Jonathan Suter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonathan Suter has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
Xudong Fan
University of Michigan 1 Department of Biomedical Engineering 1101 Beal Ave., Ann Arbor, Michigan 48109, USA
21 shared publicationsIan M. White
Fischell Department of Bioengineering, 2241 Kim Engineering Building, College Park, Maryland 20742, USA
19 shared publicationsHongying Zhu
University of Missouri
17 shared publicationsYuze Sun
University of Michigan 1 Department of Biomedical Engineering 1101 Beal Ave., Ann Arbor, Michigan 48109, USA
10 shared publications- Xudong Fan
University of Missouri
9 shared publications Daniel J. Howard
7 shared publications
Latest Publications
- 1 June 2021
- Published by Office of Scientific and Technical Information (OSTI)
Neural Interactive Machine Learning (Final Report: Compilation of presentation material) [Slides]
How can we use biometric data to build better human-machine interfaces?
- 1 June 2021
- Published by Office of Scientific and Technical Information (OSTI)
Neural Interactive Machine Learning (Final Report: Compilation of presentation material) [Slides]
How can we use biometric data to build better human-machine interfaces?
- 24 September 2019
- Published by Office of Scientific and Technical Information (OSTI)
Evaluation of Nondestructive Examination Responses from Chloride-Induced Stress Corrosion Cracks: Fabrication of Base Metal Test Specimens
This is a draft TLR for the NRC describing the fabrication of NDE specimens containing actual SCC flaws for evaluating NDE responses from CISCC flaws for dry storage cask applications.
- 24 September 2019
- Published by Office of Scientific and Technical Information (OSTI)
Evaluation of Nondestructive Examination Responses from Chloride-Induced Stress Corrosion Cracks: Fabrication of Base Metal Test Specimens
This is a draft TLR for the NRC describing the fabrication of NDE specimens containing actual SCC flaws for evaluating NDE responses from CISCC flaws for dry storage cask applications.
- 11 May 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (6) , 1192-1197
Dynamics of molecular emission features from nanosecond, femtosecond laser and filament ablation plasmas
The evolutionary paths of molecular and nanoparticle formation in laser ablation plumes are not well understood due to the complexity of numerous physical processes that occur simultaneously in a transient laser-produced plasma system.
- 11 May 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (6) , 1192-1197
Dynamics of molecular emission features from nanosecond, femtosecond laser and filament ablation plasmas
The evolutionary paths of molecular and nanoparticle formation in laser ablation plumes are not well understood due to the complexity of numerous physical processes that occur simultaneously in a transient laser-produced plasma system.
- 15 March 2016
- Published by Wiley in Journal of Biophotonics
- Vol. 9 (6) , 656-666
In situnon-destructive measurement of biofilm thickness and topology in an interferometric optical microscope
Biofilms are ubiquitous and impact the environment, human health, dental hygiene, and a wide range of industrial processes. Biofilms are difficult to characterize when fully hydrated, especially in a non-destructive manner, because of their soft structure and water-like bulk properties. Herein a method of measuring and monitoring the thickness and topology of live biofilms of using white light interferometry is described. Using this technique, surface morphology, surface roughness, and biofilm thickness were measured over time without while the biofilm continued to grow. The thickness and surface topology of a P. putida biofilm were monitored growing from initial colonization to a mature biofilm. Measured thickness followed expected trends for bacterial growth. Surface roughness also increased over time and was a leading indicator of biofilm growth.
- 15 March 2016
- Published by Wiley in Journal of Biophotonics
- Vol. 9 (6) , 656-666
In situnon-destructive measurement of biofilm thickness and topology in an interferometric optical microscope
Biofilms are ubiquitous and impact the environment, human health, dental hygiene, and a wide range of industrial processes. Biofilms are difficult to characterize when fully hydrated, especially in a non-destructive manner, because of their soft structure and water-like bulk properties. Herein a method of measuring and monitoring the thickness and topology of live biofilms of using white light interferometry is described. Using this technique, surface morphology, surface roughness, and biofilm thickness were measured over time without while the biofilm continued to grow. The thickness and surface topology of a P. putida biofilm were monitored growing from initial colonization to a mature biofilm. Measured thickness followed expected trends for bacterial growth. Surface roughness also increased over time and was a leading indicator of biofilm growth.
