Petr Parizek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Petr Parizek has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Ludek Haman
First Department of Internal Medicine Cardiology and Angiology, University Hospital Hradec Kralove, 500 05 Hradec Kralove, Czech Republic
16 shared publications Miloslav Tauchman
Department of Cardiovascular Medicine, University Hospital, Hradec Kralove, Czech Republic
5 shared publications- Radek Pudil
2nd Department of Medicine, Charles University, Prague, Faculty of Medicine, Hradec Králové
4 shared publications Miloslav Pleskot
1st Department of Internal Medicine , Faculty of Medicine, University Hospital, Charles University Prague , Sokolska 581, Hradec Kralove 500 05 , Czech Republic
3 shared publications- Vladimir Palicka
Institute of Clinical Biochemistry and Diagnostics, University Hospital Hradec Kralove and Faculty of Medicine in Hradec Kralove, Charles University, 50005 Hradec Kralove, Czech Republic
3 shared publications - Dan Wichterle
Department of Cardiology Institute for Clinical and Experimental Medicine Prague Czechia
2 shared publications
Latest Publications
- Open Access
- 30 March 2016
- Published by Palacky University Olomouc in Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia
- Vol. 160 (1) , 106-110
Increase of serum interleukin 6 and interferon γ is associated with the number of impulses in patients with supraventricular arrhythmias treated with radiofrequency catheter ablation
Activation of the immune system plays a pathogenic role in the process of myocardial remodeling in patients with supraventricular arrhythmias. The intensity of this process is associated with the effectiveness of electrical cardioversion and radiofrequency catheter ablation (RFA). The aim of this study was to test the ability of the biochip microarray to detect immune parameters in patients with supraventricular arrhythmias undergoing RFA treatment. We used a biochip-based microarray system to determine multiple immune parameters in a group of 35 patients who had undergone RFA for atrioventricular nodal reentry tachycardia (AVNRT), atrial flutter (AFL) and atrial fibrillation (AF). Before the procedure, serum IL-6 and VEGF levels were significantly increased in patients with atrial fibrillation compared to patients with AVNRT (IL-6: 6.4±6.3 ng/L vs. 1.5±0.7 ng/L, P < 0.01; VEGF: 132.4±74 ng/L vs. 88.5±56.4 ng/L, P < 0.01). After the procedure, serum IL-6, VEGF, IFN-γ and MCP-1 levels significantly increased compared to baseline (IL-6: 5.2±4.8 ng/L vs. 2.9±2.1 ng/L, P < 0.01; VEGF: 195.8±160 ng/L vs. 119.8± 110 ng/L, P < 0.05; IFN-γ: 3.1±1.2 ng/L vs. 2.3±0.6 ng/L, P < 0.05; MCP-1: 104.1±84.5 ng/L vs. 54.5±50 ng/L, P < 0.05). Serum IL-6 and IFN-γ were associated with the number of RFA applications (IL-6: r = 0.56, n 33; IFN-γ: r = 0.47, n 33). This study showed that biochip-based microarray can be useful in the detection of immune activation in patients with arrhythmias and can detect myocardial injury after RF procedures.
- 30 March 2016
- Published by Palacky University Olomouc in Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia
- Vol. 160 (1) , 106-110
Open AccessIncrease of serum interleukin 6 and interferon γ is associated with the number of impulses in patients with supraventricular arrhythmias treated with radiofrequency catheter ablation
Activation of the immune system plays a pathogenic role in the process of myocardial remodeling in patients with supraventricular arrhythmias. The intensity of this process is associated with the effectiveness of electrical cardioversion and radiofrequency catheter ablation (RFA). The aim of this study was to test the ability of the biochip microarray to detect immune parameters in patients with supraventricular arrhythmias undergoing RFA treatment. We used a biochip-based microarray system to determine multiple immune parameters in a group of 35 patients who had undergone RFA for atrioventricular nodal reentry tachycardia (AVNRT), atrial flutter (AFL) and atrial fibrillation (AF). Before the procedure, serum IL-6 and VEGF levels were significantly increased in patients with atrial fibrillation compared to patients with AVNRT (IL-6: 6.4±6.3 ng/L vs. 1.5±0.7 ng/L, P < 0.01; VEGF: 132.4±74 ng/L vs. 88.5±56.4 ng/L, P < 0.01). After the procedure, serum IL-6, VEGF, IFN-γ and MCP-1 levels significantly increased compared to baseline (IL-6: 5.2±4.8 ng/L vs. 2.9±2.1 ng/L, P < 0.01; VEGF: 195.8±160 ng/L vs. 119.8± 110 ng/L, P < 0.05; IFN-γ: 3.1±1.2 ng/L vs. 2.3±0.6 ng/L, P < 0.05; MCP-1: 104.1±84.5 ng/L vs. 54.5±50 ng/L, P < 0.05). Serum IL-6 and IFN-γ were associated with the number of RFA applications (IL-6: r = 0.56, n 33; IFN-γ: r = 0.47, n 33). This study showed that biochip-based microarray can be useful in the detection of immune activation in patients with arrhythmias and can detect myocardial injury after RF procedures.
