Ludek Haman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ludek Haman has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Petr Parizek
1st Deptartment of Internal Medicine - Cardioangiology, Faculty of Medicine in Hradec Kralove, Charles University in Prague, Hradec Kralove, Czech Republic
16 shared publications - Radek Pudil
2nd Department of Medicine, Charles University, Prague, Faculty of Medicine, Hradec Králové
5 shared publications Miloslav Tauchman
Department of Cardiovascular Medicine, University Hospital, Hradec Kralove, Czech Republic
4 shared publicationsRobert Čihák
4 shared publicationsMiloš Táborský
3 shared publications- Vladimir Palicka
Institute of Clinical Biochemistry and Diagnostics, University Hospital Hradec Kralove and Faculty of Medicine in Hradec Kralove, Charles University, 50005 Hradec Kralove, Czech Republic
3 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (21) , 8731
Predicting Persistent Left Ventricular Dysfunction After Cardiac Resynchronization Therapy Upgrade in Pacing-Induced Cardiomyopathy
Background/Objectives: Pacing-induced cardiomyopathy (PICM) is potentially reversible after cardiac resynchronization therapy (CRT) upgrade, but severe left ventricular dysfunction persists in some patients. We evaluated predictors of persistent left ventricular ejection fraction (LVEF) ≤ 35% after CRT upgrade and long-term outcomes. Methods: We analysed 60 patients undergoing CRT upgrade for PICM. The primary outcome was persistent LVEF ≤ 35% at 12 months. Clinical, electrocardiographic, echocardiographic, and long-term outcomes were assessed. Results: At 12 months, median LVEF increased from 30% to 45% (p < 0.01), and 82% of patients recovered to an LVEF > 35%. Persistent severe left ventricular dysfunction was associated with lower baseline LVEF (22% vs. 30%; p < 0.01), greater left ventricular end-diastolic diameter (LVEDD) (65 mm vs. 58 mm; p = 0.03), and longer post-CRT QRS duration (154 ms vs. 140 ms; p = 0.02); none remained independently significant after multivariable adjustment. No patient with baseline LVEF > 25% and LVEDD < 65 mm had persistent severe LV dysfunction, compared with 46% of those with LVEF ≤ 25% and LVEDD ≥ 65 mm. In the 12-month landmark analysis, mortality through 60 months after CRT upgrade was 55% in patients with persistent severe LV dysfunction and 31% in those with LVEF recovery. Conclusions: CRT upgrade was associated with substantial recovery of LV systolic function in patients with PICM. Severe baseline LV dysfunction and LV dilatation were associated with a lower likelihood of recovery to an LVEF > 35%. These exploratory findings may aid risk stratification but require prospective validation.
- 9 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (21) , 8731
Open AccessPredicting Persistent Left Ventricular Dysfunction After Cardiac Resynchronization Therapy Upgrade in Pacing-Induced Cardiomyopathy
Background/Objectives: Pacing-induced cardiomyopathy (PICM) is potentially reversible after cardiac resynchronization therapy (CRT) upgrade, but severe left ventricular dysfunction persists in some patients. We evaluated predictors of persistent left ventricular ejection fraction (LVEF) ≤ 35% after CRT upgrade and long-term outcomes. Methods: We analysed 60 patients undergoing CRT upgrade for PICM. The primary outcome was persistent LVEF ≤ 35% at 12 months. Clinical, electrocardiographic, echocardiographic, and long-term outcomes were assessed. Results: At 12 months, median LVEF increased from 30% to 45% (p < 0.01), and 82% of patients recovered to an LVEF > 35%. Persistent severe left ventricular dysfunction was associated with lower baseline LVEF (22% vs. 30%; p < 0.01), greater left ventricular end-diastolic diameter (LVEDD) (65 mm vs. 58 mm; p = 0.03), and longer post-CRT QRS duration (154 ms vs. 140 ms; p = 0.02); none remained independently significant after multivariable adjustment. No patient with baseline LVEF > 25% and LVEDD < 65 mm had persistent severe LV dysfunction, compared with 46% of those with LVEF ≤ 25% and LVEDD ≥ 65 mm. In the 12-month landmark analysis, mortality through 60 months after CRT upgrade was 55% in patients with persistent severe LV dysfunction and 31% in those with LVEF recovery. Conclusions: CRT upgrade was associated with substantial recovery of LV systolic function in patients with PICM. Severe baseline LV dysfunction and LV dilatation were associated with a lower likelihood of recovery to an LVEF > 35%. These exploratory findings may aid risk stratification but require prospective validation.
