Philippe Micheau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Philippe Micheau has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Nicolas Quaegebeur
Dept of Mechanical Engineering, CRASH-UdeS, Université de Sherbrooke, 2500 Boul de l'Université, Sherbrooke, J1K2R1, Québec, Canada
9 shared publications - Patrice Masson
GAUS, Department of Mechanical Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada
9 shared publications - Alain Berry
CRASH-UdeS, Department of Mechanical Engineering, Université de Sherbrooke 1 , Sherbrooke, Qc J1K2R1
7 shared publications - Hervé Walti
Department of Pediatrics, Université de Sherbrooke, J1H 5N4, QC, Canada; Hôpital d'enfant Armand Trousseau, Groupe Hospitalier Universitaire Est Parisien, Université Pierre et Marie Curie, Paris 6, Paris, France
3 shared publications Mathieu Renier
University of Bordeaux, Bordeaux INP, CNRS, Arts et Métiers Institute of Technology, INRAE, Bordeaux, France
3 shared publications- Matthias Kohlhauer
Inserm U955-IMRB, Equipe 03 "Pharmacologie et Technologies pour les Maladies Cardiovasculaires (PROTECT)", Ecole Nationale Vétérinaire d'Alfort (EnvA), Université Paris Est Créteil, Maisons-Alfort F-94700, France; Ecole Nationale Vétérinaire d'Alfort, Maisons-Alfort, France
3 shared publications
Latest Publications
- Open Access
- 27 August 2026
- Published by EDP Sciences in Acta Acustica
- Vol. 10
Active control of high-level tonal noise in flows up to Mach 0.5 using Harmonic Acoustic Pneumatic Sources
The Harmonic Acoustic Pneumatic Source (HAPS) has been designed to act as a secondary source for active control of fan noise in aircraft engines, taking advantage of the pneumatic energy from the turbofan. One challenge for its use in the nacelle is that the source has to produce a high-level tonal noise while being subjected to a significant grazing flow. The objective of this paper is to experimentally demonstrate active control of high-level multimodal tonal noise using HAPS installed on an aeroacoustic bench which reproduces the flow conditions encountered in a nacelle. A model of the acoustic radiation of the HAPS in a flow duct is also proposed, representing it as a point source with a specified acoustic mass flow rate. The experimental results indicate that HAPS can control the amplitude, phase and frequency of a high-level tonal anti-noise (120–145 dB), even with flow velocities up to a Mach number of 0.5. Attenuations between 9 dB and 30 dB are achieved for multimodal primary tonal noise between 400 Hz and 1160 Hz, with up to 3 propagating modes, showing the effectiveness of HAPS as secondary sources under these conditions.
- 27 August 2026
- Published by EDP Sciences in Acta Acustica
- Vol. 10
Open AccessActive control of high-level tonal noise in flows up to Mach 0.5 using Harmonic Acoustic Pneumatic Sources
The Harmonic Acoustic Pneumatic Source (HAPS) has been designed to act as a secondary source for active control of fan noise in aircraft engines, taking advantage of the pneumatic energy from the turbofan. One challenge for its use in the nacelle is that the source has to produce a high-level tonal noise while being subjected to a significant grazing flow. The objective of this paper is to experimentally demonstrate active control of high-level multimodal tonal noise using HAPS installed on an aeroacoustic bench which reproduces the flow conditions encountered in a nacelle. A model of the acoustic radiation of the HAPS in a flow duct is also proposed, representing it as a point source with a specified acoustic mass flow rate. The experimental results indicate that HAPS can control the amplitude, phase and frequency of a high-level tonal anti-noise (120–145 dB), even with flow velocities up to a Mach number of 0.5. Attenuations between 9 dB and 30 dB are achieved for multimodal primary tonal noise between 400 Hz and 1160 Hz, with up to 3 propagating modes, showing the effectiveness of HAPS as secondary sources under these conditions.
- 10 April 2026
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 252
Active Double Glazing With In-Cavity Compensated Microphones
- 10 April 2026
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 252
Active Double Glazing With In-Cavity Compensated Microphones
- 28 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Pressure Estimator of Airway Narrowing in Total Liquid Ventilation: First Results in Guinea Pigs
Total Liquid Ventilation (TLV) consists of ventilating the lungs of mammals with a breathable liquid (PFOB). This technology is being considered for extremely premature baby (less than 1 kg). However, liquid expiration in the high flexible airways can trigger a sudden tracheal collapse, observed as a sudden pressure drop at the endotracheal tube connector. To our knowledge, there is no reported TLV experiments in mammals of very low weight, ranged from 507 to 552 g (n=4), nor has tracheal collapse been observed. The objective is to develop a real-time pressure estimator to monitor the airway opening as well as to control the expiratory flow through a 2 mm diameter endotracheal tube. The experiments were carried out on 4 guinea pigs with a tracheotomy using a liquid ventilator during 4 hours. After 1 hour of TLV, acceptable blood gases were obtained proving that total liquid ventilation was tolerated. The experimental flow and pressure measurements from the first two experiments were used to learn the non-linear dynamics and the model parameters. The model was implemented in real-time on the microcontroller and used to test two control strategies of the expiratory flow. The last two guinea pigs were ventilated with the implemented estimator to detect sudden airway narrowing and to automatically control the expiratory flow rate. The results confirmed the effectiveness of the method in reversing the sudden pressure drop. In conclusion, the pressure estimator can be helpful in controlling liquid ventilation in mammals of very low weight, comparable to extreme premature babies.
