistry of bone, comprehensive studies including compositional analysis can be achieved through the gradual observation from the micro- to nanometer scale via correlative light and electron microscopy (CLEM). This technique is particularly useful considering the complex hierarchical arrangement of bioapatite and collagen fibrils which may vary according to specific bone tissue types (i.e., lamellar bone and woven bone) and different growth stages. Scanning electron microscopy (SEM) accompanied with the attachment of the scanning transmission electron microscopy (STEM) detector, referred to as the STEM-in-SEM can be utilized to produce high contrast images from materials composed of light elements, and efficiently allows the selection of suitable accelerating voltage for energy-dispersive spectroscopy (EDS). This study aims to emphasize the efficacy of CLEM techniques through applying STEM-in-SEM and EDS analyses, and its application to comparative murine bone investigation in differing ontogenetic stages. Findings: We have designed a new grid-holder which can be used for both light and electron microscopy, and we presented an imaging technique for TEM specimens via reflective light microscopy (RLM). For performing CLEM, ultra-thin-sections (UTS) prepared from the femoral bones of 1- to 16-week old of Sprague-Dawley (SD) rats provided light and electron micrographs that can be correlated based on the regions of interest (ROIs). STEM-in-SEM micrographs revealed information not attainable by secondary electron (SE) and back-scattered electron (BSE) micrographs. In addition, for analyzing chemical variation according to growth and development of femoral bones from 1- to 16-week-old rats, comparative chemical analysis was performed through STEM-in-SEM EDS with two reference materials. Conclusion: Herein, from femoral bones of SD rats, we have confirmed the rapid chemical and structural variations within the first 8 weeks after birth. STEM-in-SEM micrographs revealed the bone development process of the early stage porous bone matrix subsequently being filled with collagen fibrils and bioapatite. In addition, chemical analysis for carbon and oxygen showed the ratios of inorganic to organic phases according to growth and progress in bone mineralization. As a result, we were able to postulate the growth mechanism of murine femoral bone in the neonatal stages of development. We also anticipate that our CLEM techniques can be further utilized for more thorough investigation of bone structure and chemistry in diverse scales.


  • Open Access

    Abnormal shadow contrast imaging for optimal objective lens condition in transmission electron microscope

    by Yong-Eun Kwon, Cheolsu Han, Sang-Chul Lee, Jong-Man Jeung, Gaehang Lee, Tae-Yeoung Lee, Jin-Gyu Kim

    Background: In a transmission electron microscope (TEM), the objective lens (OL) is the most important component because the first image and diffraction pattern for a specimen are formed by applying a specific OL current and specimen height (SH). In TEM, the focal length of the OL should be controlled independently of the specimen position. Therefore, the initial conditions for OL should be determined by selecting the optimum imaging condition of the specimen based on the OL current and the specimen position. We would like to present a method for finding the optimal imaging condition for OL that can be applied to conventional or low-resolution TEM where high-resolution (HR) imaging is impossible. Findings: We conducted an abnormal contrast imaging experiment using Au nanoparticles (AuNPs). Abnormal contrast imaging was obtained by artificially controlling the mechanical alignment of OL P/Ps. Abnormal contrasts (shadow contrasts) of AuNPs were observed in all images obtained for various SH and OL currents. It was confirmed that these shadow contrasts of AuNPs result from the parasitic aberration caused by imperfect mechanical alignment of the OL P/Ps. From the quantitative analysis of the images, it was found that the effects of parasitic aberration in the TEM images decreased as SH approached the optimal position in the OL P/P. Conclusion: We examined the relationship of SH and OL current using the abnormal contrast imaging technique. The standard OL current and optimal SH were determined with OL condition minimizing the shadow contrast of images. The experimentally determined optimal SH at standard OL current in our specially designed OL system differed from that of the well-known asymmetry OL system. Therefore, it is essential to examine the optimum conditions from a practical perspective. Consequently, our abnormal contrast imaging method, which can be analyzed even in conventional imaging without HR-TEM performance, can help optimize the OL conditions during the manufacturing stage of the TEM instrument.


  • Open Access

    AA h BN crystal, basic structure of boron nitride nanotubes

    by Jae-Kap Lee, Jin-Gyu Kim, Seunggun Yu, Sang-Gil Lee, Yesong Kim, Dong Ju Moon

    AA h boron nitride (BN) crystal, assigned to an orthorhombic space group (No. 31, Pm21), is reported here. This new AA h BN crystal exhibits a `linear' morphology for high-resolution transmission electron microscopy (HRTEM) and a (non-hexagonal) `diagonal' electron-diffraction pattern, which have been experimentally demonstrated in this article. It is also demonstrated that this new crystal is the basic structure of multi-walled BN nanotubes (BNNTs) existing in the form of a helix. The helical AA h BNNTs exist in a metastable phase owing to 〈200〉 texture growth of the orthorhombic crystal, where the energy is ∼15 meV higher than that of stable AB or AA′ BN. It is shown that the typical scanning electron microscope `fluffy cotton-like' morphology of BNNTs is due to secondary growth of diverse BN sheets (including mono-layers) on incoherently scrolled wall strands of BNNTs, providing further evidence for the helical structure with HRTEM evidence for a left-handed helix.


  • Patient Posture Estimation Using Super-Resolution Reconstruction of Pressure Distribution Image for Pressure Ulcer Prevention

    by Jin-Gyu Kim, Myounghoon Shim, Eunkyung Bae, Youngjin Moon, Jaesoon Choi

    In this study, to improve the prediction of pressure ulcer spots, we have developed super-resolution (SR) techniques to reconstruct a high-resolution (HR) pressure image from a low-resolution (LR) body pressure image to overcome the limitations of sensor resolution. We implemented a super-resolution generative adversarial network (SRGAN) to reconstruct pressure images and a convolution neural network (CNN) to predict posture. To evaluate the similarity between the original pressure image and the 4× rescaled LR body pressure image restored using SR technology, we used image quality assessment (IQA) technology, peak signal-to-noise ratio (PSNR), and structural similarity (SSIM). The reconstructed pressure images were classified into four patient postures (supine, right side, left side, and others) with 98.37% accuracy showing the feasibility of practical implementation.