- 25 July 2014
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 29 (5) , 757-762
Thoracoscopic Radiofrequency Ablation for Lone Atrial Fibrillation: Box-Lesion Technique
We report the feasibility and outcomes of box-lesion ablation technique to treat stand-alone atrial fibrillation (AF). There were 41 patients with a mean age of 57.6 ± 8.0 years who underwent bilateral totally thoracoscopic ablation of symptomatic paroxysmal AF (n = 24; 58.5%), persistent AF (n = 9; 22.0%), or long-standing persistent AF (n = 8; 19.5%). The box-lesion procedure included bilateral pulmonary vein and left atrial posterior wall ablation using irrigated bipolar radiofrequency with documentation of conduction block. There were no intra- or perioperative ablation-related complications. There was no operative mortality, no myocardial infarction, and no stroke. Skin-to-skin procedure time was 119.5 ± 23.7 minutes and the postoperative average length of stay was 7.4 ± 2.5 days. At discharge, 38 patients (93%) were in sinus rhythm. Median follow-up time was 641 days (ranges, 185-1636 days). At six months postsurgery, 31 patients of 41 (76%) were free from AF without the need of antiarrhythmic drugs. One-year success rate was 73% (off antiarrhythmic drugs). Eight patients (19.5%) underwent catheter reablation. Thirty-six patients (90%) were in sinus rhythm at six months after the last performed ablation (surgical ablation or catheter reablation). At 12 months follow-up, 61% patients discontinued oral anticoagulant therapy. The thoracoscopic box-lesion ablation procedure is a safe, effective, and minimally invasive method for the treatment of isolated (lone) AF. This procedure provided excellent short-term freedom from AF.
- 25 July 2014
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 29 (5) , 757-762
Thoracoscopic Radiofrequency Ablation for Lone Atrial Fibrillation: Box-Lesion Technique
We report the feasibility and outcomes of box-lesion ablation technique to treat stand-alone atrial fibrillation (AF). There were 41 patients with a mean age of 57.6 ± 8.0 years who underwent bilateral totally thoracoscopic ablation of symptomatic paroxysmal AF (n = 24; 58.5%), persistent AF (n = 9; 22.0%), or long-standing persistent AF (n = 8; 19.5%). The box-lesion procedure included bilateral pulmonary vein and left atrial posterior wall ablation using irrigated bipolar radiofrequency with documentation of conduction block. There were no intra- or perioperative ablation-related complications. There was no operative mortality, no myocardial infarction, and no stroke. Skin-to-skin procedure time was 119.5 ± 23.7 minutes and the postoperative average length of stay was 7.4 ± 2.5 days. At discharge, 38 patients (93%) were in sinus rhythm. Median follow-up time was 641 days (ranges, 185-1636 days). At six months postsurgery, 31 patients of 41 (76%) were free from AF without the need of antiarrhythmic drugs. One-year success rate was 73% (off antiarrhythmic drugs). Eight patients (19.5%) underwent catheter reablation. Thirty-six patients (90%) were in sinus rhythm at six months after the last performed ablation (surgical ablation or catheter reablation). At 12 months follow-up, 61% patients discontinued oral anticoagulant therapy. The thoracoscopic box-lesion ablation procedure is a safe, effective, and minimally invasive method for the treatment of isolated (lone) AF. This procedure provided excellent short-term freedom from AF.