- Open Access
- 21 September 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (20) , 25553-25569
Characterization of a swept external cavity quantum cascade laser for rapid broadband spectroscopy and sensing
The performance of a rapidly swept external cavity quantum cascade laser (ECQCL) system combined with an open-path Herriott cell was evaluated for time-resolved measurements of chemical species with broad and narrow absorption spectra. A spectral window spanning 1278 – 1390 cm−1 was acquired at a 200 Hz acquisition rate, corresponding to a tuning rate of 2x104 cm−1/s, with a spectral resolution of 0.2 cm−1. The capability of the ECQCL to measure < 100 ppbv changes in nitrous oxide (N2O) and 1,1,1,2-tetrafluoroethane (F134A) concentrations on millisecond timescales was demonstrated in simulated plume studies with releases near the open-path Herriott cell. Absorbance spectra measured using the ECQCL system exhibited noise-equivalent absorption coefficients of 5x10−9 cm−1Hz-1/2. For a spectrum acquisition time of 5 ms, noise-equivalent concentrations (NEC) for N2O and F134A were measured to be 70 and 16 ppbv respectively, which improved to sub-ppbv levels with averaging to 100 s. Noise equivalent column densities of 0.64 and 0.25 ppmv × m in 1 sec are estimated for N2O and F134A.
- 21 September 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (20) , 25553-25569
Open AccessCharacterization of a swept external cavity quantum cascade laser for rapid broadband spectroscopy and sensing
The performance of a rapidly swept external cavity quantum cascade laser (ECQCL) system combined with an open-path Herriott cell was evaluated for time-resolved measurements of chemical species with broad and narrow absorption spectra. A spectral window spanning 1278 – 1390 cm−1 was acquired at a 200 Hz acquisition rate, corresponding to a tuning rate of 2x104 cm−1/s, with a spectral resolution of 0.2 cm−1. The capability of the ECQCL to measure < 100 ppbv changes in nitrous oxide (N2O) and 1,1,1,2-tetrafluoroethane (F134A) concentrations on millisecond timescales was demonstrated in simulated plume studies with releases near the open-path Herriott cell. Absorbance spectra measured using the ECQCL system exhibited noise-equivalent absorption coefficients of 5x10−9 cm−1Hz-1/2. For a spectrum acquisition time of 5 ms, noise-equivalent concentrations (NEC) for N2O and F134A were measured to be 70 and 16 ppbv respectively, which improved to sub-ppbv levels with averaging to 100 s. Noise equivalent column densities of 0.64 and 0.25 ppmv × m in 1 sec are estimated for N2O and F134A.
- 23 May 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9456, 94560C-94560C-7
Optically resonant subwavelength films for tamper-indicating tags and seals
- 23 May 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9456, 94560C-94560C-7
Optically resonant subwavelength films for tamper-indicating tags and seals
- 22 May 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9455, 945503-945503-8
Subwavelength films for standoff radiation dosimetry
- 22 May 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9455, 945503-945503-8
Subwavelength films for standoff radiation dosimetry
- 2 April 2015
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1650 (1) , 1476-1485
Meso-scale magnetic signatures for nuclear reactor steel irradiation embrittlement monitoring
Verifying the structural integrity of passive components in light water and advanced reactors will be necessary to ensure safe, long-term operations of the existing U.S. nuclear fleet. This objective can be achieved through nondestructive condition monitoring techniques, which can be integrated with plant operations to quantify the “state of health” of structural materials in real-time. While nondestructive methods for monitoring many classes of degradation (such as fatigue or stress corrosion cracking) are relatively advanced, this is not the case for degradation caused by irradiation. The development of nondestructive evaluation technologies for these types of degradation will require advanced materials characterization techniques and tools that enable comprehensive understanding of nuclear reactor material microstructural and behavioral changes under extreme operating environments. Irradiation-induced degradation of reactor steels causes changes in their microstructure that impacts their micro-magnetic properties. In this paper, we describe preliminary results of integrating advanced material characterization techniques with meso-scale computational models. In the future, this will help to provide an interpretive understanding of the state of degradation in structural materials. Microstructural data are presented from monocrystalline Fe and are correlated with variable-field magnetic force microscopy and micro-magnetic measurements. Ongoing research is focused on extending the measurements and models on thin films to gain insights into the structural state of irradiated materials and the resulting impact on magnetic properties. Preliminary conclusions from these correlations are presented, and next steps described.