  • Open Access

    AB-stacked nanosheet-based hexagonal boron nitride

    by Jae-Kap Lee, Jin-Gyu Kim, K. P. S. S. Hembram, Seunggun Yu, Sang-Gil Lee

    Hexagonal boron nitride (h-BN) has been generally interpreted as having an AA stacking sequence. Evidence is presented in this article indicating that typical commercial h-BN platelets (∼10–500 nm in thickness) exhibit stacks of parallel nanosheets (∼10 nm in thickness) predominantly in the AB sequence. The AB-stacked nanosheet occurs as a metastable phase of h-BN resulting from the preferred texture and lateral growth of armchair (110) planes. It appears as an independent nanosheet or unit for h-BN platelets. The analysis is supported by simulation of thin AB films (2–20 layers), which explains the unique X-ray diffraction pattern of h-BN. With this analysis and the role of pressure in commercial high-pressure high-temperature sintering (driving nucleation and parallelizing the in-plane crystalline growth of the nuclei), a growth mechanism is proposed for 2D h-BN (on a substrate) as `substrate-induced 2D growth', where the substrate plays the role of pressure.


  • Open Access

    exCTF simulator: Simulation tool for phase contrast transfer function for aberration-corrected transmission electron microscopy

    by Sang-Chul Lee, Jong-Man Jeung, Jin-Gyu Kim

    Background: The contrast transfer function (CTF) is an important principle in the field of transmission electron microscopy (TEM) imaging. It provides information on how the electron wave that interacted with a sample (in frequency domain) in an objective lens is transferred to the imaging system (in real space domain) depending on the effects of lens aberrations. Based on the CTF calculation, various useful results, such as the TEM instrumental information limit and optimal imaging condition, can be estimated. Recently, aberration-corrected TEM (AC-TEM) has been widely applied in various research fields for imaging at the nanoscale or atomic scale. To use AC-TEM effectively, a deep understanding of the complicated CTF with an electron wave controlled via an aberration corrector is required. Unfortunately, this complicated CTF is difficult to understand for most microscopists without the use of computational tools. In this study, we develop the extended CTF (exCTF) simulator to perform the full as well as simple CTF calculation. Findings: We successfully developed the exCTF simulator, which can obtain more information than previously reported software. The exCTF simulator not only calculates the CTF for basic optical information that can be obtained in conventional TEM, but also can calculate the extended CTF with various aberrations (up to fifth order) for more detailed information obtained in advanced high-performance AC-TEM in one-dimensional and two-dimensional formats. The user interface of the simulator includes CTF calculation, saving, and edit functions for five graphs for different conditions, allowing for detailed comparative analysis. Conclusion: We confirmed that the exCTF simulator produced reliable calculation data for various applications. The exCTF simulator made it easy to obtain instrumental performance information and demonstrated the influence of optical aberrations on the actual resolution of AC-TEM. Consequently, the proposed exCTF simulator is expected to be useful to microscopists as a simulation tool for electron microscopy and as a training tool for electron optics.


  • Top Cited Papers

    Selective Hydrogenation of CO2 to Ethanol over Cobalt Catalysts

    by Lingxiang Wang, Liang Wang, Jian Zhang, Xiaolong Liu, Hai Wang, Wei Zhang, Qi Yang, Jingyuan Ma, Xue Dong, Seung Jo Yoo, et al.

    Methods for the hydrogenation of CO2 into valuable chemicals are in great demand but their development is still challenging. Herein, we report the selective hydrogenation of CO2 into ethanol over non‐noble cobalt catalysts (CoAlOx), presenting a significant advance for the conversion of CO2 into ethanol as the major product. By adjusting the composition of the catalysts through the use of different prereduction temperatures, the efficiency of CO2 to ethanol hydrogenation was optimized; the catalyst reduced at 600 ° gave an ethanol selectivity of 92.1 % at 140 °C with an ethanol time yield of 0.444 mmol g−1 h−1. Operando FT‐IR spectroscopy revealed that the high ethanol selectivity over the CoAlOx catalyst might be due to the formation of acetate from formate by insertion of *CHx, a key intermediate in the production of ethanol by CO2 hydrogenation.


  • Selective Hydrogenation of CO2 to Ethanol over Cobalt Catalysts

    by Lingxiang Wang, Liang Wang, Jian Zhang, Xiaolong Liu, Hai Wang, Wei Zhang, Qi Yang, Jingyuan Ma, Xue Dong, Seung Jo Yoo, et al.

    Methods for the hydrogenation of CO2 into valuable chemicals are in great demand but their development is still challenging. Herein, we report the selective hydrogenation of CO2 into ethanol over non‐noble cobalt catalysts (CoAlOx), presenting a significant advance for the conversion of CO2 into ethanol as the major product. By adjusting the composition of the catalysts through the use of different prereduction temperatures, the efficiency of CO2 to ethanol hydrogenation was optimized; the catalyst reduced at 600 ° gave an ethanol selectivity of 92.1 % at 140 °C with an ethanol time yield of 0.444 mmol g−1 h−1. Operando FT‐IR spectroscopy revealed that the high ethanol selectivity over the CoAlOx catalyst might be due to the formation of acetate from formate by insertion of *CHx, a key intermediate in the production of ethanol by CO2 hydrogenation.