Xudong Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xudong Fan has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Ian M. White
13 shared publicationsYuze Sun
Department of Biological Engineering 240D Bond Life Sciences Center, University of Missouri, 1201 E Rollins Street, Columbia, Missouri 65211, USA
11 shared publications- Jonathan Suter
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
9 shared publications Hongying Zhu
University of Missouri
7 shared publicationsSiyka I. Shopova
6 shared publicationsGreg Frye-Mason
ICx Biodefense, 4343 Pan American Freeway NE, Suite 234, Albuquerque, NM, USA
4 shared publications
Latest Publications
- 3 November 2009
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (1) , 165-171
Rapid tandem-column micro-gas chromatography based on optofluidic ring resonators with multi-point on-column detection
We demonstrated a novel tandem-column micro-gas chromatography (μGC) based on optofluidic ring resonator (OFRR). The OFRR is a thin-walled fused silica capillary whose interior surface is coated with a polymeric stationary phase. The circular cross section of the OFRR forms the micro-ring resonator and supports whispering gallery modes (WGMs). Via tapered optical fibers in contact with the OFRR, the WGM can be excited externally at any positions along the OFRR capillary, thus enabling multi-point, on-column, real-time detection of vapor molecules flowing through the OFRR. In the present OFRR-based tandem-column-based μGC implementation, a 180 cm long conventional GC column coated with a nonpolar stationary phase was followed by a relatively short OFRR column coated with a polar phase. Two detection positions, one at the inlet of the OFRR and the other a few centimeters downstream, were used to monitor the separation achieved by the first and the second column, respectively. Owing to the multi-point on-column detection that provides complementary retention time information on each chemical compound, co-eluted analytes can be well separated and identified on at least one detection channel and no modulation is needed at the interface of tandem columns. Separation and detection of twelve analytes with various volatilities and polarities within four minutes were demonstrated. In addition, the chromatograms obtained from three different locations along the OFRR column demonstrated the system's capability of on-column monitoring of the separation process for the target analyte in a vapor mixture. Our results will lead to the development of a rapid, simple, and portable μGC system with significantly improved selectivity and chemical identification capabilities.
- 3 November 2009
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (1) , 165-171
Rapid tandem-column micro-gas chromatography based on optofluidic ring resonators with multi-point on-column detection
We demonstrated a novel tandem-column micro-gas chromatography (μGC) based on optofluidic ring resonator (OFRR). The OFRR is a thin-walled fused silica capillary whose interior surface is coated with a polymeric stationary phase. The circular cross section of the OFRR forms the micro-ring resonator and supports whispering gallery modes (WGMs). Via tapered optical fibers in contact with the OFRR, the WGM can be excited externally at any positions along the OFRR capillary, thus enabling multi-point, on-column, real-time detection of vapor molecules flowing through the OFRR. In the present OFRR-based tandem-column-based μGC implementation, a 180 cm long conventional GC column coated with a nonpolar stationary phase was followed by a relatively short OFRR column coated with a polar phase. Two detection positions, one at the inlet of the OFRR and the other a few centimeters downstream, were used to monitor the separation achieved by the first and the second column, respectively. Owing to the multi-point on-column detection that provides complementary retention time information on each chemical compound, co-eluted analytes can be well separated and identified on at least one detection channel and no modulation is needed at the interface of tandem columns. Separation and detection of twelve analytes with various volatilities and polarities within four minutes were demonstrated. In addition, the chromatograms obtained from three different locations along the OFRR column demonstrated the system's capability of on-column monitoring of the separation process for the target analyte in a vapor mixture. Our results will lead to the development of a rapid, simple, and portable μGC system with significantly improved selectivity and chemical identification capabilities.