- 1 November 2012
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 54 (11-12) , e369-e374
Catheter ablation for atrial fibrillation - Single center experience
AimsCatheter ablation (CA) has become standard therapy for atrial fibrillation, especially for paroxysmal atrial fibrillation. Precise single center follow-up (FU) data (especially long-term FU data) are published infrequently.MethodsWe studied 303 consecutive patients (172 males, 131 females, mean age 57 years) who underwent catheter ablation for atrial fibrillation (489 procedures) in years 2004–2012. Clinical examination, ECG, 24-h or 7-day Holter monitoring and quality of life (QoL) measurement (EQ-5D) was performed at 3, 6, 12, 18 and 24-month FU.ResultsFU data longer than 6 month after the first procedure are available for 135 patients with paroxysmal, 84 patients with persistent and 48 patients with longstanding persistent AF. The success rate after 6 month after the first procedure (sinus rhythm without AA drugs, no arrhythmias) was 48% for paroxysmal, 43% for persistent and 44% for longstanding persistent AF. The complication rate was 3.3% (16 patients, no deaths, no pulmonary vein stenosis, 5 incidents of pericardial effusion treated with pericardiocentesis; 1 transitory ischemic attack; the remainder were local complications in the groin). The success rate after the last procedure (mean FU 24±16 month, 1.6 procedure per patient) was 80% for paroxysmal and 58% for persistent and longstanding persistent AF. QoL increased significantly in all groups of patients.ConclusionWith the standard procedure we can achieve acceptable results (success rate 60–80% with repeated procedures) with low complication rate even in a “lower volume” center. In selected patients (with paroxysmal AF preferring interventional treatment) can be CA recommended as first-line therapy for rhythm control. CA improves QoL in our patients with AF. As there is no gold standard to measure QoL in AF patients, EQ-5D seems to be a simple, quick and useful tool
- 1 November 2012
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 54 (11-12) , e369-e374
Catheter ablation for atrial fibrillation - Single center experience
AimsCatheter ablation (CA) has become standard therapy for atrial fibrillation, especially for paroxysmal atrial fibrillation. Precise single center follow-up (FU) data (especially long-term FU data) are published infrequently.MethodsWe studied 303 consecutive patients (172 males, 131 females, mean age 57 years) who underwent catheter ablation for atrial fibrillation (489 procedures) in years 2004–2012. Clinical examination, ECG, 24-h or 7-day Holter monitoring and quality of life (QoL) measurement (EQ-5D) was performed at 3, 6, 12, 18 and 24-month FU.ResultsFU data longer than 6 month after the first procedure are available for 135 patients with paroxysmal, 84 patients with persistent and 48 patients with longstanding persistent AF. The success rate after 6 month after the first procedure (sinus rhythm without AA drugs, no arrhythmias) was 48% for paroxysmal, 43% for persistent and 44% for longstanding persistent AF. The complication rate was 3.3% (16 patients, no deaths, no pulmonary vein stenosis, 5 incidents of pericardial effusion treated with pericardiocentesis; 1 transitory ischemic attack; the remainder were local complications in the groin). The success rate after the last procedure (mean FU 24±16 month, 1.6 procedure per patient) was 80% for paroxysmal and 58% for persistent and longstanding persistent AF. QoL increased significantly in all groups of patients.ConclusionWith the standard procedure we can achieve acceptable results (success rate 60–80% with repeated procedures) with low complication rate even in a “lower volume” center. In selected patients (with paroxysmal AF preferring interventional treatment) can be CA recommended as first-line therapy for rhythm control. CA improves QoL in our patients with AF. As there is no gold standard to measure QoL in AF patients, EQ-5D seems to be a simple, quick and useful tool
- 1 November 2012
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 54 (11-12) , e421-e427
Quality of life and costs of conventional therapy in patients treated by catheter ablation for atrial fibrillation