- 28 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Pressure Estimator of Airway Narrowing in Total Liquid Ventilation: First Results in Guinea Pigs
Total Liquid Ventilation (TLV) consists of ventilating the lungs of mammals with a breathable liquid (PFOB). This technology is being considered for extremely premature baby (less than 1 kg). However, liquid expiration in the high flexible airways can trigger a sudden tracheal collapse, observed as a sudden pressure drop at the endotracheal tube connector. To our knowledge, there is no reported TLV experiments in mammals of very low weight, ranged from 507 to 552 g (n=4), nor has tracheal collapse been observed. The objective is to develop a real-time pressure estimator to monitor the airway opening as well as to control the expiratory flow through a 2 mm diameter endotracheal tube. The experiments were carried out on 4 guinea pigs with a tracheotomy using a liquid ventilator during 4 hours. After 1 hour of TLV, acceptable blood gases were obtained proving that total liquid ventilation was tolerated. The experimental flow and pressure measurements from the first two experiments were used to learn the non-linear dynamics and the model parameters. The model was implemented in real-time on the microcontroller and used to test two control strategies of the expiratory flow. The last two guinea pigs were ventilated with the implemented estimator to detect sudden airway narrowing and to automatically control the expiratory flow rate. The results confirmed the effectiveness of the method in reversing the sudden pressure drop. In conclusion, the pressure estimator can be helpful in controlling liquid ventilation in mammals of very low weight, comparable to extreme premature babies.
- Open Access
- 8 November 2024
- Published by Elsevier in Ultrasonics
- Vol. 146, 107494
Generation of broadband airborne ultrasound using an Harmonic Acoustic Pneumatic Source
- 8 November 2024
- Published by Elsevier in Ultrasonics
- Vol. 146, 107494
Open AccessGeneration of broadband airborne ultrasound using an Harmonic Acoustic Pneumatic Source
- Open Access
- 20 August 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (16) , e035617
Ultrafast Cooling With Total Liquid Ventilation Mitigates Early Inflammatory Response and Offers Neuroprotection in a Porcine Model of Cardiac Arrest
Background: Brain injury is one of the most serious complications after cardiac arrest (CA). To prevent this phenomenon, rapid cooling with total liquid ventilation (TLV) has been proposed in small animal models of CA (rabbits and piglets). Here, we aimed to determine whether hypothermic TLV can also offer neuroprotection and mitigate cerebral inflammatory response in large animals. Methods and Results: Anesthetized pigs were subjected to 14 minutes of ventricular fibrillation followed by cardiopulmonary resuscitation. After return of spontaneous circulation, animals were randomly subjected to normothermia (control group, n=8) or ultrafast cooling with TLV (TLV group, n=8). In the latter group, TLV was initiated within a window of 15 minutes after return of spontaneous circulation and allowed to reduce tympanic, esophageal, and bladder temperature to the 32 to 34 °C range within 30 minutes. After 45 minutes of TLV, gas ventilation was resumed, and hypothermia was maintained externally until 3 hours after CA, before rewarming using heat pads (0.5 °C–1 °C/h). After an additional period of progressive rewarming for 3 hours, animals were euthanized for brain withdrawal and histological analysis. At the end of the follow‐up (ie, 6 hours after CA), histology showed reduced brain injury as witnessed by the reduced number of Fluroro‐Jade C‐positive cerebral degenerating neurons in TLV versus control. IL (interleukin)‐1ra and IL‐8 levels were also significantly reduced in the cerebrospinal fluid in TLV versus control along with cerebral infiltration by CD3+ cells. Conversely, circulating levels of cytokines were not different among groups, suggesting a discrepancy between local and systemic inflammatory levels. Conclusions: Ultrafast cooling with TLV mitigates neuroinflammation and attenuates acute brain lesions in the early phase following resuscitation in large animals subjected to CA.
