Wei Loong Jong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wei Loong Jong has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Ngie Min Ung
Department of Clinical Oncology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
7 shared publications - Anatoly B. Rosenfeld
Centre for Medical Radiation Physics, University of Wollongong
6 shared publications - Jeannie Hsiu Ding Wong
Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
4 shared publications J.H.D. Wong
3 shared publicationsKwan Hoong Ng
Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia
3 shared publicationsAth Vannyat
Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia; Oncology Department, Calmette Hospital, Phnom Penh, Cambodia
2 shared publications
Latest Publications
- 1 November 2019
- Published by Elsevier in Physica Medica
- Vol. 67, 34-39
Medical physics aspects of Intensity-Modulated Radiotherapy practice in Malaysia
- 1 November 2019
- Published by Elsevier in Physica Medica
- Vol. 67, 34-39
Medical physics aspects of Intensity-Modulated Radiotherapy practice in Malaysia
- 1 February 2019
- Published by Elsevier in Physica Medica
- Vol. 58, 1-7
Characterization of MOSkin detector for in vivo dose verification during Cobalt-60 high dose-rate intracavitary brachytherapy
- 1 February 2019
- Published by Elsevier in Physica Medica
- Vol. 58, 1-7
Characterization of MOSkin detector for in vivo dose verification during Cobalt-60 high dose-rate intracavitary brachytherapy
- 13 May 2018
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 41 (2) , 475-485
Dosimetric characterisation of the optically-stimulated luminescence dosimeter in cobalt-60 high dose rate brachytherapy system
This study investigates the characteristics and application of the optically-stimulated luminescence dosimeter (OSLD) in cobalt-60 high dose rate (HDR) brachytherapy, and compares the results with the dosage produced by the treatment planning system (TPS). The OSLD characteristics comprised linearity, reproducibility, angular dependence, depth dependence, signal depletion, bleaching rate and cumulative dose measurement. A phantom verification exercise was also conducted using the Farmer ionisation chamber and in vivo diodes. The OSLD signal indicated a supralinear response (R2 = 0.9998). It exhibited a depth-independent trend after a steep dose gradient region. The signal depletion per readout was negligible (0.02%), with expected deviation for angular dependence due to off-axis sensitive volume, ranging from 1 to 16%. The residual signal of the OSLDs after 1 day bleached was within 1.5%. The accumulated and bleached OSLD signals had a standard deviation of ± 0.78 and ± 0.18 Gy, respectively. The TPS was found to underestimate the measured doses with deviations of 5% in OSLD, 17% in the Farmer ionisation chamber, and 7 and 8% for bladder and rectal diode probes. Discrepancies can be due to the positional uncertainty in the high-dose gradient. This demonstrates a slight displacement of the organ at risk near the steep dose gradient region will result in a large dose uncertainty. This justifies the importance of in vivo measurements in cobalt-60 HDR brachytherapy.
- 13 May 2018
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 41 (2) , 475-485
Dosimetric characterisation of the optically-stimulated luminescence dosimeter in cobalt-60 high dose rate brachytherapy system
This study investigates the characteristics and application of the optically-stimulated luminescence dosimeter (OSLD) in cobalt-60 high dose rate (HDR) brachytherapy, and compares the results with the dosage produced by the treatment planning system (TPS). The OSLD characteristics comprised linearity, reproducibility, angular dependence, depth dependence, signal depletion, bleaching rate and cumulative dose measurement. A phantom verification exercise was also conducted using the Farmer ionisation chamber and in vivo diodes. The OSLD signal indicated a supralinear response (R2 = 0.9998). It exhibited a depth-independent trend after a steep dose gradient region. The signal depletion per readout was negligible (0.02%), with expected deviation for angular dependence due to off-axis sensitive volume, ranging from 1 to 16%. The residual signal of the OSLDs after 1 day bleached was within 1.5%. The accumulated and bleached OSLD signals had a standard deviation of ± 0.78 and ± 0.18 Gy, respectively. The TPS was found to underestimate the measured doses with deviations of 5% in OSLD, 17% in the Farmer ionisation chamber, and 7 and 8% for bladder and rectal diode probes. Discrepancies can be due to the positional uncertainty in the high-dose gradient. This demonstrates a slight displacement of the organ at risk near the steep dose gradient region will result in a large dose uncertainty. This justifies the importance of in vivo measurements in cobalt-60 HDR brachytherapy.