AimsThe purpose of the study was to assess quality of life, socioeconomic parameters, and costs of conventional therapy in patients treated by catheter ablation for atrial fibrillation (AF).MethodsThe study included 160 patients treated by catheter ablation for AF who fulfilled a minimum of 2-year follow-up. Quality of life using EQ-5D questionnaire, and days of hospitalization and working incapacity were evaluated before ablation and every 6 months after ablation. Further, one-year costs of conventional therapy for AF were assessed before and after ablation.ResultsQuality of life was significantly improved at each post-ablation stage. EQ-5D index increased from baseline 68±14 to 76±17 after 2 years (p<0.001), and EQ-VAS score from baseline 65±17 to 71±15 after 2 years (p=0.01). Significant reduction was further observed in the count of hospitalization days and days of working incapacity (both p<0.01). The cost of conventional therapy per patient per year decreased from 49,337 Czech Crowns (1974€) before ablation to 16.504 (660€) and 13.576 CZC (543€) in the first and second post-ablation year, respectively.ConclusionAF ablation was associated with significant improvement in quality of life, and decrease in days of hospitalization and working incapacity. There was more than three-fold reduction in the costs of conventional therapy observed in the first two years after ablation
- 1 November 2012
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 54 (11-12) , e421-e427
Quality of life and costs of conventional therapy in patients treated by catheter ablation for atrial fibrillation
AimsThe purpose of the study was to assess quality of life, socioeconomic parameters, and costs of conventional therapy in patients treated by catheter ablation for atrial fibrillation (AF).MethodsThe study included 160 patients treated by catheter ablation for AF who fulfilled a minimum of 2-year follow-up. Quality of life using EQ-5D questionnaire, and days of hospitalization and working incapacity were evaluated before ablation and every 6 months after ablation. Further, one-year costs of conventional therapy for AF were assessed before and after ablation.ResultsQuality of life was significantly improved at each post-ablation stage. EQ-5D index increased from baseline 68±14 to 76±17 after 2 years (p<0.001), and EQ-VAS score from baseline 65±17 to 71±15 after 2 years (p=0.01). Significant reduction was further observed in the count of hospitalization days and days of working incapacity (both p<0.01). The cost of conventional therapy per patient per year decreased from 49,337 Czech Crowns (1974€) before ablation to 16.504 (660€) and 13.576 CZC (543€) in the first and second post-ablation year, respectively.ConclusionAF ablation was associated with significant improvement in quality of life, and decrease in days of hospitalization and working incapacity. There was more than three-fold reduction in the costs of conventional therapy observed in the first two years after ablation
- 1 June 2012
- Published by Taylor & Francis in Acta Cardiologica
- Vol. 67 (3) , 311-316
Cardiac resynchronization therapy in clinical responders: right ventricular echocardiographic changes at mid-term follow-up
The objective of this study was to assess the mid-term effects of cardiac resynchronization therapy on systolic function and remodelling of the right ventricle in clinical responders and non-responders. A biventricular system was implanted between July 2005 and May 2008 in 58 patients with heart failure NYHA class II-IV. At baseline, three and 15 months after implantation, the following parameters were determined: NYHA class, quality of life, six-minute walk test, echocardiography including assessment of right ventricular systolic function by tricuspid annular plane systolic excursion and by pulsed tissue Doppler imaging (myocardial peak systolic velocity was measured at the tricuspid annulus). We also assessed the presence of ventricular dyssynchrony. There were no significant changes after three months of cardiac resynchronization therapy on right ventricular systolic function and remodelling in responders and non-responders. Among responders, we found a statistically significant improvement of right ventricular systolic function and also a significant decrease in the size of the right ventricle after 15 months of therapy (systolic excursion before therapy 17.8 +/- 4.0 mm vs. 19.4 +/- 3.7 mm, P < 0.05, after therapy; peak systolic velocity initially 11.9 +/- 2.9 cm/s vs 12.7 +/- 3.2 cm/s; right ventricle size before therapy 29.3 +/- 5.0 mm vs. 27.8 +/- 4.2 mm, P < 0.05, after therapy. These changes were not observed in non-responders. Fifteen months after cardiac resynchronization therapy, we found a statistically significant improvement of right ventricular systolic function and a significant reduction of right ventricular size in responders to cardiac resynchronization therapy.