- Open Access
- 21 October 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (11)
Nationwide assessment of early hospitalizations and mortality after pulsed field ablation
- 21 October 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (11)
Open AccessNationwide assessment of early hospitalizations and mortality after pulsed field ablation
- Open Access
Long Term Outcomes and Predictors of Reverse Remodelling After Cardiac Resynchronization Therapy Upgrade
Background and Objectives: Upgrades to cardiac resynchronization therapy (CRT) account for approximately one quarter of all CRT indications. Although recent clinical trials have demonstrated significant clinical benefits of upgrade procedures, data on the long-term clinical effects of CRT upgrades remain limited. This study aimed to evaluate long-term clinical, echocardiographic, and device-related outcomes after CRT upgrade and to determine predictors of left ventricular reverse remodelling. Materials and Methods: A total of 97 patients underwent CRT upgrade at a tertiary referral centre, including 57 patients upgraded to CRT with pacemaker (CRT-P) and 40 to CRT with defibrillator (CRT-D). Results: During a 5-year follow-up period, 46 patients (47%) died from any cause. Appropriate device therapy was recorded in 13 (33%) CRT-D patients. The composite endpoint of death or time to first appropriate shock occurred in 25 (63%) CRT-D patients compared with 21 (37%) CRT-P patients (p = 0.013). Patients with CRT-P demonstrated a significantly greater improvement in left ventricular ejection fraction (LVEF) than those with CRT-D (15% vs. 9%, p < 0.003). Greater LVEF improvement was observed in patients with non-ischemic compared with ischemic cardiomyopathy (17% vs. 10%, p < 0.01). In multivariable analysis, pacemaker-induced cardiomyopathy (PICMP) was identified as a predictor of left ventricular (LV) reverse remodelling. Conclusions: In this prospective, non-randomized cohort, CRT upgrade was associated with long-term clinical and echocardiographic improvement. Differences observed between CRT-P and CRT-D groups should be interpreted cautiously, as the study was not designed for direct comparison. PICMP was independently associated with LV reverse remodelling.
Open AccessLong Term Outcomes and Predictors of Reverse Remodelling After Cardiac Resynchronization Therapy Upgrade
Background and Objectives: Upgrades to cardiac resynchronization therapy (CRT) account for approximately one quarter of all CRT indications. Although recent clinical trials have demonstrated significant clinical benefits of upgrade procedures, data on the long-term clinical effects of CRT upgrades remain limited. This study aimed to evaluate long-term clinical, echocardiographic, and device-related outcomes after CRT upgrade and to determine predictors of left ventricular reverse remodelling. Materials and Methods: A total of 97 patients underwent CRT upgrade at a tertiary referral centre, including 57 patients upgraded to CRT with pacemaker (CRT-P) and 40 to CRT with defibrillator (CRT-D). Results: During a 5-year follow-up period, 46 patients (47%) died from any cause. Appropriate device therapy was recorded in 13 (33%) CRT-D patients. The composite endpoint of death or time to first appropriate shock occurred in 25 (63%) CRT-D patients compared with 21 (37%) CRT-P patients (p = 0.013). Patients with CRT-P demonstrated a significantly greater improvement in left ventricular ejection fraction (LVEF) than those with CRT-D (15% vs. 9%, p < 0.003). Greater LVEF improvement was observed in patients with non-ischemic compared with ischemic cardiomyopathy (17% vs. 10%, p < 0.01). In multivariable analysis, pacemaker-induced cardiomyopathy (PICMP) was identified as a predictor of left ventricular (LV) reverse remodelling. Conclusions: In this prospective, non-randomized cohort, CRT upgrade was associated with long-term clinical and echocardiographic improvement. Differences observed between CRT-P and CRT-D groups should be interpreted cautiously, as the study was not designed for direct comparison. PICMP was independently associated with LV reverse remodelling.