- 31 July 2009
- Published by Springer Nature
- p. 123-143
Rapid Chemical Vapor Detection Using Optofluidic Ring Resonators
- 31 July 2009
- Published by Springer Nature
- p. 123-143
Rapid Chemical Vapor Detection Using Optofluidic Ring Resonators
- 31 July 2009
- Published by Springer Nature
- p. 513-531
Optofluidic Ring Resonator Dye Microlasers
- 31 July 2009
- Published by Springer Nature
- p. 377-393
Label-Free Biosensing with the Optofluidic Ring Resonator
- 31 July 2009
- Published by Springer Nature
- p. 377-393
Label-Free Biosensing with the Optofluidic Ring Resonator
- 31 July 2009
- Published by Springer Nature
- p. 1-4
General Introduction
- 25 March 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (7) , 1042-1044
Robust integrated optofluidic-ring-resonator dye lasers
We demonstrate a robust optofluidic dye laser that integrates fluidics with a high Q-factor ring resonator. In this optofluidic laser the ring resonator is formed by an optical fiber fused on the inner surface of a glass capillary serving as a fluidic channel. Laser oscillation is achieved with a threshold of per pulse. Furthermore, the laser emission can be directionally outcoupled through a fiber prism for easy and efficient light delivery.- 25 March 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (7) , 1042-1044
Robust integrated optofluidic-ring-resonator dye lasers
We demonstrate a robust optofluidic dye laser that integrates fluidics with a high Q-factor ring resonator. In this optofluidic laser the ring resonator is formed by an optical fiber fused on the inner surface of a glass capillary serving as a fluidic channel. Laser oscillation is achieved with a threshold of per pulse. Furthermore, the laser emission can be directionally outcoupled through a fiber prism for easy and efficient light delivery.- 20 March 2009
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 134 (7) , 1386-1391
Optofluidic ring resonator sensors for rapid DNT vapor detection
We demonstrated rapid 2,4-dinitrotoluene (DNT) vapor detection at room temperature based on an optofluidic ring resonator (OFRR) sensor. With the unique on-column separation and detection features of OFRR vapor sensors, DNT can be identified from other interferences coexisting in the analyte sample mixture, which is especially useful in the detection of explosives from practical complicated vapor samples usually containing more volatile analytes. The DNT detection limit is approximately 200 pg, which corresponds to a solid phase microextraction (SPME) sampling time of only 1 second at room temperature from equilibrium headspace. A theoretical analysis was also performed to account for the experimental results. Our study shows that the OFRR vapor sensor is a promising platform for the development of a rapid, low-cost, and portable analytical device for explosive detection and monitoring.
- 20 March 2009
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 134 (7) , 1386-1391
Optofluidic ring resonator sensors for rapid DNT vapor detection
We demonstrated rapid 2,4-dinitrotoluene (DNT) vapor detection at room temperature based on an optofluidic ring resonator (OFRR) sensor. With the unique on-column separation and detection features of OFRR vapor sensors, DNT can be identified from other interferences coexisting in the analyte sample mixture, which is especially useful in the detection of explosives from practical complicated vapor samples usually containing more volatile analytes. The DNT detection limit is approximately 200 pg, which corresponds to a solid phase microextraction (SPME) sampling time of only 1 second at room temperature from equilibrium headspace. A theoretical analysis was also performed to account for the experimental results. Our study shows that the OFRR vapor sensor is a promising platform for the development of a rapid, low-cost, and portable analytical device for explosive detection and monitoring.
- 10 February 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (4) , 2731-2738
Highly versatile fiber-based optical Fabry-Pérot gas sensor
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 10 February 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (4) , 2731-2738
Highly versatile fiber-based optical Fabry-Pérot gas sensor
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 1 January 2009
- Published by Springer Nature
- Vol. 503, 139-165
Label-Free Detection with the Liquid Core Optical Ring Resonator Sensing Platform
Optical label-free detection prevents the cost and complexity of fluorescence and radio labeling while providing accurate quantitative and kinetic results. We have developed a new optical label-free sensor called the liquid core optical ring resonator (LCORR). The LCORR integrates optical ring resonator sensors into the microfluidic delivery system by using glass capillaries with a thin wall. The LCORR is capable of performing refractive index detection on liquid samples, as well as bio/chemical analyte detection down to detection limits on the scale of pg/mm2 on a sensing surface.
- 1 January 2009
- Published by Springer Nature
- Vol. 503, 139-165
Label-Free Detection with the Liquid Core Optical Ring Resonator Sensing Platform
Optical label-free detection prevents the cost and complexity of fluorescence and radio labeling while providing accurate quantitative and kinetic results. We have developed a new optical label-free sensor called the liquid core optical ring resonator (LCORR). The LCORR integrates optical ring resonator sensors into the microfluidic delivery system by using glass capillaries with a thin wall. The LCORR is capable of performing refractive index detection on liquid samples, as well as bio/chemical analyte detection down to detection limits on the scale of pg/mm2 on a sensing surface.
- 26 November 2008
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 6 (3) , 425-429
Highly sensitive tuning of coupled optical ring resonators by microfluidics
- 26 November 2008
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 6 (3) , 425-429
Highly sensitive tuning of coupled optical ring resonators by microfluidics