- 1 June 2012
- Published by Taylor & Francis in Acta Cardiologica
- Vol. 67 (3) , 311-316
Cardiac resynchronization therapy in clinical responders: right ventricular echocardiographic changes at mid-term follow-up
The objective of this study was to assess the mid-term effects of cardiac resynchronization therapy on systolic function and remodelling of the right ventricle in clinical responders and non-responders. A biventricular system was implanted between July 2005 and May 2008 in 58 patients with heart failure NYHA class II-IV. At baseline, three and 15 months after implantation, the following parameters were determined: NYHA class, quality of life, six-minute walk test, echocardiography including assessment of right ventricular systolic function by tricuspid annular plane systolic excursion and by pulsed tissue Doppler imaging (myocardial peak systolic velocity was measured at the tricuspid annulus). We also assessed the presence of ventricular dyssynchrony. There were no significant changes after three months of cardiac resynchronization therapy on right ventricular systolic function and remodelling in responders and non-responders. Among responders, we found a statistically significant improvement of right ventricular systolic function and also a significant decrease in the size of the right ventricle after 15 months of therapy (systolic excursion before therapy 17.8 +/- 4.0 mm vs. 19.4 +/- 3.7 mm, P < 0.05, after therapy; peak systolic velocity initially 11.9 +/- 2.9 cm/s vs 12.7 +/- 3.2 cm/s; right ventricle size before therapy 29.3 +/- 5.0 mm vs. 27.8 +/- 4.2 mm, P < 0.05, after therapy. These changes were not observed in non-responders. Fifteen months after cardiac resynchronization therapy, we found a statistically significant improvement of right ventricular systolic function and a significant reduction of right ventricular size in responders to cardiac resynchronization therapy.
- 1 May 2012
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 54 (5-6) , e156-e161
Percutaneous exclusion of the left atrial appendage in prevention of systemic embolism
Left atrial appendage is the most frequent place of blood clot formation in heart cavities. The thrombus formation increases a risk of a systemic embolism especially in patients with a permanent atrial fibrillation. The standard preventive treatment is the oral anticoagulation therapy. Another possible a treatment is an exclusion of a left atrial appendage. We present current overview a risks and benefits of surgical and percutaneous elimination of a left atrial appendage. We present the first experience with Amplatzer Cardiac Plug system in an elimination of a left atrial appendage. We concluded that an exclusion of left atrial appendage could become a useful possibility of prevention of systemic embolization in patients with an atrial fibrillation, but is not still an alternative therapy for anticoagulation therapy at present
- 1 May 2012
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 54 (5-6) , e156-e161
Percutaneous exclusion of the left atrial appendage in prevention of systemic embolism
Left atrial appendage is the most frequent place of blood clot formation in heart cavities. The thrombus formation increases a risk of a systemic embolism especially in patients with a permanent atrial fibrillation. The standard preventive treatment is the oral anticoagulation therapy. Another possible a treatment is an exclusion of a left atrial appendage. We present current overview a risks and benefits of surgical and percutaneous elimination of a left atrial appendage. We present the first experience with Amplatzer Cardiac Plug system in an elimination of a left atrial appendage. We concluded that an exclusion of left atrial appendage could become a useful possibility of prevention of systemic embolization in patients with an atrial fibrillation, but is not still an alternative therapy for anticoagulation therapy at present
- 1 January 2012
- Vol. 70 (12) , 1250-7
Echocardiographic changes after cardiac resynchronisation therapy.