- 2 April 2015
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1650 (1) , 1476-1485
Meso-scale magnetic signatures for nuclear reactor steel irradiation embrittlement monitoring
Verifying the structural integrity of passive components in light water and advanced reactors will be necessary to ensure safe, long-term operations of the existing U.S. nuclear fleet. This objective can be achieved through nondestructive condition monitoring techniques, which can be integrated with plant operations to quantify the “state of health” of structural materials in real-time. While nondestructive methods for monitoring many classes of degradation (such as fatigue or stress corrosion cracking) are relatively advanced, this is not the case for degradation caused by irradiation. The development of nondestructive evaluation technologies for these types of degradation will require advanced materials characterization techniques and tools that enable comprehensive understanding of nuclear reactor material microstructural and behavioral changes under extreme operating environments. Irradiation-induced degradation of reactor steels causes changes in their microstructure that impacts their micro-magnetic properties. In this paper, we describe preliminary results of integrating advanced material characterization techniques with meso-scale computational models. In the future, this will help to provide an interpretive understanding of the state of degradation in structural materials. Microstructural data are presented from monocrystalline Fe and are correlated with variable-field magnetic force microscopy and micro-magnetic measurements. Ongoing research is focused on extending the measurements and models on thin films to gain insights into the structural state of irradiated materials and the resulting impact on magnetic properties. Preliminary conclusions from these correlations are presented, and next steps described.
- 12 September 2014
- Published by Office of Scientific and Technical Information (OSTI)
Instrumentation: Nondestructive Examination for Verification of Canister and Cladding Integrity. FY2014 Status Update
This report documents FY14 efforts for two instrumentation subtasks under storage and transportation. These instrumentation tasks relate to developing effective nondestructive evaluation (NDE) methods and techniques to (1) verify the integrity of metal canisters for the storage of used nuclear fuel (UNF) and to (2) verify the integrity of dry storage cask internals.
- 12 September 2014
- Published by Office of Scientific and Technical Information (OSTI)
Instrumentation: Nondestructive Examination for Verification of Canister and Cladding Integrity. FY2014 Status Update
This report documents FY14 efforts for two instrumentation subtasks under storage and transportation. These instrumentation tasks relate to developing effective nondestructive evaluation (NDE) methods and techniques to (1) verify the integrity of metal canisters for the storage of used nuclear fuel (UNF) and to (2) verify the integrity of dry storage cask internals.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Progress towards prognostic health management of passive components in advanced small modular reactors
Sustainable nuclear power to promote energy security and to reduce greenhouse gas emissions are two key national energy priorities. The development of deployable small modular reactors (SMRs) is expected to support these objectives by developing technologies that improve the reliability, sustain safety, and improve affordability of new reactors. Advanced SMRs (AdvSMRs) refer to a specific class of SMRs and are based on modularization of advanced reactor concepts. Prognostic health management (PHM) systems can benefit both the safety and economics of deploying AdvSMRs and can play an essential role in managing the inspection and maintenance of passive components in AdvSMR systems. This paper describes progress on development of an experimental setup for testing and validation of PHM systems for AdvSMR passive components. The experimental set-up for validation of prognostic algorithms is focused on thermal creep degradation as the prototypic degradation mechanism. The test bed enables accelerated thermal creep aging of materials relevant to AdvSMRs along with multiple nondestructive evaluation (NDE) measurements for assessment of thermal creep damage. NDE techniques include eddy current, magnetic Barkhausen noise (MBN), and linear and non-linear ultrasonic measurements. Details of the test-bed design as well as initial measurements results for specimens at different levels of thermal creep damage are presented.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Progress towards prognostic health management of passive components in advanced small modular reactors
Sustainable nuclear power to promote energy security and to reduce greenhouse gas emissions are two key national energy priorities. The development of deployable small modular reactors (SMRs) is expected to support these objectives by developing technologies that improve the reliability, sustain safety, and improve affordability of new reactors. Advanced SMRs (AdvSMRs) refer to a specific class of SMRs and are based on modularization of advanced reactor concepts. Prognostic health management (PHM) systems can benefit both the safety and economics of deploying AdvSMRs and can play an essential role in managing the inspection and maintenance of passive components in AdvSMR systems. This paper describes progress on development of an experimental setup for testing and validation of PHM systems for AdvSMR passive components. The experimental set-up for validation of prognostic algorithms is focused on thermal creep degradation as the prototypic degradation mechanism. The test bed enables accelerated thermal creep aging of materials relevant to AdvSMRs along with multiple nondestructive evaluation (NDE) measurements for assessment of thermal creep damage. NDE techniques include eddy current, magnetic Barkhausen noise (MBN), and linear and non-linear ultrasonic measurements. Details of the test-bed design as well as initial measurements results for specimens at different levels of thermal creep damage are presented.