- 1 December 2016
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 58 (6) , e636-e683
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Summary of the document prepared by the Czech Society of Cardiology
- 1 December 2016
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 58 (6) , e636-e683
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Summary of the document prepared by the Czech Society of Cardiology
- Open Access
- 30 March 2016
- Published by Palacky University Olomouc in Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia
- Vol. 160 (1) , 106-110
Increase of serum interleukin 6 and interferon γ is associated with the number of impulses in patients with supraventricular arrhythmias treated with radiofrequency catheter ablation
Activation of the immune system plays a pathogenic role in the process of myocardial remodeling in patients with supraventricular arrhythmias. The intensity of this process is associated with the effectiveness of electrical cardioversion and radiofrequency catheter ablation (RFA). The aim of this study was to test the ability of the biochip microarray to detect immune parameters in patients with supraventricular arrhythmias undergoing RFA treatment. We used a biochip-based microarray system to determine multiple immune parameters in a group of 35 patients who had undergone RFA for atrioventricular nodal reentry tachycardia (AVNRT), atrial flutter (AFL) and atrial fibrillation (AF). Before the procedure, serum IL-6 and VEGF levels were significantly increased in patients with atrial fibrillation compared to patients with AVNRT (IL-6: 6.4±6.3 ng/L vs. 1.5±0.7 ng/L, P < 0.01; VEGF: 132.4±74 ng/L vs. 88.5±56.4 ng/L, P < 0.01). After the procedure, serum IL-6, VEGF, IFN-γ and MCP-1 levels significantly increased compared to baseline (IL-6: 5.2±4.8 ng/L vs. 2.9±2.1 ng/L, P < 0.01; VEGF: 195.8±160 ng/L vs. 119.8± 110 ng/L, P < 0.05; IFN-γ: 3.1±1.2 ng/L vs. 2.3±0.6 ng/L, P < 0.05; MCP-1: 104.1±84.5 ng/L vs. 54.5±50 ng/L, P < 0.05). Serum IL-6 and IFN-γ were associated with the number of RFA applications (IL-6: r = 0.56, n 33; IFN-γ: r = 0.47, n 33). This study showed that biochip-based microarray can be useful in the detection of immune activation in patients with arrhythmias and can detect myocardial injury after RF procedures.
- 30 March 2016
- Published by Palacky University Olomouc in Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia
- Vol. 160 (1) , 106-110
Open AccessIncrease of serum interleukin 6 and interferon γ is associated with the number of impulses in patients with supraventricular arrhythmias treated with radiofrequency catheter ablation
Activation of the immune system plays a pathogenic role in the process of myocardial remodeling in patients with supraventricular arrhythmias. The intensity of this process is associated with the effectiveness of electrical cardioversion and radiofrequency catheter ablation (RFA). The aim of this study was to test the ability of the biochip microarray to detect immune parameters in patients with supraventricular arrhythmias undergoing RFA treatment. We used a biochip-based microarray system to determine multiple immune parameters in a group of 35 patients who had undergone RFA for atrioventricular nodal reentry tachycardia (AVNRT), atrial flutter (AFL) and atrial fibrillation (AF). Before the procedure, serum IL-6 and VEGF levels were significantly increased in patients with atrial fibrillation compared to patients with AVNRT (IL-6: 6.4±6.3 ng/L vs. 1.5±0.7 ng/L, P < 0.01; VEGF: 132.4±74 ng/L vs. 88.5±56.4 ng/L, P < 0.01). After the procedure, serum IL-6, VEGF, IFN-γ and MCP-1 levels significantly increased compared to baseline (IL-6: 5.2±4.8 ng/L vs. 2.9±2.1 ng/L, P < 0.01; VEGF: 195.8±160 ng/L vs. 119.8± 110 ng/L, P < 0.05; IFN-γ: 3.1±1.2 ng/L vs. 2.3±0.6 ng/L, P < 0.05; MCP-1: 104.1±84.5 ng/L vs. 54.5±50 ng/L, P < 0.05). Serum IL-6 and IFN-γ were associated with the number of RFA applications (IL-6: r = 0.56, n 33; IFN-γ: r = 0.47, n 33). This study showed that biochip-based microarray can be useful in the detection of immune activation in patients with arrhythmias and can detect myocardial injury after RF procedures.