The aim of this prospective study was to evaluate echocardiographic changes in clinical responders and nonresponders after 3 and 15 months of cardiac resynchronisation therapy (CRT). Fifty eight patients in whom a biventricular system was implanted between 2005 and 2008 were followed up at 3 and at 15 months. Clinical and echocardiography parameters including intra- and interventricular dyssynchrony were assessed at baseline and after 3 and 15 months of CRT. Every patient in whom quality of life, New York Heart Association (NYHA) class and/or 6-minute walk test (6MWT) improved (improvement of ≥ 1 NYHA class, 6MWT by more than 10%), and who was neither in hospital for heart failure nor died for cardiac reasons, was categorised as a clinical responder. In the responders' group, we found a significant improvement of right ventricular systolic function and a decrease in the size of the right ventricle (RV) only after 15 months (tricuspid annular plane systolic excursion [TAPSE] 17.8 ± 4.0 mm to 19.4 ± 3.7 mm, p 〈 0.05, RV diameter 29.3 ± 5.0 mm to 27.8 ± 4.2 mm, p 〈 0.05). Significant improvement of other monitored parameters occurred 3 months after CRT implantation: left ventricle (LV) end-diastolic diameter 70.5 ± 7.8 mm to 66.1 ± 8.3 mm, p 〈 0.001, LV ejection fraction 22.0 ± 5.4% to 27.1 ± 9.8%, p 〈 0.05, pulmonary artery pressure (peak gradient of tricuspid regurgitation) 37.1 ± 14.8 mm Hg to 27.6 ± 8.9 mm Hg, p 〈 0.001, tricuspid regurgitation (grade) 1.9 ± 0.9 to 1.5 ± 0.6, p 〈 0.05, mitral regurgitation (grade) 2.6 ± 0.9 to 2.2 ± 0.9, p 〈 0.001, LV dP/dt max (peak positive rate of pressure rise [slope of mitral regurgitant jet]) 482.4 ± 155.4 mm Hg/s to 981.2 ± 654.5 mm Hg/s, p 〈 0.001, velocity time integral (VTI) in LV outflow tract (LVOT) 14.1 ± 4.3 cm to 16.7 ± 4.1 cm, p 〈 0.001. In the group of nonresponders, only 2 parameters improved significantly: LV dP/dt max 561.2 ± 347.9 mm Hg/s to 1024.5 ± 745.3 mm Hg/s, p 〈 0.001, and LVOT VTI 14.5 ± 3.0 cm to 16.3 ± 2.9 cm, p 〈 0.001. Other echocardiographic parameters did not show any important changes, and no changes occurred between 3 and 15 months. On the contrary, after 15 months we saw significant progression of tricuspid regurgitation in nonresponders. In multivariate analysis, combination of baseline delay between time to peak systolic velocity in ejection phase at basal septal and basal lateral segments (Ts-lateral-septal delay) and serum creatinine was a strong predictor of clinical CRT response (area under curve was 0.80, percentage of correct decision was 82%). In the group of responders, significant changes of most monitored echocardiographic parameters were observed 3 months after CRT implantation. The only parameters which changed significantly after 15 months, but not previously, were the systolic function of the RV and the decrease in the RV size. In the group of nonresponders, these changes were not observed.
- 1 January 2012
- Vol. 70 (12) , 1250-7
Echocardiographic changes after cardiac resynchronisation therapy.
The aim of this prospective study was to evaluate echocardiographic changes in clinical responders and nonresponders after 3 and 15 months of cardiac resynchronisation therapy (CRT). Fifty eight patients in whom a biventricular system was implanted between 2005 and 2008 were followed up at 3 and at 15 months. Clinical and echocardiography parameters including intra- and interventricular dyssynchrony were assessed at baseline and after 3 and 15 months of CRT. Every patient in whom quality of life, New York Heart Association (NYHA) class and/or 6-minute walk test (6MWT) improved (improvement of ≥ 1 NYHA class, 6MWT by more than 10%), and who was neither in hospital for heart failure nor died for cardiac reasons, was categorised as a clinical responder. In the responders' group, we found a significant improvement of right ventricular systolic function and a decrease in the size of the right ventricle (RV) only after 15 months (tricuspid annular plane systolic excursion [TAPSE] 17.8 ± 4.0 mm to 19.4 ± 3.7 mm, p 〈 0.05, RV diameter 29.3 ± 5.0 mm to 27.8 ± 4.2 mm, p 〈 0.05). Significant improvement of other monitored parameters occurred 3 months after CRT implantation: left ventricle (LV) end-diastolic diameter 70.5 ± 7.8 mm to 66.1 ± 8.3 mm, p 〈 0.001, LV ejection fraction 22.0 ± 5.4% to 27.1 ± 9.8%, p 〈 0.05, pulmonary artery pressure (peak gradient of tricuspid regurgitation) 37.1 ± 14.8 mm Hg to 27.6 ± 8.9 mm Hg, p 〈 