- 20 August 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (16) , e035617
Open AccessUltrafast Cooling With Total Liquid Ventilation Mitigates Early Inflammatory Response and Offers Neuroprotection in a Porcine Model of Cardiac Arrest
Background: Brain injury is one of the most serious complications after cardiac arrest (CA). To prevent this phenomenon, rapid cooling with total liquid ventilation (TLV) has been proposed in small animal models of CA (rabbits and piglets). Here, we aimed to determine whether hypothermic TLV can also offer neuroprotection and mitigate cerebral inflammatory response in large animals. Methods and Results: Anesthetized pigs were subjected to 14 minutes of ventricular fibrillation followed by cardiopulmonary resuscitation. After return of spontaneous circulation, animals were randomly subjected to normothermia (control group, n=8) or ultrafast cooling with TLV (TLV group, n=8). In the latter group, TLV was initiated within a window of 15 minutes after return of spontaneous circulation and allowed to reduce tympanic, esophageal, and bladder temperature to the 32 to 34 °C range within 30 minutes. After 45 minutes of TLV, gas ventilation was resumed, and hypothermia was maintained externally until 3 hours after CA, before rewarming using heat pads (0.5 °C–1 °C/h). After an additional period of progressive rewarming for 3 hours, animals were euthanized for brain withdrawal and histological analysis. At the end of the follow‐up (ie, 6 hours after CA), histology showed reduced brain injury as witnessed by the reduced number of Fluroro‐Jade C‐positive cerebral degenerating neurons in TLV versus control. IL (interleukin)‐1ra and IL‐8 levels were also significantly reduced in the cerebrospinal fluid in TLV versus control along with cerebral infiltration by CD3+ cells. Conversely, circulating levels of cytokines were not different among groups, suggesting a discrepancy between local and systemic inflammatory levels. Conclusions: Ultrafast cooling with TLV mitigates neuroinflammation and attenuates acute brain lesions in the early phase following resuscitation in large animals subjected to CA.
- Open Access
- 9 February 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 246, 108062
CT-FEM of the human thorax: Frequency response function and 3D harmonic analysis at resonance
- 9 February 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 246, 108062
Open AccessCT-FEM of the human thorax: Frequency response function and 3D harmonic analysis at resonance
- Open Access
- 1 January 2023
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 10 (1) , 24-35
Realistic 3D CT-FEM for Target-based Multiple Organ Inclusive Studies
Volume 10, Issue 1 published for JBEB Journal.
- 1 January 2023
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 10 (1) , 24-35
Open AccessRealistic 3D CT-FEM for Target-based Multiple Organ Inclusive Studies
Volume 10, Issue 1 published for JBEB Journal.
- 12 December 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (3) , 901-907
Influence of Plastination on Ultrasound Transmission Through the Human Skull
- 12 December 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (3) , 901-907
Influence of Plastination on Ultrasound Transmission Through the Human Skull
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 559-564
Preliminary results of a MIMO Harmonic Controller to perform active sound power attenuation with a RHAPSODI
A Harmonic Acoustic Pneumatic Source (HAPS) is an acoustic device developed to perform active harmonic sound control in turbofans. In order to develop a demonstrator, a ring of multiple HAPS (RHAPSODI) is assembled around a cylindrical duct and a dedicated MIMO harmonic controller was developed to perform active sound power attenuation. The control objective is to develop a MIMO feedback controller adapted to multiple HAPS and using in-duct microphones close to them. Three points are addressed : the control of HAPS as a mechanical modulator, the in-duct error microphones located in the near field of HAPS, and the tuning of the controller. The presented method is based on a dedicated MIMO feedback controller of complex envelops with compensation of near field. The compensation matrix of the near field is tuned during a learning phase based on the measurement of a set of optimal commands experimentally obtained with a dedicated controller using the out-duct microphones. When the matrix of compensation is estimated, the MIMO controller using induct microphones can be used. Preliminary experimental results show that a RHAPSODI of 5 HAPS can attenuate the first harmonic of a radiated tonal sound power by more than 20dB.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 559-564
Preliminary results of a MIMO Harmonic Controller to perform active sound power attenuation with a RHAPSODI
A Harmonic Acoustic Pneumatic Source (HAPS) is an acoustic device developed to perform active harmonic sound control in turbofans. In order to develop a demonstrator, a ring of multiple HAPS (RHAPSODI) is assembled around a cylindrical duct and a dedicated MIMO harmonic controller was developed to perform active sound power attenuation. The control objective is to develop a MIMO feedback controller adapted to multiple HAPS and using in-duct microphones close to them. Three points are addressed : the control of HAPS as a mechanical modulator, the in-duct error microphones located in the near field of HAPS, and the tuning of the controller. The presented method is based on a dedicated MIMO feedback controller of complex envelops with compensation of near field. The compensation matrix of the near field is tuned during a learning phase based on the measurement of a set of optimal commands experimentally obtained with a dedicated controller using the out-duct microphones. When the matrix of compensation is estimated, the MIMO controller using induct microphones can be used. Preliminary experimental results show that a RHAPSODI of 5 HAPS can attenuate the first harmonic of a radiated tonal sound power by more than 20dB.
- 1 August 2021
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 290, 103666
Air distribution within the lungs after total liquid ventilation in a neonatal ovine model
- 1 August 2021
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 290, 103666
Air distribution within the lungs after total liquid ventilation in a neonatal ovine model