MSManohar Singh

Manohar Singh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Manohar Singh has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel ROCOF Frequency-Voltage Assisted Steamless Grid Islanding Scheme

    by Manohar Singh

    Electric grids are designed to transfer bulk power from remote generating stations to load centers. Electric grids are highly interconnected to enhance power reliability and network stability. The resiliency of the electric grid against the network and load dynamics was enhanced through better inter-and inter-regional network connectivity. However, high dynamic inertia offers better damping against the transient stability dynamics prevailing on the electric grid. However, in some extreme grid disturbances, large losses of generation/loads may occur due to cascading tripping of protective relays and the centralised grid is split into smaller island grids through the protective defence mechanism. During this transition, either generation or load changes may be in bigger blocks, which may adversely affect frequency control and may be a challenge for the survival of grid islanding schemes. The main contribution of this research article is to design a grid islanding scheme for seamless transition of a centralised grid to an island grid. The novelty of the proposed scheme lies in the algorithm that works in balancing the load-generation in the island grid and minimising the bulk change in load through a rate of change of frequency (ROCOF) and under-frequency (UF) voltage-assisted islanding scheme by reconnection of the load in smaller blocks. The proposed scheme results in slow and less steep changes in frequency, arising and enhancing the feasibility of the proposed grid islanding scheme. The proposed frequency-voltage-assisted schemes have been designed for the Agra-Lalitpur region in the Indian grid in a PSS/E simulation environment.

  • Experiences With Controlled Islanding and Relay Coordination in Lalitpur Power System, India

    by Hemasundar Jakkula, Pratyasa Bhui, Animesh Kumar Sahoo, Sagnik Basumallik, Manohar Singh

    The formation of a power island, encompassing generating plants and nearby critical loads, is a strategy employed to maintain the operation of generating plants and the supply of power to essential services during potential blackouts. This paper presents a robust frequency stabilization strategy for such islands during blackouts in the main grid. The proposed methodology includes: (i) a three-stage under-frequency load shedding (UFLS) scheme that disconnects loads in large blocks to limit frequency decline; (ii) reconnection of shedded loads in smaller blocks in case of frequency rise after load shedding to maintain generationload balance; and (iii) a selective generator tripping scheme based on the estimated time to critical frequency, improving over traditional frequency or ROCOF-based methods. Load shedding locations are selected using voltage security criteria, and the entire protection scheme operates using only local measurements, removing reliance on communication infrastructure. The relay settings were tested in PSS/E for system data of Agra-Lalitpur region of Indian grid including renewables for varying operating conditions. It was also found that with grid supporting renewables, the frequency nadir improves with increasing renewables while frequency droop does not have much impact. The results have been shared with, and accepted by, the utility for potential implementation in the future.


  • Open Access

    Performance of Distance Relaying Scheme under High Penetration of RES

    by Janmejaya Pradhan, Manohar Singh

    The operation of a distance relay is a function of source impedance and fault parameters. The performance of a distance relay is quite stable when used for the protection of a strong power system network where the fault current contribution is dominated by synchronous machines. However, their performance is affected when the synchronous machine is replaced by high internal impedance-based generation as seen in the case of renewable energy source (RES) based generating units like solar and wind. The RES results in an observable increase in source to impedance ratio (SIR) and significantly affects the operating performance of a distance relay. The dynamic change in infeed in the RES system leads to overreach and under-reach problems. The dynamic nature of RES arises revision in the reach settings of the distance relay placed in the RES integrated network. This problem is stimulated for a model transmission system in the real-time digital simulator with hardware in loop simulation installed at Central Power Research Institute Bangalore, India. The performance of the relay is studied for high SIR, infeed variation, and load encroachment. Observation and simulation results recommend the rising requirement of an adaptive distance relaying protection scheme that can dynamically manage the relay zone setting as per the operation network configurations.

  • Experimental and theoretical investigations on fullerene (C 60 ) induced compact CH 3 NH 3 PbI 3 perovskite thin films

    by Virendra Kumar, Anand Pandey, Lokendra Kumar, Manohar Singh, Ashwani Kumar, Shyam Kishor, Kalpna Jain, Khundrakpma Saratchandra Singh, Beer Pal Singh