- 1 February 2016
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 58 (1) , e153-e174
Updated European Heart Rhythm Association Practical Guide on the use of non-vitamin K antagonist anticoagulants in patients with non-valvular atrial fibrillation: Summary of the document prepared by the Czech Society of Cardiology
- 1 February 2016
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 58 (1) , e153-e174
Updated European Heart Rhythm Association Practical Guide on the use of non-vitamin K antagonist anticoagulants in patients with non-valvular atrial fibrillation: Summary of the document prepared by the Czech Society of Cardiology
- 1 October 2014
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 56 (5) , e427-e432
Potentially misleading manifestation of a ventricular pre-excitation
We present the case report of a 56-year-old man with an unusual manifestation of an accessory pathway. Failure to detect, or incorrect diagnosis, of this anomaly could have put the patient at high risk of sudden cardiac death. The accessory pathway described in this case report was located at the left posteroseptal area and presented initially with a broad QRS complex tachycardia. Despite being pre-excited atrial fibrillation, it could have been misinterpreted as ventricular tachycardia. Once the rhythm had changed to sinus, a Q-wave in the inferior ECG leads became apparent. This finding could have been misdiagnosed as an old myocardial infarction and treated as such, including prescription of betablockers which might, in theory, increase the risk of sudden cardiac death. The treatment of choice for the patient was radio frequency ablation of the accessory pathway
- 1 October 2014
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 56 (5) , e427-e432
Potentially misleading manifestation of a ventricular pre-excitation
We present the case report of a 56-year-old man with an unusual manifestation of an accessory pathway. Failure to detect, or incorrect diagnosis, of this anomaly could have put the patient at high risk of sudden cardiac death. The accessory pathway described in this case report was located at the left posteroseptal area and presented initially with a broad QRS complex tachycardia. Despite being pre-excited atrial fibrillation, it could have been misinterpreted as ventricular tachycardia. Once the rhythm had changed to sinus, a Q-wave in the inferior ECG leads became apparent. This finding could have been misdiagnosed as an old myocardial infarction and treated as such, including prescription of betablockers which might, in theory, increase the risk of sudden cardiac death. The treatment of choice for the patient was radio frequency ablation of the accessory pathway
- 25 July 2014
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 29 (5) , 757-762
Thoracoscopic Radiofrequency Ablation for Lone Atrial Fibrillation: Box-Lesion Technique
We report the feasibility and outcomes of box-lesion ablation technique to treat stand-alone atrial fibrillation (AF). There were 41 patients with a mean age of 57.6 ± 8.0 years who underwent bilateral totally thoracoscopic ablation of symptomatic paroxysmal AF (n = 24; 58.5%), persistent AF (n = 9; 22.0%), or long-standing persistent AF (n = 8; 19.5%). The box-lesion procedure included bilateral pulmonary vein and left atrial posterior wall ablation using irrigated bipolar radiofrequency with documentation of conduction block. There were no intra- or perioperative ablation-related complications. There was no operative mortality, no myocardial infarction, and no stroke. Skin-to-skin procedure time was 119.5 ± 23.7 minutes and the postoperative average length of stay was 7.4 ± 2.5 days. At discharge, 38 patients (93%) were in sinus rhythm. Median follow-up time was 641 days (ranges, 185-1636 days). At six months postsurgery, 31 patients of 41 (76%) were free from AF without the need of antiarrhythmic drugs. One-year success rate was 73% (off antiarrhythmic drugs). Eight patients (19.5%) underwent catheter reablation. Thirty-six patients (90%) were in sinus rhythm at six months after the last performed ablation (surgical ablation or catheter reablation). At 12 months follow-up, 61% patients discontinued oral anticoagulant therapy. The thoracoscopic box-lesion ablation procedure is a safe, effective, and minimally invasive method for the treatment of isolated (lone) AF. This procedure provided excellent short-term freedom from AF.
- 25 July 2014
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 29 (5) , 757-762
Thoracoscopic Radiofrequency Ablation for Lone Atrial Fibrillation: Box-Lesion Technique
We report the feasibility and outcomes of box-lesion ablation technique to treat stand-alone atrial fibrillation (AF). There were 41 patients with a mean age of 57.6 ± 8.0 years who underwent bilateral totally thoracoscopic ablation of symptomatic paroxysmal AF (n = 24; 58.5%), persistent AF (n = 9; 22.0%), or long-standing persistent AF (n = 8; 19.5%). The box-lesion procedure included bilateral pulmonary vein and left atrial posterior wall ablation using irrigated bipolar radiofrequency with documentation of conduction block. There were no intra- or perioperative ablation-related complications. There was no operative mortality, no myocardial infarction, and no stroke. Skin-to-skin procedure time was 119.5 ± 23.7 minutes and the postoperative average length of stay was 7.4 ± 2.5 days. At discharge, 38 patients (93%) were in sinus rhythm. Median follow-up time was 641 days (ranges, 185-1636 days). At six months postsurgery, 31 patients of 41 (76%) were free from AF without the need of antiarrhythmic drugs. One-year success rate was 73% (off antiarrhythmic drugs). Eight patients (19.5%) underwent catheter reablation. Thirty-six patients (90%) were in sinus rhythm at six months after the last performed ablation (surgical ablation or catheter reablation). At 12 months follow-up, 61% patients discontinued oral anticoagulant therapy. The thoracoscopic box-lesion ablation procedure is a safe, effective, and minimally invasive method for the treatment of isolated (lone) AF. This procedure provided excellent short-term freedom from AF.
- Open Access
- 1 February 2014
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 56 (1) , e42-e56
European Heart Rhythm Association practical guide on the use of new oral anticoagulants in patients with non-valvular atrial fibrillation. Summary of the document prepared by the Czech Society of Cardiology
- 1 February 2014
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 56 (1) , e42-e56
Open AccessEuropean Heart Rhythm Association practical guide on the use of new oral anticoagulants in patients with non-valvular atrial fibrillation. Summary of the document prepared by the Czech Society of Cardiology