0.001, tricuspid regurgitation (grade) 1.9 ± 0.9 to 1.5 ± 0.6, p 〈 0.05, mitral regurgitation (grade) 2.6 ± 0.9 to 2.2 ± 0.9, p 〈 0.001, LV dP/dt max (peak positive rate of pressure rise [slope of mitral regurgitant jet]) 482.4 ± 155.4 mm Hg/s to 981.2 ± 654.5 mm Hg/s, p 〈 0.001, velocity time integral (VTI) in LV outflow tract (LVOT) 14.1 ± 4.3 cm to 16.7 ± 4.1 cm, p 〈 0.001. In the group of nonresponders, only 2 parameters improved significantly: LV dP/dt max 561.2 ± 347.9 mm Hg/s to 1024.5 ± 745.3 mm Hg/s, p 〈 0.001, and LVOT VTI 14.5 ± 3.0 cm to 16.3 ± 2.9 cm, p 〈 0.001. Other echocardiographic parameters did not show any important changes, and no changes occurred between 3 and 15 months. On the contrary, after 15 months we saw significant progression of tricuspid regurgitation in nonresponders. In multivariate analysis, combination of baseline delay between time to peak systolic velocity in ejection phase at basal septal and basal lateral segments (Ts-lateral-septal delay) and serum creatinine was a strong predictor of clinical CRT response (area under curve was 0.80, percentage of correct decision was 82%). In the group of responders, significant changes of most monitored echocardiographic parameters were observed 3 months after CRT implantation. The only parameters which changed significantly after 15 months, but not previously, were the systolic function of the RV and the decrease in the RV size. In the group of nonresponders, these changes were not observed.
- 1 December 2011
- Published by Taylor & Francis in Acta Cardiologica
- Vol. 66 (6) , 797-801
Thoracoscopic left ventricular lead implantation
Cardiac resynchronization therapy is a therapeutic option in patients with chronic heart failure. Epicardial lead implantation for biventricular pacing is usually the method of second choice after failed coronary sinus cannulation. The present study describes an initial experience with minimally invasive surgical lead implantation using thoracoscopy. Since August 2008, a total of 17 patients (mean age 69.6 + 11.1 years) with congestive heart failure, NYHA functional class 3.1 +/- 0.4, and depressed ejection function (24.8% +/- 5.7%) were referred for surgery because of failed left ventricular lead implantation through the coronary sinus. Under single-lung ventilation and video-assisted thoracoscopy, epimyocardial steroid-eluting screw-in leads were implanted on the left ventricular free wall. There were no in-hospital deaths or major co-morbidities. The mean skin-to-skin operating time was 115.9 +/- 32.1 min, and the post-operative average length of stay was 8.4 +/- 2.5 days. Intraoperative acute threshold capture of the left ventricular lead was 0.88 +/- 0.54 V/0.5 ms, and the value of lead impedance was 434.7 +/- 110.8 Omega. Extension to a small thoracotomy was necessary in 1 patient to stop epicardial vein bleeding. Minimally invasive left ventricular lead implantation is a safe procedure with excellent acute threshold capture.
- 1 December 2011
- Published by Taylor & Francis in Acta Cardiologica
- Vol. 66 (6) , 797-801
Thoracoscopic left ventricular lead implantation
Cardiac resynchronization therapy is a therapeutic option in patients with chronic heart failure. Epicardial lead implantation for biventricular pacing is usually the method of second choice after failed coronary sinus cannulation. The present study describes an initial experience with minimally invasive surgical lead implantation using thoracoscopy. Since August 2008, a total of 17 patients (mean age 69.6 + 11.1 years) with congestive heart failure, NYHA functional class 3.1 +/- 0.4, and depressed ejection function (24.8% +/- 5.7%) were referred for surgery because of failed left ventricular lead implantation through the coronary sinus. Under single-lung ventilation and video-assisted thoracoscopy, epimyocardial steroid-eluting screw-in leads were implanted on the left ventricular free wall. There were no in-hospital deaths or major co-morbidities. The mean skin-to-skin operating time was 115.9 +/- 32.1 min, and the post-operative average length of stay was 8.4 +/- 2.5 days. Intraoperative acute threshold capture of the left ventricular lead was 0.88 +/- 0.54 V/0.5 ms, and the value of lead impedance was 434.7 +/- 110.8 Omega. Extension to a small thoracotomy was necessary in 1 patient to stop epicardial vein bleeding. Minimally invasive left ventricular lead implantation is a safe procedure with excellent acute threshold capture.