    In the present work, pure and Fullerene (C 60 )-doped methyl ammonium lead halide (CH 3 NH 3 PbI 3 ) perovskite thin films were prepared on glass substrates by spin coating method at different concentrations of fullerene (C 60 ).The structural, morphological, and optical characteristics of as-prepared thin films were analysed using experimental and computational methods. The X-ray diffraction studies and their Reitveld refinement analysis of the samples confirms that all deposited perovskite thin films have tetragonal structure and are highly oriented along the (110) plane. The morphology of the perovskite films was investigated by field emission scanning electron microscope (FE-SEM). The elemental composition of perovskite thin films was confirmed by Energy Dispersive X-rays Analysis (EDAX). The addition of fullerene (C 60 ) resulted in the increase of grain size sand a more compact surface development of the perovskite thin films with fewer flaws as compared with perovskite thin films without (C 60 ) was evaluated. Also, geometrical, electronic and optical properties were studied by using the first principles DFT computational method. Optical properties have been studied experimentally and verified computationally. All the perovskite thin film samples exhibit direct band-gap which is suitable for solar cells applications.


  • Relay Coordination Algorithm with Limits on Minimum Operating Time of customized Time Inverse Relays Characteristics

    by Manohar Singh

    Operating time of overcurrent relays is minimized in most of the overcurrent relay coordination studies by minimizing the summation of operating time of the all main overcurrent relays. Nonstandard time inverse overcurrent relay characteristics are further used for minimization of operating time of overcurrent relays in the distribution system where fault current contribution from the distributed energy resources (DER) is extremely weak. In practical, this fast optimized operating time of relay is very hard to realize in field. If this fast operating time is realized in field, then it may cause unwanted tripping of feeders during the network temporary faults. This article discusses a modified relay coordination algorithm in which, a lower limit is provided on the operating time of overcurrent relays to block their operation during the temporary fault periods. In addition to this contribution, the application of the customized time-inverse relay characteristics are also extended for maintaining the relay coordination in distribution system with integration of distributed energy resources.


  • Coordinated control among PSS, WTG and BESS for improving Small-Signal Stability

    by Feba Alias, Manohar Singh

    The goal towards attaining a sustainable future has led to the rapid increase in the integration of converter control based generators (CCBGs). The low inertia response characteristics of CCBGs and the weak tie lines in interconnected systems pose a huge threat to Small-Signal Stability (SSS). Adequate damping of low-frequency oscillations (LFO) is pivotal in ensuring the maximum power transfer through the critical transmission corridors. These operational issues become more serious with the significant reduction in system inertia as a result of the high penetration of CCBGs. Therefore, appropriate control techniques are an absolute requirement for preventing LFOs from limiting the penetration of CCBGs in interconnected networks. This may also eventually lead to revisions in grid codes mandating CCBGs to provide auxiliary damping control. But, the progressive addition of multiple damping controllers for specific target modes can lead to the drifting of eigenvalues (EVs) associated with other electromechanical modes (EMs) in the system. This is due to the adverse interactions between multiple damping controllers in the uncoordinated control approach and may result in deteriorating SSS. Therefore, this paper proposes a simultaneous coordinated control among Battery Energy Storage System (BESS), Wind Turbine Generators (WTG) and Power System Stabilizer (PSS) for enhancing SSS in networks with high wind penetration by considering both inter-area (IA) and local modes. The performance of the proposed coordinated control is corroborated using IEEE 68 bus system for multiple operating scenarios for which the critical modes in the system have the lowest damping index (DI). The effectiveness of modulating the active power, reactive power and simultaneous modulation of both active and reactive power injected by BESS along with a dual-channel Optimized WTG Damping Controller (DOWDC) and PSS is evaluated. The impact of the different coordinated control strategies on voltage dynamics is also investigated. The simulation results validate the better performance of the proposed coordinated control over uncoordinated control approaches.


  • Open Access

    Voltage–current–time inverse‐based protection coordination of photovoltaic power systems

    by Manohar Singh, Anubha Agrawal

    Increasing share of distributed energy resources (DERs) in power networks results in dynamic network topology and short‐circuit fault levels. Low fault infeed in PV connected power network will rarely damage any power components, but detection of faults is of prime importance. The existing over‐current, voltage, and impedance‐based relays may fail to detect/clear the faults. However, it is observed that PV infeed networks are generally weak and experience a collapse in terminal voltage with increase in current during the system faults. In this article, variation in fault currents and voltages is utilised for formulating a new voltage‐current‐time inverse (VCTI) mathematical relay model. The proposed relay model enhances the operating time of the relays and maintains the protection coordination for weak power networks, especially powered with high PV generation. Using this relay model, a cluster‐based protection coordination scheme for PV‐dominant penetrated power network is presented. The performance of the proposed relay model and coordination schemes is compared with inverse definite minimum time (IDMT) relays and other relying models. Based on the proposed relay model, a hardware relay prototype model has been developed and it is found that hardware results are highly stable and are within 3% accuracy of simulated results.