- 1 March 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 144, 76-84
Characterisation of a MOSFET-based detector for dose measurement under megavoltage electron beam radiotherapy
- 1 March 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 144, 76-84
Characterisation of a MOSFET-based detector for dose measurement under megavoltage electron beam radiotherapy
- 1 October 2017
- Published by Elsevier in Physica Medica
- Vol. 42, 39-46
Dosimetric evaluation near lung and soft tissue interface region during respiratory-gated and non-gated radiotherapy: A moving phantom study
- 1 October 2017
- Published by Elsevier in Physica Medica
- Vol. 42, 39-46
Dosimetric evaluation near lung and soft tissue interface region during respiratory-gated and non-gated radiotherapy: A moving phantom study
- 28 February 2017
- Published by Elsevier in Physica Medica
- Vol. 35, 66-72
Influence of exposure and geometric parameters on absorbed doses associated with common neuro-interventional procedures
- 28 February 2017
- Published by Elsevier in Physica Medica
- Vol. 35, 66-72
Influence of exposure and geometric parameters on absorbed doses associated with common neuro-interventional procedures
- 6 January 2017
- Published by Elsevier in Physica Medica
- Vol. 33, 127-135
“Edge-on” MOSkin detector for stereotactic beam measurement and verification
- 6 January 2017
- Published by Elsevier in Physica Medica
- Vol. 33, 127-135
“Edge-on” MOSkin detector for stereotactic beam measurement and verification
- 9 December 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 175 (3) , 357-362
Evaluation of Imaging Dose From Different Image Guided Systems During Head and Neck Radiotherapy: A Phantom Study
This work evaluated and compared the absorbed doses to selected organs in the head and neck region from the three image guided radiotherapy systems: cone-beam computed tomography (CBCT) and kilovoltage (kV) planar imaging using the On-board Imager® (OBI) as well as the ExacTrac® X-ray system, all available on the Varian Novalis TX linear accelerator. The head and neck region of an anthropomorphic phantom was used to simulate patients’ head within the imaging field. Nanodots optically stimulated luminescent dosemeters were positioned at selected sites to measure the absorbed doses. CBCT was found to be delivering the highest dose to internal organs while OBI-2D gave the highest doses to the eye lenses. The setting of half-rotation in CBCT effectively reduces the dose to the eye lenses. Daily high-quality CBCT verification was found to increase the secondary cancer risk by 0.79%.
- 9 December 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 175 (3) , 357-362
Evaluation of Imaging Dose From Different Image Guided Systems During Head and Neck Radiotherapy: A Phantom Study
This work evaluated and compared the absorbed doses to selected organs in the head and neck region from the three image guided radiotherapy systems: cone-beam computed tomography (CBCT) and kilovoltage (kV) planar imaging using the On-board Imager® (OBI) as well as the ExacTrac® X-ray system, all available on the Varian Novalis TX linear accelerator. The head and neck region of an anthropomorphic phantom was used to simulate patients’ head within the imaging field. Nanodots optically stimulated luminescent dosemeters were positioned at selected sites to measure the absorbed doses. CBCT was found to be delivering the highest dose to internal organs while OBI-2D gave the highest doses to the eye lenses. The setting of half-rotation in CBCT effectively reduces the dose to the eye lenses. Daily high-quality CBCT verification was found to increase the secondary cancer risk by 0.79%.
- 1 November 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (11) , 1466-1474
In vivo skin dose measurement using MOSkin detectors in tangential breast radiotherapy
- 1 November 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (11) , 1466-1474
In vivo skin dose measurement using MOSkin detectors in tangential breast radiotherapy
- Open Access
- 23 March 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 694 (1) , 012015
Dose profile measurements during respiratory-gated lung stereotactic radiotherapy: A phantom study
During stereotactic body radiotherapy, high radiation dose (~60 Gy) is delivered to the tumour in small fractionation regime. In this study, the dosimetric characteristics were studied using radiochromic film during respiratory-gated and non-gated lung stereotactic body radiotherapy (SBRT). Specifically, the effect of respiratory cycle and amplitude, as well as gating window on the dosimetry were studied. In this study, the dose profiles along the irradiated area were measured. The dose profiles for respiratory-gated radiation delivery with different respiratory or tumour motion amplitudes, gating windows and respiratory time per cycle were in agreement with static radiation delivery. The respiratory gating system was able to deliver the radiation dose accurately (?1.05 mm) in the longitudinal direction. Although the treatment time for respiratory-gated SBRT was prolonged, this approach can potentially reduce the margin for internal tumour volume without compromising the tumour coverage. In addition, the normal tissue sparing effect can be improved.
- 23 March 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 694 (1) , 012015
Open AccessDose profile measurements during respiratory-gated lung stereotactic radiotherapy: A phantom study
During stereotactic body radiotherapy, high radiation dose (~60 Gy) is delivered to the tumour in small fractionation regime. In this study, the dosimetric characteristics were studied using radiochromic film during respiratory-gated and non-gated lung stereotactic body radiotherapy (SBRT). Specifically, the effect of respiratory cycle and amplitude, as well as gating window on the dosimetry were studied. In this study, the dose profiles along the irradiated area were measured. The dose profiles for respiratory-gated radiation delivery with different respiratory or tumour motion amplitudes, gating windows and respiratory time per cycle were in agreement with static radiation delivery. The respiratory gating system was able to deliver the radiation dose accurately (?1.05 mm) in the longitudinal direction. Although the treatment time for respiratory-gated SBRT was prolonged, this approach can potentially reduce the margin for internal tumour volume without compromising the tumour coverage. In addition, the normal tissue sparing effect can be improved.