- 1 December 2011
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 53 (Suppl.) , 53-77
Komorové arytmie
- 1 December 2011
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 53 (Suppl.) , 53-77
Komorové arytmie
- 1 June 2011
- Vol. 57 (6) , 546-50
[Long-term outcome of catheter ablation therapy of supraventricular tachyarrhythmias].
The aim of the article is presentation of our results and experiences with radiofrequency catheter ablation (CA) in the therapy of supraventricular tachyarrhythmias. From 1996 to 2009, 1 485 patients underwent CA (total procedure number - 1 627). The group consist of 772 patients with paroxysmal atrioventricular nodal reentry tachycardia (AVNRT): 484 women, mean age 50.3 +/- 16.4 years; 312 patients with atrioventricular reentry tachycardia (AVRT): 145 women, mean age 40.1 +/- 14.9 years; 391 patients with typical atrial flutter (AF): 96 women, mean age 61.6 +/- 11 years; and 64 patients with atrial tachycardia (AT): 35 women, mean age 53.6 +/- 14.2 years, focal AT 33, macroreentrant AT 31. CA was performed for more than one type of arrhythmia in 54 patients. Acute ablation success was achieved in 98.7% of patients with AVNRT, 94.6% of patients with AVRT, 97.7% of patients with AF, and 81.3% of patients with AT. Serious procedure complications occurred in 22 patients (1.4%). The recurrence rate was 1.8-12.5%. 88 patients underwent successful reablation procedure. Long-term ablation success was achieved in 89-99% of patients depending on the different type of arrhythmia. During the long-term follow-up (mean 73 +/- 38 months) died 23 patients, the most common cause of death was malignancy (9 patients). Our long-term experience and good results documented high success rate and safety of radiofrequency catheter ablation in the therapy of patients with supraventricular tachyarrhythmias.
- 1 June 2011
- Vol. 57 (6) , 546-50
[Long-term outcome of catheter ablation therapy of supraventricular tachyarrhythmias].
The aim of the article is presentation of our results and experiences with radiofrequency catheter ablation (CA) in the therapy of supraventricular tachyarrhythmias. From 1996 to 2009, 1 485 patients underwent CA (total procedure number - 1 627). The group consist of 772 patients with paroxysmal atrioventricular nodal reentry tachycardia (AVNRT): 484 women, mean age 50.3 +/- 16.4 years; 312 patients with atrioventricular reentry tachycardia (AVRT): 145 women, mean age 40.1 +/- 14.9 years; 391 patients with typical atrial flutter (AF): 96 women, mean age 61.6 +/- 11 years; and 64 patients with atrial tachycardia (AT): 35 women, mean age 53.6 +/- 14.2 years, focal AT 33, macroreentrant AT 31. CA was performed for more than one type of arrhythmia in 54 patients. Acute ablation success was achieved in 98.7% of patients with AVNRT, 94.6% of patients with AVRT, 97.7% of patients with AF, and 81.3% of patients with AT. Serious procedure complications occurred in 22 patients (1.4%). The recurrence rate was 1.8-12.5%. 88 patients underwent successful reablation procedure. Long-term ablation success was achieved in 89-99% of patients depending on the different type of arrhythmia. During the long-term follow-up (mean 73 +/- 38 months) died 23 patients, the most common cause of death was malignancy (9 patients). Our long-term experience and good results documented high success rate and safety of radiofrequency catheter ablation in the therapy of patients with supraventricular tachyarrhythmias.